Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volumetric Inspection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Robotic NDE inspection of advanced solid rocket motor casings

The Advanced Solid Rocket Motor program determined the need to inspect ASRM forgings and segments for potentially catastrophic defects. To minimize costs, an automated eddy current inspection system was designed and manufactured for inspection of ASRM forgings in the initial phases of production. This system utilizes custom manipulators and motion control algorithms and integrated six channel eddy current data acquisition and analysis hardware and software. Total system integration is through a personal computer based workcell controller. Segment inspection demands the use of a gantry robot for the EMAT/ET inspection system. The EMAT/ET system utilized similar mechanical compliancy and software logic to accommodate complex part geometries. EMAT provides volumetric inspection capability while eddy current is limited to surface and near surface inspection. Each aspect of the systems are applicable to other industries, such as, inspection of pressure vessels, weld inspection, and traditional ultrasonic inspection applications.

Mcneelege, Glenn E.↗

X-Ray Computed Tomography Inspection of the Stardust Heat Shield

The "Stardust" heat shield, composed of a PICA (Phenolic Impregnated Carbon Ablator) Thermal Protection System (TPS), bonded to a composite aeroshell, contains important features which chronicle its time in space as well as re-entry. To guide the further study of the Stardust heat shield, NASA reviewed a number of techniques for inspection of the article. The goals of the inspection were: 1) to establish the material characteristics of the shield and shield components, 2) record the dimensions of shield components and assembly as compared with the pre-flight condition, 3) provide flight infonnation for validation and verification of the FIAT ablation code and PICA material property model and 4) through the evaluation of the shield material provide input to future missions which employ similar materials. Industrial X-Ray Computed Tomography (CT) is a 3D inspection technology which can provide infonnation on material integrity, material properties (density) and dimensional measurements of the heat shield components. Computed tomographic volumetric inspections can generate a dimensionally correct, quantitatively accurate volume of the shield assembly. Because of the capabilities offered by X-ray CT, NASA chose to use this method to evaluate the Stardust heat shield. Personnel at NASA Johnson Space Center (JSC) and Lawrence Livermore National Labs (LLNL) recently performed a full scan of the Stardust heat shield using a newly installed X-ray CT system at JSC. This paper briefly discusses the technology used and then presents the following results: 1. CT scans derived dimensions and their comparisons with as-built dimensions anchored with data obtained from samples cut from the heat shield; 2. Measured density variation, char layer thickness, recession and bond line (the adhesive layer between the PICA and the aeroshell) integrity; 3. FIAT predicted recession, density and char layer profiles as well as bondline temperatures Finally suggestions are made as to future uses of this technology as a tool for non-destructively inspecting and verifying both pre and post flight heat shields.

McNamara, Karen M.↗

Rapid detection and quantification of impact damage in composite structures

It is shown that a multidisciplinary nondestructive evaluation approach for impact damage detection in composite structures can be used to produce a more efficient inspection. The multidisciplinary NDE approach relies on fast large area thermographic inspections along with detailed ultrasonic volumetric imaging. The thermal inspection technique rapidly identifies the impact damage. The ultrasonic volumetric imaging quantifies the impact generated delaminations through the volume of the structure.

Smith, Barry T.↗

Rapid detection and quantification of impact damage in composite structures

NDE results from thermographic and volumetric ultrasonic techniques are presented to illustrate the multidisciplinary NDE approach to impact-damage detection in such composite structures as are increasingly prevalent in helicopters. Attention is given to both flat-panel and 'y-stiffened' panel specimens; these were fabricated either with kevlar or carbon fiber through-the-thickness reinforcements. While thermal inspection identifies impact damage, volumetric imaging quantifies the impact-generated delaminations through the volume of the structure.

Zalameda, Joseph N.↗

Method and Apparatus for Non-Destructive Evaluation of Materials

Methods and apparatus for characterizing composite materials for manufacturing quality assurance (QA), periodic inspection during the useful life, or for forensic analysis/material testing. System are provided that relate eddy-current sensor responses to the fiber layup of a composite structure, the presence of impact damage on a composite structure with or without a metal liner, volumetric stress within the composite, fiber tow density, and other NDE inspection requirements. Also provided are systems that determine electromagnetic material properties and material dimensions of composite materials from capacitive sensor inspection measurements. These properties are related to the presence of buried defects in non-conductive composite materials, moisture ingress, aging of the material due to service or environmental/thermal exposure, or changes in manufacturing quality.

