Search NASA⌕ Search

SEARCH · Search NASA

Results for “Viton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

High-pressure elasticity and equation of state of the fluoroelastomer Viton® A-500

Viton® A is a semi-crystalline copolymer of polyvinylidene fluoride and hexafluoropropylene used in various engineering applications due to its mechanical properties and chemical inertness. In situ ultrasonic spectroscopy and x-ray radiography measurements were performed in a Paris–Edinburgh press to measure the pressure dependence of the transverse and longitudinal acoustic velocity of the fluoroelastomer A-500 from 2.7 to 5.7 GPa at 296 K. In addition, we performed high-pressure Brillouin scattering measurements to obtain acoustic velocities from ambient pressure to 5.7 GPa to supplement the ultrasonic measurements, especially at low pressures. The acoustic velocities were then used to calculate a pressure–volume (P–V) equation of state, the bulk and shear moduli, and the Poisson's ratio. These quantities are compared with the reported pressure-dependent properties of related polymers over this range of pressures.

Acoustical properties↗

The Compatibility of Tefzel™ and Viton™ B with Caustic-Side Solvent Extraction Solvents

The Salt Waste Processing Facility (SWPF) plans to switch from the current Caustic-Side Solvent Extraction (CSSX) solvent to the Next Generation Solvent-Phase II (NGS-Phase II). SRNL was requested to evaluate the compatibility between polymeric materials of construction at SWPF and NGS-Phase II solvent. The work presented here concentrated on two materials of interest: Tefzel™ and Viton™ B.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fuel Properties of Oxymethylene Ethers with Terminating Groups from Methyl to Butyl

Oxymethylene ethers (OMEs) have been studied as possible additives or replacements for diesel fuels. Typically, studies have considered only methyl-terminated OMEs. Recent structure-property relationship models suggest that extended-alkyl OMEs may provide improvements to many of the properties of methyl-terminated OMEs that make them less suitable as diesel fuel blendstocks. In this work, we describe the synthesis and characterization of 16 different OMEs with methyl, ethyl, propyl, butyl, isopropyl, and isobutyl terminating alkyl groups with varying oxymethylene chain length. Indicated Cetane Number, Lower Heating Value, Flash Point, Density, Viscosity, Vapor Pressure, and Oxidative Stability are tested via ASTM standard methods. Additionally, Water Solubility, Boiling Point, seal material compatibility, and sooting propensity (via the Yield Sooting Index) are measured for these fuels. For diesel compatibility, all tested OMEs except smaller methyl and ethyl OMEs, and the branched isopropyl OME, meet cetane number requirements. Further, extending the alkyl end group increases the heating value, but all OMEs, due to their oxygen content, have heating values less than diesel; despite this, all OMEs show significant reductions in soot production per unit heating value. Only the heaviest OMEs meet diesel viscosity requirements, and most are higher density than diesel. OMEs with larger alkyl groups show the highest stability under accelerated auto-oxidation conditions. Increases in alkyl group length cause order of magnitude reduction in water solubility, from hundreds of g/L for methyl terminated OMEs to hundreds of mg/L for butyl terminated OMEs. Limited seal material testing indicates that PEEK polymers are unaffected by OMEs; while extended alkyl groups may improve compatibility with FKM (Viton), other common elastomers (NBR, silicone) remain incompatible with all tested OMEs. Overall, it is found that methyl-terminated OMEs exhibit the most potential for soot reduction, but OMEs with larger propyl and butyl terminating alkyl groups show improved compatibility with existing diesel systems.

09 BIOMASS FUELS↗

The Effect of TiDG, DCiTG (Lix ® reg;79), and Other Suppressors on the Compatibility of NGS with SWPF Polymers

This document provides a screening calculation of the potential miscibility of specific polymers proposed for use in the SWPF, notably polyether-etherketone (PEEK), ultra-high molecular weight polyethylene (UHMWPE), polyvinylidene fluoride (PVDF), Viton ® B fluoroelastomer, and Tefzel ® ethylenetetrafluoroethylene (ETFE) copolymer in different suppressors including trisisodecyl guanidine (TiDG), dicyclohexane-isotrisdecyl guanidine (DCiTG), and two other dicyclohexane guanidine related suppressors. The evaluation suggests that Tefzel ® ETFE may mildly interact with the Next Generation Solvent (NGS) regardless of the suppressor used. Based on this approach (calculations), the other listed polymers appear compatible with the NGS containing the four different suppressors. There is evidence of chemical affinity between Tefzel ® ETFE, Viton ® B with aliphatic amines (which are degradation by-products from the TiDG). In addition, the calculation suggests that drawing miscibility conclusions from exposing polymers to a single pure component may give misleading or incorrect results due to the potential for synergistic effects or other interactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SURFplus model calibration for PBX 9012

