Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vapor Ingestion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Vapor ingestion in Centaur liquid-hydrogen tank

Vapor ingestion phenomena were investigated using scale models of the Centaur liquid hydrogen tank to determine the height of the free surface of the liquid when vapor is intially ingested into the tank outlet. Data are compared with an analysin and, is general the agreement is very good. Predictions are presented for minimum liquid levels required in the Centaur liquid hydrogen tank in order to prevent vapor ingestion when restarting the engines in space and the quantities of liquid remaining in the tank at vapor ingestion during main engine firing.

Symons, E. P.↗

Variable-gravity anti-vortex and vapor-ingestion-suppression device

A liquid propellant management device for placement in a liquid storage tank adjacent an outlet of the storage tank to substantially reduce or eliminate the formation of a dip and vortex in the liquid of the tank, as well as prevent vapor ingestion into the outlet, as the liquid drains out through the outlet. The liquid propellant management device has a first member adapted to suppress the formation of a vortex of a liquid exiting the storage tank. A plate is affixed generally perpendicular to the first member, wherein the plate is adapted to suppress vapor ingestion into the outlet by reducing a dip in a surface level of the liquid leaving the tank. A second member is affixed to the second side of the plate. The second member ensures that the plate is wet with liquid and assists in positioning bubbles away from the outlet.

Grayson, Gary D.↗

Vapor ingestion in a cylindrical tank with a concave elliptical bottom

An approximate analytical technique is presented for estimating the liquid residual in a tank of arbitrary geometry due to vapor ingestion at any drain rate and acceleration level. The bulk liquid depth at incipient pull-through is defined in terms of the Weber and Bond numbers and two functions that describe the fluid velocity field and free surface shape appropriate to the tank geometry. Numerical results are obtained for the Centaur LH2 tank using limiting approximations to these functions.

Klavins, A.↗

Validation of A Multiphase Computational Fluid Dynamics Model for Vapor Pull-Through in Normal and Low Gravity

On-orbit fluid transfer such as refueling of propellant tanks and life-support systems can enable long-duration space missions. For safe and efficient liquid transfer operations, prior knowledge of liquid positioning and liquid-vapor interface behavior while draining in a reduced-gravity environment is required. Numerical models capable of predicting vapor ingestion (or vapor pull-through) can be used to design liquid transfer operations while reducing liquid residuals, mission risk and settling thrust required to prevent vapor ingestion. An experimental program conducted in the 2.2 Second Drop Tower facility at NASA Lewis Research Center in 1969 investigated the vapor ingestion phenomenon for a range of outflow rates and tank sizes providing a database for validation. This study presents a Computational Fluid Dynamics model capable of accurately predicting the vapor ingestion using the Volume-of-Fluid multiphase solver in commercial code STAR-CCM+. A description of the experimental setup and general trends from similar studies are presented. Comparisons of the numerical prediction and test data in normal and low gravity show good agreement and give confidence in pursuing design of full-scale propellant transfer systems.

Propellant Transfer↗

Validation of a Multiphase Computational Fluid Dynamics Model for Vapor Pull-Through in Normal and Low Gravity

On-orbit fluid transfer such as refueling of propellant tanks and life-support systems can enable long-duration space missions. For safe and efficient liquid transfer operations, prior knowledge of liquid positioning and liquid-vapor interface behavior while draining in a low-gravity environment is required. Numerical models capable of predicting vapor ingestion (or vapor pull-through) can be used to design liquid transfer operations while reducing liquid residuals, mission risk and settling thrust required to prevent vapor ingestion. An experimental program conducted in the 2.2 Second Drop Tower facility at NASA Glenn Research Center investigated the vapor ingestion phenomenon for a range of outflow rates and tank sizes providing a database for validation. This study presents a Computational Fluid Dynamics model capable of accurately predicting the vapor ingestion using the Volume-of-Fluid multiphase solver in commercial code STAR-CCM+. A description of the experimental setup and general trends from similar studies are presented. Comparisons of the numerical prediction and test data in normal and low gravity show good agreement and give confidence in pursuing design of full-scale propellant transfer systems.

