Search NASA⌕ Search

SEARCH · Search NASA

Results for “WASHING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Impacts of Solvent Washing on the Electrochemical Remediation of Commercial End-of-Life Cathodes

Changes to surface structure and chemistry occurring throughout the functional lifetime of lithium-ion batteries (LIBs) may impact the effectiveness of end-of-life rejuvenation methods. Solvent washing prior to electrochemical relithiation is shown to both increase relithiation efficacy and beneficially alter the interfacial chemistry of heavily degraded industrial cathode material. Four common solvents (acetone, diethyl carbonate, isopropyl alcohol, propylene carbonate) are employed to investigate the role of varying physicochemical solvent properties on the mechanism of capacity recovery. Electrochemical (dQ/dV, EIS), structural (XRD), and chemical (SPME-GC-MS) analysis techniques are employed to comprehensively analyze solvent-cathode interactions. Highly nucleophilic solvents (acetone, DEC) are found to reduce cathode charge-transfer impedance and enable stable impedance growth throughout subsequent cycling. The use of nucleophilic solvents under mechanically aggressive washing conditions may also enable the reintroduction of bulk lattice oxygen, thereby restoring anionic redox capacity. Further, the four solvents are found to selectively remove a subset of surface species from the aged cathode material, including residual electrolyte, additives, and electrolyte-additive reaction products, which are qualitatively analyzed. Surface species removal by each solvent is correlated with the electrochemical performance of the correspondingly washed cathode, highlighting the importance of an optimized washing protocol to effective remediation in the context of direct LIB recycling. For the material under study, the use of a simple acetone washing protocol prior to electrochemical relithiation enables up to 174% capacity recovery relative to unwashed/relithiated black mass.

ADVANCED PROPULSION SYSTEMS↗

Low-temperature processed high-performance flexible perovskite solar cells via rationally optimized solvent washing treatments

High performance planar-heterojunction (PHJ) perovskite (CH3NH3PbI3) solar cells fabricated through lowtemperature annealing are demonstrated. Simple spin-coating with an optimized solvent washing process readily forms homogeneous and crystalline perovskite thin films. The perovskite films fabricated via this solvent washing process show a low dependence on annealing temperature in achieving high crystallinity and large grain size, prerequisites for high efficiency perovskite solar cells. The solar cell device fabricated by solvent washing and 100 C annealing exhibited a high power conversion efficiency (PCE) over 14% with high short circuit current density (JSC) of 19.3 mA cm 2 and fill factor (FF) of 0.80. More importantly, the device annealed at low temperature (<90 C) also yields high PCEs of over 12%. This enables us to fabricate flexible solar cells at low-temperatures with promising PCE as high as 9.43%. This study demonstrates that this optimized solvent washing process is highly relevant for low-cost rollto-roll (R-2-R) processing of high performance perovskite solar cells.

14 SOLAR ENERGY↗

Wash Penalty Factors: Insight into the Effects of Water Wash Down of Building Materials for Radionuclide/Nuclear (Rn) Decontamination - 20153

The release of radiological material to the urban environment can have a devastating socio-economic impact. In an urban release scenario, areas around the dispersal epicenter and any areas contaminated via atmospheric deposition may require extensive decontamination. Most recently, our group reported the decontamination efficacy of pressurized water washing of common porous building materials, and compared the penetration depth of the contaminations before and after exposure to pressurized tap water. Here, we continue evaluation of the decontamination efficacy of wash solutions based on potassium (K{sup +}) salt for cesium (Cs), strontium (Sr), and europium (Eu) contaminations on common building surfaces. The surfaces included: the cement used in concrete, the aggregate used in concrete, intact concrete, roadway asphalt, asphalt shingles, and latex paint. We deposited solutions of {sup 137}Cs, {sup 85}Sr, and {sup 152}Eu onto numerous common building materials and exposed these materials to a static bath or low-pressure flow of tap water, 0.1 M potassium chloride (KCl), and 0.5 M KCl. The decontamination efficacy and the depth profile for residual contamination were measured to determine the conditions under which applying a wash solution has benefit compared to physically removing the surface material. To aid in these analyses, we introduced a 'wash penalty factor' to quantify the degree to which contamination migrated into the bulk material by the action of the wash method. On asphalt, 70-80% of the radionuclides were found to be within 0.02 mm of the surface. Cs{sup +} bonded to negative charge sites on the surface of the mineral aggregate (used in concrete) so decontamination was improved by ion exchange with K{sup +}. Sr{sup 2+} is soluble and removed by water, while not bonding to aggregate or demonstrating solubility in the liquid asphalt. Eu{sup 3+} is precipitated and not removed in gentle wash but displays mobility within the pore space that suggests its presence as a colloid. Concrete is more porous than asphalt, and 80% of the radionuclides were within 0.2 mm of the surface for {sup 137}Cs and {sup 152}Eu and 50- 80% for {sup 85}Sr. On concrete, Cs{sup +} bonds similarly to asphalt. Sr{sup 2+} bonds to the cement or precipitates from the alkaline pore water. Eu{sup 3+} sorbs to the cement and then precipitates. In brick, the results for Cs{sup +} and Sr{sup 2+} suggested that diffusion of ions from deeper in the coupon was important. Eu{sup 3+} is removed poorly due to precipitation. We will explain and report example wash penalty factors that vary from 0 to > 1 for the various methods and the implications for deciding when to implement wash down methods. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laser damage by ns and sub-ps pulses on hafnia/silica anti-reflection coatings on fused silica double-sided polished using zirconia or ceria and washed with or without an alumina wash step.