PBX 9012 is a plastic bonded explosive composed of 90.2 wt % HMX (cyclo-tetramethylene-tetranitramine) and 9.8 % Viton A (vinylidene-hexafluoropropylene copolymer). It has nearly the same composition as LX-07 (90% HMX and 10% Viton A) but with a slightly lower density. Hence it has a higher porosity and is slightly more shock sensitive. Here we describe the SURFplus model calibration for PBX 9012 using data from five shock-to-detonation transition (SDT) gas gun experiments by Burns and Chiquete, detonation front shape data from rate stick experiments and cylinder test experiment reported in Anderson et al., Jackson et al. The SDT experiments provide Pop plot data points (run distance-to-detonation) which characterize shock initiation, Lagrangian velocity time histories from embedded magnetic velocity gauges which give information on the reaction behind the lead shock, and Hugoniot data points for the reactants EOS. The rate stick experiments provide data on the curvature effect which characterize propagating detonation waves. The cylinder test experiments provide data on the detonation release isentrope used to calibrate the products EOS. The HE model uses a Davis reactants EOS with parameters that Burns and Chiquete [2020] fit to Hugoniot data, and Davis products EOS with parameters that Anderson et al. [2020] fit to cylinder test data.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Collective Summary of sCO2 Materials Development (Supercritical Transformational Electric Power Generation (STEP) Level 2 Milestone Report) (Parts I - II)

Polymers such as PTFE (polytetrafluorethylene or Teflon), EPDM (ethylene propylene diene monomer) rubber, FKM fluoroelastomer (Viton), Nylon 11, Nitrile butadiene (NBR) rubber, hydrogenated nitrile rubber (HNBR) and perfluoroelastomers (FF_202) are commonly employed in super critical CO 2 (sCO2) energy conversion systems. O-rings and gaskets made from these polymers face stringent performance conditions such as elevated temperatures, high pressures, pollutants, and corrosive humid environments. In FY 2019, we conducted experiments at high temperatures (100°C and 120°C) under isobaric conditions (20 MPa). Findings showed that elevated temperatures accelerated degradation of polymers in sCO2, and that certain polymer microstructures are more susceptible to degradation over others. In FY 2020, the focus was to understand the effect of sCO2 on polymers at low (10 MPa) and high pressures (40 MPa) under isothermal conditions (100°C). It was clear that the same selectivity was observed in these experiments wherein certain polymeric functionalities showed more propensity to failure over others. Fast diffusion, supported by higher pressures and long exposure times (1000 hours) at the test temperature, caused increased damage in sCO2 environments to even the most robust polymers. We also looked at polymers under compression in sCO2 at 100°C and 20 MPa pressure to imitate actual sealing performance required of these materials in sCO2 systems. Compression worsened the physical damage that resulted from chemical attack of the polymers under these test conditions. In FY 2021, the effect of cycling temperature (from 50°C to 150°C to 50°C) for polymers under a steady sCO2 pressure of 20 MPa was studied. The aim was to understand the influence of cycling temperatures of sCO2 for typical polymers under isobaric (20 MPa) conditions. Thermoplastic polymers (Nylon, and PTFE) and elastomers (EPDM, Viton, Buna N, Neoprene, FF202, and HNBR) were subjected to 20 MPa sCO2 pressure for 50 cycles and 100 cycles in separate experiments. Samples were extracted for ex-situ characterization at 50 cycles and upon the completion of 100 cycles. Each cycle constituted of 175 minutes of cycling from 50°C to 150°C. The polymer samples were examined for physical and chemical changes by Dynamic Mechanical and Thermal Analysis (DMTA), Fourier Transform Infrared (FTIR) spectroscopy, and compression set. Density and mass changes immediately after removal from test were measured for degree of swell comparisons. Optical microscopy techniques and micro computer tomography (micro CT) images were collected on select specimens. Evaluations conducted showed that exposures to super-critical CO2 environments resulted in combinations of physical and/or chemical changes. For each polymer, the dominance of cycling temperatures under sCO2 pressures, were evaluated. Attempts were made to qualitatively link the permanent sCO2 effects to polymer micro- structure, free volume, backbone substitutions, presence of polar groups, and degree of crystallinity differences. This study has established that soft polymeric materials are conducive to failure in sCO2 through mechanisms of failure that are dependent on polymer microstructure and chemistry. Polar pendant groups, large atom substitutions on the backbone are some of the factors that are influential structural factors.

