At least 19 records

District heating utilizing waste heat of a data center: High-temperature heat pumps

Data centers are energy-intensive facilities with substantial low-grade waste heat. High-temperature heat pumps can be critical in boosting the data center’s waste heat for district heating, improving the system-level energy efficiency of data centers, and reducing CO 2 emissions in district heating. This study built thermodynamic models to assess high-temperature heat pumps with six configurations using low global warming potential refrigerants to supply heat up to 120 °C. The heat pump configurations include single-stage or two-stage cycles with advanced components, such as internal heat exchanger, economizer, flash tank, or parallel compressor. The refrigerants include R1234ze(Z), R1233ed(E), R1224yd(Z), R600, and R600a, and R245fa is used as a reference. A case study was carried out to recover the waste heat from the Frontier high-performance computing data center and provide hot water for district heating at the US Department of Energy’s Oak Ridge National Laboratory campus. The optimized performance of high-temperature heat pumps is characterized with various effectiveness of internal heat exchangers, and the operating parameters of economizer or flash tank, as well as their combination. The results show that the configurations of two-stage cycles with internal heat exchanger + flash tank and internal heat exchanger + economizer/parallel-compressor provide the highest coefficient of performance under scenarios of the maximum allowable value and a fixed value (0.3) of the internal heat exchangers’ effectiveness, respectively. R1234ze(Z) and R600a are the most promising refrigerants, considering trade-offs between the coefficient of performance and the volumetric heating capacity. The single-stage cycle with internal heat exchanger + economizer/parallel-compressor using R1234ze(Z) is recommended for utilizing Fronter’s waste heat in district heating. A one mega-watt high-temperature heat pump will reduce 33,100–33,200 metric tons of CO2 emission annually, corresponding to 85.4 %–85.6 % of equivalent CO2 emissions from natural gas boilers. Here, this study provides good guidelines for designing and deploying high-temperature heat pumps to support sustainable data centers and decarbonize district heating in the US.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Applications of thermal energy storage to process heat and waste heat recovery in the iron and steel industry

The system identified operates from the primary arc furnace evacuation system as a heat source. Energy from the fume stream is stored as sensible energy in a solid medium (packed bed). A steam-driven turbine is arranged to generate power for peak shaving. A parametric design approach is presented since the overall system design, at optimum payback is strongly dependent upon the nature of the electric pricing structure. The scope of the project was limited to consideration of available technology so that industry-wide application could be achieved by 1985. A search of the literature, coupled with interviews with representatives of major steel producers, served as the means whereby the techniques and technologies indicated for the specific site are extrapolated to the industry as a whole and to the 1985 time frame. The conclusion of the study is that by 1985, a national yearly savings of 1.9 million barrels of oil could be realized through recovery of waste heat from primary arc furnace fume gases on an industry-wide basis. Economic studies indicate that the proposed system has a plant payback time of approximately 5 years.

Katter, L. B.↗

Energy, economic, and environmental analysis of integration of thermal energy storage into district heating systems using waste heat from data centres

Data centres produce waste heat, which can be utilized in district heating systems. However, the mismatch between data centres’ heat supply and district heating systems’ heat demands limits its utilization. Further, high peak loads increase the operation cost of district heating systems. This study aimed to solve these problems by introducing thermal energy storages. A water tank and a borehole thermal energy storage system were selected as the short-term and long-term thermal energy storage, respectively. Energy, economic, and environmental indicators were introduced to evaluate different solutions. The case study was a campus district heating system in Norway. Results showed that the water tank could shave the peak load by 31% and save the annual energy cost by 5%. The payback period was lower than 15 years when the storage efficiency remained higher than 80%. However, it had no obvious benefits in terms of mismatch relieving and CO emissions reduction. In contrast, the borehole thermal energy storage increased the waste heat utilization rate to 96% and reduced the annual CO emissions by 8%. However, the payback period was more than 17 years. These results provide guidelines for the retrofit of district heating systems, where data centres’ waste heat is available.

