Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vector Network Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Attenuator, PC-2.92mm, Fixed (Proficiency Test Report; PT ID Number 6679665)

The PSL has reviewed the documentation and data provided by NNSS–Livermore Operations with respect to this proficiency test. This proficiency test was performed to assess NNSS–Livermore Operations’ ability to perform scattering parameter calibrations. The level of documentation was satisfactory. On 12/28/2021, NNSS–Livermore Operations reported the data for the proficiency test conducted on the attenuator. NNSS–Livermore Operations performed this proficiency test using an Anritsu vector network analyzer, an electronic calibration module, and verification kit. The PSL used a Keysight vector network analyzer and mechanical calibration kit. The PSL results included in this proficiency test report were taken on June 23, 2020.

42 ENGINEERING↗

Attenuator, PC-2.92mm, Fixed (Proficiency Test Report: Document # 6679664_11752120)

The PSL has reviewed the documentation and data provided by NNSS–Livermore Operations with respect to this proficiency test. This proficiency test was performed to assess NNSS–Livermore Operations’ ability to perform scattering parameter calibrations. The level of documentation was satisfactory. On 5/19/2020, NNSS–Livermore Operations reported the data for the proficiency test conducted on the attenuator. NNSS–Livermore Operations performed this proficiency test using an Anritsu vector network analyzer, an electronic calibration module, and verification kit. The PSL used a Keysight vector network analyzer and mechanical calibration kit. The PSL results included in this proficiency test report were taken on June 23, 2020.

47 OTHER INSTRUMENTATION↗

Electrical design of the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF)—Requirements, design, and performance

The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a newly developed diagnostic for imaging time resolved diffraction in experiments at the National Ignition Facility (NIF). It builds on the successes of its predecessor, the Gated Diffraction Development Diagnostic (G3D). The FIDDLE was designed to support eight Daedalus version 2 sensors (six more hCMOS sensors than any other hCMOS-based diagnostic in NIF to date) and an integrated streak camera. We will review the electrical requirements, design, and performance of the electrical subsystems that were created to support this large number of cameras in the FIDDLE. The analysis of the data that the FIDDLE is intended to collect relies heavily on the accurate and well-understood timing of each sensor. We report camera-to-camera timing jitter of less than 100 ps rms and sensor integration times of 2.2 ns FWHM in 2-2 timing mode. Additionally, diffraction experiments on the NIF produce electric fields (EMI) on the order of 1 kV/m, which have been observed to negatively impact the performance of some electrical components of the FIDDLE. We report on the results of testing hCMOS camera electronics in a similar EMI environment generated in an offline lab. In addition, we also summarize the use of a novel approach to using a vector network analyzer as an EMI leak detector to understand and reduce the negative impacts of EMI on the FIDDLE.

47 OTHER INSTRUMENTATION↗

Capability of Impedance Measurement Using Spread Spectrum Time-Domain Reflectometry

Spread spectrum time-domain reflectometry (SSTDR) has been proposed for measuring electrical impedance on live, energized systems, in electrically noisy environments, or for measuring multiple channels simultaneously. Here we evaluate the capability of SSTDR for impedance measurement from near dc to 96 MHz and find that they agree very well with measurements from a vector network analyzer (VNA). Time gating is used to remove (calibrate out) transmission line effects. We evaluate the frequency ranges over which SSTDR at different modulation frequencies is accurate for the measurement of series resistive–capacitive ( RC ) loads and observe that fusing measurements from multiple modulation frequencies can broaden the effective measurement bandwidth.

14 SOLAR ENERGY↗

Wireless Patch Antenna Characterization for Live Health Monitoring Using Machine Learning

Temperature monitoring in extreme environments, such as coal-fired power plants, was addressed by designing and testing wireless patch antennas for use in machine learning-aided temperature estimation. The sensors were designed to monitor the temperature and health of boiler systems. Wireless interrogation of the sensor was performed using a Vector Network Analyzer (VNA) and a pair of interrogation antennas to capture resonance behavior under varying thermal and spatial conditions with sensitivities ranging from 0.052 to 0.20 $\frac{𝑀𝐻𝑧}{°C}$. Sensor calibration was conducted using a Long Short-Term Memory (LSTM) model, which leveraged temporal patterns to account for hysteresis effects. The calibration method demonstrated improved performance when combined with an LSTM model, achieving up to a 76% improvement in temperature estimation error when compared with Linear Regression (LR). The experiments highlighted an innovative solution for patch antenna-based non-contact temperature measurement, which addresses limitations with conventional methods such as RFID-based systems, infrared, and thermocouples.

