A multiscale approach to analyze the effect of radial void fraction distributions on BWR neutronic lattice parameters

The goal of this study is to analyze the effect of radial void fraction distribution, considered at three degrees of fidelity, on lattice and 2-group homogenized cross sections. The novelty of this work lies in its use of experimentally-determined radial void fraction distributions which allows for fine-scale coolant density data with no predictive uncertainty and which could be prohibitively expensive to simulate over the range of operational parameters used in the experiments. The experimentally-determined radial void fraction distributions are also characterized using a statistical tool called a semi-variogram in order to determine the scale of continuity. Void fraction distributions are averaged at the lattice and subchannel level for comparison with the fine-scale model. Models averaged at the subchannel and lattice level show a difference in about 68% of the time. Also, by comparing 2-group homogenized cross-sections, the differences between the subchannel and homogeneous cases are measurable.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gaussian integral method for void fraction

Here, a novel method, the Gaussian Integral Method (GIM), is presented for calculating void fractions in Computational Fluid Dynamics–Discrete Element Method (CFD-DEM) simulations. GIM is versatile and applicable to various grid types, including structured and unstructured polyhedral meshes, without requiring special boundary treatments. An optimization technique is introduced to make GIM independent of grid resolution and type. The method is validated against experimental data from a fluidized bed, demonstrating that GIM produces realistic simulations closely resembling experimental observations. Additionally, unstructured polyhedral grids using GIM outperform structured grids of equivalent resolution, yielding results more aligned with experimental data. The gradient of the void fraction is computed in the CFD solver and utilized in the DEM solver for precise estimation at particle locations. Overall, GIM provides an effective solution for void fraction calculations in particulate media simulations with complex geometries, enhancing the accuracy and applicability of CFD-DEM simulations for industrial processes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

X-ray Imaging-Based Void Fraction Measurement in Saturated Flow Boiling Experiments with Seawater Coolant

Recent studies have shown that the presence of dissolved salts in water can exhibit peculiar flow boiling and two-phase flow regimes. Two-phase flow and convective flow boiling are typically characterized with the help of void fraction measurements. To quantitatively improve our understanding of two-phase flow and boiling phenomenon with seawater coolant, void fraction data are needed, which can not be obtained from optical imaging. In this paper, we present experimental void fraction measurements of saturated flow boiling of tap water and seawater using X-ray radiography. X-rays with a maximum energy level of 40 KeV were used for imaging the exit region of the heated test section. At lower heat flux levels, the two phase flow in seawater was bubbly and homogeneous in nature, resulting in higher void fractions as compared to tap water. With an increase in heat flux, the flow regime was similar to slug flow, and void fraction measurements approached similarity with tap water. The predicted pressure drop using the measured void faction shows good agreement with the measured total pressure drop across the test section, demonstrating the validity of the measurement process.

Eckels, Seth↗

Flow pattern and void fraction characterization in nitrogen/water flows through a diamond-type triply periodic minimal surface lattice

Here, this study presents, to the authors knowledge, the first experimental investigation on the void fraction and flow patterns in two-phase flows through a diamond-type Triply Periodic Minimal Surface (TPMS) lattice. An additively manufactured TPMS structure was tested under upward co-current flow of a water/nitrogen mixture. Superficial velocities varied for a total of 42 test conditions (gas: 0.01–2.4 m/s; liquid: 0.01–2.4 m/s; mass flux: 20–2370 kg/m 2 ·s). High-speed video and X-ray imaging enabled time-averaged void fraction measurements and identified six distinct flow regimes which were used to develop a flow pattern map. Comparison of the void fraction data with correlations from literature demonstrated the Rouhani and Axelsson (1970) [49] correlation modified by Steiner (1993) [52] provided the best agreement, which was improved with empirically fit coefficients. This approach predicted the void fraction with errors < ±20% for 64% of the data, with a mean absolute percent deviation (MAPD) of 23%. The measured frictional pressure drop was compared to correlations from literature which captured the observed trends but did not provide good accuracy. The best agreement was found after optimizing the empirical coefficients of the Muller-Steinhagen & Heck (1986) [56] correlation; this approach captured 33% of the data within ±20% with a MAPD of 46% over the full range and captured 71% of the data within ±20% a MAPD of 13.3% at mass fluxes >1100 kg/m 2 -s. These results provide foundational insight into TPMS two-phase flow behavior and inform modeling and design of advanced heat exchange components incorporating TPMS geometries.

42 - ENGINEERING↗

Gas-liquid Phase Distribution and Void Fraction Measurements Using the MRI

We used a permanent-magnet MRI system to estimate the integral and spatially- and/or temporally-resolved void-fraction distributions and flow patterns in gas-liquid two-phase flows. Air was introduced at the bottom of the stagnant liquid column using an accurate and programmable syringe pump. Air flow rates were varied between 1 and 200 ml/min. The cylindrical non-conducting test tube in which two-phase flow was measured was placed in a 2.67 kGauss MRI with MRT spectrometer/imager. Roughly linear relationship has been obtained for the integral void-fraction, obtained by volume-averaging of the spatially-resolved signals, and the air flow rate in upward direction. The time-averaged spatially-resolved void fraction has also been obtained for the quasi-steady flow of air in a stagnant liquid column. No great accuracy is claimed as this was an exploratory proof-of-concept type of experiment. Preliminary results show that MRI a non-invasive and non-intrusive experimental technique can indeed provide a wealth of different qualitative and quantitative data and is especially well suited for averaged transport processes in adiabatic and diabatic multi-phase and/or multi-component flows.

Daidzic, N. E.↗

High-throughput measurements of CO 2 permeance and solubility in ionic liquid reveal a synergistic role of ionic interactions and void fractions

The factors that govern CO 2 solubility in ionic liquids (ILs) are of great interest for the development of new materials for CO 2 capture and utilization. The cationic functional group (i.e., imidazolium, pyrrolidinium, pyridinium, etc.), alkyl chain length of cation, degree of fluorination of anion, anion size, and the void fraction in IL are known to influence CO 2 solubility. However, a comprehensive explanation of how these factors collectively affect CO 2 solubility has not been developed yet. This knowledge gap is largely attributed to the lack of CO 2 solubility data for IL structures other than imidazolium based ILs. We report here an automated high-throughput (HT) setup for the measurement of CO 2 solubility in room-temperature ILs (RTILs) combining six different anions and nine different cations for a total of 19 different specific ranges of RTILs. The HT setup first dispenses up to 200 µL of RTILs in a 96-well microtiter plate and then utilizes a robotic arm to measure cyclic voltammogram (CV) in each well using maneuverable Ag electrodes. The Cottrell analysis of the CO 2 reduction CV peak provides a direct measurement of CO 2 permeance in RTILs, which yields Henry’s constant from the estimated diffusion coefficient of CO 2 . Henry’s constants thus obtained are in very good agreement with those reported earlier. The measured CO 2 permeance and Henry’s constant of all RTILs seem to follow a first-order dependence on void fraction and a second-order dependence on electrostatic interaction between anion and cation of IL, with some synergistic dependence on the product of a void fraction and electrostatic interaction, making them two important descriptors for the design of novel ILs.

CO2 Solubility↗