25 ENERGY STORAGE↗

Bioelectrochemical Integration of Waste Heat Recovery, Waste-to- Energy Conversion, and Waste-to-Chemical Conversion with Industrial Gas and Chemical Manufacturing Processes

Many U.S. manufacturing facilities generate unrecovered, low-grade waste heat, and also generate or are located near organic-content waste effluents. Bioelectrochemical systems, such as microbial fuel cells and microbial electrolysis cells, provide a means to convert organic-content effluents into electric power and useful chemical products. A novel biochemical electrical system for industrial manufacturing processes uniquely integrates both waste heat recovery and waste effluent conversion, thereby significantly reducing manufacturing energy requirements. This project will enable the further development of this technology so that it can be applied across a wide variety of US manufacturing segments, including the chemical, food, pharmaceutical, refinery, and pulp and paper industries. It is conservatively estimated that adoption of this technology could provide nearly 40 TBtu/yr of energy, or more than 1% of the U.S. total industrial electricity use, while reducing CO 2 emissions by more than 6 million tons per year. Commercialization of this technology will make a significant contribution to DOE’s Industrial Technology Program goals for doubling energy efficiency and providing a more robust and competitive domestic manufacturing base.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploration of a Novel Technique for Waste Heat Recovery Through Molecular Dynamics: Influence of Wettability and Electric Field on Water and Water-Based Nanofluids

Most of the energy produced globally comes by way of a heat engine. The Carnot principle places a limit as to how thermodynamically efficient a heat engine can be. There is no heat engine that can be 100% thermodynamically efficient and as such a substantial proportion of all heat supplied to a heat engine is lost as waste heat. Waste heat therefore is a large energy source ready to be properly utilized. Herein, a novel approach for converting waste heat to electricity is discussed. It involves the use of the liquid to vapor phase change of a material dielectric (water) or electrolyte (nanofluid) in the embodiment of a capacitor for direct thermal to electrostatic energy conversion. While this method of waste heat recovery could potentially be added to the ever expanding portfolio of energy conversion techniques, a number of aspects must be addressed before it can be brought into practice. Water was seen as an ideal dielectric phase change material given its high relative permittivity ratio when in the liquid form as compared to its vapor form. However, given its short voltage holdoff time the phase change of water would need to occur rapidly. This brings up concerns of explosive boiling. Herein, molecular dynamics analysis into the explosive boiling behavior of thin water films gave more insight into how the interaction between the surface and liquid affected explosive boiling onset time. A Lennard-Jones potential with one interaction site and a Morse potential with three interaction sites between water and solid substrate were used. It was found generally that a stronger interaction between water film and substrate led to faster explosive boiling onset times but an increase in the number of interaction sites delayed explosive boiling, even at the same wettability (contact angle). Understanding changes in the density and enthalpy of vaporization of a liquid dielectric such as water in the presence of an electric field is of importance due to the electrostatic nature of the waste heat conversion method under consideration. Specifically, if both density and enthalpy of vaporization are increased, the thermodynamic efficiency of the waste heat conversion method under consideration is decreased. Electric field effects are explored herein via molecular dynamics using two water models, the TIP4P-Ew and SWM4-NDP. The SWM4-NDP model is polarizable while the TIP4P-Ew model is not, which allows for a determination of the importance of model polarizability (i.e. variation in water model dipole moment) on these two properties of water when subjected to an electric field. Herein it was found that both water models respond similarly in terms of density and vaporization enthalpy variance upon the introduction of an electric field. Comparison was also made to the pressure induced by the electric field (electrostriction pressure) by way of a density comparison and it was found that the predicted electrostriction pressure overestimates the pressure experienced by water. Water by itself has a high enthalpy of vaporization, which limits the efficiency of the newly proposed conversion method. Research both experimental and through simulation has shown that the vaporization enthalpy of nanofluids can be engineered via nanoparticle size and material selection. An avenue less explored is manipulating the enthalpy of vaporization by altering the interaction strength between the nanoparticles and the base fluid. In practice this could be achieved through the addition of coatings to the nanoparticles to alter their wettability to the base fluid. This was explored by using a Lennard-Jones potential and Morse potential to model the interaction between base fluid (water) and the nanoparticle. For nanoparticles 2nm in diameter and at weight percentages up to 6%, the change in vaporization enthalpy due to alterations of the interaction strength between nanoparticle and base fluid was not significant (less than a 1% difference) when compared to the effect of altering the weight percentage of nanoparticles in the nanofluid or introducing an electric field. However, the effect of wettability may still become important at other nanoparticle concentrations and sizes. In all, the studies presented here further the understanding of phase change and thermodynamic properties of water and water based nanofluids under an electrostatic field which will help inform the development of a novel approach to waste heat conversion. The reduction of waste heat will improve energy sustainability outlooks.

