Search NASA⌕ Search

SEARCH · Search NASA

Results for “VULCAN FACILITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An Automated DAKOTA and VULCAN-CFD Framework with Application to Supersonic Facility Nozzle Flowpath Optimization

Removing human interaction from design processes by using automation may lead to gains in both productivity and design precision. This memorandum describes efforts to incorporate high fidelity numerical analysis tools into an automated framework and applying that framework to applications of practical interest. The purpose of this effort was to integrate VULCAN-CFD into an automated, DAKOTA-enabled framework with a proof-of-concept application being the optimization of supersonic test facility nozzles. It was shown that the optimization framework could be deployed on a high performance computing cluster with the flow of information handled effectively to guide the optimization process. Furthermore, the application of the framework to supersonic test facility nozzle flowpath design and optimization was demonstrated using multiple optimization algorithms.

Axdahl, Erik L.↗

Molecular films associated with LDEF

The molecular films deposited on the surface of the Long Duration Exposure Facility (LDEF) originated from the paints and room-temperature-vulcanized (RTV) silicone materials intentionally used on the satellite and not from residual contaminants. The high silicone content of most of the films and the uniformity of the films indicates a homogenization process in the molecular deposition and suggests a chemically most favored composition for the final film. The deposition on interior surfaces and vents indicated multiple bounce trajectories or repeated deposition-reemission cycles. Exterior surface deposits indicated a significant return flux. Ultraviolet light exposure was required to fix the deposited film as is indicated by the distribution of the films on interior surfaces and the thickness of films at the vent locations. Thermal conditions at the time of exposure to ultraviolet light seems to be an important factor in the thickness of the deposit. Sunrise facing (ram direction) surfaces always had the thicker film. These were the coldest surfaces at the time of their exposure to ultraviolet light. The films have a layered structure suggesting cyclic deposition. As many as 34 distinct layers were seen in the films. The cyclic nature of the deposition and the chemical uniformity of the film one layer to the next suggest an early deposition of the films though there is evidence for the deposition of molecular films throughout the nearly six year exposure of the satellite. A final 'spray' of an organic material associated with water soluble salts occurred very late in the mission. This may have been the result of one of the shuttle dump activities.

Crutcher, E. R.↗

A Modified Wall Matching Treatment to Account for Local Solid to Fluid Thermal Coupling

The wall-matching methodology of Wilcox is modified to include a solid-wall, thermal-conduction model. This coupled fluid-thermal-structure model is derived assuming that the wall thermal-structure behavior is locally one-dimensional and that structural deformations, due to thermally induced stresses, are not significant. The one-dimensional coupled fluid-thermal-structure model is derived such that the wall temperature is removed as an independent boundary condition variable. The one-dimensional coupled fluid-thermal-structure model is also derived for the general case of an arbitrary mixture of thermally prefect gases and a wall of arbitrary thickness and conductivity by using a compressible, streamwise-pressure-gradient-corrected, wall-matching function and Fourier's law of heat conduction. The resulting model was implemented in the VULCAN CFD code as a new boundary condition type. VULCAN was then used to simulate a two-dimensional Mach 6 wind tunnel facility nozzle flow to demonstrate/validate the one-dimensional coupled fluid-thermal-structure model. The nozzle internal-wall surface temperature and heat transfer distributions computed using the one-dimensional coupled fluid-thermal-structure model are compared to wall temperature and heat transfer distributions from an iterative multi-dimensional analysis obtained by coupling the VULCAN CFD code and the MSC/NASTRAN-thermal code. The one-dimensional coupled fluid-thermal-structure model analysis is shown to be very robust and in excellent agreement with the multi-dimensional iteratively coupled analysis. It is also shown that the one-dimensional analysis can be used as an initial guess for the multi-dimensional iteratively coupled analysis.

White, Jeffery A.↗

A Modified Wall Matching Treatment to Account for Local Solid to Fluid Thermal Coupling