20 FOSSIL-FUELED POWER PLANTS↗

Broadband Characterization and Circuit Model Development of Transmission-Scale Transformers

This report describes broadband measurements of transmission-scale transformers typical in the electric power grid. This work was performed as part of the EMP Resilient Grid LDRD project at Sandia National Laboratories to generate circuit models that can be used for high-altitude electromagnetic pulse (HEMP) coupling simulations and response predictions. The objective of the work was to obtain characterization data of substation yard equipment across a frequency range relevant to HEMP. Vector network analyzer measurements up to 100 MHz were performed on two power transformers at ABB-Hitachi and a single ITEC potential transformer. Custom cable breakouts were designed to interface with the transformer terminals and provide ground connections to the chassis at the base of the transformer bushings. The three-phase terminals of the power transformers were measured as a common mode impedance using a parallel resistive splitter, and the single-phase terminals of the potential transformer were measured directly. A vector fitting algorithm was used to empirically fit circuit models to the resulting two-port networks and input impedances of the measured objects. Simplified circuit representations of the input impedances were also generated to assess the degree of precision needed for high-altitude electromagnetic pulse response predictions, which were performed in Sandia's XYCE circuit simulator platform. HEMP coupling simulations using the transformer models showed significant reduction in the voltage peak and broadening in the pulse width seen at the power transformer compared to the traveling wave voltage. This indicated the importance of the load condition when defining the coupled insult in an electric power substation. Simplified circuit models showed a similar voltage at the transformer with a smoothed waveform. The presence of potential transformers in the simulation did not significantly change the simulated voltage at the power transformer. Single-port input impedance models were also developed to define load conditions when transfer characteristics were not necessary.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Method and system for microwave mixer phase response measurement

A system, method and apparatus for mixer phase response measurement comprises a vector network analyzer connectable to a device under test, an additional device connected to the analyzer the additional device configured to have an equal phase response to that of the device under test, a local oscillator connected to the device under test and the additional device, a series of switches connecting the device under test and the additional device to a vector voltmeter, and a reference generator connected to the vector voltmeter.

Frolov, Daniil↗

Corroborating VNA and thermal measurements of transmission loss on the DIII-D ECH waveguide system

Electron cyclotron heating (ECH) and current drive (ECCD) will play a large role in tokamak-based fusion reactors. At the DIII-D tokamak, 110 GHz microwaves injected into the plasma can provide core heating and current drive as well as impurity control, neoclassical tearing mode mitigation, and breakdown assistance. Understanding the physics of these processes relies on accurate estimates of injected ECH power. DIII-D’s ECH system consists of six MW-class Microwave Power Products (MPP) gyrotron microwave sources. Operating the gyrotrons far from the tokamak removes them from magnetic field interference, so 31.75 mm inner-diameter corrugated waveguides transmit the microwave power the 80 m from the gyrotrons to steerable launchers in the tokamak chamber. Estimates of injected power rely on knowing the generated power at the source and then subtracting transmission loss. Conventional transmission loss measurements based on calorimetric dummy loads are onerous and only possible during extended maintenance periods. This work examines two tools that provide more flexibility for the transmission loss measurements. Furthermore, a resistive temperature detector (RTD) array installed along a waveguide measures heat lost to the transmission line, and low power time domain reflectometry (TDR) measurements with a vector network analyzer (VNA) allows loss measurements without burdensome hardware modifications.