36 MATERIALS SCIENCE↗

Proliferated Resilient Economical Half-Meter Aperture Space Telescopes (PREEMPT)

The PREEMPT LDRD was motivated by a major national need for better space-based imaging systems that are both high performing and affordable for the US Government. Current optical payloads for intelligence, surveillance and reconnaissance (ISR) and space domain awareness (SDA) missions can cost hundreds of millions of dollars and take years to develop, which makes it difficult to build the large constellations required for persistent, world-wide coverage. To address this, the team aimed to advance a different kind of large-aperture (>25 cm) telescope, called a monolithic telescope, in which key optical surfaces are built into a single piece of fused silica. This design greatly reduces payload and spacecraft complexity, the need for precision focus actuators, improves mechanical and thermal robustness, and lowers cost when compared with traditional Cassegrain telescopes that rely on many precisely aligned components. The project focused on five primary thrusts. The first thrust was to advance the concept of a V10, 25 cm, monolithic telescope forward from optical design to flight-ready stage. This was accomplished in partnership with Optimax, who delivered the first test unit in the early stages of the LDRD. The team developed several technologies necessary for this optic to be integrated into a flight demonstration. These include carbon fiber housings, highly detailed structural and thermal models and stress-reducing elastic averaging Hirth groove designs. These technologies resulted in a successful maturation of the optic, which is now slated to fly in late 2026/early 2027 for a demonstration mission. The second thrust was to advance the manufacturability of these optics. In collaboration with NIF’s optical manufacturing shop, we reduced polishing time from 480 hours to 65 hours through the implementation of optimized processes and new tools. The NIF team utilized a conceptual V8 (18 cm) optic to demonstrate this optimization, though it can be applied to the rest of the monolithic optic portfolio. Third, the team developed the first conceptual V20 (50 cm) payload, which is slated to be the next generation of LLNL optical payload systems. A set of structural, dynamic and thermal simulations were performed to identify potential challenges in the future development of this payload. Early-stage simulations suggest the payload is feasible, though thermal management will be the key focus area to maintain optimal performance. Fourth, a non-linear model of Viton was developed, to further enhance the reliability of our structural and dynamic models for future payloads. Viton acts as the primary interface material between the optic and its housing. Lastly, the team focused on successfully displaying the feasibility of using additively manufactured metal composites for optical space payloads. The team successfully demonstrated layer by layer deposition of Al-SiC composites, which have highly tunable structural and coefficient of thermal expansion (CTE) properties. These are crucial for optical payloads because CTE mismatch is one of the causes for degraded optical performance for telescopes in orbit. Overall, the work showed that monolithic telescopes could become a practical, lower-cost path to high-resolution space imaging for both national security and scientific missions.

42 ENGINEERING↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2020 Status Report)

Leak testing experiments to monitor the aging performance of Viton GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. In addition, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. No failures have yet been observed in GLT O-ring fixtures aging at 200 °F for 12 to 14 years or aging at 270 °F for 8.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 10 to 10.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicates margin remains for O-rings still in service. Aging and periodic leak testing will continue for the remaining PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O Ring Fixture LongTerm Leak Performance (FY2021 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 19 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 9.5 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 200 and 250 °F for 11.5 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 26 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Model 9975 O-Ring Fixture Long-Term Leak Performance (FY2022 Status Report)

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package has been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The fixtures are leak tested periodically and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years without failure. There has been one GLT O-ring fixture which failed after 13.4 years aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 14 years and remain in test. No failures have yet been observed in GLT O-ring fixtures aging at 270 °F for 10.4 years. All GLT-S O-ring fixtures aging at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 12.5 years. This year, one GLT-S O-ring fixture failed after 12.4 years aging at 200 °F. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing, and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in K-Area Complex (KAC). Oxygen consumption testing, which includes results from temperatures near KAC normal storage temperatures, is ongoing to provide further confidence and corroborate these extrapolations. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 25 mock-up PCV fixtures.

36 MATERIALS SCIENCE↗

Model 9975 O Ring Fixture Long-Term Leak Performance (FY2024 Status Report)

Leak testing experiments to monitor the aging performance of Viton ® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aging at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aging at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months of testing while fixture #18 remained leak tight. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F.