Goldfine, Neil J.↗

Method and Apparatus for Non-Destructive Evaluation of Materials

Methods and apparatus for characterizing composite materials for manufacturing quality assurance (QA), periodic inspection during the useful life, or for forensic analysis/material testing. System are provided that relate eddy-current sensor responses to the fiber layup of a composite structure, the presence of impact damage on a composite structure with or without a metal liner, volumetric stress within the composite, fiber tow density, and other NDE inspection requirements. Also provided are systems that determine electromagnetic material properties and material dimensions of composite materials from capacitive sensor inspection measurements. These properties are related to the presence of buried defects in non-conductive composite materials, moisture ingress, aging of the material due to service or environmental/thermal exposure, or changes in manufacturing quality.

Goldfine, Neil J.↗

Ultra-Pure, High Endurance Liquid Bladder with Volume Sensor for Space Applications

The NASA Portable Life Support System (PLSS) for the Exploration Extravehicular Mobility Unit (xEMU) incorporates a Feedwater Supply Assembly (FSA) to store consumable cooling water. The FSA accepts pure water prior to each Extra-Vehicular Activity (EVA), then supplies this water to a membrane evaporator at ambient suit pressure during the eight hour EVA. The FSA must function reliably for hundreds of EVAs over 15 years of service without introducing contamination that may accumulate and foul the membrane. We present a unique design that combines the benefits of a flexible fluoropolymer bladder with the strength and convenience of a rigid tank, providing an ultra-pure, ambient-pressure reservoir with fill-drain cycle life exceeding 3000, internal pressure tolerance exceeding 100 psi, high volumetric efficiency, near-zero dead volume, optical transparency for visual inspection, simplified mounting, and very low mass. We also incorporate a novel volume sensor suitable for both microgravity and arbitrarily accelerated environments and capable of real-time monitoring with accuracy on the order of 2.5% full scale. Analytical predictions are supported by experimental test data from a mature subscale prototype.

PLSS Portable Life Support System FSA Feedwater Su↗

Development of Natural Flaw Samples for Evaluating Nondestructive Testing Methods for Foam Thermal Protection Systems

Low density polyurethane foam has been an important insulation material for space launch vehicles for several decades. The potential for damage from foam breaking away from the NASA External Tank was not realized until the foam impacts on the Columbia Orbiter vehicle caused damage to its Leading Edge thermal protection systems (TPS). Development of improved inspection techniques on the foam TPS is necessary to prevent similar occurrences in the future. Foamed panels with drilled holes for volumetric flaws and Teflon inserts to simulate debonded conditions have been used to evaluate and calibrate nondestructive testing (NDT) methods. Unfortunately the symmetric edges and dissimilar materials used in the preparation of these simulated flaws provide an artificially large signal while very little signal is generated from the actual defects themselves. In other words, the same signal are not generated from the artificial defects in the foam test panels as produced when inspecting natural defect in the ET foam TPS. A project to create more realistic voids similar to what actually occurs during manufacturing operations was began in order to improve detection of critical voids during inspections. This presentation describes approaches taken to create more natural voids in foam TPS in order to provide a more realistic evaluation of what the NDT methods can detect. These flaw creation techniques were developed with both sprayed foam and poured foam used for insulation on the External Tank. Test panels with simulated defects have been used to evaluate NDT methods for the inspection of the External Tank. A comparison of images between natural flaws and machined flaws generated from backscatter x-ray radiography, x-ray laminography, terahertz imaging and millimeter wave imaging show significant differences in identifying defect regions.

