Non-congruence of Thermally Driven Structural and Electronic Transitions in VO2
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
It is not known whether the asymptotic behavior of whole body O2 consumption (VO2) at maximal work rates (WR) is explained by similar behavior of VO2 in the exercising legs. To resolve this question, simultaneous measurements of body and leg VO2 were made at submaximal and maximal levels of effort breathing normoxic and hypoxic gases in seven trained male cyclists (maximal VO2, 64.7 +/- 2.7 ml O2.min-1.kg-1), each of whom demonstrated a reproducible VO2-WR asymptote during fatiguing incremental cycle ergometry. Left leg blood flow was measured by constant-infusion thermodilution, and total leg VO2 was calculated as the product of twice leg flow and radial arterial-femoral venous O2 concentration difference. The VO2-WR relationships determined at submaximal WR's were extrapolated to maximal WR as a basis for assessing the body and leg VO2 responses. The differences between measured and extrapolated maximal VO2 were 235 +/- 45 (body) and 203 +/- 70 (leg) ml O2/min (not significantly different). Plateauing of leg VO2 was associated with, and explained by, plateauing of both leg blood flow and O2 extraction and hence of leg VO2. We conclude that the asymptotic behavior of whole body VO2 at maximal WRs is a direct reflection of the VO2 profile at the exercising legs.
Insights into muscle energetics during exercise (e.g., muscular efficiency) are often inferred from measurements of pulmonary gas exchange. This procedure presupposes that changes of pulmonary O2 (VO2) associated with increases of external work reflect accurately the increased muscle VO2. The present investigation addressed this issue directly by making simultaneous determinations of pulmonary and leg VO2 over a range of work rates calculated to elicit 20-90% of maximum VO2 on the basis of prior incremental (25 or 30 W/min) cycle ergometry. VO2 for both legs was calculated as the product of twice one-leg blood flow (constant-infusion thermodilution) and arteriovenous O2 content difference across the leg. Measurements were made 3-5 min after each work rate imposition to avoid incorporation of the VO2 slow component above the lactate threshold. For all 17 subjects, the slope of pulmonary VO2 (9.9 +/- 0.2 ml O2.W-1.min-1) was not different (P greater than 0.05) from that for leg VO2 (9.2 +/- 0.6 ml O2.W-1.min-1). Estimation of "delta" efficiency (i.e., delta work accomplished divided by delta energy expended, calculated from slope of VO2 vs. work rate and a caloric equivalent for O2 of 4.985 cal/ml) using pulmonary VO2 measurements (29.1 +/- 0.6%) was likewise not significantly different (P greater than 0.05) from that made using leg VO2 measurements (33.7 +/- 2.4%). These data suggest that the net VO2 cost of metabolic "support" processes outside the exercising legs changes little over a relatively broad range of exercise intensities. Thus, under the conditions of this investigation, changes of VO2 measured from expired gas reflected closely those occurring within the exercising legs.
BACKGROUND: Maintaining intermediary metabolism is necessary for the health and well-being of astronauts on long-duration spaceflights. While peak oxygen uptake (VO2) is consistently decreased during prolonged bed rest, submaximal VO2 is either unchanged or decreased. METHODS: Submaximal exercise metabolism (61 +/- 3% peak VO2) was measured during ambulation (AMB day-2) and on bed rest days 4, 11, and 25 in 19 healthy men (32-42 yr) allocated into no exercise (NOE, N = 5) control, and isotonic exercise (ITE, N = 7) and isokinetic exercise (IKE, N = 7) training groups. Exercise training was conducted supine for two 30-min periods per day for 6 d per week: ITE training was intermittent at 60-90% peak VO2; IKE training was 10 sets of 5 repetitions of peak knee flexion-extension force at a velocity of 100 degrees s-1. Cardiac output was measured with the indirect Fick CO2 method, and plasma volume with Evans blue dye dilution. RESULTS: Supine submaximal exercise VO2 decreased significantly (*p < 0.05) by 10.3%* with ITE and by 7.3%* with IKE; similar to the submaximal cardiac output decrease of 14.5%* (ITE) and 20.3%* (IKE), but different from change in peak VO2 (+1.4% with ITE and -10.2%* with IKE) and decrease in plasma volume of -3.7% (ITE) and -18.0%* (IKE). Reduction of submaximal VO2 during bed rest correlated 0.79 (p < 0.01) with submaximal Qc, but was not related to change in peak VO2 or plasma volume. CONCLUSION: Reduction in submaximal oxygen uptake during prolonged bed rest is related to decrease in exercise but not resting cardiac output; perturbations in active skeletal muscle metabolism may be involved.
