Search NASA⌕ Search

SEARCH · Search NASA

Results for “Voltmeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Inexpensive automatic ranging for digital voltmeters and frequency counters

Seven integrated circuits incorporated at very low cost into frequency counters and digital voltmeters performing a voltage-to-frequency conversion permit automatic range changing. Extra decades are switched into and out of the counting chain as a function of the counter during the previous counting period.

Roller, R. F.↗

Programmed multiplexing system simultaneously monitors several voltages

System consists of digital voltmeter with binary coded decimal output, programmer, multiplexer, and two to six gated digital displays. Maximum number of circuits monitored is determined by digital voltmeter, rate of change of parameter being measured and complexity of multiplexer design.

Wright, L. S.↗

Onsite testing of pressure sampling

Portable test instrument containing controller, pressure port identification, 5-V power source for transducer excitation, and digital voltmeter to test pressure sampling valves completely, including leak and plug check before, during, or after installation in any location or environment. Controller comprises 117/24-Vac 100-watt transformer, bridge rectifier, capacitive-discharge stepper, and constant voltage source for homing sampling valve. It also includes 5-V regulated power supply and bipolar digital voltmeter having 10-uV resolution.

Mallory, R.↗

Lockout/Tagout (LOTO) Simulator

The Lockout/Tagout (LOTO) Simulator is a portable training aid, or demonstration tool, designed to physically illustrate real-time critical-safety concepts of electrical lockout/tagout. The objective is to prevent misinterpretations of what is off and what is on during maintenance and repair of complex electrical systems. The simulator is designed in the form of a hinged box that opens up and stands on its own as an easel for demonstrations. On the outer face of the unit is a simulated circuit breaker box housing the switches. The breakers control the main power to the unit, a light bulb, and an electrical control cabinet. The light bulb is wired so that either of two breakers can provide power to it. When power is sent to the electrical control cabinet, a red indicator light illuminates. Inside the cabinet is the power supply from a personal computer. The power supply produces a 12-V dc output that is sent over to a small fan next to it, also from a computer, and an amber light on the front of the cabinet illuminates. A separate switch powers the fan on and off. The power supply is behind a plastic shield to protect against exposure to live conductors. Electrical banana jacks are mounted in the plastic shield to allow a voltmeter to be connected safely when opening the cabinet and taking a meter reading to verify de-energization as part of a simulation exercise. This LOTO simulator prototype is designed and fabricated as an all-in-one unit. All accessories can be stored inside the hinged case, and there is a handle on top for ease of transport. The circuit breaker labels attach with hook and loop fasteners so that they may be moved and changed to fit the training or demonstration scenario. The warning signs and labels on the electrical control box are magnetic, allowing for easy reconfiguration to emulate different equipment setups. A specially designed magnetic cover was made to disguise the indicator lights for demonstrations when these indicators are not used. The cover is disguised as an arc flash safety label that would typically be found on such a cabinet. One indicator light has a separate switch that can take it offline. This is to allow for demonstration to trainees on why it is important not to completely rely on indicator lights, but that they should always take a meter reading at the exposed conductors to absolutely verify de-energization before exposure. A clear plastic barrier and banana jacks inside the cabinet provide a safe way to plug in a voltmeter for demonstrations without exposure to the hazards of energized equipment. A small remote control unit is wired into the fan circuit. The remote allows the demonstrator to turn the fan on and off, provided that all of the breakers and switches leading to it are configured on as well. The remote feature was added in order to demonstrate the importance of starting the lockout/tagout task with energized equipment, then powering it down, isolating it, and locking it out to ensure that the correct breakers have been locked out.

Scheer, Jennifer↗

Piezoresistive gage tests pin-connector sockets

Connector pin consisting of a piezoresistive crystal, retainer spring and a bridge circuit with voltmeter is used to test connector sockets and may be adapted for multiple socket testing.

Bond, W. W.↗

Determination of nonlinear resistance voltage-current relationships by measuring harmonics

Test configuration measures harmonic signal amplitudes generated in nonlinear resistance. Vacuum-type voltmeter measures low frequency sinusoidal input signal amplitude and wave-analyzer measures amplitude of harmonic signals generated in junction. Input signal harmonics amplitude must not exceed that of harmonics generated in nonlinear resistance.

Stafford, J. M.↗

Rapid detection of bacteria in foods and biological fluids

Simple and inexpensive apparatus, called "redox monitoring cell," rapidly detects presence of bacteria. Bacteria is detected by measuring drop in oxygen content in test solution. Apparatus consists of vial with two specially designed electrodes connected to sensitive voltmeter.

Fealey, R. D.↗

Low-cost clearance indicator for high speed turbomachinery

System consists of hermetically sealed capacitance probe, compact electronic driver, power supply, and oscilloscope and/or voltmeter for readout. System requires no mechanical connection to the rotating parts of turbomachinery, and does not disrupt rotor mainstream flow pattern. It can be effectively used in other applications to measure dynamic clearances between moving and stationary parts.

Evans, R. C.↗

Demodulator for carrier transducers

A carrier type transducer is supplied with a carrier wave via an audio amplifier, a filter, a frequency divider, and an oscillator. The carrier is modulated in accordance with the parameter being measured by the transducer and is fed to the input of a digital data system which may include a voltmeter. The output of the oscillator and the output of each stage of the divider are fed to an AND or a NAND gate and suitable variable and fixed delay circuits to the command input of the digital data system. With this arrangement, the digital data system is commanded to sample at the proper time so that the average voltage of the modulated carrier is measured. It may be utilized with ancillary circuitry for control of the parameter

Roller, R. F.↗

High resolution spectroscopic measurements of carbon dioxide and carbon monoxide

A modified 1.83 meter Jarrell-Ash spectrometer is reported. The instrument was double passed and achieved a resolution of 0.05 cm at 15 micrometers. An integrating voltmeter was used to optimize the available integration time. Data were obtained in the 15 micrometer and 4.3 micrometer band of CO2 and the 4.6 micrometer and 2.3 micrometer bands of CO. The data are summarized and examples of typical spectra are given. All the data are stored on IBM cards.

Chaney, L. W.↗

Conductive elastomeric extensometer

An extensometer was used for measuring surface area changes of the human body caused by expansion and contraction of the body. A relatively thin and wide strain responsive conductive elastomeric band was adapted for application to a part of the body, such as around a limb or the trunk of the body. The elastomeric band is incorporated as a resistor in a balanced bridge circuit. Expansion or contraction of the portion of the body on which the elastomeric band is applied causes a change in the resistance of the band and a resultant imbalance of the bridge circuit. The output of the amplifier in volts is suitable for proving the desired reading through a recorder, oscilloscope or voltmeter.

Gause, R. L.↗

Contributions to the problem of piezoelectric accelerometer calibration

After discussing the principal calibration methods for piezoelectric accelerometers, an experimental setup for accelerometer calibration by the reciprocity method is described It is shown how the use of a lock-in voltmeter eliminates errors due to viscous damping and electrical loading.

Jakab, I.↗

Gyroflex data transmittal and data acquisition system analysis

Data obtained from the evaluation of GYROFLEX gyro is presented herein, along with a description of the data acquisition system. In addition, the appendices contain an analysis of the voltmeter used for data collection, and the filtering technique employed. It is shown that the test setup is satisfactory for testing GYROFLEX gyros.

Peckham, C.↗