Search NASA⌕ Search

SEARCH · Search NASA

Results for “Variable Speed”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hierarchical Speed Planner for Automated Vehicles: A Framework for Lagrangian Variable Speed Limit in Mixed-Autonomy Traffic

Here, this article presents a novel hierarchical speed planning framework for variable speed limits in mixed-autonomy traffic environments, leveraging server-side macroscopic control and vehicle-side microscopic execution. The framework integrates real-time traffic state estimation (TSE) and reinforcement learning (RL)-based control to mitigate congestion and improve traffic flow. A TSE enhancement module combines macroscopic data from sources like INRIX with high-resolution observations from connected autonomous vehicles (CAVs), enabling predictive modeling to address latency and noise. The target speed design module employs kernel smoothing and a buffer zone strategy to optimize traffic density and flow around bottlenecks. The proposed system was validated in the largest open-road test to date with 100 CAVs, demonstrating an overall 8% traffic density decrease, with a specific decrease of 7% upstream, 10% downstream, and a 52% decrease during the congestion formation phase at bottlenecks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

Autonomous Grid Support Functionality in Variable-Speed Drive-Based End-Use Loads

High penetration of inverter-based resources into power systems causes lower inertia, and it becomes more challenging to maintain grid stability during contingency events. While conventional demand response and shedding at the load side suffer from slow response, impact by unavailability, and issues from communication, variable-speed drives (VSDs) are becoming strong candidates for fast frequency response (FFR) thanks to their fast response and reduced user impact from variable power adjustment capability. In this letter, we propose an autonomous frequency support control method for a residential refrigerator with a VSD, a promising target small end-use load for FFR. We analyze the effect of the proposed controller on grid stability, and we verify the performance through laboratory experiments with a commercially available refrigerator.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving Dynamic Wireless Charging System Performance For Electric Vehicles Through Variable Speed Limit Control Integration

Electric Vehicle (EV) charging has been a significant barrier to the widespread use of EVs. Traditional EV charging methods depend on cables, and there are concerns about safety, accessibility, convenience, and weather. A recent development, dynamic (or in-motion) wireless charging, enables EVs to charge wirelessly by incorporating charging infrastructure into roadways, allowing EVs to charge while moving. However, the energy transferred relies heavily on vehicle speed and time spent in the charging lane. This paper proposes an innovative solution that combines dynamic wire-less charging with Variable Speed Limit (VSL) control. This dynamic traffic control strategy adjusts speed limits based on real-time traffic, weather, and incidents. This integration of dynamic wireless charging and VSL has two potential benefits. First, it can motivate driver compliance with VSL through the incentive of charging. Second, it can promote smoother traffic flow and improve traffic safety by implementing lower speed limits at certain times. To verify these benefits, microscopic traffic simulations in SUMO were conducted under different EV penetration rates and VSL compliance rates. Simulation results reveal that the proposed approach can enhance dynamic wireless charging system performance while improving traffic flow and safety.

Xu, Guanhao [ORNL] (ORCID:0000000214326357)↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) With Light Envelope Improvements

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER) with Light Envelope Improvements" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual refrigerant charge sensor for variable-speed heat pumps based on feature selection

The refrigerant charge level in heat pump systems significantly impacts their energy efficiency. Virtual refrigerant charge (VRC) sensing technology has been comprehensively investigated and well-established due to its lower cost compared to physical sensors. However, the previous VRC research often relied on expert judgment and physical reasoning for their variable selection, which can potentially select redundant (or highly correlated) or insignificant features, and it is also primarily focused on single-speed systems. To address these challenges, this study proposes a VRC algorithm for variable-speed heat pumps that selects features through a rigorous feature selection method in combination with physical insights. We also propose a piecewise linear model structure segmented by subcooling temperature to accurately predict charge levels, particularly when subcooling temperatures are substantially low. The proposed algorithm was evaluated using experimental data of a residential R410A heat pump, and the performance was compared with two baseline VRC algorithms. The results are: (1) The proposed algorithm outperforms for the case with subcooling temperature less than 1 °C. (2) The proposed algorithm achieves a tested mean absolute percentage error (MAPE) of 4.23%, and improves the overall accuracy for cooling conditions by approximately 60%, compared with the two baseline algorithms. (3) The proposed algorithm uses two fewer features and improves the accuracy for undercharge cooling conditions by 68.0%, compared with baseline algorithm 2. These improvements enhance prediction accuracy and prevent overfitting, providing a more reliable refrigerant charge level prediction and helping improve the heat pump energy efficiency.