Workman, Gary L.↗

The Utility of a Small Pressurized Rover with Suit Ports for Lunar Exploration: A Geologist's Perspective

Rover trade study: As summarized recently, mission simulations at Black Point Lava Flow (Arizona) that included realistic extravehicular activity (EVA) tasking, accurate traverse timelines, and an in-loop science CAPCOM (or SciCOM) showed that a small pressurized rover (SPR) was a better mobility asset than an unpressurized rover (UPR). Traverses within the SPR were easier on crew than spending an entire day in a spacesuit, enhancing crew productivity at each station. The SPR, named Lunar Electric Rover (LER), and sometimes called the Space Exploration Vehicle (SEV), could also provide shelter during a suit malfunction, radiation event, or medical emergency that might occur on the Moon. Intravehicular activity (IVA) capabilities: From within the vehicle, crew could describe and photo-document distant features during drives between stations, as well as in the near-field, directly in front of the LER, providing an ability to begin EVA planning on approach to each outcrop prior to egress. The vehicle can rotate 360º without any lateral movement, providing views in all directions. It has high-visibility windows, a ForeCam, AftCam, port and starboard cameras, docking cameras, and a GigaPan camera. EVA capabilities: To reduce timeline, mass, and volumetric overhead, rapid egress and ingress were envisioned, replacing an airlock with lower cabin pressure than on the International Space Station and suit ports on the aft cabin wall [2]. When needed for closer inspection and sample collecting, crew could egress in about 10 minutes through suit ports. Crew use SuitCams for additional photo-documentation, transmit mobile observations verbally, and collect surface materials. Typical simulations involved 3 to 4 EVA stations/day and 2 to 3 hr/day of boots on the ground. This allowed crew to explore a far larger territory, with more complex geological and in situ resource utilization (ISRU) features, than would a single, longer-duration EVA at one location, while also minimizing crew time in a spacesuit. Additionally, the vehicle could be driven with crew locked into the suit ports. This approach could involve a driver in the cockpit with a suited crewmember in a suit port, or the vehicle could be driven from the aft deck with both crewmembers in their suit ports. This approach was used when distances between stops were short enough that vehicle ingress and egress were less efficient than remaining in the suits and driving. Utility of suit ports: The advantages of suit ports were clearly demonstrated in those field-based trade studies. To illustrate those advantages further, consider the consequences of a SPR without suit ports at the Apollo 17 landing site. At that site, the crew's second EVA was an approximately 18 km loop conducted in a UPR, called the Lunar Roving Vehicle (LRV), in 7 hr 36 min 56 s. The traverse was composed of 5 formal stations, plus 8 additional LRV stations where crew made brief scientific stops. In a scenario involving a SPR without suit ports, crew would go EVA through an airlock and probably be limited to a single EVA per day. In that case, crew could drive the SPR ~9 km from the landing site to station 2, go EVA, and complete station 2 tasks. However, to conduct station 3 tasks, the crew would then need to walk approximately 3 km to station 3, while ground control in Houston tele-robotically drives the LER to station 3. A walk of approximately 3 km is possible, as that is what the Apollo 14 crew did before LRVs were deployed, but it is a lengthy and potentially grueling EVA. Assuming crew completes station 3 tasks, they would likely need to re-enter the SPR, ending the day's EVA, and return to the landing site. They would not be able to walk the additional distances to stations 4 and 5 (the latter being about 6 km from station 3). Thus, crew in an SPR without suit ports would require two days to accomplish the same tasks Apollo 17 crew completed in a single day. If a future crew is involved in long duration traverses on the lunar surface, the deployment of a vehicle with suit ports would probably be a better solution.

Kring, David A.↗

Investigation of Keeper Erosion in the NSTAR Ion Thruster

The goal of the present investigation was to determine the cause for the difference in the observed discharge keeper erosion between the 8200 hr wear test of a NASA Solar Electric Propulsion Technology Applications Readiness (NSTAR) engineering model thruster and the ongoing extended life test (ELT) of the NSTAR flight spare thruster. During the ELT, the NSTAR flight spare ion thruster experienced unanticipated erosion of the discharge cathode keeper. Photographs of the discharge keeper show that the orifice has enlarged to slightly more than twice the original diameter. Several differences between the ELT and the 8200 hr wear test were initially identified to determine any effects which could lead to the erosion in the ELT. In order to identify the cause of the ELT erosion, emission spectra from an engineering model thruster were collected to assess the dependence of keeper erosion on operating conditions. Keeper ion current was measured to estimate wear. Additionally, post-test inspection of both a copper keeper-cap was conducted, and the results are presented. The analysis indicated that the bulk of the ion current was collected within 2-mm radially of the orifice. The estimated volumetric wear in the ELT was comparable to previous wear tests. Redistribution of the ion current on the discharge keeper was determined to be the most likely cause of the ELT erosion. The change in ion current distribution was hypothesized to caused by the modified magnetic field of the flight assemblies.