The wall-matching methodology of Wilcox is modified to include a solid-wall, thermal-conduction model. This coupled fluid-thermal-structure model is derived assuming that the wall thermal-structure behavior is locally one-dimensional and that structural deformations, due to thermally induced stresses, are not significant. The one-dimensional coupled fluid-thermal-structure model is derived such that the wall temperature is removed as an independent boundary condition variable. The one-dimensional coupled fluid-thermal-structure model is also derived for the general case of an arbitrary mixture of thermally prefect gases and a wall of arbitrary thickness and conductivity by using a compressible, streamwise-pressure-gradient-corrected, wall-matching function and Fourier's law of heat conduction. The resulting model was implemented in the VULCAN CFD code as a new boundary condition type. VULCAN was then used to simulate a two-dimensional Mach 6 wind tunnel facility nozzle flow to demonstrate/validate the one-dimensional coupled fluid-thermal-structure model. The nozzle internal-wall surface temperature and heat transfer distributions computed using the one-dimensional coupled fluid-thermal-structure model are compared to wall temperature and heat transfer distributions from an iterative multi-dimensional analysis obtained by coupling the VULCAN CFD code and the MSC/NASTRAN-thermal code. The one-dimensional coupled fluid-thermal-structure model analysis is shown to be very robust and in excellent agreement with the multi-dimensional iteratively coupled analysis. It is also shown that the one-dimensional analysis can be used as an initial guess for the multi-dimensional iteratively coupled analysis.

White, Jeffery A.↗

Studies on Stress-Strain Relationships of Polymeric Materials Used in Space Applications

A two-year research plan was undertaken in association with Polymers Branch, NASA Glenn Research Center, to carry out experimental and modeling work relating stress and strain behavior of polymeric materials, especially elastomers and vulcanized rubber. An experimental system based on MTS (Mechanical Testing and Simulation) A/T-4 test facility environment has been developed for a broader range of polymeric materials in addition to a design of laser compatible temperature control chamber for online measurements of various strains. Necessary material processing has been accomplished including rubber compounding and thermoplastic elastomer processing via injection molding. A broad suite of testing methodologies has been identified to reveal the complex non-linear mechanical behaviors of rubbery materials when subjected to complex modes of deformation. This suite of tests required the conceptualization, design and development of new specimen geometries, test fixtures, and test systems including development of a new laser based technique to measure large multi-axial deformations. Test data has been generated for some of these new fixtures and has revealed some complex coupling effects generated during multi-axial deformations. In addition, fundamental research has been conducted concerning the foundation principles of rubber thermodynamics and resulting theories of rubber elasticity. Studies have been completed on morphological properties of several thermoplastic elastomers. Finally, a series of steps have been identified to further advance the goals of NASA's ongoing effort.

Jana, Sadhan C.↗

Qualification test of the Ross Double Planetary Mixer

This test report describes the qualification test of the Ross Double Planetary Mixer used to mix room temperature vulcanized (RTV) silicone (Dow Corning 90-006-2) for the redesigned solid rocket motor (RSRM) nozzle joints. Testing was completed 18 June 1993 in the M-113A Nozzle Fabrication Facility at Thiokol Corporation, Space Operations, Brigham City, Utah. The Ross mixer provides better mixing and better control on temperature and humidity, resulting in better quality RTV and a longer usable pot life. The test began on 3 May 1993 and was stopped due to operator error during the tensile strength and elongation testing. Specimens were ruined without gathering any useful data. A 'no test' was declared, the problem was remedied, and the test was re-run with MSFC approval. The test was run and all pass/fail criteria were met, most with a considerable margin. The Ross Double Planetary Mixer met all certification objectives and is recommended for immediate use for mixing RTV silicone for RSRM nozzle joints.

