Search NASA⌕ Search

SEARCH · Search NASA

Results for “Voltage stability assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Extended real-time voltage instability identification method based on synchronized phasor measurements

This paper presents an extended adaptive approach designed to accurately estimate the Thévenin equivalent parameters using phasor measurements at a given bus for measurements lying in any of four quadrants of the PQ-plane. The improvement is achieved by using a new condition to properly update the estimated parameters after an initial guess. Based on an adaptive philosophy, the proposed approach can correctly account for the intrinsic nonlinearities of a power system, can provide a real-time estimation of Thévenin parameters, and does not require network topology knowledge. The method is validated using the Kundur 2-area system, showing estimation improvements compared to the current adaptive approach and the classical recursive least-squares method. The proposed approach is able to estimate both sides of the system with respect to the measurement bus. In addition, a data-driven voltage stability index is developed. To illustrate the performance of the proposed approach in a larger power system, a voltage stability assessment is carried out on the IEEE 39-bus system, considering the action of overexcitation limiters of generators and nonlinear loads. The proposed approach is suitable for applications that require an accurate Thévenin equivalent estimation in real-time, such as for voltage stability assessment. The new approach provides a reliable tool for the system operators to make proper and timely decisions.

42 ENGINEERING↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interpretable Data-Driven Probabilistic Power System Load Margin Assessment with Uncertain Renewable Energy and Loads

The increasing uncertainties caused by the high-penetration of stochastic renewable generation resources poses a significant threat to the power system voltage stability. To address this issue, this paper proposes a probabilistic deep kernel learning enabled surrogate model to extract the hidden relationship between uncertain sources, i.e., wind power and loads, and load margin for probabilistic load margin assessment (PLMA). Unlike other deep learning approaches, a kernel SHAP provides the sensitivity analysis as well as interpretability of the inputs to outputs influences. This allows identifying the critical factors that affect load margin so that corrective control can be initiated for stability enhancement. Numerical results carried out on the IEEE 118-bus power system demonstrate the accuracy and efficiency of the proposed data-driven PLMA scheme.

deep kernel learning↗

Promising performance of sulfide catholytes compared to halide alternatives in NMC811 cathodes for sheet-type sulfide solid-state batteries

Sulfide-based solid-state batteries (SSBs) show promise in achieving energy densities over 350 Wh/kg, yet challenges persist with their incorporation of high-voltage, nickel-rich layered oxide cathodes, such as LiNi₀.₈Mn₀.₁Co₀.₁O₂ (NMC811), due to the poor oxidation stability of sulfide solid-state electrolytes (SSEs) like Li₆PS₅Cl (LPSCl). Although halide SSEs such as Li₃InCl₆ (LIC) and Li₃YCl₆ (LYC) have previously shown promise in stabilizing high-voltage NMC cathodes, our research reveals that sulfide SSE catholytes, particularly when combined with surface-coated NMC cathodes, deliver superior performance. Here, this investigation assesses the cycling stability of various catholytes—LPSCl, LIC, Li₁₀GeP₂S₁₂ (LGPS), combined LIC-LPSCl, and LYC-LPSCl—in SSBs with LiNbO₃-coated NMC811 cathodes against sheet-type LPSCl separators. Findings indicate that while LGPS-based cathodes maintain higher capacity retention, they yield lower deliverable capacity, and LIC cathodes experience significant electrochemical degradation. Importantly, our results underscore that sulfide SSE catholytes, in conjunction with LiNbO₃-coated cathodes, optimize the cathode-electrolyte interphase (CEI), enhancing both kinetics and mass transport. These insights provide a strategic direction for optimizing catholyte composition in the development of sheet-type sulfide-based SSBs.

