Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vintage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effects of hydrogen partial pressure on crack initiation and growth rate in vintage X52 steel

There is an increasing interest in ensuring compatibility of existing natural gas infrastructure with conveyance of hydrogen, especially for vintage (pre-1970s) pipeline steels. While hydrogen is known to affect the fatigue and fracture resistance of these materials, there is a lack of data on its effects on crack initiation at low hydrogen partial pressure. To address this gap, the current work presents a series of fatigue tests on vintage API Grade X52 steel in pure nitrogen, air and gaseous hydrogen at partial pressures of 1 and 207 bar. Circumferential notch tension (CNT) specimens with direct current potential difference (DCPD) measurements are used to get S–N curves for crack initiation and failure, and compact tension (CT) tests to assess crack growth rates. Results indicate that air accelerates crack initiation, low hydrogen partial pressure affects the crack growth rate, and higher pressures have the largest impact on both. Surprisingly, crack initiation is faster in air than at 1 bar hydrogen partial pressure. The CNT tests also reveal that the orientation of the banded microstructure has no effect on the crack initiation site, but it influences its growth behavior. Moreover, fractography shows that hydrogen also promotes instances of quasi-cleavage and intergranular fracture, linked to embrittlement of the material. Here, these results demonstrate that, while hydrogen may impact the entirety of the fatigue process, its effects on the early stages of damage accumulation become relevant only at larger pressures. More comprehensive studies of crack initiation in hydrogen atmospheres will be critical to future codes and standards for hydrogen infrastructure.

Circumferential notch tension↗

NSRC makes vital vintage films accessible to today's weapons researchers

A few years ago, archivists at the Lab’s National Security Research Center (NSRC) rediscovered 65 special reels of nitrate motion picture film among the 20,000 film reels in the NSRC’s collections. Because nitrate film stock was discontinued in 1951, they realized that the films contained footage from the Lab’s earliest days of nuclear testing. However, nitrate film is highly toxic and flammable. Confirming this hunch would have to wait until the NSRC team devised a strategy for safely preserving and digitizing the reels. Now, after many months of planning and collaboration with LANL fire safety and industrial hygiene teams, the reels – which include footage from Operation Sandstone, Operation Ivy, and the Trinity test – have been digitized by the NSRC archivist team and are accessible to today’s researchers.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Fracture resistance of vintage cast iron in gaseous hydrogen

In an effort to decarbonize legacy energy systems, several projects around the world are exploring alternatives to natural gas. Gaseous hydrogen is proposed as a carbon-free fuel to displace natural gas in existing legacy natural gas distribution systems, some of which continue to operate after 100 years (or more) in service. These systems, particularly in older industrial centers, contain cast iron pipe. However, the fracture resistance of most metals is degraded in gaseous hydrogen environments. This study evaluated the fracture resistance of several legacy cast iron pipe materials while exposed to gaseous hydrogen. Measurements were performed in three environments: air, a gas mixture with hydrogen partial pressure of 1 bar and pure hydrogen with a partial pressure of 34 bar. Although cast iron is generally considered a low ductility metal, elastic-plastic fracture methods are needed to assess the fracture resistance of the relatively small specimens that can be extracted from legacy pipe. Hydrogen reduced the fracture resistance of these cast iron materials by 10-40%. In air, the fracture resistance was determined to be as high as 21 MPa m 1/2 , whereas in gaseous hydrogen at pressure of about 1 bar the fracture resistance was as low as 13 MPa m 1/2 . Additional modest degradation of the fracture resistance was assessed at higher partial pressure (as low as 12 MPa m 1/2 ).

08 HYDROGEN↗

Enhancing Building Resilience: Maintaining Energy Efficiency and Thermal Comfort During Power Outages in Cold Climates

