Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vibration-based condition monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Health Monitoring Survey of Bell 412EP Transmissions

Health and usage monitoring systems (HUMS) use vibration-based Condition Indicators (CI) to assess the health of helicopter powertrain components. A fault is detected when a CI exceeds its threshold value. The effectiveness of fault detection can be judged on the basis of assessing the condition of actual components from fleet aircraft. The Bell 412 HUMS-equipped helicopter is chosen for such an evaluation. A sample of 20 aircraft included 12 aircraft with confirmed transmission and gearbox faults (detected by CIs) and eight aircraft with no known faults. The associated CI data is classified into "healthy" and "faulted" populations based on actual condition and these populations are compared against their CI thresholds to quantify the probability of false alarm and the probability of missed detection. Receiver Operator Characteristic analysis is used to optimize thresholds. Based on the results of the analysis, shortcomings in the classification method are identified for slow-moving CI trends. Recommendations for improving classification using time-dependent receiver-operator characteristic methods are put forth. Finally, lessons learned regarding OEM-operator communication are presented.

mechanical components↗

Gear Tooth Wear Detection Algorithm

Vibration-based condition indicators continue to be developed for Health Usage Monitoring of rotorcraft gearboxes. Testing performed at NASA Glenn Research Center have shown correlations between specific condition indicators and specific types of gear wear. To speed up the detection and analysis of gear teeth, an image detection program based on the Viola-Jones algorithm was trained to automatically detect spiral bevel gear wear pitting. The detector was tested using a training set of gear wear pictures and a blind set of gear wear pictures. The detector accuracy for the training set was 75 percent while the accuracy for the blind set was 15 percent. Further improvements on the accuracy of the detector are required but preliminary results have shown its ability to automatically detect gear tooth wear. The trained detector would be used to quickly evaluate a set of gear or pinion pictures for pits, spalls, or abrasive wear. The results could then be used to correlate with vibration or oil debris data. In general, the program could be retrained to detect features of interest from pictures of a component taken over a period of time.

Delgado, Irebert R.↗

Spiral Bevel Pinion Crack Detection in a Helicopter Gearbox

The vibration resulting from a cracked spiral bevel pinion was recorded and analyzed using existing Health and Usage Monitoring System (HUMS) techniques. A tooth on the input pinion to a Bell OH-58 main rotor gearbox was notched and run for an extended period at severe over-torque condition to facilitate a tooth fracture. Thirteen vibration-based diagnostic metrics were calculated throughout the run. After 101.41 hours of run time, some of the metrics indicated damage. At that point a visual inspection did not reveal any damage. The pinion was then run for another 12 minutes until a proximity probe indicated that a tooth had fractured. This paper discusses the damage detection effectiveness of the different metrics and a comparison of effects of the different accelerometer locations.

Decker, Harry J.↗

Method Development for Experimental Characterization of Dynamic Strength of Aluminum Structures

Space Flight Hardware (SFH) experiences intense vibratory loading during flight, which only lasts a few minutes. When determining the appropriate size of these components to withstand such loading without becoming damaged (plastically deforming or breaking), standard design practice is to assume that the peak dynamic loads are applied statically. In doing so, the resulting stress is compared against a material strength parameter obtained from a quasi-static experiment. Since the near-peak stresses are only experienced over a small fraction of time in reality, this approach leads to design conservatism that unnecessarily increases structural mass as well as the associated inefficiency and financial cost. In an effort to modernize engineering design standards to appropriately consider the higher practical strength of dynamically loaded structures, this overarching research project seeks to develop an experimental test procedure for quantifying the dynamic strength of metallic alloys as a function of excitation frequency. In the ideal case, the characterization test would include an in-situ method for monitoring the onset and progression of plastic deformation of the test specimen undergoing vibratory loading. These new tests are designed to be high intensity (forcing amplitude), short term (60 seconds at full amplitude), and cyclic in nature (sinusoidal excitation via attached stinger to an otherwise cantilevered beam). In addition, the initial metallic alloy under investigation is 6061 aluminum, due to its wide use and applicability for SFH. Thus far, the most promising monitoring method under development with live-capacity is to track hysteresis behavior of the beam from power dissipation trends, calculated via force (from transducer on excitation stinger) and velocity (measurements from Laser Doppler Vibrometer) data and work to distinguish between elastic and plastic features. As a key component of this ongoing method development, any pseudo-live indication of plasticity can be corroborated against the outcome of a pre-post assessment of damage via macroscopic evaluation of beam geometry (i.e. assessing any permanent change in the beam’s tip deflection). Support for experimental design decisions as well as dynamic strength data from tests with excitation frequencies of 10, 40, and 55 Hz will be discussed. This work contributes to the foundation for a new type of vibration-based characterization experiments and generates initial data on the functional strength of 6061 aluminum under the conditions considered. Keywords: vibrations, plastic deformation, aluminum

vibrations↗

Method Development for Experimental Characterization of Dynamic Strength of Aluminum Structures