Catholyte↗

Voltage and Temperature Limits of Advanced Electrolytes for Lithium-Metal Batteries

Several advanced electrolytes (mainly ether-based) have recently demonstrated excellent electrochemical performance in high energy density lithium (Li)-metal batteries. However, the safety of these ether-based electrolytes is still unknown. This work evaluates the thermal stability of these new formulations to understand their safety limits of operation in comparison to carbonate electrolytes typically used in Li-ion batteries. Electrolyte stability is assessed in conjunction with LiNi 0.8 Mn 0.1 Co 0.1 O 2 cathode and Li-metal anode at ultra-high voltages (≤ 4.8 V) and temperatures (≤ 300°C) to trigger thermal runaway, where onset and extent of heat release are monitored via isothermal microcalorimetry and differential scanning calorimetry Most ether-based electrolytes show improved thermal resilience over commercial carbonate formulations when heated up to 300°C. The thermal behavior in presence of charged cathode and Li-metal suggests that the new electrolytes may be better at stabilizing active material surfaces than carbonate electrolytes. Although extreme voltages severely destabilize the ether-based formulations, prompting thermal runaway, a phosphate based localized high concentration electrolyte exhibits superior stability over commercial carbonate electrolytes at all tested temperatures (32°C, 45°C, and 60°C). Although thermal analysis during the first charge process (as adopted in this preliminary study) may be insufficient to conclude the long-term advantages of these electrolytes, a more stable electrolyte identified under extreme voltage and temperature conditions will provide valuable guidance for the safety of future electrolyte designs.

25 ENERGY STORAGE↗

Performance, Stability, and Plume Characterization of the HERMeS Thruster with Boron Nitride Silica Composite Discharge Channel

NASA's Hall Effect Rocket with Magnetic Shielding (HERMeS) 12.5kW Technology Demonstration Unit-3 (TDU-3) has been the subject of extensive technology maturation in preparation for flight system development. Detailed performance, stability, and plume characterization tests of the thruster were performed at NASA GRC's Vacuum Facility 5 (VF-5). The TDU-3 thruster implements a magnetic topology that is identical to TDU-1. The TDU-3 boron nitride silica composite discharge channel material is different than the TDU-1 heritage boron nitride discharge channel material. Performance and stability characterization of the TDU-3 thruster was performed at discharge voltages between 300V and 600V and at discharge currents between 5A and 21.8A. The thruster performance and stability were assessed for varying magnetic field strength, cathode flow fractions between 5% and 9%, varying harness inductance, and for reverse magnet polarity. Performance characterization test results indicate that the TDU-3 thruster performance is in family with the TDU-1 levels. TDU-3's thrust efficiency of 65% and specific impulse of 2,800sec at 600V and 12.5kW exceed performance levels of SOA Hall thrusters. Thruster stability regimes were characterized with respect to the thruster discharge current oscillations (discharge current peak-to-peak and root mean square magnitudes), discharge current waveform power spectral density analysis, and maps of the current-voltage-magnetic field. Stability characterization test results indicate a stability profile similar to TDU-1. Finally, comparison of the TDU-1 and TDU-3 plume profiles found that there were negligible differences in the plasma plume characteristics between the TDU with heritage boron nitride versus the boron nitride silica composite discharge channel.

ion engines↗

Computational Investigation of MAX as Intercalation Host for Rechargeable Aluminum‐Ion Battery

Abstract Layered carbides and their analogs with MAX phase (general formula AM n+1 X n ) have emerged as promising candidates for energy storage and conversion applications. One frontier for energy storage is using MAX as an Al‐ion intercalation electrode. Given that many MAXs have Al as the A sites, the structure can potentially serve as a stable host for Al intercalation. Here in this work, 425 ternary MAX Al‐ion battery electrodes are computationally enumerated. Specifically, first principal phase diagram calculations are performed on the combinatorial space of 17 types of typical transition metals, five types of anions (C, N, B, Si, and P), three types of stoichiometries (n = 1, 2, and 3) and two types of layered stackings (α and β). Among all the ternary MAX materials, 44 candidates show reasonable synthetic accessibility, and six with extraordinary performance are predicted to be promising Al‐ion battery electrodes. With the phase stability, and electrochemical performance (average voltage, theoretical capacity, energy density, and Al diffusion barrier), the work provides a comprehensive computational assessment of the great opportunities behind MAX‐based Al‐ion batteries.

