Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vs30”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Advanced High-Performance Computational Modeling of the Seismic Response of High-Hazard and/or Nuclear Facilities and Critical Infrastructure at the NNSS

New methods for predicting the amplitude and variability of ground shaking from earthquakes (and explosions) are needed for seismic hazard analysis for buildings, nuclear power plants, and critical infrastructure at the NNSS. We are comparing existing 1-D and new 3-D geophysical methods for estimating the shear-wave velocity structure in the upper 30 meters of the ground surface (Vs30), which plays a major role in ground motion amplification and seismic response of buildings. We evaluate the performance of these methodologies at the U1a Complex at the NNSS and develop simple 1-D and high-resolution 3-D Vs30 models. We then emplace these high-resolution models into a background seismic velocity model. We will collaborate with Lawrence Livermore National Laboratory (LLNL) to conduct numerical modeling of the ground shaking at the NNSS using their high-performance computing technology and state-of-the-art ground motion simulation methodology. The primary work that was completed in FY 2019 was to acquire the seismic systems and familiarize staff at the NNSS with their use. We also worked on developing a collection plan with the Device Assembly Facility (DAF) at the NNSS, but due to time constraints and other ongoing projects at the DAF, we had to use U1a as a backup. We were able to coordinate the seismic survey, and we will complete the collection of seismic data in FY 2020. Additionally, during FY 2019, we completed the geologic framework model (GFM) for the U1a Complex and modeled the Yucca fault. LLNL worked with us through FY 2019 to prepare the data files for their modeling software and tested the software for reliability. In FY 2020 we will develop the end-to-end capability so that any facility could easily be modeled and the expected shaking from a local earthquake understood. The work in FY 2020 will include building fault models from the GFM and finalizing the velocity model analysis. The final simulations will be run for multiple rupture models, and final assessments will demonstrate the seismic hazard at the U1a Complex.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Attenuation Tomography of Northern California and the Yellow Sea / Korean Peninsula from Coda-source Normalized and Direct Lg Amplitudes

Inversions for regional attenuation (1/Q) of Lg are performed in two different regions. The path attenuation component of the Lg spectrum is isolated using the coda-source normalization method, which corrects the Lg spectral amplitude for the source using the stable, coda-derived source spectra. Tomographic images of Northern California agree well with one-dimensional (1-D) Lg Q estimated from five different methods. We note there is some tendency for tomographic smoothing to increase Q relative to targeted 1-D methods. For example in the San Francisco Bay Area, which contains high attenuation relative to the rest of it's region, Q is over-estimated by {approx}30. Coda-source normalized attenuation tomography is also carried out for the Yellow Sea/Korean Peninsula (YSKP) where output parameters (site, source, and path terms) are compared with those from the amplitude tomography method of Phillips et al. (2005) as well as a new method that ties the source term to the MDAC formulation (Walter and Taylor, 2001). The source terms show similar scatter between coda-source corrected and MDAC source perturbation methods, whereas the amplitude method has the greatest correlation with estimated true source magnitude. The coda-source better represents the source spectra compared to the estimated magnitude and could be the cause of the scatter. The similarity in the source terms between the coda-source and MDAC-linked methods shows that the latter method may approximate the effect of the former, and therefore could be useful in regions without coda-derived sources. The site terms from the MDAC-linked method correlate slightly with global Vs30 measurements. While the coda-source and amplitude ratio methods do not correlate with Vs30 measurements, they do correlate with one another, which provides confidence that the two methods are consistent. The path Q{sup -1} values are very similar between the coda-source and amplitude ratio methods except for small differences in the Da-xin-anling Mountains, in the northern YSKP. However there is one large difference between the MDAC-linked method and the others in the region near stations TJN and INCN, which point to site-effect as the cause for the difference.

