Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vacuum glazing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Effects of pillar design on the thermal performance of vacuum-insulated glazing

Vacuum-insulated glazing (VIG) with a low-emittance coating has a great market potential as an effective transparent insulator. The thermal insulating performance of VIG is determined by its design, including material selection and configuration of different components. Thermal conductance of the vacuum gap as a transport bottleneck is one of the primary factors controlling the thermal transport across VIG. In particular, because support pillars provide the main thermal transport channels across the vacuum gap, increasing the pillar thermal resistance is a key strategy for creating effective thermal insulation while maintaining the vacuum space. Here, the effects of various pillar design parameters, such as thermal conductivity, geometry, and arrangement, on the VIG thermal performance were comprehensively investigated via the finite element method. In addition, analytical models for thermal transport were examined and thermal conductance across the VIG unit was experimentally measured for validation. The pillar design parameters, especially the height, shape, spacing, and arrangement of the pillars, showed significant effects on the thermal performance of VIG. This research also shows that the smaller contact area for horizontal pillars can effectively decrease the heat loss by more than 30%. Because current VIG analytical equations of thermal performance are only applicable to cylindrical pillars, an analytical equation that can better describe the thermal performance of rectangular parallelepiped pillars is presented, along with a discussion about the mechanism of thermal transfer for different pillar shapes. Thermo-mechanical analyses based on 3D FEM simulations can provide valuable insights into the effect of various design parameters on the overall performance the VIG, allowing for the development of an optimal VIG design.

36 MATERIALS SCIENCE↗

Vacuum insulated glazing, valve, flexible seal, and method for making vacuum insulated glazing

A vacuum insulated glazing includes first and second spaced apart glass panes having perimeter portions defining a vacuum space between the glass panes. A vacuum valve is positioned at the perimeter portions of the glass panes and includes a valve body extending between the perimeter portions of the glass panes, and having first and second ends and a fluid conduit extending from the first end to the second end of the valve body and in fluid communication with the vacuum space. A one-way valve in the fluid conduit permits fluid flow from the vacuum space, and prevents fluid flow into the vacuum space. A suction fitting is provided for connecting the valve body to a suction device. An end seal between the perimeter portions of the glass panes is provided for hermetically sealing the vacuum space. A valve for a VIG and a method of making a VIG are also disclosed.

Bhandari, Mahabir↗

Effects of edge-seal design on the mechanical and thermal performance of vacuum-insulated glazing

Although vacuum-insulated glazing (VIG) has been proposed as a promising solution towards developing energy-efficient buildings, VIGs have not become popular in the market due to several technical challenges including the complexity of the fabrication process. In particular, the edge-seal is a key component that significantly affects the thermal insulation and mechanical performance, and the development of edge-seal with adequate thermal insulation, mechanical strength, and reasonable processing cost is essential to overcome such technical issues in VIG. For this purpose, effects of edge-seal design parameters on the VIG performance should be identified. In this research, we analyzed the edge-seal for thermal transport as well as structural stresses to study the effects, and then identified and evaluated the material mixes for the edge-seal requirements. Here, the finite element simulations showed the significance of VIG corner calculation on overall thermal transmittance and the importance of seal conductivity below 1 W/m.K. The experiments with the flexible seals with different ratios of fine glass powder demonstrated that the measured shear strength values for the seal with less than 30% glass powder were more than 10 times larger than the calculated shear stress values. Based on these simulation and experimental results, a flexible sealant was developed using a proprietary mix of ceramic materials that meets the requirements of the designed VIG edge-seal, including structural as well as thermal stress resistance and a low conductivity. Moreover, the sealant is self-curing under atmospheric conditions, and thus it does not require costly inline process of laser curing or oven baking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-cell, triple pane, vacuum insulated glazing

A novel Triple Pane Vacuum Insulated Glazing (TPVIG) architecture consisting of three panes of glass separated by two offset grids is described. The grids are made of frit-coated fibers fused with the glass panes in a vacuum to create many independent hermetic cells. Unlike traditional VIGs, which are separated by support pillars, these cells significantly increase the redundancy in sealing, and the additional bonds formed by the grid lines reduce the stresses on the edge bonds thereby increasing VIG reliability. A numerical thermal analysis was conducted to determine the thermal performance of the VIG and suggested U-values below 0.5 W/m 2 -K (greater than R=11.4 hr-ft 2 -°F/Btu) can be obtained. A prototype of the VIG unit consisting of three glass panes (5.7 mm, 1.1 mm and 5.7 mm thick with low-e coating on two surfaces) was fabricated and tested for thermal performance using the hot box method. The experimental center of glass U-value for the VIG was found to be 0.42 W/m 2 K (R=13.2 hr-ft 2 -°F/Btu). Furthermore, this U-value is about four times lower than a typical Argon filled double pane window.