Liang, Chenjiyu↗

Recharge Demand Mitigation for Latent Heat Thermal Energy Storage at Off-peak Hours

The utilization of integrated heat pump thermal energy storage (HP-TES) systems for space conditioning applications can reduce electrical power demand and achieve utility savings resulting from peak shaving and load shifting. However, issues arise when the energy required to recharge the TES exceeds the shifted energy demand, especially in extreme climates where high-temperature lifts between the outdoor air conditions and phase-change materials (PCMs) during recharging may occur. In this work, a single room-temperature (22°C) PCM-TES is integrated into a single-speed heat pump system using a secondary hydronic loop where the TES is recharged using the outdoor unit during off-peak hours. Three recharge strategies were investigated as potential pathways to reduce recharging power demand: (i) considering different heat source/sink temperatures, (ii) using a variable-speed compressor, and (iii) using a variable-speed pump. Simulations were conducted using Modelica for HP-TES recharging at different heat source/sink temperatures from -30 – 20℃ in heating mode and 0 – 30℃ in cooling mode. Results show that the most effective recharge demand reduction strategy is an HP-TES system using a single-speed compressor with a variable-speed pump for the hydronic loop run at preferable heat source/sink temperatures when the temperature lifts were reduced. Utilizing a variable-speed compressor for the HP-TES system reduced recharge time in extreme cases at the cost of additional compressor power input. The findings motivate potential control strategies that minimize recharge energy and maximize peak energy savings, hence reducing overall operating costs and annual energy consumption for HP-TES systems for space conditioning applications.

25 ENERGY STORAGE↗

Cold Climate Air-Source Heat Pump Demonstration and Analysis: Experimental Study on Cold Temperature Performance

Space heating energy is the largest end use for U.S. residential buildings, accounting for nearly 45% of residential building energy consumption nationwide, and approximately 51% of space heating energy is consumed on-site by combusting natural gas (EIA 2020a). In Colorado, approximately 53% of the statewide residential building energy consumption goes to space heating, 76% of which is provided by natural gas (EIA 2020a). Heat pumps are an efficient, electric alternative space heating technology and have been proven viable for decades. However, historically air-source heat pumps (ASHPs) have been limited to temperate climates because of (1) subpar performance at extremely cold outdoor air temperatures, (2) the need for air conditioning in summer months, and (3) the availability of natural gas in colder climates. Relatively recent advances to cold climate ASHP technology, which typically relies on inverter-driven, variable-speed compressors and variable-speed fans, have significantly improved low-temperature heat pump performance, enabling the technology to potentially save energy for many homes in cold climates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as a Type-5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type-5 WTG interfaces with the electric grid via a synchronous generator driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type-5 WTG in a power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration shows that a Type-5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to a Type-3 WTG in high-wind conditions. The developed model provides further insight into how Type-5 WTGs can benefit the smooth transition to power systems with high integration levels of inverter-based resources.

grid strength↗

Operating Wind Turbine as Synchronous Generator: Modeling and Power-Hardware-in-the-Loop Demonstration

Grid-forming (GFM) control of Type 3 and Type 4 wind turbine generators (WTGs) has attracted substantial attention in power systems research; however, the limited overcurrent capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also referred to as a Type 5 WTG, offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high integration levels of renewable generation. A Type 5 WTG interfaces with the electric grid via a synchronous generator driven by a variable speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation, and the generator shaft remains synchronous to the grid. This paper develops and tests a high-fidelity model of a Type 5 WTG in a power-hardware-in-the-loop testing environment, and it presents its operation characteristics under different grid contingencies. The power-hardware-in-the-loop demonstration shows that a Type 5 WTG inherently behaves as a GFM unit and can obtain similar performance in terms of power response, wind rotor dynamics, and stability enhancement compared to a Type 3 WTG in GFM control mode. Furthermore, the paper provides further insight into how Type 5 WTGs can support the smooth transition to power systems with high integration levels of inverter-based resources.