ECH↗

Assessing the vulnerability of solar inverters to EMPs: Port testing, PCI modeling, and protection strategies

Renewable energy sources are becoming an ever-larger contributor to the power grid. These renewable energy sources depend upon the power electronic devices, specifically inverters, being essential for connecting Photovoltaic (PV) generation to the grid. However, the Electromagnetic Pulses (EMPs) caused by the high-altitude nuclear explosions can generate fast broad-band pulses with nanosecond rise time, potentially causing damage or destruction to electronic components. To assess the vulnerability of PV inverters to high-altitude EMPs, the port testing and Pulsed Current Injection (PCI) modeling schemes are proposed based on the port impedance analysis. Wide-band frequency measurements are achieved by fusing impedance results from three vector network analyzers. Then, a PCI model is used to simulate the induced response to EMP, with two typical immunity levels of EC5 and EC8 tested. Here, the experiment successfully excites the induced voltage and current under EMP, where the voltage and current can reach 1500V/40A and 8000V/150Aunder EC5 andEC8, respectively. The port vulnerability analysis results demonstrate that only some ports can survive under EC5. To defend against the impact of EMP, three protection strategies are discussed.

42 ENGINEERING↗

Material Characterization Study of Magnetite Nanocrystals for RF Sensing

Magnetite nanocrystals show promise for electrically small gigahertz frequency applications, which could lead to miniaturizing transformer cores and new sensing technologies. This work presents a rigorous radiofrequency characterization of these nanocrystals using vector network analyzer (VNA) ferromagnetic resonance (FMR) measurements. For the first time, two different average diameters of Fe 3 O 4 nanocrystals are investigated (7.3 and 20.2 nm). When the VNA–FMR results were compared to micromagnetic simulations, the magnetic anisotropy (K 1 ) deviated from the ideal mean orientation value of K 1 /2 to K 1 /80 for the 7.3 nm nanocrystal. In contrast, the obtained magnetic anisotropy in 20.2 nm nanocrystals slightly deviated to K 1 /11 due to less structural deformations. These findings resulted in a newly proposed methodology for an approximate simulation based on VNA–FMR measurements. In addition, this work estimates the approximate amount of nanocrystals needed to measure a useful VNA–FMR spectrum.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifying environmentally induced calibration changes in cryogenic RF axion detector systems using deep neural networks

The axion is a compelling hypothetical particle that could account for the dark matter in our universe while simultaneously solving the strong CP problem in quantum chromodynamics. The most sensitive axion detection technique demonstrated so far makes use of a high Q cavity immersed in a strong magnetic field, where axions are converted to microwave photons. This is called an axion haloscope and has primarily targeted the 1–10 GHz range. As searches scan up in axion mass, toward the parameter space favored by theoretical predictions, individual cavity sizes decrease in order to achieve higher frequencies. This shrinking cavity volume translates directly to a loss in signal-to-noise, motivating the plan to replace individual cavity detectors with arrays of cavities. When the transition from one to (N) multiple cavities occurs, haloscope searches are anticipated to become much more complicated to operate, requiring N times as many measurements but also the new requirement that N detectors operate in unison, which can be achieved by locking them to a common frequency. To offset this anticipated increase in detector complexity, we aim to develop new tools for diagnosing experiments using neural networks. Current experiments monitor scattering parameters of their receiver for periodically measuring cavity quality factor and coupling. However, off-resonant data remain relatively useless. In this paper, we ask if it is possible that off-resonant information contained in vector network analyzer scans could be used to diagnose equipment failures/anomalies and measure physical conditions (e.g., temperatures and ambient magnetic field). We demonstrate a proof-of-concept that AI techniques can help manage the complexity of an axion haloscope search for operators.

Engel, Andrew W. [Pacific Northwest National Labor↗

Cryogenic single-port calibration for superconducting microwave resonator measurements

Superconducting circuit testing and materials loss characterization requires robust and reliable methods for the extraction of internal and coupling quality factors of microwave resonators. Additionally, a common method, imposed by limitations on the device design or experimental configuration, is the single-port reflection geometry, i.e. reflection-mode. However, impedance mismatches in cryogenic systems must be accounted for through calibration of the measurement chain while it is at low temperatures. In this paper, we demonstrate a data-based, single-port calibration using commercial microwave standards and a vector network analyzer with samples at millikelvin temperature in a dilution refrigerator, making this method useful for measurements of quantum phenomena. Finally, we cross reference our data-based, single-port calibration and reflection measurement with over-coupled 2D- and 3D-resonators against well established two-port techniques corroborating the validity of our method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

PIP-II LLRF Master Oscillator and Precision Reference Line - Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase syn- chronization throughout the accelerator. Temperature- induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the mas- ter oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods sup- port repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago]↗