Chemistry↗

PHIL Interface Design for Use With a Voltage-Regulated Amplifier

Power hardware-in-the-loop (PHIL) has emerged as a leading strategy to thoroughly assess the impact of proprietary inverter controls on a specific power system. The development of a PHIL test bed typically involves an inverter under test, a power amplifier, controllable DC supply, and a digital real-time simulator (DRTS) to simulate the power system under study. As a result of PHIL nonidealities, a form of digital compensation within the DRTS is used, which is commonly referred to as a PHIL interface. Many existing methods use legacy power amplifiers that do not contain internal voltage regulation. These existing interface methods are based around a voltage regulator within the DRTS and do not consider the interaction with the controls in newer amplifiers. In this study, a three-step approach of PHIL interface development for modern power amplifiers with built-in voltage regulation is introduced and is validated in hardware with a 30-kW grid-following inverter.

DRTS↗

Small-Signal Stability of Grid-Forming Inverters Using Current-Limiting and Frequency Stabilization

This paper presents a small-signal stability analysis of grid-forming (GFM) inverters under current-limiting conditions. It examines how adjustments in virtual impedance angles, implemented through advanced current-limiting and frequency stabilization techniques, influence small-signal stability. This paper studies a GFM inverter control integrating a fictitious power technique stabilizing primary control by adding a virtual power term and a hybrid current limiter integrating virtual impedance in the anti-wind-up feedback with current reference saturation limiting. A small-signal model is developed to assess the impact of virtual impedance angles on GFM inverter dynamics during grid disturbances, such as voltage drops. The findings indicate that although increasing the virtual impedance angle (to make it more inductive) enhances large-signal stability and voltage support during faults, it can induce oscillations and lead to instability if the angle exceeds certain thresholds. Based on the small-signal models, this paper provides design considerations for the current-limiter impedances to ensure reliable GFM inverter behavior under grid disturbances while maintaining small-signal stability.

current limiting↗

Diffusion of acceptor dopants in monoclinic 𝛽−Ga 2⁢ O 3

𝛽−Ga 2 ⁢O 3 is a promising material for next-generation power electronics because of its ultrawide band gap and high critical breakdown voltage. However, realizing its full potential requires precise control over dopant incorporation and stability. In this work, we use first-principles calculations to systematically assess the diffusion behavior of eight potential deep-level substitutional acceptors (Au, Ca, Co, Cu, Fe, Mg, Mn, and Ni) in 𝛽−Ga 2 ⁢O 3 . We consider two key diffusion mechanisms: (i) interstitial diffusion under nonequilibrium conditions relevant to ion implantation, and (ii) trap-limited diffusion (TLD) under near-equilibrium thermal annealing conditions. Our results reveal a strong diffusion anisotropy along the 𝑏 and 𝑐 axes, with dopant behavior governed by competition between diffusion and incorporation (or dissociation) activation energies. Under interstitial diffusion, Ca$^{2+}_{i}$ and Mg$^{2+}_{i}$ show the most favorable combination of low migration and incorporation barriers, making them promising candidates for efficient doping along the 𝑏 and 𝑐 axes, respectively. In contrast, Au$^{+}_{i}$ diffuses readily, but exhibits an incorporation barrier that exceeds 5 eV, rendering it ineffective as a dopant. From a thermal stability perspective, Co$^{2+}_{i}$ shows poor activation but high diffusion barriers, which may suppress undesirable migration at elevated temperatures. Under trap-limited diffusion, the dissociation of dopant-host complexes controls mobility. Mg$^{2+}_{i}$ again emerges as a leading candidate, exhibiting the lowest dissociation barriers along both axes, whereas Co$^{2+}_{i}$ and Fe$^{2+}_{i}$ display the highest barriers, suggesting improved dopant retention under thermal stress. In conclusion, our findings guide dopant selection by balancing activation and thermal stability, essential for robust semi-insulating substrates.

Defects↗

A Laplace-Domain Circuit Model for Fault and Stability Analysis Considering Unbalanced Topology

For systems subject to unbalanced faults, analytical model building for stability assessment is a challenging task. This letter presents a straightforward modeling approach. A generalized dynamic circuit representation is achieved by use of the Laplacian transform variable s . Here, we translate the voltage and current relationship at the fault location into the relationship of three subsystems. The final circuit model is an interconnected sequence network with impedances in the Laplace domain. This circuit can be directly converted from a steady-state sequence network. This modeling procedure is illustrated by an example case of an induction motor served by a grid through a series compensated line. Electromagnetic transient simulation results demonstrate that sub-synchronous oscillations can be mitigated when a single-line to ground fault is applied at the motor terminal. Stability analysis results based on the dynamic circuit corroborate the simulation results. What's more, the derived circuit effortlessly reveals why unbalance can enhance stability.

