Measurement of the structural damping ratio of some common materials at 293 K and 77 K in air
The structural damping ratio of various materials has been measured at 293 K and 77 K through a rod bending excitation setup. The aim was to extract the material-dependent structural damping ratio as a first approach to in-vacuum damping. However, for simplicity, testing has been conducted in air with measures to minimize the effect of viscous damping from viscous drag. The setup and methodology are described in this paper, as well as the setup limitations and proposed ways to overcome these limitations for an improved setup. The results are presented in a summary table and discussed.