Sandia's Large Optics Coating Operation has extensive results of laser induced damage threshold (LIDT) testing of its anti-reflection (AR) and high reflection coatings on substrates pitch polished using ceria and washed in a process that includes an alumina wash step. The purpose of the alumina wash step is to remove residual polishing compound to minimize its role in laser damage. These LIDT tests are for multi longitudinal mode, ns class pulses at 1064 nm and 532 nm (NIF-MEL protocol) and mode locked, sub-ps class pulses at 1054 nm (Sandia measurements), and show reasonably high and adequate laser damage resistance for coatings in the beam trains of Sandia's Z-Backlighter terawatt and petawatt lasers. An AR coating in addition to coatings of our previous reports confirms this with LIDTs of 33.0 J/cm{sup 2} for 3.5 ns pulses and 1.8 J/cm{sup 2} for 350 fs pulses. In this paper, we investigate both ceria and zirconia in doublesided polishing (common for large flat Z-Backlighter laser optics) as they affect LIDTs of an AR coating on fused silica substrates washed with or without the alumina wash step. For these AR coated, double-sided polished surfaces, ceria polishing in general affords better resistance to laser damage than zirconia polishing and laser damage is less likely with the alumina wash step than without it. This is supported by specific results of laser damage tests with 3.5 ns, multi longitudinal mode, single shot pulses at 1064 nm and 532 nm, with 7.0 ns, single and multi longitudinal mode, single and multi shot pulses at 532 nm, and with 350 fs, mode-locked, single shot pulses at 1054 nm.

36 MATERIALS SCIENCE↗

SLUDGE BATCH 7 (SB7) WASHING DEMONSTRATION TO DETERMINE SULFATE/OXALATE REMOVAL EFFICIENCY AND SETTLING BEHAVIOR

To support Sludge Batch 7 (SB7) washing, a demonstration of the proposed Tank Farm washing operation was performed utilizing a real-waste test slurry generated from Tank 4, 7, and 12 samples. The purpose of the demonstration was twofold: (1) to determine the settling time requirements and washing strategy needed to bring the SB7 slurry to the desired endpoint; and (2) to determine the impact of washing on the chemical and physical characteristics of the sludge, particularly those of sulfur content, oxalate content, and rheology. Seven wash cycles were conducted over a four month period to reduce the supernatant sodium concentration to approximately one molar. The long washing duration was due to the slow settling of the sludge and the limited compaction. Approximately 90% of the sulfur was removed through washing, and the vast majority of the sulfur was determined to be soluble from the start. In contrast, only about half of the oxalate was removed through washing, as most of the oxalate was initially insoluble and did not partition to the liquid phase until the latter washes. The final sulfur concentration was 0.45 wt% of the total solids, and the final oxalate concentration was 9,900 mg/kg slurry. More oxalate could have been removed through additional washing, although the washing would have reduced the supernatant sodium concentration.The yield stress of the final washed sludge (35 Pa) was an order of magnitude higher than that of the unwashed sludge ({approx}4 Pa) and was deemed potentially problematic. The high yield stress was related to the significant increase in insoluble solids that occurred ({approx}8 wt% to {approx}18 wt%) as soluble solids and water were removed from the slurry. Reduction of the insoluble solids concentration to {approx}14 wt% was needed to reduce the yield stress to an acceptable level. However, depending on the manner that the insoluble solids adjustment was performed, the final sodium concentration and extent of oxalate removal would be prone to change. As such, the strategy for completing the final wash cycle is integral to maintaining the proper balance of chemical and physical requirements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Role of washing solvents in defining the magnetic performance of Sm 2 Fe 17 N 3 obtained by reduction diffusion

