Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatile collection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multisorbent tubes for collecting volatile organic compounds in spacecraft air

The sampling capability of Tenax-TA tubes, used in the National Aeronautics and Space Administration's solid sorbent air sampler to trap and concentrate contaminants from air aboard spacecraft, was improved by incorporating two sorbents within the tubes. Existing tubes containing only Tenax-TA allowed highly volatile compounds to "break through" during collection of a 1.5 L air sample. First the carbon molecular sieve-type sorbents Carboxen 569 and Carbosieve S-III were tested for their ability to quantitatively trap the highly volatile compounds. Breakthrough volumes were determined with the direct method, whereby low ppm levels of methanol or Freon 12 in nitrogen were flowed through the sorbent tubes at 30 mL/min, and breakthrough was detected by gas chromatography. Breakthrough volumes for methanol were about 9 L/g on Carboxen 569 and 11 L/g on Carbosieve S-III; breakthrough volumes for Freon 12 were about 7 L/g on Carboxen 569 and > 26 L/g on Carbosieve S-III. Next, dual-bed tubes containing either Tenax-TA/Carbosieve S-III, Tenax-TA/Carboxen 569, or Carbotrap/Carboxen 569 to a 10-component gas mixture were exposed, in dry and in humidified air (50% relative humidity), and percentage recoveries of each compound were determined. The Tenax-TA/Carboxen 569 combination gave the best overall recoveries (75-114% for the 10 compounds). Acetaldehyde had the lowest recovery (75%) of the 10 compounds, but this value was still an improvement over either the other two sorbent combinations or the original single-sorbent tubes.

NASA Center JSC↗

Miniature Low-Mass Drill Actuated by Flextensional Piezo Stack

Recent experiments with a flextensional piezoelectric actuator have led to the development of a sampler with a bit that is designed to produce and capture a full set of sample forms including volatiles, powdered cuttings, and core fragments. The flextensional piezoelectric actuator is a part of a series of devices used to amplify the generated strain from piezoelectric actuators. Other examples include stacks, bimorphs, benders, and cantilevers. These devices combine geometric and resonance amplifications to produce large stroke at high power density. The operation of this sampler/drill was demonstrated using a 3x2x1-cm actuator weighing 12 g using power of about 10-W and a preload of about 10 N. A limestone block was drilled to a depth of about 1 cm in five minutes to produce powdered cuttings. It is generally hard to collect volatiles from random surface profiles found in rocks and sediment, powdered cuttings, and core fragments. Toward the end of collecting volatiles, the actuator and the bit are covered with bellows-shaped shrouds to prevent fines and other debris from reaching the analyzer. A tube with a miniature bellows (to provide flexibility) is connected to the bit and directs the flow of the volatiles to the analyzer. Another modality was conceived where the hose is connected to the bellows wall directly to allow the capture of volatiles generated both inside and outside the bit. A wide variety of commercial bellows used in the vacuum and microwave industries can be used to design the volatiles capture mechanism. The piezoelectric drilling mechanism can potentially be operated in a broad temperature range from about-200 to less than 450 C. The actuators used here are similar to the actuators that are currently baselined to fly as part of the inlet funnel shaking mechanism design of MSL (Mars Science Laboratory). The space qualification of these parts gives this drill a higher potential for inclusion in a future mission, especially when considering its characteristics of low mass, small size, low power, and low axial loads for sampling.

Sherrit, Stewart↗

Radio Heating of Lunar Soil to Release Gases

A report proposes the development of a system to collect volatile elements and compounds from Lunar soil for use in supporting habitation and processing into rocket fuel. Prior exploratory missions revealed that H2, He, and N2 are present in Lunar soil and there are some indications that water ice may also be present. The proposed system would include a shroud that would be placed on the Lunar surface. Inside the shroud would be a radio antenna aimed downward. The antenna would be excited at a suitably high power and at a frequency chosen to optimize the depth of penetration of radio waves into the soil. The radio waves would heat the soil, thereby releasing volatiles bound to soil particles. The escaping volatiles would be retained by the shroud and collected by condensation in a radiatively cooled vessel connected to the shroud. It has been estimated that through radio-frequency heating at a power of 10 kW for one day, it should be possible to increase the temperature of a soil volume of about 1 cubic m by about 200 C -- an amount that should suffice for harvesting a significant quantity of volatile material.

Chui, Talso↗

Transient Molecular Transfer During Vacuum Testing

A common question in contamination budgeting involves the loss of collected volatiles during ambient I&T activity under vacuum and the resultant cross-contamination from outgassing. (1) How much of the material collected under ambient conditions evaporates under vacuum? (2) Why do pristine surfaces sometimes show increased molecular contamination after vacuum bakeout? (3) How much of the collected molecular contamination is transient (i.e. migratory) and how much is permanent? Measuring the transient deposition may be accomplished using a thermally passive QCM

Perry, Radford L.↗

Microwave Extraction of Volatiles for Mars Science and ISRU

The greatest advantage of microwave heating for volatiles extraction is that excavation can be greatly reduced. Surface support operations would be simple consisting of rovers with drilling capability for insertion of microwaves down bore holes to heat at desired depths. The rovers would also provide support to scientific instruments for volatiles analysis and for volatiles collection and storage. The process has the potential for a much lower mass and a less complex system than other in-situ processes. Microwave energy penetrates the surface heating within with subsequent sublimation of water or decomposition of volatile containing minerals. On Mars the volatiles should migrate to the surface to be captured with a cold trap. The water extraction and transport process coupled with atmospheric CO2 collection could readily lead to a propellant production process, H2O + CO2 yields CH4 + O2.