30 DIRECT ENERGY CONVERSION↗

Optimal environmental and economic performance trade-offs for fifth generation district heating and cooling network topologies with waste heat recovery

Network topology greatly influences both the economic and environmental performance of fifth generation district heating and cooling (5GDHC) systems. In this study the optimal trade-offs between the environmental and economic performance of 5GDHC network topologies for a five-building district with waste heat recovery were explored. A life cycle assessment method was used to calculate the total life cycle CO 2 emissions (LCCO2) associated with the installation and operation of various network topologies. Twelve months of empirical data from a data center cooling system were analyzed to assess its suitability for integration into a 5GDHC system. The most suitable method for utilizing this waste heat was selected based on the ambient loop warm pipe setpoint, waste heat temperature, and district energy system configuration. A multi-objective optimization algorithm was used to select the 5GDHC network topology that provided the optimal trade-off between LCCO2 and life cycle cost (LCC). A trade-off parameter was employed to weigh the importance of each objective in the selection process. The results showed waste heat from the data center was suitable for integration into the 5GDHC system due to its availability and consistent temperature profile. When return temperatures of 25 °C or higher were available from the liquid-cooled system, direct pre-heating of the ambient loop warm pipe was found to be the most effective waste heat integration method. The selection of the network topology that provided the optimal trade-off between LCCO2 and LCC (optimal trade-off topology) was highly dependent on factors such as fuel prices, CO 2 prices, electricity CO 2 emissions factors, availability of waste heat, embodied CO 2 emissions associated with network installation and network infrastructure costs. Optimal trade-off topologies produced substantial LCCO2 reductions relative to corresponding LCC increases. LCCO2 reduction to LCC increase ratios from 5.78 to 117.79 were identified with CO 2 offset costs ranging from 4.77 to 60.08 ($/tCO 2 e).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model Guidance to Address Barriers to Combined Heat and Power and Waste Heat to Power

Congress directed that the US Department of Energy (DOE) initiate a review of interconnection rules to identify barriers to interconnection and ways to better integrate combined heat and power (CHP) and waste heat to power (WHP) in the electric grid. Oak Ridge National Laboratory (ORNL) supports DOE by providing technical assistance for CHP. DOE tasked ORNL with the interconnection review and development of model guidance to enable developers and CHP owners to interconnect more CHP. This report summarizes the work that DOE initiated in response to the congressional request.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Heat Exchanger Design for Waste Heat Recovery using Additive Manufacturing

With anticipated increases in global energy use and their associated emissions, there are many efforts to improve the emissions and efficiency of many industrial processes through waste heat recovery (WHR). To maximize improvements, the heat exchangers in WHR power cycles must be designed and optimized for a given heat source. Meanwhile, additive manufacturing (AM) is a single part manufacturing technique that provides the opportunity to develop unique and complex heat exchanger designs. Consequently, this work centers on the modeling, design, optimization, and testing of AM shell and tube heat exchangers for WHR. Specifically, a modified one-dimensional (1+1-D) and three-dimensional (3-D) heat exchanger models were developed and validated, with the 1+1-D model serving as the basis for design optimization. After modifications to the design to allow for AM, heat exchanger geometry optimizations were completed, targeting increased effectiveness across a range of physical parameters. Of the designs considered, nine were additively manufactured using Ti5553, and then tested using an external heat source and working fluid. Experimentally, the nineteen-tube, zero-baffle heat exchanger displayed the best overall performance, with the effects of dimensional accuracy, surface roughness, and baffles in the other designs also indicated. Next, the experimental results were used as inputs for the 1+1-D model. Although the original model was able to predict fluid outlet temperatures within 5% differences, larger variations in the heat exchanger performance parameters, temperature differences, and pressure drop necessitated optimizing the pressure drop and heat transfer calculations within the model. Thus, the resulting improved model was able to predict the heat transfer rates, heat source temperature difference, and effectiveness within 15% differences, while showing improvements in the pressure drops and working fluid temperature differences. The improved model serves as the foundation for future work to improve the design and performance of AM heat exchangers.