42 ENGINEERING↗

FY2025 Status Report: Model 9975 O Ring Fixture Long-Term Leak Performance

Leak testing experiments to monitor the aging performance of Viton® GLT and GLT-S O-rings used in the model 9975 shipping package have been ongoing since 2004 at Savannah River National Laboratory. Seventy tests using mock-up 9975 primary containment vessels (PCVs) with GLT O-rings were assembled and heated to temperatures ranging from 200 to 450 °F. Due to material substitution, fourteen tests with GLT-S O-rings were initiated in 2008 and heated to temperatures ranging from 200 to 400 °F. The conditioning temperatures are elevated compared to the calculated maximum O-ring temperature in a 9975 package in storage, 158 °F, to accelerate aging and enable observations of O-ring failures in a reasonable time frame. The mock-up PCV fixtures are leak tested periodically, and all GLT O-ring fixtures aged at 350 °F or above have failed to maintain a leak-tight seal. Eight GLT O-ring fixtures aged at 300 °F have failed after 2.8 to 5.7 years at temperature while the remaining fixtures at 300 °F were retired from testing following more than five years of aging without failure. Two of these retired fixtures were returned to testing and heated to 350 °F to evaluate the impact of additional heating at higher temperature for aged O-rings. Fixture #20 failed after 3 months while fixture #18 failed after 9 months at 350 °F. These O-rings demonstrated that aged and in-service O-rings can continue to be used, even at higher temperatures, after being in storage, and their leak performance are consistent with other samples at 350 °F. There has been one GLT O-ring fixture which failed after 13.4 years of aging at 200 °F. However, 20 other GLT O-rings aging at 200 °F have remained leak-tight for over 16.9 years and remain in test. There are two GLT O-ring fixtures at 270 °F; one fixture has failed after 12.9 years while the other fixture remains in test after 12.5 years. All GLT-S O-ring fixtures aged at 300 °F or above have failed their leak test. No failures have yet been observed in GLT-S O-ring fixtures aging at 250 °F for 14.9 years, while one GLT-S O-ring fixture failed after 12.4 years at 200 °F. The leak testing data to date suggest the GLT and GLT-S O-rings aging in the K-Area Complex (KAC) storage at temperatures of 158 °F might maintain a leak-tight seal for up to 59 years. Data from the O-ring fixtures are generally consistent with results from compression stress-relaxation testing and provide confidence in the predictive models based on those results. However, uncertainty exists in extrapolating these elevated temperature results to the lower temperatures of interest for normal storage in KAC. The collective data from these test efforts suggest the minimum O-ring service life at KAC normal storage conditions should be at least 34 years for GLT and GLT-S O-rings. Measurement of compression set in O-rings removed from failed fixtures, compared to that from KAC surveillance O-rings, indicate significant margin remains for O-rings still in service in 9975 packages in KAC. Aging and periodic leak testing will continue for the remaining 24 mock-up PCV fixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Shock initiation of the HMX-based explosive PBX 9012: Experiments, uncertainty analysis, and unreacted equation-of-state

In this study, shock initiation experiments have been carried out on the polymer-bonded explosive PBX 9012 [nominally 90% octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine (HMX), 10% vinylidene–hexafluoropropylene copolymer (Viton A) by weight] in order to provide calibration data for the explosive’s unreacted equation-of-state (EOS) and shock-to-detonation transition for reactive burn rate calibration. The input pressures covered the range of 1.86–4.43 GPa. This provided run-to-detonation depths ranging from > 22.3 mm for the lowest pressure shot to 4.91 mm at the highest pressure. The relative shock sensitivity of PBX 9012 is compared to other HMX-explosives in terms of the Pop-plot, showing that the studied explosive is more sensitive than other similar HMX-based counterparts (with notable exceptions). The uncertainty in the shock velocity determinations from the shock tracker measurements are also investigated, yielding new uncertainty measures in the generated Hugoniot data and run-to-detonation coordinates. Finally, the unreacted equation-of-state is determined using a linear U s – u p Mie–Grüneisen relation and the Davis reactants EOS analytical form, the latter being more suited for reactive burn modeling.

