Search NASASearch

SEARCH · Search NASA

Results for “Variable Pressure Scanning Electron Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Overcoming Variability: A Reproducible Approach to SERS Detection of Nanodiamonds

Detonation nanodiamonds (DNDs) are formed at specific pressures and temperatures during explosions. Different explosives produce varied yields of DNDs within their detonation soot, with Composition B producing the highest yield. Raman spectroscopy (RS) is often used for the characterization of sp 2 - and sp 3 -hybridized carbon allotropes in carbonaceous materials because of distinct disorder and graphitic bands. Bulk diamond also gives a distinct Raman peak at 1332 cm –1 . Furthermore, as bulk diamond decreases in size to nanometer-sized species, the peak red-shifts and broadens, becoming increasingly difficult to detect with RS using visible excitations. Therefore, surface-enhanced Raman spectroscopy (SERS) was used to enhance the diamond peak of DNDs, enabling better detection and faster examination of DNDs within detonation soot. Previous literature of the SERS of DNDs delivered inconsistent results in spectral signatures and SERS substrates. Herein, refining of the methodology for the acquisition of SERS spectra of DNDs was achieved. Before any SERS experiments, the DNDs were first characterized with normal Raman (NR) and scanning electron microscopy. Two routes for SERS enhancement were evaluated: colloidal noble metal nanoparticles and evaporated silver films. Silver films produced the best signal enhancement of DNDs with the best signal-to-noise and peak enhancements observed at 20–30 nm thick silver films at 5% (∼300 μW) laser power. Consistent, reproducible SERS spectra were acquired of small aggregates of DNDs down to ∼500 nm. NR and SERS mapping analysis of DNDs before and after evaporation of silver films revealed the improvements in the detection capabilities of SERS compared with NR.

Carbon

Probabilistic Analysis of Long-Term Degradation of Microwave Cavity Flow Sensor

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. We have performed a proof-of-concept experiment of flow sensing with the transducer in liquid sodium at 340°C in impinging liquid jet geometry. The transducer remained in liquid sodium for 70 days. After removal, no structural damage was observed, and the expected transducer response was verified in a water test. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance. Since a yellowish residue was observed on the transducer surface after 70 days of immersion in liquid sodium, we have investigated possible evidence of corrosion. Chromium depletion is a typical indicator of the corrosion process in stainless steel. Scraping off a residue from the transducer and performing scanning electron microscopy (SEM) with energy dispersive analysis (EDS) did not find any chromium in the residue. Approximately 60% of the residue consisted of copper, which can be attributed to contamination of sodium due to powder residue from machining of copper and brass components of the transducer.

22 GENERAL STUDIES OF NUCLEAR REACTORS

LaFeSi–LaFe 13-x Si x composites: Modulating magnetic and magnetocaloric properties through inherent stress manipulation

We examine structural and magnetic properties of a series of La–Fe–Si alloys in the region of concentrations where they naturally form two-phase LaFeSi–LaFe 13-x Si x composites with variable content and connectivity of LaFe 13-x Si x grains distributed within the LaFeSi matrix. Theoretical calculations confirm that the LaFeSi constituent is magnetically and structurally inert below room temperature and at pressures between -10 and 10 GPa. The LaFe 13-x Si x constituent, on the other hand, is magnetically and structurally active: it exhibits first-order magnetostructural transformations that, in addition to x Si , can be controlled with temperature, magnetic field, and pressure. In composites where the concentration of the inactive constituent is ~70 wt. % or greater, the standard, single-step, LaFe 13-x Si x first-order phase transformation proceeds in two steps separated by over 30 K in a zero magnetic field. Increasing the magnetic field recouples the two steps and restores the single-step phase transformation pathway. We analyze the roles of stresses caused by both thermal expansion mismatch and the first-order magnetic phase transition in LaFe 13-x Si x to rationalize the observed physical behaviors that emerge as the temperature or/and magnetic field vary.

36 MATERIALS SCIENCE