Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vacuum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

National Synchrotron Light Source II storage ring vacuum systems

The National Synchrotron Light Source II, completed in 2014, is a 3-GeV synchrotron radiation (SR) facility at Brookhaven National Laboratory and has been in steady operation since. With a design electron current of 500 mA and subnanometer radians horizontal emittance, this 792-m circumference storage ring is providing the highest flux and brightness x-ray beam for SR users. The majority of the storage ring vacuum chambers are made of extruded aluminium. Chamber sections are interconnected using low-impedance radiofrequency shielded bellows. SR from the bending magnets is intercepted by water-cooled compact photon absorbers resided in the storage ring chambers. This paper presents the design of the storage ring vacuum system, the fabrication of vacuum chambers and other hardware, the installation, the commissioning, and the continuing beam conditioning of the vacuum systems.

43 PARTICLE ACCELERATORS↗

Origin of electrons emitted into vacuum from InGaN light emitting diodes

The mechanism responsible for efficiency droop in InGaN light-emitting diodes (LEDs) has long been elusive due to indirect measurement techniques used for its identification. Auger recombination is unique among proposed efficiency droop mechanisms, in that it is the only mechanism capable of generating hot carriers. In a previous study [J. Iveland et al., Phys. Rev. Lett. 110, 177406 (2013)], we performed electron energy analysis of electrons emitted into vacuum from a forward biased InGaN LED that had been brought into negative electron affinity by cesiation. Three peaks were observed in the energy spectrum of vacuum emitted electrons. In this Letter, we unambiguously identify the origin of the peaks. The two higher energy peaks correspond to accumulation of electrons transported to the surface in the bulk Γ and side L conduction band valleys. The L-valley peak is a direct signature of a hot Auger electron population. The lower energy peak results from surface photoemission induced by the internal LED light emitted from the InGaN quantum wells. Two control experiments were performed. In the first, a simple GaN pn junction generated only a single Γ peak in electroemission. In the second, selective detection of the photoemission from an LED under modulated light excitation and DC electrical injection confirms that only the low energy peak is photogenerated and that LED light is incapable of generating Γ or L-valley peaks, the latter only occurring due to the Auger effect in the LED active region.

42 ENGINEERING↗

Quark Fragmentation in the {theta} Vacuum

QCD vacuum is a superposition of degenerate states with different topological numbers that are connected by tunneling (the {theta} vacuum). The tunneling events are due to configurations of gauge fields (e.g., the instantons) that induce local P-odd domains in Minkowski space-time. We study the quark fragmentation in this topologically nontrivial QCD background. We find that even though QCD globally conserves P and CP symmetries, two new kinds of P-odd fragmentation functions emerge. We study their experimental manifestations in dihadron production in e{sup +}e{sup -} collisions, and find two interesting dihadron correlations: the cos({phi}{sub 1}+{phi}{sub 2}) correlation usually referred to as the Collins effect, and a P-odd {approx}sin({phi}{sub 1}+{phi}{sub 2}) correlation that vanishes in the cross section summed over many events, but survives on the event-by-event basis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DETERMINATION OF IONIZATION ENERGIES OF C {sub n} N (n = 4-12): VACUUM ULTRAVIOLET PHOTOIONIZATION EXPERIMENTS AND THEORETICAL CALCULATIONS

Results from single photon vacuum ultraviolet photoionization of astrophysically relevant C{sub n} N clusters, n = 4-12, in the photon energy range of 8.0 eV-12.8 eV are presented. The experimental photoionization efficiency curves, combined with electronic structure calculations, provide improved ionization energies of the C{sub n} N species. A search through numerous nitrogen-terminated C{sub n} N isomers for n = 4-9 indicates that the linear isomer has the lowest energy, and therefore should be the most abundant isomer in the molecular beam. Comparison with calculated results also shed light on the energetics of the linear C{sub n} N clusters, particularly in the trends of the even-carbon and the odd-carbon series. These results can guide the search of potential astronomical observations of these neutral molecules together with their cations in highly ionized regions or regions with a high UV/VUV photon flux (ranging from the visible to VUV with flux maxima in the Lyman-{alpha} region) in the interstellar medium.