Domonkos, Matthew T.↗

The dregs of crystallization in Zagami

The Zagami shergottite is a basaltic meteorite which formed when a phenocryst-bearing lava flow was emplaced at or near the surface of Mars. Recently, a cm-sized olivine-rich lithology has been identified in Zagami by Mossbauer spectroscopy. Olivine is extremely rare in shergottites, particularly in Zagami and Shergotty, where it occurs only as minute grains. We report petrologic and microprobe studies of this olivine-rich lithology. This material represents the last few percent of melt and is highly enriched in phosphates, opaques and mesostases, all of which are late-stage crystallization products. Phosphates replaced augite as a phenocryst phase when the magma became saturated in P. This late stage melt also includes a fayalite-bearing, multi-phase intergrowth which crystallized after the melt became too rich in iron to crystallize pigeonite. We can now reconstruct the entire crystallization history of the Zagami shergottite from a deep-seated magma chamber to crystallization of the final few percent of melt in a near-surface dike or thick flow. Small pockets (tens of microns) of late-stage melt pockets are ubiquitous but volumetrically minor in Zagami. We do not know the physical relationship between these areas and the cm-sized olivine-rich material described here. It is possible that these small pockets were mobile, forming larger areas. Perhaps inspection of the entire hand specimen of Zagami would clarify this relationship.

Mccoy, T. J.↗

The JPL advanced propulsion module motor chamber

A Kevlar 49/epoxy chamber has been developed for the advanced propulsion module motor. This chamber was successfully designed, fabricated, and hydroproof-tested at 511.6 N/sq cm. The fabrication, interior dimensional inspection, and proof test are discussed, showing that the chamber will be capable of achieving the design burst pressure of 639.8 N/sq cm. The projected chamber growth at 448.2 N/sq cm is presented based on the strain gage and volumetric growth data collected in that proof test.

Jensen, W. M.↗

ECC Ozonesonde Reliability, Observations, and Comparisons with Satellite Ozone Instruments

Electrochemical Concentration Cell (ECC) ozone instruments depend on the quality of care exercised in their pre-flight preparation. The ozone-measuring project conducted at Goddard Space Flight Center's Wallops Flight Facility uses a number of mechanisms designed to inspect the ECC for anomalies that may interfere with the reception of valid ozone profiles. Complete electronic testing of the instrument, individually and when coupled to its radiosonde has led to exceptional monitoring of ozone for detecting long-term atmospheric changes. A number of factors are considered when preparing an ECC instrument for flight. These basically are specific calibrations of pump efficiency, volumetric flow rate, temperature of the air entering the pump, and background current. The concentration of the potassium iodide solution is also important. Wallops is the only site using a UV photometer (Dasibi) to compare ECC ozone output at various concentrations of ozone that allows adjustment to be made to offsets that may appear in the balloon-borne instrument prior to release. All of the above procedures allow identification of potential problems before release of the ECC instrument. Procedures followed at Wallops also are employed in Brazil, and Ascension Island where NASA has cooperative agreements in place to obtain ozonesondes data. All ECC instruments are prepared 3-4 weeks prior to the day of observation. We will briefly describe the instrumental tests employed. These tests have included simultaneous dual observations to compare the effect of different solution concentrations, comparison of sensors of different manufacturers, and comparisons with surface- and space-based instrumentation such as the Dobson Spectrophotometer and satellites. Vertical profiles of ozone from Arctic, mid-latitudes, and Antarctica will be discussed. Although not unusual, the data reveals ozone structure that correlate well with typical atmospheric temperatures and possibly relative humidity. Finally, vertical ozone distribution, compared with remotely measured ozone from lidar and satellite, will be discussed. Specific comparisons between ECC and HALOE measurements, integrated ECC total ozone overburden with the EP-TOMS and the Dobson, as well as comparisons with lidar are discussed. Results show agreement and some disagreement between the in situ measurements of the ECC and the remote instruments. We postulate reasons for the differences, or biases, which in spite of the excellent ECC quality control during pre-flight preparation and data analysis processes, may be due to uncertainties in both measuring systems.