42 ENGINEERING↗

Large-signal Stability Analysis of Grid-forming Inverters with Equivalent-circuit Models

Here, this paper proposes an energy function-based direct method for large-signal stability assessment of grid-forming (GFM) inverters leveraging an equivalent-circuit representation of all involved control- and physical-layer dynamics. Three different primary controls, a standard inner-current outer-voltage cascaded-control architecture, output LCL filter, and reference-current saturation limiting are featured in the modeling and analysis framework. A composite energy function for the GFM inverter is obtained by summing up individual energy contributions gleaned from the circuit representation. The approach can readily be generalized to different primary controls, output-filter arrangements, and current limiters since it is based on a circuit-theoretic foundation. Numerical simulations validate the efficacy of the approach in estimating the critical clearing time following a large-signal disturbance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of Grid-Forming Inverter Controls for Grid-Connected and Islanded Microgrid Integration

Autonomous grid-forming (GFM) inverter testbeds with scalable platforms have attracted interest recently. In this study, a self-synchronized universal droop controller (SUDC) was adopted, tested, and scaled in a small network and a test feeder using a real-time simulation tool to operate microgrids without synchronous generators. We presented a novel GFM inverter control adoption to better understand the dynamic behavior of the inverters and their scalability, which can impact the distribution system (DS). This paper provides a steady-state and transient analysis of the GFM power inverter controller via simulation to better understand voltage and frequency stabilization and ensure that the critical electric loads are not affected during a prolonged power outage. The controllers of the GFM inverter are simulated in HYPERSIM to examine voltage and frequency fluctuations. This analysis includes assessing the black start capability for photovoltaic microgrids, both grid-connected and islanded, during transient fault conditions. The high photovoltaic PV penetration levels open exciting opportunities and challenges for the DS. The GFM inverter control demonstrated appropriate response times for synchronization, connection, and disconnection to the grid. The DS has become more resilient and independent of fossil fuels by increasing the penetration of inverter-based distributed energy resources (DERs).

Ward, Laura (ORCID:0000000345501581)↗

Preliminary Results of Field Emission Cathode Tests

Preliminary screening tests of field emission cathodes such as chemical vapor deposited (CVD) diamond, textured pyrolytic graphite, and textured copper were conducted at background pressures typical of electric thruster test facilities to assess cathode performance and stability. Very low power electric thrusters which provide tens to hundreds micronewtons of thrust may need field emission neutralizers that have a capability of tens to hundreds of microamperes. From current voltage characteristics, it was found that the CVD diamond and textured metals cathodes clearly satisfied the Fowler-Nordheim emission relation. The CVD diamond and a textured copper cathode had average current densities of 270 and 380 mA/sq cm, respectively, at the beginning-of-life. After a few hours of operation the cathode emission currents degraded by 40 to 75% at background pressures in the 10(exp -5) Pa to 10(exp -4) Pa range. The textured pyrolytic graphite had a modest current density at beginning-of-life of 84 mA/sq cm, but this cathode was the most stable of all. Extended testing of the most promising cathodes is warranted to determine if current degradation is a burn-in effect or whether it is a long-term degradation process. Preliminary experiments with ferroelectric emission cathodes, which are ceramics with spontaneous electric polarization, were conducted. Peak current densities of 30 to 120 mA/sq cm were obtained for pulse durations of about 500 ns in the 10(exp -4) Pa pressure range.