Lueders, Kurt F.↗

Fundamental Mixing and Combustion Experiments for Propelled Hypersonic Flight

The first experiment is a study of a coaxial jet discharging into stagnant laboratory air, with center jet of a mixture of 5% oxygen and 95% helium by volume and coflow jet of air. The exit flow pressure of both center-jet and coflow nozzles is 1 atmosphere. The presence of oxygen in the center jet is to allow the use of an oxygen flow-tagging technique (RELIEF4) to obtain non-intrusive velocity measurements. Both jets are nominally Mach 1.8, but, because of the greater speed of sound, the center jet velocity is more than twice that of the coflow. The mixing layer which forms between the center jet and the coflow near the nozzle exit is compressible, with a calculated convective Mach number of approximately 0.7. This geometry has several advantages: The streamwise development of the flow is generally dominated by turbulent stresses (rather than pressure forces), and thus calculations are sensitive to turbulence modeling. It includes features present in supersonic combustors, including a compressible mixing layer near the nozzle exit and a light-gas/air plume downstream. Since it is a free jet, it provides easy access for both optical instrumentation and probes. Since it is axisymmetric, it requires fewer experimental measurements to fully characterize, and calculations can be performed with more modest computer resources. However, weak shock waves formed at the nozzle exit strengthen and turn normal as they approach the axis, complicating the flow. Care is thus taken in the design of the facility to provide as near as possible to 1-D flow at the exit of both center and coflow nozzles, and to minimize the strength of waves generated at the nozzle exit. Results from this experiment are compared to CFD solutions obtained by VULCAN, a previously developed code used in engine analysis. The second experiment is a study of a supersonic combustor consisting of a diverging duct with single downstream-angled wall injector. Thus, the geometry is relatively simple and large regions of subsonic recirculating flow are avoided. The nominal entrance Mach number is 2 and the enthalpy of the test gas (hot air "simulant") is nominally that of Mach 7 flight. It was believed, on the basis of calculations performed that this would produce mixing-limited flow, that is to say, one for which chemical reaction to equilibrium proceeds at a much greater rate than mixing. It later proved that this was not the case. The primary experimental technique employed is coherent anti-Stokes Raman spectroscopy, known by its acronym CARS. The species probed is molecular nitrogen and the quantity measured is temperature. Intrusive probes, such as Pitot, total temperature, hot-wire, etc., are not used due to access difficulty and high heat flux in the combustor, and because they may alter the flow. CARS has several advantages over other optical methods. It is a relatively mature and well-understood technique. Signal levels are relatively high and the signal is in the form of a coherent (laser) beam that can be collected through small windows. Incoherent (non-CARS) interferences are rejected by spatial filtering.

Diskin, G. S.↗

The Enhanced Injection and Mixing Project at NASA Langley

An overview of a research project aimed at enhancing fuel injection and mixing for scramjet engines at flight Mach numbers greater than 8 is presented. The specific objectives of this project are to increase knowledge and understanding of the fundamental physics governing scramjet fuel-air mixing, to develop strategies for improving injector performance and to develop functional relationships between mixing efficiency, losses due to mixing (such as total pressure loss, drag) and combustor/mixing length. The research approach consists of a closely coupled experimental and computational effort with experiments intended for exploring injection concepts and for anchoring computational fluid dynamics (CFD) simulations. The experiments are being conducted in the NASA Langley Arc-Heated Scramjet Test Facility and consist of helium injection into a Mach 6 air stream. Measurements include in-stream helium mole fraction, Pitot pressure, and total temperature as well as wall pressures and temperatures. Additionally, nitric oxide planar laser-induced fluorescence (NO PLIF) imaging will be used for flow visualization of the fuel plume. The numerical simulations, performed with the VULCAN CFD code, provide flowfield details unobtainable from the experiment. The current paper describes the experimental apparatus and diagnostic systems which have been developed and/or tested in preparation for the mixing tests and discusses numerical simulations performed to reduce the risk associated with the experimental design.

K F Cabell↗

Simulations of the Modular Axisymmetric Scramjet Test Rig Under Reacting Flow Conditions

Simulations of the Air Force Research Laboratory (AFRL) Modular Axisymmetric Scramjet Test Rig (MASTeR) are presented. MASTeR is a parametric test article capable of investigating various scramjet cavity flameholder designs and fueling strategies with the goal to characterize and optimize flameholding capability. In the current work, three cavity aspect ratios, and two fueling strategies (upstream and in-cavity) with ethylene at a nominal facility pressure and temperature condition are evaluated. The reacting simulations are performed, and the resulting flow characteristics are discussed. For each configuration and fueling strategy, cavity residence time, entrainment rate, and fuel-air equivalence ratio are computed. The MASTeR geometry is defined in Engineering Sketch Pad (ESP) and the simulations use a sketch-to-solution (S2S) automated unstructured grid adaptation tool in VULCAN-CFD. This tool automatically generates a simulation grid from the ESP geometry and systematically adapts it to the numerical solution based on the Hessian error estimate of a specified flow field parameter. Reynolds averaged simulations (RAS) are used with a two-equation linear eddy viscosity and diffusivity model. The resulting database can be compared with the experimental data as those become available, and explored to develop models for cavity performance for scramjet propulsion design applications.

hypersonics↗

An Experimental and CFD Study of a Supersonic Coaxial Jet

A supersonic coaxial jet facility is designed and experimental data are acquired suitable for the validation of CFD codes employed in the analysis of high-speed air-breathing engines. The center jet is of a light gas, the coflow jet is of air, and the mixing layer between them is compressible. The jet flow field is characterized using schlieren imaging, surveys with pitot, total temperature and gas sampling probes, and RELIEF velocimetry. VULCAN, a structured grid CFD code, is used to solve for the nozzle and jet flow, and the results are compared to the experiment for several variations of the kappa - omega turbulence model