Calciothermic reduction-diffusion (RD) is one of the leading synthesis methods for Sm 2 Fe 17 N 3 (SmFeN), but sintering of such RD-derived powders is hampered by oxidation and CaO byproducts. Here, we systematically evaluate how post-synthesis washing solvents govern powder chemistry and magnetic performance. RD-synthesized SmFeN powder was washed with several aqueous and non-aqueous solvents using identical washing protocols. This was followed by an assessment of both the as-washed powder as well as after annealing at 425 °C. Phase content was quantified by synchrotron PXRD and Rietveld refinement and SEM/EDS. The oxygen content of the powders was determined via inert gas fusion and the magnetization by DC magnetometry. While all aqueous-based solutions were able to remove CaO, the non-aqueous solutions were only effective with extended washing times. Prior to annealing, the crystalline phases and magnetic properties of the as-washed powders were largely the same regardless of washing solvent. However, differences emerge after annealing, where water-based washing markedly lowers the coercivity (H c ~3.8-4.3 kOe). In contrast, non-aqueous NH 4 Cl-methanol washing protocols were more effective in preserving coercivity (H c ~4.9-5.9 kOe). We attribute this to lower oxygen content in the non-aqueous samples (~9,400 ppm v ~6,400 ppm, respectively) which in turn reduced the formation of α-Fe during annealing. These results highlight the importance of solvent choice in washing RD-synthesized SmFeN and demonstrate that non-aqueous protocols, which better limit oxidation, outperform aqueous solvents despite the need for longer washing times.

36 MATERIALS SCIENCE↗

Flume and single-pass washing systems for fresh-cut produce processing: Disinfection by-products evaluation

Free chlorine is widely used in fresh-cut produce washing to minimize microbial cross-contamination, but its application can also lead to the formation of harmful disinfection byproducts (DBPs). This study compared DBPs in process water and washed produce during commercial operation. Samples of shredded lettuce and diced cabbages washed in chlorinated water in the traditional double-flume wash and novel immersion-free single-pass wash systems were collected at multiple time points and locations from the processing lines. A suite of 33 conventional and emerging DBPs, including 4 trihalomethanes (THMs), 9 haloacetic acids (HAAs), 9 nitrogenous DBPs (N-DBPs), and 11 carbonaceous DBPs (C-DBPs), were investigated. Overall, N-DBPs and HAAs dominated the concentration of detected DBPs. Wash water in the flumes contained 7–111 folds higher DBP levels compared to that in the single-pass system, with the abundance of DBPs following the order of N-DBPs > HAAs > C-DBPs > THMs. DBPs were detected on washed produce, presenting primarily in the forms of N-DBPs and HAAs followed by C-DBPs and THMs. While higher levels of DBPs were detected in flume-washed produce, the final potable water rinse significantly reduced the DBP concentration in these products. The concentrations of THMs and HAAs on these washed products were used to estimate potential exposure via consumption of fresh-cut produce and the levels were below the daily allowable exposure for drinking water standard established by the U.S. Environmental Protection Agency. The detected high concentration and potential toxicity of N-DBPs indicate the need for further research. Here, the findings of this study advance the understanding of the formation and removal of DBPs during wash processes, and identify additional research opportunities for further reduction in DBPs and food safety improvement.

59 BASIC BIOLOGICAL SCIENCES↗

Urban wash-off of tire wear particles

Tire wear particles (TWPs) are an important class of microplastics due to their toxicity and abundance. Because most TWPs are generated on impervious road surfaces, urban wash-off is the critical first phase of waterborne transport from their zone of production to stormwater drainage. However, little is known about the driving factors behind their mobilization. In this study, we use a rainfall simulator to investigate how surface roughness, rainfall intensity, and surface slope affect wash-off behaviors of TWPs. We also analyze how the size and shape of mobilized TWPs change over the course of simulated storm events. We found that low surface roughness, high rainfall intensity (most significant factor), and low slope result in the most rapid conveyance of TWP load. On average, large particles (>1000 µm) travelled faster than small particles (<125 µm). Particle shape explained a very small amount of variance in TWP wash-off velocity but was found to be more important under higher surface roughness conditions. In addition to wash-off velocity, we found similar conditions controlled the percent mobilization of TWPs. Low surface roughness and high rainfall intensity resulting in higher TWP wash-off rates is consistent with mineral sediment wash-off behavior. Conversely, low surface slope and large particle size leading to faster conveyance is directly opposed to mineral sediment wash-off. Our findings suggest drag-dominated flow and that sufficient runoff depth is the most important parameter governing TWP wash-off. These findings are important first steps to understanding wash-off behaviors of TWPs and informing future modeling efforts and mitigation strategies.