The increasing frequency and intensity of extreme weather events, such as heatwaves and cold snaps, present significant challenges to building energy performance and occupant comfort. Highly correlated with climate events are widespread long duration power interruptions that may affect thousands of buildings and millions of customers. This study evaluates the impact of building energy performance and occupant thermal comfort in medium-sized office buildings in a cold climate region. Using energy models representing pre-1980 and 2019 vintages, simulations were conducted to assess energy performance under typical weather conditions and occupant thermal comfort during power interrupted extreme cold snap and heatwave climate events under both current 2020s and future 2050s weather conditions. The results show a projected 33% increase in cooling energy demand and a 19% reduction in heating energy by 2050. Findings reveal that older buildings are more susceptible to cold discomfort during cold snaps, while modern airtight buildings are more vulnerable to overheating during heatwaves. Various passive energy efficiency measures, such as improved infiltration control, thermal windows, solar-controlled windows, and cool envelopes, were evaluated for their ability to mitigate thermal discomforts. Solar controlled windows and weatherstripping contribute to reducing cold thermal discomfort by 21% during a power-interrupted cold snap. Solar-controlled windows were found to reduce hot thermal discomfort by 34% during a future power-interrupted heatwave. The study highlights the importance of targeted retrofitting strategies to enhance thermal resilience, especially during power outages, to ensure occupant safety and comfort during extreme climate events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Core Model Proposal #373: Add Exogenous Shutdown Decider

This core model proposal adds an exogenous shutdown decider that can scale the output of a vintaged technology in years after its initial operating period. The output can be scaled above or below the technology vintage's original output. This proposal also includes code changes to disable the behavior of the s-curve shutdown decider and profit shutdown decider in calibration periods. The proposal does not include any changes to data to utilize the new exogenous shutdown decider (it only introduces the capability). It should be noted that the exogenous shutdown decider and s-curve shutdown decider serve similar functions and generally should not be used together; however, the exogenous shutdown decider and profit shutdown decider reflect different dynamics and can be used in combination.

97 MATHEMATICS AND COMPUTING↗

Building Stock Segmentation Cluster Development: Technical Reference Document

The building stock in the United States (U.S.) varies significantly as a function of several macro variables such as: climate, building type, vintage, and density. These variables change across the U.S. and can also significantly impact energy usage of the individual buildings and overall stock. For example, the square foot density and building type varies by several orders of magnitude from Manhattan to the eastern plains of Colorado. The diversity in energy use of the building stock of different areas of the U.S. is significant, and as a result, analyses that require localized results need to consider the relevant geography and the current makeup of the building stock. This document discusses the development and implementation of a stock clustering algorithm that produces a technically rigorous, consistent, and repeatable collection of geographies which are used as the basis for localized analysis. This framework considers the impact of built environment density, diversity, and climate in creating groupings of counties that create a far more nuanced analysis framework than national averages. Clustering of counties together represents a similarity of building characteristics and climate zone.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing the Impacts of Extreme Weather Events on Photovoltaic Installations Using Remote Sensing Imagery

In this study, we analyze poststorm satellite imagery to assess solar photovoltaic (PV) damage for over 11,300 systems following a catastrophic hailstorm in Austin, TX, in September 2023, which produced softball‐sized hail and for over 1500 systems across Puerto Rico and the US Virgin Islands after Hurricanes Irma and Maria in September 2017. Findings show that approximately 5.5% of identified PV sites were damaged in the hailstorm and approximately 17% of PV installations were damaged after the hurricanes. A weak correlation between hurricane wind gust speed and percent site damage was determined, with installation practices playing a heavy role in site resilience. Additionally, we show that newer module vintages are more susceptible to hail damage than older modules, possibly due to a convergence of larger size modules, decreased frame dimensions, and decreased front glass thickness but more research is needed. For hail sizes of 60 mm or greater, consistent hail damage is sustained by PV installations, regardless of system configuration.

14 SOLAR ENERGY↗

Multi-facility analysis using metered power data to quantify MRI energy use and utility bill costs across scanner operating modes

This study quantifies the energy consumption of magnetic resonance imaging (MRI) scanners across discrete operating modes during routine clinical workflows, based solely on electrical power measurements. Although previous studies have investigated MRI energy consumption within single hospitals or specific clinical settings, this research provides a broader and more systematic analysis. Researchers analyzed electrical power data and applied a previously developed semi-automatic method for identifying MRI operating modes using load duration curves for 20 MRI scanners across four different U.S. healthcare facilities, encompassing outpatient, inpatient, and mixed-use clinical settings. A key innovation is the inclusion of localized hourly utility rates to estimate costs, a parameter absent in prior literature. Key findings indicate significant variability in energy and cost profiles between weekdays and weekends. Scanner characteristics, including magnet strength, manufacturer, vintage, location, and clinical setting, influenced average daily energy consumption and power thresholds for operating modes. Notably, the clinical setting of a scanner predominantly determines its energy use. For example, the scanners in outpatient facilities consumed more energy. The breakdown of energy usage and costs by operating modes showed scanners spend between 61% and 93% of their time in nonproductive modes, with one outlier spending 34%. Average daily energy use for the scanners in the study ranged from 160 to 1069 kWh, with energy costs ranging from $\$$9 to $\$$149. This study uses an existing framework to quantify MRI energy behavior, leading to insights that can enable improved performance and cost savings across different healthcare environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