36 MATERIALS SCIENCE↗

NSTX-U Machine Core Vacuum Seals Upgrade Design

The vacuum in the National Spherical Torus Experiment Upgrade (NSTX-U) is in the range of 2.66x10⁻⁶ Pa (2x 10⁻⁸ torr). To enhance vacuum seals and lower gas permeation in the NSTX-U and therefore ensuring operation safety and quality, the machine core vacuum seal design has been upgraded using double elastomeric seals and pumped interspaces (guard channels). In NSTX-U machine core, there are six major vacuum seals, including upper and lower vacuum vessel main flanges, upper and lower bellows flanges, and two in the ceramic isolation ring assembly that are mounted to the upper vacuum vessel main flange. The elastomeric seals are commercially available and customized fluorocarbon (Viton) O-rings. To ensure appropriate O-ring compression ratios for the vacuum seal, the O-ring grooves are customized with appropriate tolerances considering specific situations for each seal. In this upgrade, the vacuum in each interspace is designed to reach 13.33 Pa (0.1 torr), thus the overall pressure difference crossing each double O-ring seal is expected to be reduced by at least three orders of magnitude, and accordingly the overall rates of leakage and permeation will be lowered by three orders of magnitude. The corresponding pump-down times for each seal, at room temperature, are estimated at about 60 s. Additionally, the vacuum pumped interspaces will be able to function as a real-time leak monitor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Evaluation of the SAVY-4000 1 Quart Container at High Heat Loads

The SAVY-4000 Safety Analysis Report (SAR) was published in 2013 which established the design life of the container series through physical testing that meets applicable requirements from DOE M 441.1-1, Nuclear Material Packaging Manual. One critical requirement in DOE M 441.1-1 is to set a maximum heat load for the entire series to ensure that throughout the lifetime of the container, each of the components still performs within manufacture specifications. The original maximum decay heat limit has been defined within the SAVY-4000 SAR, which was accomplished by completing a series of tests that heat loaded the SAVY-4000 series and measured the steady state temperature and graded it against manufacture specifications. The container series is comprised of a corrosion resistant 316L stainless steel containment boundary, ceramic composite filter for the prevention of radiological particulate release and a chemically stable O-ring made of Viton ® . Currently, the SAVY 4000 maximum decay heat load is set at 25 Watts and the heat load expected during normal handling and storage is considered sufficient that the SAVY 4000 container requirements will not be the limiting factor for storage of most common material in use at TA-55, e.g. weapons grade oxide, americium, Pu-238 oxide and encapsulated heat sources. The SAVY 4000 lifetime was originally set as 5 years within the SAVY-4000 SAR, but in July 2019 the lifetime was extended to 15 years through a technical basis justification approved by the Department of Energy (DOE) Los Alamos Field Office. The 25 Watt limit applies to all SAVY 4000 container sizes; 1-quart, 2-quart, 3-quart, 5-quart, 8-quart, 12-quart, 5-gallon, and 10-gallon.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gel Permeation Chromatography Methods for Stockpile Relevant PBXs

In order to accurately characterize chemical changes to the binder in plastic-bonded explosives (PBXs) it is important to develop new gel permeation chromatography (GPC) methodologies as well as update previous methods. Herein we present new and updated GPC methodology for Viton A, Kraton G, and Oxy 461. The methods developed were specifically designed for Malvern OMNISEC with a Mixed C column, but minor modifications could be made to these methods to make applicable to other instrumentation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Destructive Examination of Shipping Package 9975-02731

Destructive and non-destructive examinations were performed on the components of the package 9975-02731 as part of a comprehensive Savannah River Site surveillance program for plutonium materials stored in the K-Area Complex (KAC). The package stored nuclear materials in KAC for 13.8 years. Inspection of the package during opening in KAC noted one non-conforming condition: a large discolored area on the upper fiberboard subassembly. The package was subsequently transferred to Savannah River National Laboratory for more detailed examination. In addition to the observation noted in KAC, the following conditions were observed: (1) Axial gap of 1.021 inch slightly exceeded the 1 inch maximum criterion, and (2) Lead shield height exceeded drawing tolerance of 24.7 inch by 0.019 inch. Visual examination of the upper fiberboard assembly and analysis of the discolored fiberboard indicate the discoloration was due to wood glue residue. The physical, thermal, and mechanical properties of the fiberboard met the acceptance criteria and/or were within the range of previously tested fiberboard and baseline samples. The visual, microscopic and tensile testing results were consistent with previous O-ring and baseline Viton results. The lead shield surface was covered with corrosion product as observed on other shields but there was no evidence of excessive blistering, flaking, or spalling. Besides minor and expected corrosion, no evidence of a degraded condition was found in this package. Examination of the 9975-02731 corroborates existing evidence that the 9975 package is robust and the components can perform their expected functions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