Computational Fluid Dynamics↗

Validation of a Multiphase Computational Fluid Dynamics Model for Vapor Pull-Through in Normal and Low Gravity

On-orbit fluid transfer such as refueling of propellant tanks and life-support systems can enable long-duration space missions. For safe and efficient liquid transfer operations, prior knowledge of liquid positioning and liquid-vapor interface behavior while draining in a reduced-gravity environment is required. Numerical models capable of predicting vapor ingestion (or vapor pull-through) can be used to design liquid transfer operations while reducing liquid residuals, mission risk and settling thrust required to prevent vapor ingestion. An experimental program conducted in the 2.2 Second Drop Tower facility at NASA Lewis Research Center in 1969 investigated the vapor ingestion phenomenon for a range of outflow rates and tank sizes providing a database for validation. This study presents a Computational Fluid Dynamics model capable of accurately predicting the vapor ingestion using the Volume-of-Fluid multiphase solver in commercial code STAR-CCM+. A description of the experimental setup and general trends from similar studies are presented. Comparisons of the numerical prediction and test data in normal and low gravity show good agreement and give confidence in pursuing design of full-scale propellant transfer systems.

Computational Fluid Dynamics↗

Contoured tank outlets for draining of cylindrical tanks in low-gravity environment

An analysis is presented for defining the outlet contour of a hemispherical-bottomed cylindrical tank that will prevent vapor ingestion when the tank is drained. The analysis was used to design two small-scale tanks that were fabricated and then tested in a low gravity environment. The draining performance of the tanks was compared with that for a tank with a conventional outlet having a constant circular cross-sectional area, under identical conditions. Even when drained at off-design conditions, the contoured tank had less liquid residuals at vapor ingestion than the conventional outlet tank. Effects of outflow rate, gravitational environment, and fluid properties on the outlet contour are discussed. Two potential applications of outlet contouring are also presented and discussed.

Symons, E. P.↗

A Computational Fluid Dynamics Study of Swirling Flow Reduction by using Anti-vortex Baffle

An anti-vortex baffle is a liquid propellant management device placed adjacent to an outlet of the propellant tank. Its purpose is to substantially reduce or eliminate the formation of free surface dip and vortex, as well as prevent vapor ingestion into the outlet, as the liquid drains out through the flight. To design an effective anti-vortex baffle, Computational Fluid Dynamic (CFD) simulations were undertaken for the NASA Ares I vehicle LOX tank subjected to the simulated flight loads with and without the anti-vortex baffle. The Six Degree-Of-Freedom (6- DOF) dynamics experienced by the Crew Launch Vehicle (CLV) during ascent were modeled by modifying the momentum equations in a CFD code to accommodate the extra body forces from the maneuvering in a non-inertial frame. The present analysis found that due to large moments, the CLV maneuvering has significant impact on the vortical flow generation inside the tank. Roll maneuvering and side loading due to pitch and yaw are shown to induce swirling flow. The vortical flow due to roll is symmetrical with respect to the tank centerline, while those induced by pitch and yaw maneuverings showed two vortices side by side. The study found that without the anti-vortex baffle, the swirling flow caused surface dip during the late stage of drainage and hence early vapor ingestion. The flow can also be non-uniform in the drainage pipe as the secondary swirling flow velocity component can be as high as 10% of the draining velocity. An analysis of the vortex dynamics shows that the swirling flow in the drainage pipe during the Upper Stage burn is mainly the result of residual vortices inside the tank due to conservation of angular momentum. The study demonstrated that the swirling flow in the drainage pipe can be effectively suppressed by employing the anti-vortex baffle.

Yang, H. Q.↗

A Computational Fluid Dynamics Study of Swirling Flow Reduction by Using Anti-Vortex Baffle

An anti-vortex baffle is a liquid propellant management device placed adjacent to an outlet of the propellant tank. Its purpose is to substantially reduce or eliminate the formation of free surface dip and vortex, as well as prevent vapor ingestion into the outlet, as the liquid drains out through the flight. To design an effective anti-vortex baffle, Computational Fluid Dynamic (CFD) simulations were undertaken for the NASA Ares I vehicle LOX tank subjected to the simulated flight loads with and without the anti-vortex baffle. The Six Degree-Of-Freedom (6-DOF) dynamics experienced by the Crew Launch Vehicle (CLV) during ascent were modeled by modifying the momentum equations in a CFD code to accommodate the extra body forces from the maneuvering in a non-inertial frame. The present analysis found that due to large moments, the CLV maneuvering has a significant impact on the vortical flow generation inside the tank. Roll maneuvering and side loading due to pitch and yaw are shown to induce swirling flow. The vortical flow due to roll is symmetrical with respect to the tank centerline, while those induced by pitch and yaw maneuverings showed two vortices side by side. The study found that without the anti-vortex baffle, the swirling flow caused surface dip during the late stage of drainage and hence early vapor ingestion. The flow can also be non-uniform in the drainage pipe as the secondary swirling flow velocity component can be as high as 10% of the draining velocity. An analysis of the vortex dynamics shows that the swirling flow in the drainage pipe during the Upper Stage burn is mainly the result of residual vortices inside the tank due to the conservation of angular momentum. The study demonstrated that the swirling flow in the drainage pipe can be effectively suppressed by employing the anti-vortex baffle.