79 ASTRONOMY AND ASTROPHYSICS↗

Real-time radiative divertor feedback control development for the NSTX-U tokamak using a vacuum ultraviolet spectrometer

A radiative divertor technique is planned for the NSTX-U tokamak to prevent excessive erosion and thermal damage of divertor plasma-facing components in H-mode plasma discharges with auxiliary heating up to 12 MW. In the radiative (partially detached) divertor, extrinsically seeded deuterium or impurity gases are used to increase plasma volumetric power and momentum losses. A real-time feedback control of the gas seeding rate is planned for discharges of up to 5 s duration. The outer divertor leg plasma electron temperature T{sub e} estimated spectroscopically in real time will be used as a control parameter. A vacuum ultraviolet spectrometer McPherson Model 251 with a fast charged-coupled device detector is developed for temperature monitoring between 5 and 30 eV, based on the Δn = 0, 1 line intensity ratios of carbon, nitrogen, or neon ion lines in the spectral range 300–1600 Å. A collisional-radiative model-based line intensity ratio will be used for relative calibration. A real-time T{sub e}-dependent signal within a characteristic divertor detachment equilibration time of ∼10–15 ms is expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An ultra-high vacuum chamber for scattering experiments featuring in-vacuum continuous in-plane variation of the angle between entrance and exit vacuum ports

A concept that enables in-vacuum continuous variation of the angle between two ports in one plane has been developed and implemented. The vacuum chamber allows for measuring scattering cross sections as a function of scattering angle and is intended for resonant inelastic X-ray scattering experiments. The angle between the ports can be varied in the range of 30°-150°, while the pressure change is less than 2 × 10{sup −10} mbars.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The near vacuum hohlraum campaign at the NIF: A new approach

The near vacuum campaign on the National Ignition Facility has concentrated its efforts over the last year on finding the optimum target geometry to drive a symmetric implosion at high convergence ratio (30x). As the hohlraum walls are not tamped with gas, the hohlraum is filling with gold plasma and the challenge resides in depositing enough energy in the hohlraum before it fills up. Hohlraum filling is believed to cause symmetry swings late in the pulse that are detrimental to the symmetry of the hot spot at high convergence. This paper describes a series of experiments carried out to examine the effect of increasing the distance between the hohlraum wall and the capsule (case to capsule ratio) on the symmetry of the hot spot. These experiments have shown that smaller Case to Capsule Ratio (CCR of 2.87 and 3.1) resulted in oblate implosions that could not be tuned round. Larger CCR (3.4) led to a prolate implosion at convergence 30x implying that inner beam propagation at large CCR is not impeded by the expanding hohlraum plasma. A Case to Capsule ratio of 3.4 is a promising geometry to design a round implosion but in a smaller hohlraum where the hohlraum losses are lower, enabling a wider cone fraction range to adjust symmetry.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A highly miniaturized vacuum package for a trapped ion atomic clock

We report on the development of a highly miniaturized vacuum package for use in an atomic clock utilizing trapped ytterbium-171 ions. The vacuum package is approximately 1 cm{sup 3} in size and contains a linear quadrupole RF Paul ion trap, miniature neutral Yb sources, and a non-evaporable getter pump. We describe the fabrication process for making the Yb sources and assembling the vacuum package. To prepare the vacuum package for ion trapping, it was evacuated, baked at a high temperature, and then back filled with a helium buffer gas. Once appropriate vacuum conditions were achieved in the package, it was sealed with a copper pinch-off and was subsequently pumped only by the non-evaporable getter. We demonstrated ion trapping in this vacuum package and the operation of an atomic clock, stabilizing a local oscillator to the 12.6 GHz hyperfine transition of {sup 171}Y b{sup +}. The fractional frequency stability of the clock was measured to be 2 × 10{sup −11}/τ{sup 1/2}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electroweak vacuum instability and renormalized Higgs field vacuum fluctuations in the inflationary universe

In this work, we investigated the electroweak vacuum instability during or after inflation. In the inflationary Universe, i.e., de Sitter space, the vacuum field fluctuations < δ φ {sup 2} > enlarge in proportion to the Hubble scale H {sup 2}. Therefore, the large inflationary vacuum fluctuations of the Higgs field < δ φ {sup 2} > are potentially catastrophic to trigger the vacuum transition to the negative-energy Planck-scale vacuum state and cause an immediate collapse of the Universe. However, the vacuum field fluctuations < δ φ {sup 2} >, i.e., the vacuum expectation values have an ultraviolet divergence, and therefore a renormalization is necessary to estimate the physical effects of the vacuum transition. Thus, in this paper, we revisit the electroweak vacuum instability from the perspective of quantum field theory (QFT) in curved space-time, and discuss the dynamical behavior of the homogeneous Higgs field φ determined by the effective potential V {sub eff}( φ ) in curved space-time and the renormalized vacuum fluctuations < δ φ {sup 2} >{sub ren} via adiabatic regularization and point-splitting regularization. We simply suppose that the Higgs field only couples the gravity via the non-minimal Higgs-gravity coupling ξ(μ). In this scenario, the electroweak vacuum stability is inevitably threatened by the dynamical behavior of the homogeneous Higgs field φ, or the formations of AdS domains or bubbles unless the Hubble scale is small enough H < Λ {sub I} .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Organic Vacuum Pump Fluids for the Vacuum Pumping of Fusion Power Plants

