Search NASA⌕ Search

SEARCH · Search NASA

Results for “VHF gun”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

X-ray FEL linear accelerator design via start-to-end global optimization

An X-ray Free Electron Laser (FEL) prefers using an electron beam with low emittance, small energy spread, and a high core current to generate coherent radiation through an undulator. In order to attain such a high brightness beam, the linear accelerator beam dynamics design generally involves separate photoinjector optimization and linac optimization. In this paper, we propose a new beam dynamics design strategy based on global optimization with fast start-to-end simulations from the photocathode to the end of the accelerator. The new start-to-end model significantly reduces the simulation time and makes the global optimization practical. The global optimization method avoids the need to choose a single solution based on bunch length at the injector exit for the linac optimization and helps find the solution with unfavorable bunch length at the injector exit but better phase space distribution that can result in better final electron beam phase space distribution at the entrance of the undulator. Here, using the start-to-end global optimization, we showed in an application example, with a 100 pC beam that good transverse emittance and over kilo-Ampere final core current can be attained using a photoinjector that consists of a VHF gun and boosting RF cavities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Performance Accelerator Modeling: Toward Improving Controls and Diagnostics for High-Brightness Beams in Experiment

One of the main charges of beam physics is to improve the overall beam quality delivered to experiments and applications, which is generally quantified by the beam brightness. High brightness beams have numerous applications, including x-ray free electron lasers and ultrafast electron diffraction (UED). To these ends, this thesis details efforts to use high-performance models --- high-fidelity models that execute quickly --- for controls and diagnostics. To demonstrate the generality of these techniques, this thesis focuses on three of the most successful photoinjector designs currently used worldwide: the UCLA/SLAC/BNL-type high-gradient S-band gun, the continuous-wave high-repetition rate VHF APEX gun and the L-band DESY-PITZ-type gun. Work will be shown from Pegasus (UCLA), HiRES (LBNL) and FAST (FNAL).Specifically, data-driven models for online virtual diagnostics are presented, in this case, in the context of UED at HiRES, leading to a temporal resolution improvement. Methods for improving the fidelity of physics-based models are discussed, with examples at HiRES, Pegasus and FAST. Markov-chain Monte Carlo analysis is applied to match simulations, in the context of photocathode studies at HiRES and Pegasus. Lastly, the augmentation of online model-based predictions with model-independent optimization is explored in a fluctuating environment at Pegasus and HiRES. A central theme of this dissertation is working with parameter fluctuations when modeling an accelerator beamline. Long-term drifts and shot-to-shot jitter exist in every accelerator to a varying degree and therefore play an important role in every chapter of this dissertation. This thesis attempts to address the issues associated with these fluctuations when trying to develop faithful model representations of the system.

43 PARTICLE ACCELERATORS↗

Multiplexed photoinjector optimization for high-repetition-rate free-electron lasers

The multiplexing capabilities of superconducting X-ray free-electron lasers (FELs) have gained much attention in recent years. The demanding requirements for photon properties from multiple undulator lines necessitate more flexible beam manipulation techniques to achieve the goal of “beam on demand”. In this paper, we investigate a multiplexed configuration for the photoinjector of high-repetition-rate FELs that aims to simultaneously provide low-emittance electron beams of different charges. A parallel, multi-objective genetic algorithm is implemented for the photoinjector parameter optimization. The proposed configuration could drastically enhance the flexibility of beam manipulation to improve multiplexing capabilities and realize the full potential of the facility.

47 OTHER INSTRUMENTATION↗

Observations of VHF emissions from 50-mA electron beam injections in the ionosphere that are associated with beam-induced discharges

Results are presented of observations of strong VHF plasma waves with amplitudes in excess of 0.1 mV/m (Hz)1/2 associated with 50 mA electron beam injections in the ionosphere. Data from three swept-frequency receivers carried on two daughter payloads are analyzed to determine the emission spectra of the electron beam for various energies and currents. These results were obtained from the rocket-borne experiment SCEX 3, NASA flight 39.002 UE, launched February 1, 1990. The accelerator payload also carried photometers, which measured luminosity at wavelengths of 391.4 and 380.5 nm. Several times during electron gun activity the measured luminosity increased much faster than proportional to the beam current. This nonlinear increase is evidence that a discharge is occurring in the vicinity of the accelerator payload. It is inferred from the uniform distribution of the luminosity around the accelerator payload that the observed discharge extends significantly outside the beam cylinder.

Goerke, R. T.↗