Yang, H. Q.↗

A Computational Fluid Dynamics Study of Swirling Flow Reduction by Using Anti-Vortex Baffle

An anti-vortex baffle is a liquid propellant management device placed adjacent to an outlet of the propellant tank. Its purpose is to substantially reduce or eliminate the formation of free surface dip and vortex, as well as prevent vapor ingestion into the outlet, as the liquid drains out through the flight. To design an effective anti-vortex baffle, Computational Fluid Dynamic (CFD) simulations were undertaken for the NASA Ares I vehicle LOX tank subjected to the simulated flight loads with and without the anti-vortex baffle. The Six Degree-Of-Freedom (6-DOF) dynamics experienced by the Crew Launch Vehicle (CLV) during ascent were modeled by modifying the momentum equations in a CFD code to accommodate the extra body forces from the maneuvering in a non-inertial frame. The present analysis found that due to large moments, the CLV maneuvering has a significant impact on the vortical flow generation inside the tank. Roll maneuvering and side loading due to pitch and yaw are shown to induce swirling flow. The vortical flow due to roll is symmetrical with respect to the tank centerline, while those induced by pitch and yaw maneuverings showed two vortices side by side. The study found that without the anti-vortex baffle, the swirling flow caused surface dip during the late stage of drainage and hence early vapor ingestion. The flow can also be non-uniform in the drainage pipe as the secondary swirling flow velocity component can be as high as 10% of the draining velocity. An analysis of the vortex dynamics shows that the swirling flow in the drainage pipe during the Upper Stage burn is mainly the result of residual vortices inside the tank due to the conservation of angular momentum. The study demonstrated that the swirling flow in the drainage pipe can be effectively suppressed by employing the anti-vortex baffle.

Yang, H. Q.↗

Draining characteristics of hemispherically bottomed cylinders in a low-gravity environment

An experimental investigation was conducted to study the phenomenon of vapor ingestion during the draining of a scale model, hemispherically bottomed cylindrical tank in a low-gravity environment. Where possible, experimental results are compared with previously obtained numerical predictions. It was observed that certain combinations of Weber and Bond number resulted in draining-induced axisymmetric slosh motion. The periods of the slosh waves were correlated with the square root of the draining parameter, the ratio (Weber number)/(Bond number plus one), as was the quantity of liquid remaining in the tank when vapor was ingested into the outlet line.

Symons, E. P.↗

Effect of throttling on interface behavior and liquid residuals in weightlessness

An experimental investigation was conducted to study liquid-vapor interface behavior and subsequent vapor ingestion in a flat-bottomed cylindrical tank following a single-step throttling in outflow rate in a weightless environment. A throttling process in which the final Weber number was one-tenth of the initial Weber number tended to excite large-amplitude symmetric slosh, with the amplitude generally increasing as initial Weber number increased. As expected, liquid residuals were lower than those obtained without throttling and, for moderate values of initial Weber number, could be adequately predicted by assuming that all draining took place at the final Weber number. At large values of Weber number, residuals tended to be lower than this predicted value.

Symons, E. P.↗

Liquid hydrogen suction dip and slosh wave excitation during draining under normal and reduced gravity environments

The paper discusses the dynamical behavior of vapor ingestion, liquid residual at the incipience of suction dip, slosh wave excitation under normal and reduced gravity and different flow rates during liquid hydrogen draining. Liquid residuals at the incipience of suction dip increase as the values of gravity decrease. Also liquid residuals increase with the draining flow rates. Lower ratio of Bond number and Weber number are unable to excite slosh waves. Lower flow rates and higher gravity excites waves with lower frequencies and higher wave amplitude slosh waves.

Hung, R. J.↗