A study is presented of the effects of deconditioning following 7 days of continuous head-down (-6 degrees) bedrest on changes in steady-state VO2, O2, and recovery VO2 during the performance of constant-load exercises. The deconditioning effects of bedrest on the physical working capacity were manifested in the subjects by significant changes in VO2 kinetics following the 7 days of head-down bedrest. While the subjects demonstrated the ability to attain similar steady-state VO2, simulated weightlessness using head-down bedrest resulted in a reduction of total VO2 capacity and an increase in the O2 deficit and VO2 halftime during submaximal constant-load exercise. It is concluded that this change in VO2 kinetics was induced by reexposure of the cardiovascular system to the +1 Gz (upright) environment.
The VO2+ crossover, or permeability, through Nafion in a vanadium redox flow battery (VRFB) was monitored as a function of sulfuric acid concentration and VO2+ concentration. A vanadium rich solution was flowed on one side of the membrane through a flow field while symmetrically on the other side a blank or vanadium deficit solution was flowed. The blank solution was flowed through an electron paramagnetic resonance (EPR) cavity and the VO2+ concentration was determined from the intensity of the EPR signal. Concentration values were fit using a solution of Fick s law that allows for the effect of concentration change on the vanadium rich side. The fits resulted in permeability values of VO2+ ions across the membrane. Viscosity measurements of many VO2+ and H2SO4 solutions were made at 30 60 C. These viscosity values were then used to determine the effect of the viscosity of the flowing solution on the permeability of the ion. 2013 The Electrochemical Society. [DOI: 10.1149/2.004306jes] All rights reserved.
Head-down suspension (HDS) of rats has evolved as a useful model for the simulation of a microgravity environment. Previous HDS experiments with rats have shown an impaired capacity to perform aerobic exercise as demonstrated by reductions in maximum oxygen consumption (VO2 max), treadmill run time (RT), and mechanical efficiency (ME) of treadmill running at submaximal conditions. To determine whether endurance training (TR) before HDS would modify exercise performance, male Sprague-Dawley rats were assigned to nontrained (NT) or TR groups for 6 wk and exposed to HDS or cage control (CC) conditions for 29 days. The rats were tested for VO2 max, RT, and ME before treatment and on days 7, 14, 21, and 28. In addition, water and electrolyte excretion was measured on days 1 and 21 of the experimental period. Before HDS, the TR rats had significantly higher measures of VO2 max (15%) and RT (22%) than the NT rats. On day 28, HDS was associated with significant reductions in absolute VO2 max (ml/min) in TR (-30%) and NT (-14%) rats. Relative VO2 max (ml.min-1.kg-1) was significantly reduced in TR (-15%) but not NT rats. Similar reductions in RT occurred in TR (-37%) and NT (-35%) rats by day 28. ME was reduced 22% in both TR and NT rats after 28 days of suspension. HDS elicited diuresis, natriuresis, and kaliuresis in TR rats after 21 days but not after 24 h. In contrast, HDS-NT rats exhibited no diuretic, natriuretic, or kaliuretic responses.(ABSTRACT TRUNCATED AT 250 WORDS).