Ethridge, Edwin C.↗

Materials testing for spacecraft use

A technique has been developed for determining the outgassing characteristics of materials intended for spacecraft use. A measurement of the total mass loss (TML) and of the collected volatile condensable materials (CVCM) is used as a guide for selecting those materials low in outgassing. The data were used to compare the outgassing from two conductive black paints. In addition, the apparatus was also used in an attempt to simulate expected launch temperatures by collecting the outgassed molecules on a glass plate, which simulates a nearby thermal control surface. The glass plate was then irradiated in vacuum by simulated sunlight. Transmittance patterns of the clean glass plate and also with the condensed material on it were compared with the transmittance pattern after irradiation of the condensate. The transmittance patterns showed a drastic change. The resultant discoloration indicated the detrimental effects of the contamination and aided in selecting the better conductive paint. Additional tests utilizing an aluminized mirror collector plate have been run to show the effect of irradiation upon the CVCM from certain different classes of materials often used on spacecraft.

Park, J. J.↗

'Mysterite' - A late condensate from the solar nebula

An attempt is made to clarify the nature of 'mysterite', a material that had been postulated to explain the overabundance of Tl, Bi, and Ag in certain chondrites. Four dark clasts and a vein sample from the H6 chondrite Supuhee were analyzed by radiochemical neutron activation analysis for Ag, Au, Bi, Br, Cd, Cs, Ge, In, Ir, Ni, Os, Rb, Re, Sb, Se, Te, Tl, and Zn. One of the clasts is enriched in all volatile elements, while the other four samples are enriched only in the siderophile volatiles Ag, Bi, and Tl. The enrichments range up to 100 times typical H6 chondrite abundances. The proportions of Ag, Bi, and Tl suggest the presence of at least two, Tl-rich and Tl-poor, varieties of mysterite. The former seems to dominate in Supuhee and Krymka, and the latter in Mezo-Madaras. Apparently mysterite is a late condensate from the solar nebula that collected volatiles left behind by earlier generations of chondrites. It was incorporated in Supuhee and perhaps in other chondrites (mainly of low petrologic types) during brecciation events.

Higuchi, H.↗

Techniques used for limiting degradation products of polymeric materials for use in the space environment

Techniques are discussed for limiting or controlling the degradation products (outgassing) of polymeric materials in the space environment. One technique, now ASTM E-595-77, is used to screen out those materials which lose greater than 1% Total Mass Loss when in vacuum for 24 hours at 125 C and which have more than 0.10% Collected Volatile Condensable Materials condensing on a collector surface at 25 C. Examples of silicone materials which are high and low in outgassing are given. The numerous mechanical motions in spacecraft experiments require liquid lubricants which also might degrade in space. Labyrinth seals and barrier films are utilized to limit the degradation of or from these lubricants. A recoverable in-flight experiment has been proposed for making definitive measurements of how effective these techniques are in limiting the amounts and escape paths of outgassed molecules.

Vest, C. E.↗

Contamination effects from materials selected for spacecraft instruments

Measurements of the Total Mass Loss (TML) and the Collected Volatile Condensable Materials (CVCM) are used as a guide for selecting those materials being low in outgassing. A contamination modelling method utilizing the data and also the rate at which a material outgasses in a system with a known conductance has been developed and has been applied to the problem encountered with the Very High Resolution Radiometer (VHRR). Recently, the contamination model has been applied to the problem with the 5th band of the Multi-Spectral Scanner on the Landsat-C satellite. In the MSS design, the volumes involved and their respective conductance in a molecular flow field demonstrated that the water vapor adsorbed and absorbed by an epoxy paint was being pumped off and re-ad(b)sorbed, with a resultant very slow loss of water during each degassing temperature cycle of the instrument's cooler. Recommendations for designing improved coolers are presented.

Heslin, T. M.↗

Effects of hydraulic fluid CVCM on silver-Teflon

Changes in the solar absorptance of silver-Teflon (Ag/FEP) surfaces were measured after contamination by the outgassing products of hydraulic fluid and irradiation by solar simulators. Although radiator surfaces are selected for stability to the solar ultraviolet and particulate environment, contaminant deposition and their interaction with solar exposure can degrade their performance. The test procedure to deposit the hydraulic fluid collected volatile condensible material (CVCM), irradiate, and determine solar absorptance changes by reflectance measurements using a spectrophotometer and a solar simulator is described. The tests showed that for the estimated deposition rates on the Ag/FEP, the hydraulic fluid CVCM fraction remaining under normal conditions (above -40 C) would not degrade its performance. The residual CVCM can be easily removed from Ag/FEP by wiping with a solvent saturated flannel. The changes in solar absorptance with the CVCM film thickness and the radiation exposure duration are reported, concluding that vacuum ultraviolet radiation did not prevent easy removal of CVCM.