Spickler, Bailey Ann↗

Waste Heat to Power Market Assessment

Waste heat to power (WHP) is the process of capturing heat discarded by an existing process and using that heat to generate electricity. In the industrial sector, waste heat streams are generated by kilns, furnaces, ovens, turbines, engines, and other equipment. In addition to processes at industrial plants, waste heat streams suitable for WHP are generated at field locations, including landfills, compressor stations, and mining sites. Waste heat streams are also produced in the residential and commercial sectors, but compared to industrial sites these waste heat streams typically have lower temperatures and much lower volumetric flow rates. The economic feasibility for WHP declines as the temperature and flow rate decline, and most WHP technologies are therefore applied in industrial markets where waste heat stream characteristics are more favorable. This report provides an assessment of the potential market for WHP in the industrial sector in the United States.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The New S-RAM Air Variable Compressor/Expander for Heat Pump and Waste Heat to Power Application

S-RAM Dynamics (S-RAM) has designed an innovative heat pump system targeted for commercial and industrial applications. This new heat pump system is more efficient than anything currently on the market and utilizes air as the refrigerant instead of hydrofluorocarbon (HFC) refrigerants, leading to lower operating costs, minimal environmental costs or concerns, and lower maintenance costs. The heat pumps will be manufactured in the United States. This project was aimed at determining the feasibility of utilizing additive manufacturing to make the heat exchanger device for the new heat pump system. ORNL and S-RAM Dynamics collaborated on determining the prototype performance and subsequently printing of the prototype using additive manufacturing. Complex heat exchanger designs were fabricated using the Arcam electron beam melting (EBM) powder bed technology using Ti-6Al-4V material. An ultrasonic welding system was utilized in order to remove the powder from the small openings of the heat exchanger. The majority of powder in the small chambers was removed, however, the amount of powder remaining in the heat exchanger was a function of geometry. Therefore, only certain geometries of heat exchangers could be fabricated. SRAM Dynamics evaluated a preliminary heat exchanger design. Although the results of the additive manufacturing of the heat exchanger were not optimum, a less complex geometry was demonstrated. A sleeve valve was used as a demonstration piece, as engine designs from S-RAM Dynamics require the engine to have a very high density. Preliminary designs of this geometry were successfully fabricated using the EBM technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Materials-to-device design of hybrid metal-polymer heat exchanger tubes for low temperature waste heat recovery

Heat exchangers for low temperature (<150 °C) waste heat recovery (WHR) are challenging due to severe constraints on materials costs, manufacturing methods, and maintenance opportunities after installation. Here, the use of polymers instead of metals, offers an avenue for cost reduction in WHR applications, provided the typical low thermal conductivity of polymers (~0.2 W m –1 K –1 ) that results in poor overall heat transfer coefficient can be overcome. Previous approaches to enhance the thermal conductivity of polymers remain problematic in terms of cost, thermal, and thermomechanical considerations. In this work, we propose a novel hybrid metal-polymer composite assembled from strips of polymer and copper. Polymer strips with metal-clad edges are wound helically and the interfaces between the strips joined to obtain a tube for a cross-flow heat exchanger. Interfaces are designed to enhance effective heat conduction across the material and increase the overall heat transfer coefficient. Through numerical simulations, we obtain metal-polymer layouts that achieve wall effective thermal conductivity ~1 W m –1 K –1 at ~23% or ~35% volume fraction of copper or aluminum, respectively. The conductivity enhancement is sufficient for typical low temperature WHR, resulting in a ~20% enhancement in the overall heat transfer coefficient compared to a similar all-polymer heat exchanger. Thermomechanical simulations revealed that the composite pipe designs can withstand >1.4 MPa internal pressure, under the normal operating conditions of the heat exchanger. Our work provides guidelines for designing macroscopic metal-polymer composites that can be adapted for specific requirements such as reduced materials costs, ease of manufacturing, and heat transfer enhancement. In conclusion, the optimized design of hybrid metal-polymer heat exchanger tubes potentially provides a scalable and cost-effective route toward harvesting waste heat from low temperature sources.

42 ENGINEERING↗

Bypass valve and coolant flow controls for optimum temperatures in waste heat recovery systems

Implementing an optimized waste heat recovery system includes calculating a temperature and a rate of change in temperature of a heat exchanger of a waste heat recovery system, and predicting a temperature and a rate of change in temperature of a material flowing through a channel of the waste heat recovery system. Upon determining the rate of change in the temperature of the material is predicted to be higher than the rate of change in the temperature of the heat exchanger, the optimized waste heat recovery system calculates a valve position and timing for the channel that is configurable for achieving a rate of material flow that is determined to produce and maintain a defined threshold temperature of the heat exchanger, and actuates the valve according to the calculated valve position and calculated timing.

42 ENGINEERING↗