Grating Polarizers at 170 GHz for ECRH Systems: Low Power Tests and Simulations

The elliptical polarization produced by a pair of sinusoidally profiled miter-bend grating polarizers has been measured experimentally and found to be in excellent agreement with theory. The polarizers were designed to be used at 170 GHz in the miter bends of a 63.5 mm corrugated metallic waveguide for creating the arbitrary elliptically polarized microwave beam needed for electron cyclotron resonance heating of plasma. Using a vector network analyzer to generate a linearly polarized HE11 incident mode, each polarizer was individually tested to measure the rotation α and ellipticity β of the elliptically polarized reflected microwave beam as a function of the grating rotation angle. The grating polarizers were then tested together to measure the elliptical polarization as a function of the angles of the combination of the two polarizers arranged sequentially on the transmission line. The map of the ellipticity versus grating angles agreed very well with numerical simulations using high-frequency structure simulator. Numerical simulations show that up to eight combinations of rotation angles of the two grating polarizers can provide the same ellipticity but with the varying ohmic loss, thus allowing the choice of settings to minimize the ohmic loss, a necessary consideration to minimize heating effects in megawatt power level systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PIP-II LLRF Master Oscillator and Precision Reference Line- Station Level Design and Testing

The PIP-II superconducting linac at Fermilab requires a highly stable RF Reference Line to maintain phase synchronization throughout the accelerator. Temperature-induced changes in the electrical length of long coaxial cables can introduce phase drift and measurement errors. The reference-line architecture mitigates these effects by phase averaging the forward and reflected RF signals, while a phase-locked loop anchors the system to the master oscillator. This work focuses on the characterization, validation, and mechanical integration of station-level RF assemblies using CAD modeling, vector network analyzer measurements, and spectrum analyzer testing. PID-controlled thermal plates will stabilize critical RF components and further reduce temperature-dependent phase and amplitude variations. These methods support repeatable, standardized designs that can be reliably integrated across the different reference-line stations.

Mosher, Alexander [U. Illinois, Chicago; Fermilab]↗

Quality and Loss Factor Characterization of YBCO Superconducting Transmission Lines for Axion Dark Matter Detection

Axion haloscope experiments aim to detect the conversion of axions into microwave photons under a strong magnetic field through resonant cavity techniques. The conversion produces an extremely small signal, requiring a cryogenic environment to reduce thermal noise, and low-loss superconducting transmission lines for minimal attenuation in the readout chain. Yttrium barium copper oxide (YBCO) cables are a promising candidate. Unlike commonly used low-loss cryogenic cables such as niobium (Nb) and niobium titanium (NbTi), which have low critical fields, YBCO is a high-temperature superconductor that can remain stable in strong magnetic fields. We characterized the quality and loss of five stripline resonators from the Brookhaven Technology Group: three YBCO, a copper reference, and a silver reference. Experimental methodology included collecting scattering parameter data on a vector network analyzer for the samples at 77 K along with room temperature baseline measurements, and employing both Lorentzian-fit and circle-fitting techniques to confirm the coupling regime and corroborate results. We achieved quality factors on the order of $10^3$ with corresponding loss factors on the order of $10^{-1}$ dB/m. Trends were comparable with literature data on Nb and NbTi at 4 K, which did have lower loss under these conditions, but suggested similar or perhaps better loss for YBCO when accounting for the temperature difference. We also developed a cryogenic probe for future measurements in a 14 T applied field at 30 mK. This will serve to directly evaluate YBCO's durability in magnetic fields, and we expect significantly improved performance at millikelvin temperatures.

Marinos, Z. [UCLA]↗

Intrinsic quality factor extraction of multi-port cavity with arbitrary coupling

In this work, we derived S-parameter based expressions for the intrinsic quality factor of an arbitrary coupled multiport microwave cavity and a non-ideal test fixture. Practical accuracy limitations of the obtained expressions specifically for superconducting accelerator cavities were evaluated both analytically and with the simulation software. The resulting formulas can be used to extract the intrinsic quality factor of normal-conducting and superconducting cavities directly from the calibrated S-parameter measurements.

43 PARTICLE ACCELERATORS↗