Muscari, J. A.↗

Outgassing data for spacecraft materials

A system for determining the mass loss in vacuum and for collecting the outgassed compounds was developed. Outgassing data, derived from tests at 398 K (125 degrees C) for 24 hours in vacuum as per ASTM E 59577, are compiled for numerous materials for spacecraft use. The data presented are the total mass loss (TML) and the collected volatile condensable materials (CVCM). The various materials are compiled by likely usage and alphabetically.

Campbell, W. A., Jr.↗

Nonmetallic materials contamination studies

In order to impose adequate contamination control requirements in the selection of Wide Field Planetary Camera (WFPC) materials and to develop a data base of potential optical degradation of the WFPC charge-couple device window, the outgassing properties of WFPC materials and the collected volatile condensed material (CVCM) effects on MgF2 transmittance were measured. Changes in the transmittance were monitored in the wavelength region from 115 nm to 300 nm for selected CVCM thicknesses up to 150 nm. The outgassing properties of reemitted CVCM were also studied.

Muscari, J. A.↗

Absorption spectra of typical space materials in the vacuum ultraviolet

In order to develop a data base for potential optical degradation of space vacuum ultraviolet instruments, the collected volatile condensed material (CVCM) transmittance was measured in the wavelength region from 115 nm to 300 nm. The parent outgassing materials included: the adhesives, Ablebond 36-2, Trabond BB-2116, EA-9309, and Scotchweld 2216; the paints, Chemglaze Z-306, Z-306 over 9922 primer, Z-306 over AP-131 primer, Cat-A-Lac 463-3-8, 463-3-8 over primer, 3M Nextel 401-C10, and 401-C10 over 901-P1 primer; the resins, Fiberite 934, Solithane 113/C113-300 Formulation no. 1, and 113/C113-300 Formulation no. 8; the lubricants, Lube-Lok 4306 and RT/Duroid 5813; and the double-sided adhesive tape 3M-415. The effect of thermal vacuum conditioning of selected materials was also studied. The transmittance measurements were used to calculate the absorption coefficient for each of 28 different source materials versus wavelength.

Muscari, J. A.↗

The evaluation of GOES black paint materials

The purpose of this paper is to study the contamination effect of black paint materials on the GOES instrument performance. The GOES spacecraft materials were originally selected for their low outgassing properties. Samples of the materials were tested according to the ASTM E-595 test method to fulfill the total mass loss and collected volatile condensable materials criteria for traditional spacecraft material selection. Due to the instrument design, the cavity will experience high temperatures during operation greater than the specified temperature in the ASTM test. As a result of this high cavity temperature, normally stable paint materials on the painted surface may severely outgas even though they have passed the ASTM test. Further enhancement of the contaminant remaining on the mirror by UV irradiation is also a great consideration. This concern prompted an investigation into the outgassing characteristics of the black paints at the predicted operating temperatures.

Chen, Philip T.↗

Solar cells for lunar applications by vacuum evaporation of lunar regolith materials

The possibility of the direct fabrication of solar cells on the lunar surface by the vacuum evaporation of lunar regolith is examined as an alternative approach to electric power generation on the surface of the moon. The raw materials for large-scale solar cell growth could be available from the waste products generated in regolith processing for volatiles collection and oxygen extraction. The production of vast areas of solar cells can be implemented through a self-generation process whereby the power generated by grown cells is used to produce more cells.

Ignatiev, Alex↗

Outgassing Data for Selecting Spacecraft Materials

This tenth compilation of outgassing data of materials intended for spacecraft use supersedes Reference Publication 1124, Revision 2, November 1990. The data were obtained at the Goddard Space Flight Center (GSFC), utilizing equipment developed at Stanford Research Institute (SRI) under contract to the Jet Propulsion Laboratory (JPL). SRI personnel developed an apparatus for determining the mass loss in vacuum and for collecting the outgassed products. The outgassing data have been presented in three different ways in order to facilitate material selection. In Section A, the materials are divided by category into the 18 probable uses, such as adhesives, greases, paints, potting compounds, and so forth. In Section B, all the materials contained in Section A are listed in alphabetical order by the manufacturer's identification. In Section C, the only materials listed are those having 'Total Mass Loss' (TML) and Collected Volatile Condensable Materials (CVCM) equal to or lower than a maximum 1.0 percent TML and a maximum 0.10 percent CVCM. These are grouped by use, as in Section A.

Campbell, William A., Jr.↗

Outgassing Data for Selecting Spacecraft Materials

Outgassing data, derived from tests at 398 K (125 C) for 24 hours in a vacuum as per ASTM E 595-84, have been compiled for numerous materials for spacecraft use. The data presented are the total mass loss (TML) and the collected volatile condensable materials (CVCM). The various materials are compiled by likely usage and alphabetically.

Walter, Neil A.↗