13 HYDRO ENERGY↗

Characterization of the SRNL-Washed Tank 51 Sludge Batch 10 Qualification Sample

Savannah River National Laboratory (SRNL) personnel have been requested to qualify the next sludge batch (Sludge Batch 10 – SB10) for processing at the Defense Waste Processing Facility (DWPF). To accomplish this task, Savannah River Remediation (SRR) sent SRNL two 3-L samples of Tank 51H slurry to be characterized, washed, and then used in a lab-scale demonstration of the DWPF flowsheet. Sample HTF-51-19-114 was received on January 28, 2020, and HTF-51-20-15 was received on February 4, 2020. SRNL washed the Tank 51H sample per the Tank Farm washing strategy. During washing, material from H Canyon Tanks 16.3 and 16.4 was also added to the Tank 51 samples to simulate canyon discharges subsequent to sampling. A part of the qualification process is extensive radionuclide and chemical characterization of the SRNL-washed Tank 51H slurry. This report documents the chemical characterization of the washed slurry; radiological characterization will be documented in a separate report. The major supernatant components, elements on a weight percent calcined basis, and the weight percent solids of the SRNL-washed sample were comparable to the Tank Farm projections, with the exception of free hydroxide and carbonate. Therefore, this SRNL-washed sample is suitable for further SB10 qualification activities and SRR planning for SB10.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of Potential Impacts of Free Chlorine during Washing of Fresh-Cut Leafy Greens on Escherichia coli O157:H7 Cross-Contamination and Risk of Illness

Addition of chlorine-based antimicrobial substances to fresh-cut leafy green wash water is done to minimize microbial cross-contamination during processing. We developed the FDA Leafy Green Risk Assessment Model (FDA-LGRAM) to quantify the impact of free chlorine concentration in wash water during fresh-cut lettuce processing on the extent of water-mediated cross-contamination between shredded lettuce and the associated risk of illness due to exposure to Escherichia coli O157:H7. At different contamination prevalence and levels of E. coli O157:H7 on incoming lettuce heads, the model compared the predicted prevalence of contaminated fresh-cut lettuce packages and the risk of illness per serving between: (1) a scenario where fresh-cut lettuce was packaged without washing; and (2) scenarios involving washing fresh-cut lettuce with different levels of free chlorine (0 ppm, 5 ppm, 10 ppm, 15 ppm, and 20 ppm) prior to packaging. Our results indicate that the free chlorine level in wash water has a substantial impact on the predicted prevalence of contaminated fresh-cut lettuce packages and the risk of illness associated with E. coli O157:H7 in fresh-cut lettuce. Results showed that the required level of free chlorine that can minimize water-mediated cross-contamination and reduce the corresponding risk of illness depended on contamination prevalence and levels of E. coli O157:H7 on incoming lettuce heads. Our model also indicated that the pathogen inactivation rate in wash water via free chlorine was a key model parameter that had a significant impact on the extent of cross-contamination during washing and the predicted associated risk of illness.

59 BASIC BIOLOGICAL SCIENCES↗

A conceptual evaluation framework for the water and sanitation for health facility improvement tool (Wash Fit)

Healthcare facilities (HCFs) in low- and middle-income countries frequently lack water, sanitation and hygiene (WASH) services that are adequate to implement infection prevention and control (IPC) practices, decrease healthcare-associated infections and antimicrobial resistance, and provide quality healthcare. The Water and Sanitation for Health Facility Improvement Tool (WASH FIT), initially published in 2017 and updated in 2018, is a risk-based, continuous improvement framework. The tool aims to improve WASH and related facility management and may contribute to quality of care (QoC) efforts. To date, there is no guidance available on how to monitor and evaluate the use of this tool nor is there rigorous evidence on its effectiveness. We developed a conceptual WASH FIT evaluation framework by drawing from the broader WASH, health systems strengthening, and QoC evidence base. This framework provides a common basis to plan, implement, monitor, and evaluate potential inputs, outputs, outcomes, and impacts from applying WASH FIT. Routine use of the tool, coupled with WASH infrastructure improvements as guided by the tool, can lead to better IPC practices, and may support improvements in occupational safety, QoC, global health security, and ultimately progress towards achieving Sustainable Development Goals 3 (good health and well-being) and 6 (clean water and sanitation).

