Search NASA⌕ Search

SEARCH · Search NASA

Results for “VFR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Secondary Organic Aerosol from OH Oxidation of Acyclic Terpenes Is More Viscous and Less Volatile than That of Their Cyclic Analogs

Biogenic volatile organic compounds (BVOCs), a dominant source of secondary organic aerosol (SOA) globally, exhibit emission rates and composition that are plant species-specific and vary with environmental stressors. A common outcome of plant stress is increased emissions of acyclic terpenes. The paucity of information about acyclic terpene SOA chemistry contributes to uncertainties in predictions of SOA global loadings and impacts on Earth’s radiative budget, particularly in a changing climate where acyclic terpene emissions could become more prominent. This study compared properties of SOA derived from OH oxidation of acyclic and cyclic monoterpenes (ß-ocimene, a-pinene) and sesquiterpenes (ß-farnesene, ß-caryophyllene). Single particle mass spectrometry was used for assessing shape, density, and evaporation kinetics of size-selected SOA particles, and nanospray desorption electrospray ionization high-resolution mass spectrometry (nano-DESI-HRMS) was used to measure molecular composition of SOA. Acyclic terpene SOA exhibited higher viscosity and lower volatility compared to cyclic terpene SOA, and had a greater volume fraction remaining (VFR) after ~24 hours of evaporation - approximately 1.3-1.6 times higher VFR than that of cyclic terpene SOA. Additionally, HRMS analysis revealed greater chemical diversity and higher fractions of extremely low volatility compounds (56-62% ELVOC/LVOC) in acyclic terpene SOA compared to cyclic counterparts (25-37% ELVOC/LVOC). Our findings highlight the potential importance of accounting for acyclic terpene aerosol chemistry under conditions of plant stress to improve predictions of SOA loadings and impacts.

SOA physical properties↗

Machine learning based prediction of airflow maldistribution in air-to-refrigerant heat exchangers

Flow maldistribution is a common challenge in heat exchanger (HX) design and particularly important for air-to-refrigerant geometries where capacity losses can approach 65%. This has a major impact on central air conditioning systems, as compact duct design motivates the use of A-type HXs which are known to be affected by airflow maldistribution. Because velocity profiles are difficult to predict, components are often oversized leading to increased material cost, system footprint, and refrigerant charge. Several studies detail airflow maldistribution for individual HXs and packages, but findings cannot always be extrapolated to new designs. In this work, a machine learning (ML) based flow profile prediction framework is developed and applied to two common package configurations: (i) A-type and (ii) U-type HXs, across a broad range of HX geometries and flow rates. Porous media CFD simulations are validated against independent data for both package types as well as comprehensive in house measurements for a finless geometry with shape optimized non-round tubes, which validates the framework for new heat transfer surfaces. The ML models are trained on the porous media CFD simulations, predicting volumetric flow rate (VFR) within 1.1% and 1.9% with maximum relative L 2 norm errors of 0.48 and 0.65, respectively, while also delivering 10 5 speed up factor compared to full porous media CFD. HX level simulations show an up to 9% reduction in heat transfer from flow maldistribution, with greater losses occurring at smaller half apex angles. This framework enables rapid and highly accurate prediction of airflow maldistribution induced capacity degradation.

42 ENGINEERING↗

Intercell Power Transformer for Power Balancing of Polyphase Wireless Power Transfer Systems

Polyphase wireless power transfer (PWPT) systems experience receiver side imbalances in misaligned conditions. This paper proposes a method for power balancing in PWPT systems, specifically addressing the challenges caused by receivers coil unequal coupling. An intercell power transformer (IPT) is introduced at the receiver side to mitigate the effects of coil mismatch. Simulations of the PWPT system incorporating IPT demonstrate its effectiveness in enhancing power distribution. For voltage-fed rectifiers (VFR), the IPT increases the conduction angle, resulting in higher output power. In current- fed rectifiers (CFR), the IPT promotes uniform power sharing among rectifiers, thereby reducing electrical stress on semiconductor devices and passive components. Simulation results indicate that, under coil misalignment, the IPT improves output power by approximately 49% for VFRs and 44% for CFRs compared to conventional PWPT systems without IPT.

Wojda, Rafal [ORNL] (ORCID:0000000286609268)↗