58 GEOSCIENCES↗

ANN-based ground motion model for Turkey using stochastic simulation of earthquakes

SUMMARY Turkey is characterized by a high level of seismic activity attributed to its complex tectonic structure. The country has a dense network to record earthquake ground motions; however, to study previous earthquakes and to account for potential future ones, ground motion simulations are required. Ground motion simulation techniques offer an alternative means of generating region-specific time-series data for locations with limited seismic networks or regions with seismic data gaps, facilitating the study of potential catastrophic earthquakes. In this research, a local ground motion model (GMM) for Turkey is developed using region-specific simulated records, thus constructing a homogeneous data set. The simulations employ the stochastic finite-fault approach and utilize validated input-model parameters in distinct regions, namely Afyon, Erzincan, Duzce, Istanbul and Van. To overcome the limitations of linear regression-based models, artificial neural network is used to establish the form of equations and coefficients. The predictive input parameters encompass fault mechanism (FM), focal depth (FD), moment magnitude (Mw), Joyner and Boore distance (RJB) and average shear wave velocity in the top 30 m (Vs30). The data set comprises 7359 records with Mw ranging between 5.0 and 7.5 and RJB ranging from 0 to 272 km. The results are presented in terms of spectral ordinates within the period range of 0.03–2.0 s, as well as peak ground acceleration and peak ground velocity. The quantification of the GMM uncertainty is achieved through the analysis of residuals, enabling insights into inter- and intra-event uncertainties. The simulation results and the effectiveness of the model are verified by comparing the predicted values of ground motion parameters with the observed values recorded during previous events in the region. The results demonstrate the efficacy of the proposed model in simulating physical phenomena.

Karimzadeh, Shaghayegh (ORCID:0000000337531676)↗

A Bayesian Monte Carlo inversion of spatial auto-correlation (SPAC) for near-surface Vs structure applied to both broad-band and geophone data

SUMMARY We propose a new Bayesian method to reveal the Vs structure of the near surface of the earth using spatial autocorrelation (SPAC) functions and apply this new method to synthetic, broad-band and geophone data sets. The principle of SPAC is introduced, and an implementation of the Bayesian Monte Carlo inversion (BMCI) for modelling SPAC coherency functions is described. To demonstrate its effectiveness, BMCI is applied to synthetic tests, data from 14 SPAC array sites in the Salt Lake Valley (SLV), Utah, and two arrays (one broad-band and one geophone) located in south central Utah. The Vs models derived from previous SPAC analysis of the 14 SLV sites differ by 10 per cent at most from those determined by BMCI and lie within uncertainties determined for the BMCI models. These agreements demonstrate the effectiveness of the BMCI method. The synthetic tests and applications to the SLV SPAC data show BMCI has great potential to resolve Vs structure down to at least 400 m. To achieve resolution for deeper Vs structure, longer duration deployments, wider array apertures, and additional seismometers or geophones can be used. Additionally, when the target frequencies are greater than 0.1 Hz, there is no apparent disadvantage in using geophone data for BMCI compared to broad-band data. Most significantly, BMCI places a quantifiable constraint on the uncertainties of the Vs models as well as Vs30.

58 GEOSCIENCES↗

NEAR-SURFACE GEOPHYSICAL CHARACTERIZATION OF A HOLOCENE FAULT CONDUCIVE TO GEOTHERMAL FLOW NEAR PYRAMID LAKE, NEVADA

Linear deposits of calcium carbonate tufa columns mark recent faults that cut 11 ka Lake Lahontan sediments at Astor Pass, north of Pyramid Lake, Nevada. Throughout the Great Basin, faults appear to control the location of geothermal resources by providing pathways for fluid migration. Reservoir-depth (greater than 1 km) seismic imaging at Astor Pass reveals a fault that projects to one of the lines of tufa columns at the surface. The presence of the tufa deposits suggests this fault carried warm geothermal waters through the lakebed clay sediments in recent time. The warm fluids deposited the tufa when they hit cold Lake Lahontan water at the lakebed. Lake Lahontan covered this location 11 ka to a depth of at least 60 m. In collaboration with the Pyramid Lake Paiute Tribe, an Applied Geophysics class at UNR investigated the near-surface geophysical characteristics of this fault. The survey at and near the tufa columns comprises near-surface Pwave seismic reflection and refraction, electrical resistivity tomography, nearsurface refraction microtremor arrays, nine near-surface direct-current resistivity soundings, magnetic surveys, and gravity surveys. The refraction microtremor results show shear velocities near tufa and faults to be marginally lower, compared to Vs away from the faults. Overall, the 30-m depth-averaged shear velocities are low, less than 300 m/s, consistent with the lakebed clay deposits. These results indicate that no seismically fast (> 500 m/s) tufa deposits are present below the surface at or near the tufa columns. Vs30 averages were for example 274 ± 13 m/s on the fault, 287 ± 2 m/s at 150 m east of the fault, and 290 ± 15 m/s at 150 m west of the fault. The P-velocity refraction optimization results similarly indicate a lack of high-velocity tufa buried below the surface in the Lahontan sediments, reinforcing the idea that all tufa was deposited above the lakebed surface. The seismic results provide a negative test of the hypothesis that deposition of the lakebeds in the Quaternary buried and preserved older tufa columns within the section. Near-surface Wenner arrays with a-spacings up to 30 m show a higher resistivity near the faults, and tufa, than away from the faults. Resistivity averages within a few meters of the surface were 33 ± 17 ohm-m on the fault, 13 ± 3 ohm-m east of the fault, and 9 ± 3 ohm-m west of the fault. It is possible that the geothermal waters are fresher, and more resistive, than waters held in the lakebed clays. Water samples from more than 1 km depth in exploration wells have a TDS of 2500 p.p.m., nearly drinking-water quality. The relatively resistive water, perhaps localized by greater permeability along the fault, could explain the higher resistivity measured near the fault. The results show that there is no high-velocity, high-resistivity tufa along the faults below the surface, so we are unable to use buried tufa to locate the faults that may promote geothermal upwelling in this area. We further hypothesize that as sedimentation buried the tufa during the Quaternary, warm geothermal waters re-dissolved it, and re-precipitated it in the cold lake-bottom water.