Cutler, A. D.↗

Simulations of the Modular Axisymmetric Scramjet Test Rig Under Reacting Flow Conditions

Simulations of the Air Force Research Laboratory (AFRL) Modular Axisymmetric Scramjet Test Rig (MASTeR) are presented. MASTeR is a parametric test article capable of investigating various scramjet cavity flameholder designs and fueling strategies with the goal to characterize and optimize flameholding capability. In the current work, three cavity aspect ratios, three depths, and two fueling strategies (upstream and in-cavity) with ethylene at a nominal facility pressure and temperature conditions are evaluated. The simulations are performed for mixing-only and reacting flows, and the resulting flow characteristics are compared. For each configuration and fueling strategy, cavity residence time, entrainment rate, and fuel-air equivalence ratio are computed. The MASTeR geometry is defined in the Engineering Sketch Pad (ESP) and the simulations use a sketch-to-solution (S2S) automated unstructured grid adaptation tool in VULCAN-CFD. This tool automatically generates a simulation grid from the ESP geometry and systematically adapts it to the numerical solution based on the Hessian error estimate of a specified flow field parameter. Reynolds averaged simulations (RAS) are used with typical two-equation linear eddy viscosity and diffusivity model. The resulting database can be compared with the experimental data as those becomes available and explored to develop models for cavity performance for scramjet propulsion design applications.

hypersonics↗

Spatially and Temporally Resolved Measurements of Velocity in a H2-air Combustion-Heated Supersonic Jet

This paper presents simultaneous measurements at multiple points of two orthogonal components of flow velocity using a single-shot interferometric Rayleigh scattering (IRS) technique. The measurements are performed on a large-scale Mach 1.6 (Mach 5.5 enthalpy) H2-air combustion jet during the 2007 test campaign in the Direct Connect Supersonic Combustion Test facility at NASA Langley Research Center. The measurements are performed simultaneously with CARS (Coherent Anti-stokes Raman Spectroscopy) using a combined CARS-IRS instrument with a common path 9-nanosecond pulsed, injection-seeded, 532-nm Nd:YAG laser probe pulse. The paper summarizes the measurements of velocities along the core of the vitiated air flow as well as two radial profiles. The average velocity measurement near the centerline at the closest point from the nozzle exit compares favorably with the CFD calculations using the VULCAN code. Further downstream, the measured axial velocity shows overall higher values than predicted with a trend of convergence at further distances. Larger discrepancies are shown in the radial profiles.

Bivolaru, Daniel↗

Automation of the Uncertainty Quantification Process Based on Probability Boxes with DAKOTA

To date, while the use of CFD is prevalent, very few efforts have been undertaken that truly attempt to document all (or even most) of the sources of uncertainty in the simulations. Instead, the current state-of-the-art relies heavily on the experience of the CFD practitioner to estimate the uncertainty associated with their simulations through simple sensitivity studies or subject matter expertise. This practice will have to be replaced with a formal uncertainty quantification (UQ) process if CFD is to play an expanded role in the design research and engineering community, test and evaluation community, and ultimately certification for flight. This is especially true for hypersonic air-breathing propulsion systems due to the environment, scale, and duration limitations of ground test facilities. Accounting for uncertainties in a formal manner is a tedious process. Moreover, the typical CFD practitioner is not likely to be familiar with formal UQ methods. Hence, a major obstacle that has prevented the adoption of UQ methods for engineering design and development work is the lack of a tool set to automate most (if not all) of the UQ workflow. Towards this end, the SANDIA package DAKOTA (which has been developed to drive both UQ and optimization processes) will be tightly wrapped around the VULCAN-CFD code to automate the uncertainty quantification process. The automated process will be applied to an isolator turbulence model validation exercise that has previously been documented using a manual approach to the UQ process. Hence, the focus of this paper will be documenting the level to which automation can hide the UQ process details from the CFD practitioner rather than the UQ method itself.