17 - WIND ENERGY↗

Modeling and Power-Hardware-in-the-Loop Validation of Synchronous Wind: An Inverterless Grid-Forming Wind Power Plant: Preprint

Grid-forming (GFM) control of Type-3 and Type-4 wind turbine generators has attracted substantial attention in power systems research; however, the limited over-current capability of power electronics converters continues to deteriorate the grid strength of the evolving power systems. Synchronous wind, also known as Type-5 wind turbine generator (WTG), offers a unique GFM solution to address grid integration and grid strength issues by keeping the grid largely synchronous at very high penetration levels of renewable generation. A Type-5 WTG interfaces to the electric grid via a synchronous generator (SG) driven by a variable-speed hydraulic torque converter; hence, the wind rotor operates in variable-speed mode for maximum power generation and the generator shaft remains synchronous to the grid. This paper developed and tested a high-fidelity model of Type-5 WTG under power-hardware-in-the-loop (PHIL) testing environment. The PHIL demonstration showed that a Type-5 WTGs inherently behaves as a GFM unit and can obtain similar performance in terms of power responses, wind rotor dynamics, and efficiency compared to Type-3 WTG in high wind conditions. The developed model also provides further insight on how Type-5 WTGs can benefit the smooth transition to power systems with high integration level of inverter-based resources.

grid strength↗

End-Use Savings Shapes Measure Documentation: Heat Pump Rooftop Units

The heat pump rooftop units (RTUs) measure replaces gas furnace and electric resistance RTUs with high-efficiency heat pump rooftop units (HP-RTUs). The HP-RTUs are intended to be top-of-the line, including high-efficiency fans and heat pump systems. The fans are variable speed, allowing the HP-RTUs to operate as single-zone variable air volume systems. The heat pumps are also variable speed, allowing for high part load performance. All schedules in the existing RTUs are transferred to the new HP-RTUs for consistency. Furthermore, any energy efficiency features in the existing baseline RTUs such as energy recovery or economizers are also transferred to the new HP-RTUs for consistency. This measure is applicable to approximately 45% of the ComStock floor area. The HP-RTU measure demonstrates 10.3% total site energy savings (449 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing the Energy Efficiency of Room Air Conditioners in Malaysia: Opportunities and Impact Analysis

The global room air conditioner (AC) market is rapidly transitioning toward variable-speed units, offering significant opportunities for energy-efficient designs and the adoption of low-global warming potential (GWP) refrigerants. Emerging economies, particularly in regions such as Malaysia, are expected to drive consumer demand for ACs. This report reviews key trends in the Malaysian AC market, including the availability of high-efficient ACs. Currently, variable-speed units account for 30–65% of the market, achieving cooling seasonal performance factor (CSPF) levels of between 5.0 and 6.0. Cost comparisons show that CSPF 5–6-rated, inverter-driven room ACs are competitively priced against lower-efficiency, fixed-speed units.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optically Stimulated Luminescence Data Storage (Abstract)

We will develop a tunable pulsed electron source capable of generating variable intensity highly-focused electron pulses at high repetition rates. Specifically, we need to demonstrate a high-speed variable electron gun capable of generating a variable intensity electron pulse containing between 102 and 105 electrons with an accelerating voltage of 1kV focused into a spot size <100nm in diameter at with a pulse rate >10MHz (with path to 300MHz). This combined performance cannot be achieved by commercially available electron sources. The primary technology path selected for this work will be to use a photocathode approach, where an easily modulated UV laser is used to stimulate electron emission. The approach utilizes the advances made in the development of the Dynamic TEM (DTEM), though this project will be simpler in that the pulse intensity is lower and there is no requirement for coherency. Alternate paths, including using a traditional electron beam modulated using a v-shaped slit and electrostatically deflecting the beam to adjust intensity; will also be considered for future capabilities. The electron source will then be used generate optically stimulated luminescence (OSL) in lithium fluoride (LiF) substrates to demonstrate the potential for OSL to serve as a basis technology for next generation data storage systems.

42 ENGINEERING↗

Prototyping of a Rotary Triboelectric Nanogenerator for Power at Sea

Increasing at-sea power generation by Triboelectric Nanogenerator (TENG) energy harvesters towards the order of 1-Watt will create significant opportunities to power ocean observation buoys and distributed sensor nodes by extending mission time and increasing sensor payload. Of the many possible configurations of harvesting wave energy with TENGs, we document the rationale for choosing and developing a rotary TENG that operates by the freestanding mode. The rotary TENG prototype consists of two plates, a rotor and a stator, to take advantage of the various mechanisms of converting wave action into rotational motion. We have constructed a testing apparatus that allows us to vary several key parameters of the device: distance between rotor and stator, triboelectric material, rotational speed, number of electrodes and output load impedance. Preliminary results show that when driven at a constant 500 rpm, we can achieve a power density of 0.7 W/m3. A variable speed motor drives the rotor, which can be driven using a velocity profile informed by the equivalent to the output from a wave energy converter (WEC). The optimized rotational TENG can be stacked and driven by a single shaft, increasing the energy density of the device. The output of such a TENG could be used to power devices in the ocean at a low cost and high durability.

electrostatic generator↗