15 GEOTHERMAL ENERGY↗

Site Integration and Regulatory Considerations for a Nuclear Power Plant Colocated with Industrial Facilities: Colocation Studies for a Petroleum Refinery, Methanol Plant, and Wood Pulp Plant

This research explores the colocation of nuclear power plants (NPPs) with industrial applications. Three existing industrial sites were considered to demonstrate the siting process and illuminate technological gaps for future work. The three applications demonstrated for colocation here are a petroleum refinery, a methanol production plant, and a pulp and paper plant. This study uses a modified version of the EPRI siting criteria to explore the geological and demographic characteristics of the location of the current industrial site, as well as exploring external hazards from the industrial plant and its surrounding land use. Data was collected from public databases to estimate site characteristics. We then discuss how the site characteristics may impact the ability to colocate an NPP with an industrial application. The application site and 5 additional sites were explored for each application to give a general indication of the siting implications for an NPP in each area. The hazards for each industrial application was also explored to determine how colocation may impact reactor safety. The following gaps have been identified and should be explored in future research on colocation of NPPs with petroleum refineries, methanol plants, and pulp and paper plants: - There is a variety of industrial use, hazards, and pipelines in the surrounding area. A more thorough review of these hazards should be considered for colocation. - In general, the whole region around some applications seems to have softer soil, with implications for large site preparation costs. Further site investigations should prioritize looking into the geotechnical conditions. - Applications along coastlines are susceptible to flooding and hurricanes. The benefits of colocation should be weighed against the potential design implications. - The benefits of natural gas pipeline infrastructure in place should be explored further. If heat supply from the NPP is not required or not feasible due to the distance between the NPP and the application, there may be an opportunity to supply hydrogen to the plant through an existing pipeline. - Because there are several collocated industrial plants in the regions for the refinery and methanol plant, the benefits of sharing resources from the NPP should be explored further. This may open up additional sites for colocation. The following knowledge gaps were identified for the colocation of NPPs with these three industries, and industrial applications in general. These gaps are: - While the STAND tool contains many important characteristics for the reactor siting process, it is not calibrated for the colocation of NPPs with industrial facilities. - There are aspects of both the NPP and industrial application that need to be quantified for a siting analysis. Particularly, we need to understand the water intake requirements for NPPs and each application. - Further work may focus on adapting the STAND site comparison methodology to comparison of sites for co-location. This will involve using the data documented in this report as a starting point and performing a comprehensive and quantitative comparison. - Without spending significant resources, it would be impossible to gather data for each site to evaluate all aspects of siting. One approach to finding data and understanding its implications to siting is looking at FSARs for existing plants. For example, most sites considered in this study have small Vs30 values, indicating soft soil. However, there are NPPs located in the vicinity of most of the sites (e.g., Waterford Steam Electric Station near New Orleans) and reviewing available site characteristics and geotechnical data for these NPPs, might provide further information for siting. - The siting analysis in this study indicates that colocation of the NPP with the industrial site could be difficult based on external hazards, cooling requirements, weather, or population. We need to determine the impact of distance between the two facilities on cost and quality of energy transport. - This study did not touch on socioeconomic impacts for NPP colocation with industrial facilities. The input-output analysis methodology could be applied to the communities referenced in this study to determine the socioeconomic impact of these projects. - Similarly, the impacts of colocation on emergency planning was not explored in this study. The impacts on emergency planning infrastructure are somewhat related to the socioeconomic impacts, and could be explored using a similar methodology. - This study also did not address physical and cybersecurity, which will be important aspects of co-location [ref] . Cybersecurity will be important, regardless of the distance, but physical security will be important if the facilities are located very closely. Physical security might also be important for the steam lines between the plants, unless they are determined to be non-safety significant. - In many site l