Schmidlin, F. J.↗

Vertical bloch line memory

A new read gate design for the vertical Bloch line (VBL) memory is disclosed which offers larger operating margin than the existing read gate designs. In the existing read gate designs, a current is applied to all the stripes. The stripes that contain a VBL pair are chopped, while the stripes that do not contain a VBL pair are not chopped. The information is then detected by inspecting the presence or absence of the bubble. The margin of the chopping current amplitude is very small, and sometimes non-existent. A new method of reading Vertical Bloch Line memory is also disclosed. Instead of using the wall chirality to separate the two binary states, the spatial deflection of the stripe head is used. Also disclosed herein is a compact memory which uses vertical Bloch line (VBL) memory technology for providing data storage. A three-dimensional arrangement in the form of stacks of VBL memory layers is used to achieve high volumetric storage density. High data transfer rate is achieved by operating all the layers in parallel. Using Hall effect sensing, and optical sensing via the Faraday effect to access the data from within the three-dimensional packages, an even higher data transfer rate can be achieved due to parallel operation within each layer.

Katti, Romney R.↗

Modeling and Simulation for Exercise Vibration Isolation and Stabilization System Design

The microgravity environment that crew members experience on orbit presents a well-known health challenge, particularly when it comes to loss of muscle and bone mass. To counteract these negative effects, exercise countermeasures play a critical role in the daily routine of the crew on the International Space Station (ISS). To help inform requirements for upcoming exploration missions such as the Gateway Program, a new device, called the European Enhanced Exploration Exercise Device (E4D), is being built by the European Space Agency through their contractor, the Danish Aerospace Company. The E4D is being demonstrated on the ISS and is unique from other current exercise devices in that it provides four separate modalities in a single device: resistive, cycle ergometry, seated aerobic rowing, and rope pulling. To support the integration of E4D on ISS, a passive Vibration Isolation and Stabilization (VIS) system was required by NASA, and this responsibility was given to the Johnson Space Center. This paper describes the end-to-end process of modeling, simulation, and analysis used to inform the mechanical design of the VIS system. The process begins with the collection of representative exerciser motion capture (MoCap) through ground-based testing with the developmental E4D in both the Prototype Immersive Technology (PIT) Laboratory and the Active Response Gravity Offload System (ARGOS) facility at the Johnson Space Center. These collected MoCap data are processed through human biomechanics modeling to create forcing functions as input to a multibody dynamics simulation of the combined E4D/VIS system, with numerous resulting outputs. These outputs include microgravity accelerations, overall system displacements, internal and transmitted loads, as well as collisions. Microgravity accelerations are compared for compliance against ISS requirements while displacements are used for sway space determinations on the design and volumetric constraints within the targeted module. Internal loads are supplied to the supporting stress analysis teams and external loads for structural loads and dynamics teams, both at NASA and ESA. Finally, contact and clearance analysis is performed using the simulation to eliminate potential design issues. To ensure that the elements of the multibody simulation were verified and validated, correlation against multiple VIS related ground hardware testbeds was performed and characterized. In addition to the isolation part of the VIS problem, stabilization is also key to the integrated performance and evaluation. Due to the difficulty in defining ISS requirements in this area, the stability of the exerciser was inspected via analysis. Loss of balance was defined analytically as occurring when the resultant force vector acting on the exerciser lies outside the base of support of the feet. Both the VIS and E4D teams have recently gone through their Critical Design Reviews (CDRs) and the iterative model-based approach has been integral to inform mechanical design, particularly in the case of the VIS. This same end-to-end approach is now being applied for the Gateway Program, where an Exploration Exercise Device (EED) derived from the E4D and notional VIS for the device are under concept development.