Aerobic fitness is best measured by Maximal Aerobic Capacity or VO2 Max which is defined as a measure of oxygen utilization and transport. Increased Vo2 max indicates improved oxygen consumption during high level exercise and is widely accepted as a predictor of an individual's likelihood of successfully completing a demanding task. As such, agencies and organizations have adopted VO2 max as part of a comprehensive set of physical requirements. The purpose of this study is to review the literature and existing medical and occupational VO2 max data, to propose a VO2 max standard for NASA astronauts for training and spaceflight.
Submaximal exercise (61+3% peak VO2) metabolism was measured before (AC day-2) and on bed rest day 4, 11, and 25 in 19 healthy men (32-42 yr) allocated into no exercise (NOE, N=5) control, and isotonic exercise (ITE, N=7)and isokinetic exercise (IKE, N=7) training groups. Training was conducting supine for two 30-min periods/d for 6 d/wk: ITE was 60-90% peak VO2: IKE was peak knee flexion-extension at 100 deg/s. Supine submaximal exercise 102 decreased significantly (*p<0.05) by 10.3%, with ITE and by 7.3%* with IKE; similar to the submaximal cardiac output (Q) change of -14.5%* (ITE) and -203%* (IKE), but different from change in peak VO2 (+1.4% with ITE and - 10.2%, with IKE) and plasma volume of -3.7% (ITE) and - 18.0% * (IKE). Thus, reduction of submaximal V02 during prolonged bed rest appears to respond to submaximal Q but is not related to change in peak VO2 or plasma volume.
Temperature-induced metal–insulator transition (MIT) in vanadium dioxide (VO2) has been under intense research interest for decades both theoretically and experimentally. Due to the complex nature of electron correlations, the underlying physics behind the MIT in VO2 has yet to be fully grasped. In this work, we utilize the fine resolution of the scattering-type scanning near-field optical microscope to investigate the MIT in an epitaxial VO2 thin film on the (100)R TiO2 substrate with mid-infrared light. Bidirectional tweed-like metal–insulator phase coexistence patterns are observed and understood under the Landau free energy paradigm. More interestingly, delayed metallic nucleation is observed near the surface cracks due to local strain relief. This research proposes ideas in investigating the temperature–pressure phase diagram and tuning the interplay between local strain and MIT in oxide thin films.
VO2 particles are promising materials for thermochromic smart windows that reduce building energy loss. Continuous-flow hydrothermal processes showcase advantages for synthesizing VO2 particles compared with traditional batch reaction systems. Mixers play a crucial role in particle fabrication in continuous-flow systems. In this study, a Center T-Mixer and a Collision Cross-Mixer are developed and implemented in a hot water fluidized suspension reaction (HWFSR) system. The influence of the resident time on the particle phase and size was evaluated, and properties of particles derived from systems equipped with differing mixers were compared. The resulting particles were characterized using techniques of X-ray powder diffraction (XRD) analysis, scanning electron microscopy (SEM), and differential scanning calorimetry (DSC). When compared with the Center T-Mixer, results indicate that the Collision Cross-Mixer has better control regarding the morphology and size distribution of resulting particles while improving the transition temperatures of the as-synthesized materials. HWFSR systems containing novel mixer designs are capable of producing pure M-phase VO2 particles in a single step contrary to the current reactor design that use a second postheat treatment step, and they are capable of synthesizing many other nanoparticle species, especially those requiring high temperature and pressure reaction conditions.
We investigate optical forces on oscillating dipoles close to a phase change vanadium dioxide (VO2) film, which exhibits a metal-insulator transition around 340 K and low thermal hysteresis. This configuration emulates the interaction between an illuminated nanosphere and an interface and we employ a classical description to capture its important aspects. We consider both electric and magnetic dipoles for two different configurations, namely with the dipole moments parallel and perpendicular to the VO2 film. By using Bruggeman theory to describe the effective optical response of the material, we show that the thermal hysteresis present in the VO2 transition clearly shows up in the behavior of optical forces. In the near-field regime, the force on both dipoles can change from attractive to repulsive just by heating (or cooling) the film for a selected frequency range. We also verified that the optical forces are comparable to the Casimir-Polder force in a similar system, revealing the possibility of modulating or even changing the sign of the resultant force on an illuminated nano-object due to the presence of a thermochromic material. We hope that this work contributes to set the grounds for alternative approaches to control light-matter interactions using phase-change materials.