08 HYDROGEN↗

Site Integration and Regulatory Considerations for an NPP Colocated with a Petroleum Refinery, Methanol Plant, and Wood Pulp Plant

This research explores the colocation of nuclear power plants (NPPs) with industrial applications. Three existing industrial sites were considered to demonstrate the siting process and illuminate technological gaps for future work. The three applications demonstrated for colocation here are a petroleum refinery, a methanol production plant, and a pulp and paper plant. This study uses a modified version of the EPRI siting criteria to explore the geological and demographic characteristics of the location of the current industrial site, as well as exploring external hazards from the industrial plant and its surrounding land use. Data was collected from public databases to estimate site characteristics. We then discuss how the site characteristics may impact the ability to colocate an NPP with an industrial application. The application site and 5 additional sites were explored for each application to give a general indication of the siting implications for an NPP in each area. The hazards for each industrial application was also explored to determine how colocation may impact reactor safety. The following gaps have been identified and should be explored in future research on colocation of NPPs with petroleum refineries, methanol plants, and pulp and paper plants: - There is a variety of industrial use, hazards, and pipelines in the surrounding area. A more thorough review of these hazards should be considered for colocation. - In general, the whole region around some applications seems to have softer soil, with implications for large site preparation costs. Further site investigations should prioritize looking into the geotechnical conditions. - Applications along coastlines are susceptible to flooding and hurricanes. The benefits of colocation should be weighed against the potential design implications. - The benefits of natural gas pipeline infrastructure in place should be explored further. If heat supply from the NPP is not required or not feasible due to the distance between the NPP and the application, there may be an opportunity to supply hydrogen to the plant through an existing pipeline. - Because there are several collocated industrial plants in the regions for the refinery and methanol plant, the benefits of sharing resources from the NPP should be explored further. This may open up additional sites for colocation. The following knowledge gaps were identified for the colocation of NPPs with these three industries, and industrial applications in general. These gaps are: - While the STAND tool contains many important characteristics for the reactor siting process, it is not calibrated for the colocation of NPPs with industrial facilities. - There are aspects of both the NPP and industrial application that need to be quantified for a siting analysis. Particularly, we need to understand the water intake requirements for NPPs and each application. - Further work may focus on adapting the STAND site comparison methodology to comparison of sites for co-location. This will involve using the data documented in this report as a starting point and performing a comprehensive and quantitative comparison. - Without spending significant resources, it would be impossible to gather data for each site to evaluate all aspects of siting. One approach to finding data and understanding its implications to siting is looking at FSARs for existing plants. For example, most sites considered in this study have small Vs30 values, indicating soft soil. However, there are NPPs located in the vicinity of most of the sites (e.g., Waterford Steam Electric Station near New Orleans) and reviewing available site characteristics and geotechnical data for these NPPs, might provide further information for siting. - The siting analysis in this study indicates that colocation of the NPP with the industrial site could be difficult based on external hazards, cooling requirements, weather, or population. We need to determine the impact of distance between the two facilities on cost and quality of energy transport. - This study did not touch on socioeconomic impacts for NPP colocation with industrial facilities. The input-output analysis methodology could be applied to the communities referenced in this study to determine the socioeconomic impact of these projects. - Similarly, the impacts of colocation on emergency planning was not explored in this study. The impacts on emergency planning infrastructure are somewhat related to the socioeconomic impacts, and could be explored using a similar methodology. - This study also did not address physical and cybersecurity, which will be important aspects of co-location [ref] . Cybersecurity will be important, regardless of the distance, but physical security will be important if the facilities are located very closely. Physical security might also be important for the steam lines between the plants, unless they are determined to be non-safety significant. - In many site l

08 - HYDROGEN↗