Search NASASearch

SEARCH · Search NASA

Results for “VOLT-AMPERE CHARACTERISTICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Applications Technology Satellites Battery and Power System Design

A summary of the ATS battery design which is onboard the Applications Technology Satellite (ATS) is provided. The 15 ampere hour nickel cadmium cells were manufactured by Gulton, 19 series connected cells per battery, and there are two batteries in each spacecraft. The operating design life was two years in a synchronous orbit, and a maximum depth of discharge of 50 percent. The design temperature for the batteries in the spacecraft was 0 to 25 C, and the charge control consisted of 1 volt versus temperature on a constant percentage voltage. Also, C/10 current limit, and a commandable trickle charge rate, using C/20 or C/60. The undervoltage was sent across a 9 cell and a 10 cell group, and it was set at one volt average per group on either group.

F E Ford

General Electric 20-ampere hour nickel-cadmium battery

The interaction, effect, and controllability of the performance parameters of the General Electric 20-ampere-hour, 24-cell nickel cadmium battery are investigated. The battery was cycled under simulated orbit conditions. The acquired data was analyzed and evaluated in terms of battery parameters and performance characteristics. Conclusions and tests results are presented along with recommendations for further study.

Kirsch, W. W.

The standard 20 AH battery

The modular power system, which is the first intended use for the NASA standard battery, is basically a four foot by four foot by eighteen inch box which can handle a complement of three 20 ampere hour batteries or later on the intended use is for three 50 ampere hour batteries to be the full complement. The system is designed to be used as a plug on component on a multi mission modular spacecraft. It has as a design point a basically 1250 watt orbital average load. The way it breaks up in a near earth orbit it would be somewhere around 1,000 watts for everything except 10 minutes, and during any 10 minute period it may go up to a peak of 3,000 watt load. Features of the battery reviewed include criteria to store electrical energy, the battery package, the covers and cases, and electrolytes. The capacities expected are 90 percent, the average cell capacity for 24 C, 90 percent of the actual battery capacity of 19 C, and 85 percent of the actual 25 degree battery capacity at zero discharge voltage for 50 percent DOD new battery is in the vicinity expected or predicted of 26.4 volts.

Zollner, M. T.

Design, Build and Qualification of 28 Volt Lithium-Ion battery

Contents include the following: 1. GSFC performance specifications requirements. 2. AEA philosophy: battery configuration. 3. AEA battery design: SONY cell, cell screening, 20Ah and 60Ah. 4. Testing: 20Ah battery qualification (environmental); 60Ah battery LEO life cycle. 5. Conclusion.: summary and lessons learned.

Curzon, D.

Life cycle test results of a bipolar nickel hydrogen battery

A history is given of low Earth orbit (LEO) laboratory test data on a 6.5 ampere-hour bipolar nickel hydrogen battery designed and built at the NASA Lewis Research Center. The bipolar concept is a means of achieving the goal of producing an acceptable battery, of higher energy density, able to withstand the demands of low-Earth-orbit regimes. Over 4100 LEO cycles were established on a ten cell battery. It seems that any perturbation on normal cycling effects the cells performance. Explanations and theories of the battery's behavior are varied and widespread among those closely associated with it. Deep discharging does provide a reconditioning effect and further experimentation is planned in this area. The battery watt-hour efficiency is about 75 percent and the time averaged, discharge voltage is about 1.26 volts for all cells at both the C/4 and LEO rate. Since a significant portion of the electrode capacity has degraded, the LEO cycle discharges are approaching depths of 90 to 100 percent of the high rate capacity. Therefore, the low end-of-discharge voltages occur precipitously after the knee of the discharge curve and is more an indication of electrode capacity and is a lesser indicator of overall cell performance.

Cataldo, R. L.

Ampere-Hour Meter For Rechargeable Battery

Low-power analog/digital electronic circuit meters discharge of storage battery in ampere-hours. By metering discharge, one obtains indication of state of charge of battery and avoids unnecessary recharging, maintaining capacity of battery and prolonging life. Because of its small size and low power consumption, useful in such applications as portable video cameras, communication equipment on boats, portable audio equipment, and portable medical equipment.

Tripp, John S.

In Flight Performance of a Six Ampere-hour Nickel-cadmium Battery in Low Earth Orbit

Flight data for 17,000 orbital cycles are reviewed and summarized. The nickel cadmium battery system operated without failure or abnormality. Battery trend analysis used in determining the feasibility of extending mission life is discussed. The life test data for 20% depth of discharge indicates design life requirements would be reached even at a deeper depth of discharge.