The effects of simulated weightlessness (hind-limb suspension) and chemical sympathectomy (by repeated injections with guanethidine sulfate) on the maximum oxygen consumption (VO2 max) of female rats were investigated in rats assigned for 14 days to one of three groups: a head-down hind-limb suspension, a horizontal suspension with hind limbs weight bearing, or the caged control. The VO2 max values were assessed by having rats run on a treadmill enclosed in an airtight chamber. The hind-limb-suspended sympathectomized rats were found to exhibit shorter run times and lower mechanical efficiencies, compared to their presuspension values or the values from saline-injected suspended controls. On the other hand, the suspended sympathectomized rats did not demonstrate a decrease in the VO2 max values that was observed in saline-injected controls.
VO2 crystallizes in the monoclinic P2/m space group. The structure is one-dimensional and consists of one VO2 ribbon oriented in the (1, 0, 0) direction. there are two inequivalent V4+ sites. In the first V4+ site, V4+ is bonded in a tetrahedral geometry to four O2- atoms. There are a spread of V–O bond distances ranging from 1.61–1.91 Å. In the second V4+ site, V4+ is bonded in a rectangular see-saw-like geometry to four O2- atoms. There is two shorter (1.87 Å) and two longer (1.95 Å) V–O bond length. There are three inequivalent O2- sites. In the first O2- site, O2- is bonded in a distorted T-shaped geometry to three V4+ atoms. In the second O2- site, O2- is bonded in a water-like geometry to two V4+ atoms. In the third O2- site, O2- is bonded in a single-bond geometry to one V4+ atom.
VO2 crystallizes in the triclinic P-1 space group. The structure is one-dimensional and consists of one VO2 ribbon oriented in the (1, 0, 0) direction. there are two inequivalent V4+ sites. In the first V4+ site, V4+ is bonded in a rectangular see-saw-like geometry to four O2- atoms. There are a spread of V–O bond distances ranging from 1.91–2.02 Å. In the second V4+ site, V4+ is bonded in a tetrahedral geometry to four O2- atoms. There are a spread of V–O bond distances ranging from 1.61–1.89 Å. There are four inequivalent O2- sites. In the first O2- site, O2- is bonded in a bent 120 degrees geometry to two V4+ atoms. In the second O2- site, O2- is bonded in a single-bond geometry to one V4+ atom. In the third O2- site, O2- is bonded in a distorted T-shaped geometry to three V4+ atoms. In the fourth O2- site, O2- is bonded in a bent 120 degrees geometry to two V4+ atoms.
VO2 is trigonal omega-like structured and crystallizes in the monoclinic C2/m space group. The structure is two-dimensional and consists of one VO2 sheet oriented in the (0, 0, 1) direction. V4+ is bonded to six equivalent O2- atoms to form edge-sharing VO6 octahedra. There is two shorter (1.89 Å) and four longer (2.02 Å) V–O bond length. O2- is bonded in a distorted trigonal non-coplanar geometry to three equivalent V4+ atoms.
VO2 is trigonal omega-like structured and crystallizes in the monoclinic C2 space group. The structure is two-dimensional and consists of two VO2 sheets oriented in the (0, 0, 1) direction. V4+ is bonded to six O2- atoms to form edge-sharing VO6 octahedra. There are a spread of V–O bond distances ranging from 1.92–2.01 Å. There are two inequivalent O2- sites. In the first O2- site, O2- is bonded in a distorted trigonal non-coplanar geometry to three equivalent V4+ atoms. In the second O2- site, O2- is bonded in a distorted trigonal non-coplanar geometry to three equivalent V4+ atoms.