Consistency of fatigue crack growth behavior of pipeline and low-alloy pressure vessel steels in gaseous hydrogen

Here, this study investigates the fatigue crack growth rate (FCGR) behavior of pipeline and low-alloy pressure vessel steels in high-pressure gaseous hydrogen. Despite a broad range of yield strengths and microstructures ranging from ferrite/pearlite, acicular ferrite, bainite, and martensite, the FCGR in gaseous hydrogen remained consistent (falling within a factor of 2–3). Steels with higher fractions of pearlite, typical of older vintage pipeline steels, exhibited modestly lower crack growth rates in gaseous hydrogen compared to steels with lower fractions of pearlite. Crack growth rates in these materials exhibit a systematic dependence on stress ratio and partial pressure of hydrogen, as captured in the recently published fatigue design curves in ASME B31 code case 220 for pipeline steels and ASME BPVC code case 2938 for pressure-vessel steels.

08 HYDROGEN↗

Potential impact of work from home jobs on residential energy bills: A case study in phoenix, AZ, USA

Nearly one-third of U.S. households face challenges paying energy bills. During the day, many residents have routine access to cooled environments provided by others—employers, shopping centers, and other public buildings. The COVID-19 pandemic, however, has significantly shifted the cost burden of air conditioning in hot cities. Specifically, during the pandemic, many companies either laid off employees or put them in work-from-home (WFH) assignments. Large tech companies are already promoting WFH as a long-term option for their employees, even after the pandemic. This change in the nature of the workforce might reduce daily travel expenses for workers, but could also significantly increase residential energy bills, particularly during summer in very hot climates. Here, this study uses building energy simulations to quantify the potential residential energy bill penalties resulting from WFH for typical residences in Phoenix. Four building archetypes are used in this study to represent variations in building vintage, occupancy, and characteristics. The results show that, for some single-family residences in Phoenix, WFH can increase annual energy bills by more than $1100 (up to a 70% increase). The study also demonstrates that building performance enhancement retrofit measures have the potential to reduce this WFH energy bill penalty for the existing buildings substantially.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Degradation of Monocrystalline Silicon Photovoltaic Modules From a 10-Year-Old Rooftop System in Florida

A system of 180 monocrystalline aluminum back-surface field modules were installed in Cocoa, Florida, for 10 years. In total, 156 modules are characterized and compared to 3 controls. Power degradation rates vary between – 0.14% to – 3.22% per year, with median and average rates of –0.92% and –1.05% per year, respectively. The losses are primarily resistive with minor optical and recombination loss contributions. Electroluminescence imaging shows a characteristic pattern, which is shown to be resistive in nature when compared to photoluminescence. Resistive losses are due to corrosion of the rear contact Ag/solder interface and, to a much lesser degree, gridline Ag oxidation. Moisture ingress through the backsheet is likely responsible for mediating corrosion. Optical losses are due mostly to a combination of antireflection coating degradation, minor encapsulant browning, and delamination. Minor front contact corrosion may contribute to recombination. Furthermore, this study expands upon previous work on this vintage of the module by examining a large sample set, comprehensive characterization including techniques not previously used on these modules, and a comparison between two other systems of different climates.

14 SOLAR ENERGY↗

BEopt™ (Building Energy Optimization Tool) version 3.0.1 3/16/2023 [SWR-05-41]

The BEopt™ (Building Energy Optimization Tool) software provides capabilities to evaluate residential building designs and identify cost-optimal efficiency packages at various levels of whole-house energy savings along the path to zero net energy. The BEopt software can be used to analyze both new construction and existing home retrofits, as well as single-family detached and multi-family buildings, through evaluation of single building designs, parametric sweeps, and cost-based optimizations. The BEopt software provides detailed simulation-based analysis based on specific house characteristics, such as size, architecture, occupancy, vintage, location, and utility rates. Discrete envelope and equipment options, reflecting realistic construction materials and practices, are evaluated. The BEopt software uses EnergyPlus®, the Department of Energy's flagship simulation engine. Simulation assumptions are based on ANSI/RESNET/ICC Standards and the Building America Housing Simulation Protocols. The sequential search optimization technique used by the BEopt software: Finds minimum-cost building designs at different target energy-savings levels Identifies multiple near-optimal designs along the path, allowing for equivalent solutions based on builder or contractor preference. Download A BEopt™ Version 3.0.1 Beta release (Mar. 16, 2023) is now available. Download the BEopt 3.0.1 Beta setup file.