Vacuum pumps are the heart of the fusion fuel cycle, but most currently proposed pumping technologies are not capable of handling the required flow rates and vacuum pressures. Oil-containing vacuum pumps can readily meet the flow requirements, but vacuum fluids will degrade in fusion-relevant environments due to contact with tritium and exposure to high-energy radiation. Here, in this study, we describe a methodology to screen vacuum fluid candidates and purify these candidate fluids post oxidation, post exposure to deuterium, and post exposure to gamma radiation (<7.5 MGy) to simulate a process in which vacuum fluids can be recovered and regenerated during the fusion fuel cycle. A series of oils, including a highly purified mineral oil, phenyl silicone oil, and a polyphenyl ether, are shown to be suitable candidates for vacuum pumping. Additionally, we describe a simple purification methodology to remove oxidized functionalities and the associated isotopologues induced by contact with deuterium from the candidate vacuum fluids This purification methodology can also be applied to radiological damage with moderate effect. Finally, we demonstrate that the sorbents can be regenerated through electromagnetic microwave digestion.

oxidation↗

Viability of Cladosporium herbarum spores under 157 nm laser and vacuum ultraviolet irradiation, low temperature (10 K) and vacuum

Ultraviolet photons can damage microorganisms, which rarely survive prolonged irradiation. In addition to the need for intact DNA, cell viability is directly linked to the functionality of the cell wall and membrane. In this work, Cladosporium herbarum spore monolayers exhibit high viability (7%) when exposed to 157 nm laser irradiation (412 kJm⁻²) or vacuum-ultraviolet irradiation (110–180 nm) under standard pressure and temperature in a nitrogen atmosphere. Spore viability can be determined by atomic-force microscopy, nano-indentation, mass, μ-Raman and attenuated reflectance Fourier-transform far-infrared spectroscopies and DNA electrophoresis. Vacuum ultraviolet photons cause molecular damage to the cell wall, but radiation resistance in spores arises from the activation of a photon-triggered signaling reaction, expressed via the exudation of intracellular substances, which, in combination with the low penetration depth of vacuum-ultraviolet photons, shields DNA from radiation. Resistance to phototoxicity under standard conditions was assessed, as was resistance to additional environmental stresses, including exposure in a vacuum, under different rates of change of pressure during pumping time and low (10 K) temperatures. Vacuum conditions were far more destructive to spores than vacuum-ultraviolet irradiation, and UV-B photons were two orders of magnitude more damaging than vacuum-ultraviolet photons. The viability of irradiated spores was also enhanced at 10 K. This work, in addition to contributing to the photonic control of the viability of microorganisms exposed under extreme conditions, including decontamination of biological warfare agents, outlines the basis for identifying bio-signaling in vivo using physical methodologies.

36 MATERIALS SCIENCE↗

Electromagnetic vacuum of complex media: Dipole emission versus light propagation, vacuum energy, and local field factors

We offer a unified approach to several phenomena related to the electromagnetic vacuum of a complex medium made of point electric dipoles. To this aim, we apply the linear response theory to the computation of the polarization field propagator and study the spectrum of vacuum fluctuations. The physical distinction among the local density of states which enter the spectra of light propagation, total dipole emission, coherent emission, total vacuum energy, and Schwinger-bulk energy is made clear. Analytical expressions for the spectrum of dipole emission and for the vacuum energy are derived. Their respective relations with the spectrum of external light and with the Schwinger-bulk energy are found. The light spectrum and the Schwinger-bulk energy are determined by the Dyson propagator. The emission spectrum and the total vacuum energy are determined by the polarization propagator. An exact relationship of proportionality between both propagators is found in terms of local field factors. A study of the nature of stimulated emission from a single dipole is carried out. Regarding coherent emission, it contains two components. A direct one which is transferred radiatively and directly from the emitter into the medium and whose spectrum is that of external light. And an indirect one which is radiated by induced dipoles. The induction is mediated by one (and only one) local field factor. Regarding the vacuum energy, we find that in addition to the Schwinger-bulk energy the vacuum energy of an effective medium contains local field contributions proportional to the resonant frequency and to the spectral line width.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vacuum insulated glazing, valve, flexible seal, and method for making vacuum insulated glazing

A vacuum insulated glazing includes first and second spaced apart glass panes having perimeter portions defining a vacuum space between the glass panes. A vacuum valve is positioned at the perimeter portions of the glass panes and includes a valve body extending between the perimeter portions of the glass panes, and having first and second ends and a fluid conduit extending from the first end to the second end of the valve body and in fluid communication with the vacuum space. A one-way valve in the fluid conduit permits fluid flow from the vacuum space, and prevents fluid flow into the vacuum space. A suction fitting is provided for connecting the valve body to a suction device. An end seal between the perimeter portions of the glass panes is provided for hermetically sealing the vacuum space. A valve for a VIG and a method of making a VIG are also disclosed.

Bhandari, Mahabir↗