CFD↗

Reynolds-Averaged Turbulence Model Assessment for a Highly Back-Pressured Isolator Flowfield

The use of computational fluid dynamics in scramjet engine component development is widespread in the existing literature. Unfortunately, the quantification of model-form uncertainties is rarely addressed with anything other than sensitivity studies, requiring that the computational results be intimately tied to and calibrated against existing test data. This practice must be replaced with a formal uncertainty quantification process for computational fluid dynamics to play an expanded role in the system design, development, and flight certification process. Due to ground test facility limitations, this expanded role is believed to be a requirement by some in the test and evaluation community if scramjet engines are to be given serious consideration as a viable propulsion device. An effort has been initiated at the NASA Langley Research Center to validate several turbulence closure models used for Reynolds-averaged simulations of scramjet isolator flows. The turbulence models considered were the Menter BSL, Menter SST, Wilcox 1998, Wilcox 2006, and the Gatski-Speziale explicit algebraic Reynolds stress models. The simulations were carried out using the VULCAN computational fluid dynamics package developed at the NASA Langley Research Center. A procedure to quantify the numerical errors was developed to account for discretization errors in the validation process. This procedure utilized the grid convergence index defined by Roache as a bounding estimate for the numerical error. The validation data was collected from a mechanically back-pressured constant area (1 2 inch) isolator model with an isolator entrance Mach number of 2.5. As expected, the model-form uncertainty was substantial for the shock-dominated, massively separated flowfield within the isolator as evidenced by a 6 duct height variation in shock train length depending on the turbulence model employed. Generally speaking, the turbulence models that did not include an explicit stress limiter more closely matched the measured surface pressures. This observation is somewhat surprising, given that stress-limiting models have generally been developed to better predict shock-separated flows. All of the models considered also failed to properly predict the shape and extent of the separated flow region caused by the shock boundary layer interactions. However, the best performing models were able to predict the isolator shock train length (an important metric for isolator operability margin) to within 1 isolator duct height.

Baurle, Robert A.↗

Progress Towards Modeling the Mars Science Laboratory PICA-NuSil Heatshield

The data collected by the Mars Science Laboratory (MSL) Entry, Descent and Landing Instrumentation, MEDLI, have become an established reference to assess the performance of engineering models of the Phenolic Impregnated Carbon Ablator (PICA) and to validate hypersonic computational fluid dynamics (CFD) tools for entry systems. MEDLI measurements are also extensively used as validation reference for current developments of high-fidelity material response models for PICA. So large has been the scientific output and impact of MEDLI that a follow-up instrumentation suite MEDLI2 is underway for the upcoming Mars 2020 mission.A feature neglected thus far in the modeling of the MSL heatshield, is the presence of a silicone-based room temperature vulcanizing coating designated NuSil CV-1144-0. NuSil was used to coat the entire MSL heatshield, including the MEDLI plugs, to mitigate the spread of phenolic dust from PICA, and limit contamination during clean room operations. NuSil CV-1144-0 is a space grade siloxane copolymer, designed as an oxygen protection barrier for extreme low temperature environment.Assessments conducted during MSL development demonstrated that the presence of NuSil had no adverse effect on the performance of PICA. However, evidence from ground testing of PICA-NuSil (PICA-N) models in the HyMETS arc-jet test facility suggests that the silicone changes the high temperature response of PICA. It is therefore critical to assess the importance of modeling the coating in ongoing code validation efforts.

Bessire, Brody K.↗

Comparisons Between NO PLIF Imaging and CFD Simulations of Mixing Flowfields for High-Speed Fuel Injectors

The current work compares experimentally and computationally obtained nitric oxide (NO) planar laser-induced fluorescence (PLIF) images of the mixing flowfields for three types of high-speed fuel injectors: a strut, a ramp, and a rectangular flush-wall. These injection devices, which exhibited promising mixing performance at lower flight Mach numbers, are currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. The EIMP aims to investigate scramjet fuel injection and mixing physics, and improve the understanding of underlying physical processes relevant to flight Mach numbers greater than eight. In the experiments, conducted in the NASA Langley Arc-Heated Scramjet Test Facility (AHSTF), the injectors are placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number air flow at the entrance of a scramjet combustor. Helium is used as an inert substitute for hydrogen fuel. The PLIF is obtained by using a tunable laser to excite the NO, which is present in the AHSTF air as a direct result of arc-heating. Consequently, the absence of signal is an indication of pure helium (fuel). The PLIF images computed from the computational fluid dynamics (CFD) simulations are obtained by combining a fluorescence model for NO with the Reynolds-Averaged Simulation results carried out using the VULCAN-CFD solver to obtain a computational equivalent of the experimentally measured PLIF signal. The measured NO PLIF signal is mainly a function of NO concentration allowing for semi-quantitative comparisons between the CFD and the experiments. The PLIF signal intensity is also sensitive to pressure and temperature variations in the flow, allowing additional flow features to be identified and compared with the CFD. Good agreement between the PLIF and the CFD results provides increased confidence in the CFD simulations for investigations of injector performance.

Drozda, Tomasz, G.↗

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

RTV↗

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

silicone intumescence↗