Mcdermott, J. K.

Pocket nickel cadmium cell and battery evaluation

The Nickel Cadmium 129-ampere hour cell was tested in order to characterize the cell under controlled conditions. Results of charge characterization and discharge characterization are reported. Ampere hour efficiency, open circuit stand, and cycle life operation results are included. The battery is briefly described.

Lear, J. W.

Long Life Molten Salt Battery for NASA Venus Application

A development program is being conducted at Advanced Thermal Batteries (ATB) to create a low discharge rate, long life, molten salt battery for a NASA Venus surface probe. Battery goals are 60 days continuous operation at +25V +0/-6 volts and -25V +6/-0 Volts under severe environments of 465°C, 92 atm pressure, and corrosive sulfur dioxide in a super critical carbon dioxide atmosphere. Conveniently, molten salt thermal battery electrochemistry starts to operate efficiently at 330°C. However, a major barrier to direct application of existing thermal battery technology is the high self-discharge rate, resulting in lifetimes in only minutes, not days. The best performance to date, which meets the required voltage regulation, has been a lithium silicon (LiSi) alloy anode discharging through all three voltage plateau versus an iron monosulfide (FeS) cathode. In order to perform reproducibly, additional engineering controls within the battery design are required to limit cell–to–cell parasitic discharge mechanisms. Results of these trials have improved the efficiency and manufacturability of the design.

Thermal Battery

Update of the IUE battery in-flight performance

The in-flight performance data of two 17-cell, 6-ampere-hour nickel cadmium spacecraft batteries are presented covering 22 months of operation. Fluctuations in the battery voltage and the battery temperature are presented for spacecraft movement throughout a beta range of 0 to 130 deg. The battery discharge voltages during the peak eclipse seasons, daily seasons, and daily eclipse periods are noted. Finally, the spacecraft data are compared to data from a 6-ampere-hour test pack and test flight data.

Tiller, S. E.

Microprocessor controlled advanced battery management systems

The advanced battery management system described uses the capabilities of an on-board microprocessor to: (1) monitor the state of the battery on a cell by cell basis; (2) compute the state of charge of each cell; (3) protect each cell from reversal; (4) prevent overcharge on each individual cell; and (5) control dual rate reconditioning to zero volts per cell.

W. T. Payne

Solar Array Arcing in Plasmas

Solar cells in space plasma conditions are known to arc into the plasma when the interconnects are at a negative potential of a few hundred volts, relative to plasma potential. For cells with silver-coated interconnects, a threshold voltage for arcing exists at about -230 V, as found in both ground and LEO experiments. The arc rate beyond the threshold voltage depends nearly linearly on plasma density, but has a strong power-law dependence on voltage, such that for small increments in operating voltage there is a large increment in arc rate. The arcs generate broadband radio interference and visible light. In ground tests, interconnects have been damaged by arcs in cells having insufficient isolation from a source of high current. Models for the arcs are highly dependent on the choice of interconnect conductor material exposed to the plasma and possibly on the geometry and choice of adjacent insulator material. Finally, new technology solar cells use copper for the cell interconnects, a material which may have a lower arcing threshold voltage than silver. It is expected, from ground tests of simulated solar cells, that any junction of conductor and insulator exposed to space plasma conditions will arc into the plasma at a few hundred volts negative potential, relative to the local plasma.

Dale C Ferguson

Orbiting Astronomical Observatory Battery and Power System Design

The battery design of OAO-C (OAO-3) is given and consists of three-20 ampere hour 22 series connected cells in the battery. There are three batteries per spacecraft. The packaging configuration is described. The charging-discharging operations and the voltage potential of the battery system are discussed. Graphs are presented for the voltage limits (battery voltage versus temperature) and end of dark voltages (battery voltage versus ampere-hours discharged) of the battery system used on OAO-3. Data tables are also presented which give a summary of the battery performance and a comparison of OAO-3 with OAO A-2.

F E Ford

Battery charge-discharge controller

Charge-discharge controller contains punched-tape programmer capable of programming 305 discrete steps in the battery load. The indicating instrumentation includes meters for ampere-hours, watt-hours, voltage, current, and internal temperature and pressure. It also generates analog signals for recording the displayed data.

Ciccanti, A. D.