Christensen, Craig↗

Automobile and Technology Lifecycle-Based Assignment (ATLAS) v2.0.12

ATLAS is a comprehensive vehicle transaction and technology adoption microsimulator. ATLAS evolves the fleet mix of individual households by simulating the transaction (vehicle addition, disposal, and replacement) and choice (vehicle type, vintage, powertrain, and tenure) decisions in response to the co-evolving demographics, land use, and vehicle technology simulations. Different from the existing vehicle models that are either static or aggregated (e.g. stock model), ATLAS is fully disaggregated and dynamic following a sequential and circumstantial decision-making trajectory. This fine-grained approach not only enhances the realism of the simulation but also provides a nuanced understanding of the dynamics inherent in vehicle fleet evolution. ATLAS outputs are fully compatible with subsequent agent-based transportation modeling system and can enable distributional effect analysis regarding the fleet turnover among heterogeneous populations. ATLAS expands the typical new sale focused vehicle choice modeling to including used vehicle transactions that are of increasing interests to understanding the vehicle adoption behavior among lower income households.

Jin, Ling↗

STREAM: Strategic Technology Roadmapping and Energy, Environmental, and Economic Analysis Model

This is the implementation of the framework for the planning of the technological makeup of the industrial sector. Motivated by the efforts to achieve carbon neutrality, the model of this framework modifies the portfolio of technologies over time for the sector of interest such that, - Net Present Value (NPV) is minimized - Constraint on Greenhouse Emissions (GHG), e.g. carbon dioxide, is satisfied - Demand of the underlying commodity is satisfied - The current implementation reflects a case study for the electric power sector. The for a given initial set of capacities of different vintages, the space of decisions include, - Retirement of the existing capacities. - Retrofitting the existing capacities to alternative characteristics. - Creation of new capacities from a technology portfolio. All the associated quantities with the deployments, e.g. CO2, heat requirement, etc.

Thiery, David↗

Continuous surface-to-distributed acoustic sensor snapshots explain reactivation of individual natural fractures during an unconventional reservoir stimulation

ABSTRACT Fiber-optic sensing technologies allow petroleum engineering teams to detect hydraulic fracture interaction with boreholes during unconventional reservoir stimulation. In combination with high-repeatability seismic sources, the same distributed acoustic sensors (DASs) enable vertical seismic profiling (VSP) of the fracture evolution away from the boreholes. We discovered clear signatures of seismic scattering on activated fractures during nine days of continuous seismic monitoring of the fracturing stages at the Austin Chalk/Eagle Ford Field Laboratory. The present study applies a novel approach for quantitative analysis of the scattering events in terms of the evolution of the geometry and elastic stiffness of individual fractures. Our characterization strategy sequentially refines the fracture models: from a stack of 1D soft layers to 3D rectangular inclusions. First, we estimate the number of fracture locations and reflectivity using a modified sparse-spike deconvolution of the stacked VSP traces. The fracture set consists of five fractures spaced by 15–30 m with a reflectivity of approximately 1%. Then, we develop a scattering integral method to refine these estimates along with an inversion of the fracture top and bottom for each monitoring vintage. We find that, initially, some of the fractures are located above the monitoring fiber with the height of approximately 100 m. Then we integrate the seismic interpretation with the low-frequency DAS and pressure and microseismic monitoring to reconstruct the activation process of the fractures. Most likely, some of the natural fractures slowly grew downward to the monitoring fiber as a result of fluid injections in the stimulated well. This led to bright strain anomalies but did not trigger seismicity. The top of the fractures remained almost constant and were limited by a lithologic boundary/stress barrier. To our knowledge, this is the first time VSP data enabled tracking of the fracture evolution with such high spatial and temporal resolution, which was previously only available for crosswell surveys and at a much smaller scale.

Glubokovskikh, Stanislav↗