14 SOLAR ENERGY↗

Pulse Strengthened and Laser Edge Sealed Vacuum Insulation Glazing

A scalable, low-cost processing strategy for glass strengthening and sealing is proposed to improve the thermal performance of insulating glass units and develop innovative window technologies. In this project, a combination of large area photonic processing, additive manufacturing, and laser encapsulation techniques is reported to realize a vacuum glazing technology to meet the cost, performance, reliability, and throughput demands. A modeling framework for evaluating the mechanical and thermal response was established to verify the structural deformation and thermal conductance. Micro-size glass frits in printing ink and a continuous-wave laser curing were employed to allow the formation of a hermetic bonding layer and led to improvement of glass edge sealing. Various sealing parameters, including laser traveling speed, spot diameter, and laser power were optimized. The water seepage and mechanical strength of the resulting glass-to-glass bonding were examined as well. These results showcase the development of a practical vacuum insulating glazing with several unique features through a combination of photonic processing, laser encapsulation, and additive manufacturing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laser strengthening of additive manufactured edge seal for vacuum insulated glazing with micro-size glass frit

Sealing of glass edge is a key step in developing cost-effective and durable vacuum insulated glazing for the drive towards net-zero energy buildings. In this study, to achieve a high-strength sealing with scalable and low-cost processing, we investigated a novel sealing method based on additive manufacturing and laser process and reported quantitative analysis of the laser assisted method sealing strength and the requirement of vacuum insulation glazing. Micro-size glass frits in printing ink and a continuous-wave laser curing were employed to allow the formation of a hermetic bonding layer with low thermal budget. Controlling various sealing parameters including laser traveling speed, spot diameter, and laser power, the water seepage and mechanical strength of the resulting glass-to-glass bonding were examined. Through the response surface methodology, we identified the optimized sealing condition where the bonding strength reached 5.68 MPa. A comparation of the bonding strength between thermal sealing method and laser-assisted method has been analyzed as well.

42 ENGINEERING↗

Method and apparatus for an insulating glazing unit and compliant seal for an insulating glazing unit

A vacuum insulating glazing unit (VIGU) comprises two or more glass lites (panes) spaced apart from one another and hermetically bonded to an edge seal assembly therebetween. The resulting cavity between the lites is evacuated to create at least one insulating vacuum cavity within which are disposed a plurality of stand-off members to maintain separation between the lites. The edge seal assembly is preferably compliant in the longitudinal (i.e., edgewise) direction to allow longitudinal relative motion between the two lites (e.g., from thermal expansion). The longitudinal compliance may be obtained by imprinting a three-dimensional pattern into the edge seal material. The edge seal assembly is preferably bonded to the lites with a first bond portion that is hermetic and a second bond portion that is load-resistant. Methods for producing VIGUs and/or compliant edge seal assemblies and VIGU and edge seal apparatus are disclosed.

Francis, William H.↗

Durability Evaluation of Advanced Fenestration Technologies

In the U.S., more than 40% of primary energy and 70% of electricity is consumed in residential and commercial buildings, resulting in annual energy costs of more than $430 billion. Approximately 35% of this consumption can be attributed to losses through the building envelope, of which windows are currently the weakest link. Multiple technologies are under development to improve this performance. This includes dynamic and photovoltaic glazing as well as emerging highly insulating technologies including vacuum insulating glass (VIG), aerogels and thin-glass based multi-pane configurations. While windows are specified based on expected performance as installed, the energy savings realized by high performance windows are delivered over time. This makes it critical to understand and maximize the durability of high-performance windows to ensure those projected energy savings are delivered. Present methods for evaluating durability are based on existing technologies. These methods may not apply or be adequate for newer emerging technologies which often present novel failure mechanisms that need to be understood and evaluated differently. In this presentation, we will discuss our efforts to define appropriate methods to improve the evaluation of many existing technologies as well as evaluate the durability of emerging window technologies. This work results from the combination of an extensive review of various international standards as well as existing scientific literature. In addition, input was gathered from multiple industry stakeholders regarding present practice as well as feedback on proposed improvements to existing methods. Here we will share these findings and present proposed improvements to developing and existing durability evaluation protocols.

building envelope↗

Flat-Plate Solar-Collector Performance Evaluation with a Solar Simulator as a Basis for Collector Selection and Performance Prediction

The use of a solar simulator for performance determination permits collector testing under standard conditions of wind, ambient temperature, flow rate and sun. The performance results determined with the simulator have been found to be in good agreement with outdoor performance results. The measured thermal efficiency and evaluation of 23 collectors are reported which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, antireflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors were given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance was made possible by tests at different incident angles. The solar performance rankings were made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗

Flat-plate solar-collector performance evaluation with a solar simulator as a basis for collector selection and performance prediction

This paper reports the measured thermal efficiency and evaluation of 23 collectors which differ according to absorber material (copper, aluminum, steel), absorber coating (nonselective black paint, selective copper oxide, selective black nickel, selective black chrome), type of glazing material (glass, Tedlar, Lexan, anti-reflection glass), the use of honeycomb material and the use of vacuum to prevent thermal convection losses. The collectors are given performance rankings based on noon-hour solar conditions and all-day solar conditions. The determination with the simulator of an all-day collector performance is made possible by tests at different incident angles. The solar performance rankings are made based on whether the collector is to be used for pool heating, hot water, absorption air conditioning, heating, or for a solar Rankine machine.

Simon, F. F.↗