Sovey, James S.↗

Reliability of double probe measurements in nanodusty plasmas

Abstract Nonthermal plasmas are attractive sources for nanoparticles synthesis, however, their plasma properties are notoriously difficult to assess due to the chemically reactive environment and high nanoparticle concentrations. Here, we are using a floating double probe to measure the plasma properties of a nanoparticle-forming argon:silane plasma. We demonstrate good stability of current–voltage characteristics over several minutes of operation. However, unexpectedly larger electron temperatures are measured with increasing the silane mole fraction. To test the validity of these results, we developed a zero-dimensional global model to investigate the effect of the presence of nanoparticles on the plasma properties. Using this model, we show that increasing particle concentration leads to an increasing electronegativity of the plasma, causing an increase of the reduced electric field. However, this causes only a moderate increase in mean electron energy, in contrast to the much larger increase measured by the double probe. We argue that these large electron temperatures are based on the fact that a double probe measures an ‘apparent’ electron temperature, which is defined by the negative inverse slope of the logarithm of the electron energy probability function (EEPF) at an energy corresponding to the probe’s floating potential. As the silane mole fraction is increased, the plasma becomes more electronegative and the probe’s floating potential moves closer to the plasma potential. Combined with the strong non-Maxwellian EEPF, this leads to the large apparent electron temperatures obtained by the probe. Thus, the apparent electron temperatures measured with the double probe do not follow the trends in mean electron energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Critical Insights into Solvent Choice for High-Voltage Organosulfur Electrolytes

Organosulfur electrolytes are promising candidates for enabling high-voltage cathodes due to their superior oxidative stability compared to conventional carbonate-based systems. However, their viscous nature and inability to passivate the anode necessitate the use of passivating agents and diluents to achieve meaningful charge/discharge rates. In this study, we investigate the use of cyclic fluorinated carbonates (CFCs) to form passivating interphases on electrode surfaces, aiming to optimize electrolyte performance in high-voltage systems. Electrolyte formulations containing 1.2 M LiPF 6 in a CFC:sulfone:1,1,2,2-tetrafluoroethyl-2,2,3,3-tetrafluoropropylether (TTE) mixture (2/5/3 V/V/V) were assessed in full-cell configurations with a LiNi 0.8 Mn 0.1 Co 0.1 O 2 (FCG-NMC) cathode and a 4.5 V upper cutoff potential. The results reveal that 3-3-3-trifluoropropylene carbonate (TFPC) combined with ethyl methyl sulfone (EMS) optimizes electrolyte performance, resulting in lower resistance buildup and reduced capacity loss compared to commercial electrolytes. We also explore the failure mechanisms of several carbonate/sulfone mixtures and identify key considerations for electrolyte compatibility in high-voltage systems. TFPC enhances cycling stability and lowers overall cell resistance, while fluoroethylene carbonate (FEC) formulations, despite higher ionic conductivity, fail to form adequate passivation layers, leading to rapid capacity loss. Additionally, EMS provides superior physical properties that avoid common failure modes seen with other sulfone solvents like methyl isopropyl sulfone and tetramethylene sulfone. Furthermore, this study underscores the importance of carefully selecting passivating carbonates and sulfone solvents to improve electrolyte performance and expand the viability of high-voltage electrolyte systems.

LiNi0.8Mn0.1Co0.1O2 cathode↗

T&D LIBRA: Simulation Framework for Transmission and Distribution Load and IBR Assessment

This paper introduces T&D LIBRA, a HELICS-based dynamic co-simulation framework designed for transmission and distribution (T&D) load and inverter-based resource assessment. This framework is designed to model interactions between single-phase induction motors (i.e., Motor-D), distributed energy resources (DERs) and the transmission network, emphasizing system stability during fault conditions. The primary objective of this research is to study the fault-induced delayed voltage recovery (FIDVR) behavior of the T&D networks using the co-simulation framework and to compare the results with conventional PSS/E only simulations. Simulations are validated using T&D co-simulations with a single distribution node and the IEEE 123-bus distribution test case. The co-simulation results demonstrate the value of using T&D co-simulations to capture motor stalling, DER tripping and other sources of voltage diversity on distribution networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effects of periodic discharges

Periodic capacity checks are assessed as well as the effects of periodic discharges on the cycle life and the performance of cells during the cycle life. Topics discussed include the effect of the amount of electrolyte on cell capacity at 35 C; battery design for spacecraft; electrolyte starvation theory; battery separator degradation; negative electrode stability; voltage regulation; operating temperatures; and integration of reconditioning systems using microprocessors.

Ford, F. E.↗