60 APPLIED LIFE SCIENCES↗

Preliminary Logistics Modeling of the Integrated Wash Aid Treatment Emergency Reuse System - 19495

We employed Analysis of Mobility Platform (AMP) and GoldSim software to model the logistics of deploying materials to implement the Integrated Wash Aid Treatment Emergency Reuse System (IWATERS) in a hypothetical cesium-contamination scenario covering a four-block strip of downtown Chicago, IL. In this deployment of IWATERS, buildings were washed down via fire-hosing and contaminated wash solution was collected in the city's waste/stormwater collection system. The contaminated wash water was treated to remove Cs via ad hoc sand/clay filtration beds, and the treated wash solution was recycled during continuing decontamination operations. A detailed task timeline for the IWATERS deployment and information (or assumptions) on the availability and location of required resources for operations provided input parameters, as well as a framework, to enable the AMP and GoldSim simulations. From the decision to deploy IWATERS to the end of operations, including the completion of processing all contaminated wash water, took 49 days with decontamination teams active for 35 days and treatment bed teams active for 37 days. The modeling results showed the availability of vermiculite clay (based on data supplied by its commercial vendors/distributors) as the limiting factor for deploying treatment bed teams and, consequentially, the recycling rate of wash water and the timeline for decontamination operations. These simulations represent the first attempt at understanding the material and personnel requirements for large-scale IWATERS operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Novel insights into ascorbate retention and degradation during the washing and post-harvest storage of spinach and other salad leaves

Post-harvest treatments of pre-packaged salad leaves potentially cause l-ascorbate loss, but the mechanisms of ascorbate degradation remain incompletely understood, especially in planta . We explored the extent and pathways of ascorbate loss in variously washed and stored salad leaves. Ascorbate was assayed by 2,6-dichlorophenolindophenol titration, and pathways were monitored by 14 C-radiolabelling followed by high-voltage electrophoresis. All leaves tested showed ascorbate loss during storage: lettuce showed the greatest percentage loss, wild rocket the least. Spinach leaves were particularly prone to losing ascorbate during washing, especially with simultaneous mechanical agitation; however, washing in the presence of hypochlorite did not significantly increase ascorbate loss. In spinach, [ 14 C]oxalate was the major product of [ 14 C]ascorbate degradation, suggesting that commercial washing causes oxidative stress. This study highlights that ascorbate/dehydroascorbic acid are lost via the oxidative pathway during washing and post-harvest storage of salad leaves. Thus changes to washing procedures could potentially increase the post-harvest retention of ascorbate.

59 BASIC BIOLOGICAL SCIENCES↗

Application of Fe-doped biochar in Cr(VI) removal from washing wastewater and residual Cr(VI) immobilization in contaminated soil

High-content Cr(VI)-contaminated soils are challenging to remediate using a single remediation technique. This study combined soil washing and immobilization to remediate high-content (3440 mg kg -1 ) Cr(VI)-contaminated soil, which investigated the effects of operating time, temperature, and liquid-solid ratio (LSR) on the Cr(VI) removal efficiency of soil washing and evaluated the potential of Fe-doped biochar (FeBC) in soluble Cr(VI) removal from the washing wastewater and residual Cr(VI) immobilization in the washed soil. The Cr(VI) removal efficiency of soil washing increased with the operating time, temperature, and LSR, but still cannot remove Cr(VI) to achieve the safety content (<100 mg kg -1 ). FeBC showed satisfactory potential in both Cr(VI) removal and immobilization from wastewater and soil, in which the main mechanisms involve ion exchange, redox, and coprecipitation. These results demonstrate applying soil washing & immobilization to remediate high-content Cr(VI)-contaminated soil is a promising alternative method.

54 ENVIRONMENTAL SCIENCES↗

Characterization of the SRNL-Washed tank 51 sludge batch 9 qualification sample

Savannah River National Laboratory (SRNL) personnel have been requested to qualify the next sludge batch (Sludge Batch 9 – SB9) for processing at the Defense Waste Processing Facility (DWPF). To accomplish this task, Savannah River Remediation (SRR) sent SRNL a 3-L sample of Tank 51H slurry to be characterized, washed, and then used in a lab-scale demonstration of the DWPF flowsheet (after combining with Tank 40H sludge). SRNL has washed the Tank 51H sample per the Tank Farm washing strategy as of October 20, 2015. A part of the qualification process is extensive radionuclide and chemical characterization of the SRNL-washed Tank 51H slurry. This report documents the chemical characterization of the washed slurry; radiological characterization is in progress and will be documented in a separate report. The analytical results of this characterization are comparable to the Tank Farm projections. Therefore, it is recommended that SRNL use this washed slurry for the ongoing SB9 qualification activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