Space Flight Hardware (SFH) experiences intense vibratory loading during flight, which only lasts a few minutes. When determining the appropriate size of these components to withstand such loading without becoming damaged, standard design practice is to assume that the peak dynamic loads are applied statically. In doing so, the resulting stress is compared against a material strength parameter obtained from a quasi-static experiment. Since the near-peak stresses are only experienced over a small fraction of time in reality, this approach leads to design conservatism that unnecessarily increases structural mass as well as the associated inefficiency and financial cost. In an effort to modernize engineering design standards to appropriately consider the higher practical strength of dynamically loaded structures, this overarching research project seeks to develop an experimental test procedure for quantifying the dynamic strength of metallic alloys as a function of excitation frequency. In the ideal case, the characterization test would include an in-situ method for monitoring the onset and progression of plastic deformation of the test specimen undergoing vibratory loading. These new tests are designed to be high intensity (forcing amplitude), short term (60 seconds at full amplitude), and cyclic in nature (sinusoidal excitation via attached stinger to an otherwise cantilevered beam). In addition, the initial alloy under investigation is 6061 aluminum, due to its wide use and applicability for SFH. Thus far, the primary candidate under development with live-capacity is to track hysteresis behavior of the beam from power dissipation trends, calculated via force (from transducer on excitation stinger) and velocity (measurements from Laser Doppler Vibrometer) data and work to distinguish between elastic and plastic features. As a key component of this ongoing method development, any pseudo-live indication of plasticity could be corroborated against the outcome of a pre-post assessment of damage via macroscopic evaluation of beam geometry (i.e. assessing any permanent change in the beam’s tip deflection). Support for experimental design decisions as well as dynamic strength data from tests with excitation frequencies of 10, 40, and 55 Hz will be discussed. This work contributes to the foundation for a new type of vibration-based characterization experiments and generates initial data on the functional strength of 6061 aluminum under the conditions considered.

vibrations, plastic deformation, aluminum, testing↗

Vibration-based health characterization of multiple IMUs in UAV applications

Inertial measurement units (IMUs) are vital in UAV navigation for vehicle attitude and position estimation, especially in the frequently-occurring case of temporary loss of GPS capabilities. Degradation in these units could yield inaccurate position estimates, resulting in incorrect input for vehicle control systems. A wide variety of these units exist to meet the needs of UAV operators, general aviation, and military vehicles. In recent decades, lightweight and inexpensive MEMS sensors have grown in popularity with respect to UAVs. Studies into the failure modes of MEMS devices suggest that vibration is one of the leading causes of MEMS degradation. MEMS sensors are generally encased in their own hermetic packaging, as their small size and sensitivity cause them to be particularly vulnerable to air damping and particulate contamination when exposed. Exposure to excessive vibration can cause cracking in this packaging as well as damage to connecting electronics, with recorded results that cause sensors to act outside of their specifications, potentially providing unreliable input to controllers. A prior study from the Politecnico di Torino looked into the degradation of MEMS IMUs, specifically the AXIS-AIS402, for aerospace and vibrating environments. In the study, the authors found that after exposing MEMS IMUs to simulated vibrations from working conditions of aerospace applications, the sensors showed increased noise and increased bias instability. At NASA Ames, several widely-used MEMS IMUs were selected for a new IMU degradation study, comparing accelerometer performance before and after exposure to similar levels of vibration simulating aerospace conditions. The IMUs were selected from the Pixhawk autopilot systems, hobby sUAS, or prior experimental studies at NASA. Additionally, the industrial grade VectorNav-100 IMU was selected as a ground truth reference point to which the performance of the test sensors can be compared. In the study, each sensor is exposed to functional levels of UAV vibration as replicated on a single-frequency vibratory table in the NASA Ames SHARP Laboratory, and each accelerometer is characterized for bias, drift, and noise characteristics both before and after vibratory exposure. The focus of this study is to monitor the health of the IMU sensors and determine if sensor degradation can be detected from output error and frequency spectrum analysis, rather than from microscopic examination of the sensors. In this case, sensor degradation and faulty data can be more easily detectable by non-experts hoping to use these sensors as an important piece of an integrated package. In addition, specific sensor degradation modes potentially leading to in-flight hazards could be identified, such as accelerated levels of drift and altered temperature response. The overall goal of this work is to increase levels of safety for future users of these sensors and to provide a clear analysis of sensor limitations currently lacking in most sensor specification documentation.

IMUs↗