Countermeasures↗

A Novel Ultrasonic Method for Characterizing Microstructural Gradients in Tubular Structures

Ultrasonic velocity and time-of-flight (TOF) imaging that uses back surface reflections to gage volumetric material quality is highly suited for quantitative characterization of microstructural gradients including those due to pore fraction, density, fiber fraction, and chemical composition variations. However, a weakness of conventional pulse echo ultrasonic velocity and TOF imaging is that the image shows the effects of thickness as well as microstructural variations, unless the part is uniformly thick. This limits this imaging method's usefulness in practical applications. Prior studies have described a pulse echo TOF based ultrasonic imaging method that requires using a single transducer in combination with a reflector plate placed behind samples which, eliminates the effect of thickness variation in the image. In those studies, this method was successful at isolating ultrasonic variations due to material in plate like samples of silicon nitride, metal matrix composite, and polymer matrix composite. In this study, the method is engineered for inspection of more complex shaped structures- those having (hollow) tubular or curved geometry. The experimental inspection technique and results are described as applied to a polymer matrix composite "proof of concept" tube that contains machined patches of various depths and an as manufactured monolithic silicon nitride ceramic tube that might be used in "real world" applications.

Roth, Don J.↗

Scaling up the Single Transducer Thickness-Independent Ultrasonic Imaging Method for Accurate Characterization of Microstructural Gradients in Monolithic and Composite Tubular Structures

Ultrasonic velocity/time-of-flight imaging that uses back surface reflections to gauge volumetric material quality is highly suited for quantitative characterization of microstructural gradients including those due to pore fraction, density, fiber fraction, and chemical composition variations. However, a weakness of conventional pulse-echo ultrasonic velocity/time-of-flight imaging is that the image shows the effects of thickness as well as microstructural variations unless the part is uniformly thick. This limits this imaging method's usefulness in practical applications. Prior studies have described a pulse-echo time-of-flight-based ultrasonic imaging method that requires using a single transducer in combination with a reflector plate placed behind samples that eliminates the effect of thickness variation in the image. In those studies, this method was successful at isolating ultrasonic variations due to material microstructure in plate-like samples of silicon nitride, metal matrix composite, and polymer matrix composite. In this study, the method is engineered for inspection of more complex-shaped structures-those having (hollow) tubular/curved geometry. The experimental inspection technique and results are described as applied to (1) monolithic mullite ceramic and polymer matrix composite 'proof-of-concept' tubular structures that contain machined patches of various depths and (2) as-manufactured monolithic silicon nitride ceramic and silicon carbide/silicon carbide composite tubular structures that might be used in 'real world' applications.

Roth, Don J.↗

NEPP Evaluation of Automotive Grade Tantalum Chip Capacitors

Automotive grade tantalum (Ta) chip capacitors are available at lower cost with smaller physical size and higher volumetric efficiency compared to military/space grade capacitors. Designers of high reliability aerospace and military systems would like to take advantage of these attributes while maintaining the high standards for long-term reliable operation they are accustomed to when selecting military-qualified established reliability tantalum chip capacitors (e.g., MIL-PRF-55365). The objective for this evaluation was to assess the long-term performance of off-the-shelf automotive grade Ta chip capacitors (i.e., manufacturer self-qualified per AEC Q-200). Two (2) lots of case size D manganese dioxide (MnO2) cathode Ta chip capacitors from 1 manufacturer were evaluated. The evaluation consisted of construction analysis, basic electrical parameter characterization, extended long-term (2000 hours) life testing and some accelerated stress testing. Tests and acceptance criteria were based upon manufacturer datasheets and the Automotive Electronics Council's AEC Q-200 qualification specification for passive electronic components. As-received a few capacitors were marginally above the specified tolerance for capacitance and ESR. X-ray inspection found that the anodes for some devices may not be properly aligned within the molded encapsulation leaving less than 1 mil thickness of the encapsulation. This evaluation found that the long-term life performance of automotive grade Ta chip capacitors is generally within specification limits suggesting these capacitors may be suitable for some space applications.

Automotive↗