Search NASA⌕ Search

SEARCH · Search NASA

Results for “WATER SATURATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

EGS rock reactions with Supercritical CO2 saturated with water and water saturated with Supercritical CO2

EGS using CO2 as a working fluid will likely involve hydro-shearing low-permeability hot rock reservoirs with a water solution. After that process, the fractures will be flushed with CO2 that is maintained under supercritical conditions (> 70 bars). Much of the injected water in the main fracture will be flushed out with the initial CO2 injection; however side fractures, micro fractures, and the lower portion of the fracture will contain connate water that will interact with the rock and the injected CO2. Dissolution/precipitation reactions in the resulting scCO2/brine/rock systems have the potential to significantly alter reservoir permeability, so it is important to understand where these precipitates form and how are they related to the evolving ‘free’ connate water in the system. To examine dissolution / precipitation behavior in such systems over time, we have conducted non-stirred batch experiments in the laboratory with pure minerals, sandstone, and basalt coupons with brine solution spiked with MnCl2 and scCO2. The coupons are exposed to liquid water saturated with scCO2 and extend above the water surface allowing the upper portion of the coupons to be exposed to scCO2 saturated with water. The coupons were subsequently analyzed using SEM to determine the location of reactions in both in and out of the liquid water. Results of these will be summarized with regard to significance for EGS with CO2 as a working fluid.

15 GEOTHERMAL ENERGY↗

Transport and Transformation of Selenium and Other Constituents of Flue‐Gas Desulfurization Wastewater in Water‐Saturated Soil Materials

Constructed wetland treatment systems are used to remove selenium (Se) from flue‐gas desulfurization (FGD) wastewater (WW). However, direct confirmation of the mechanism responsible for FGD WW Se retention in soil is lacking. A laboratory‐based soil column study was performed to develop an evidence‐based mechanism of Se retention and to study the behavior and the retention capacity of FGD WW constituents in water‐saturated soil. A deoxygenated 1:1 mixture of FGD WW and raw water was delivered to the columns bottom‐up at a flux of 1.68 cm d −1 for 100 d. Some of the columns were flushed with the raw water at the same rate for an additional 100 d. Column effluent was analyzed for constituents of concern. Results showed a complete retention of FGD WW Se in the soil materials. Boron and fluorine were partially retained; however, sulfur, sodium, and chlorine retention was poor, agreeing with field observations. The FGD WW Se was retained in soil near the inlet end of the columns, indicating its limited mobility under reduced conditions. Sequential extraction procedure revealed that retained Se was mainly sequestered as stable/residual forms. Bulk‐ and micro‐X‐ray absorption near‐edge structure spectroscopy confirmed that Se was mainly retained as reduced/stable species [Se(IV), organic Se, and Se(0)]. This study provides direct evidence for FGD WW Se retention in water‐saturated soil via the transformation of oxidized Se into reduced/stable forms. Core Ideas The mechanism of FGD wastewater Se retention in water‐saturated soil was studied. Sequential fractionation of Se, micro‐XRF, and micro‐ and bulk‐XANES were used. Behavior of FGD wastewater constituents in saturated soil was comparable to field‐scale observations. FGD wastewater Se exhibited strong retention in reduced soil. Reduced/stable species of Se governed the retention mechanism.

Galkaduwa, Madhubhashini B.↗

Ab initio thermodynamics of magnesium carbonates and hydrates in water-saturated supercritical CO2 and CO2-rich regions

ab initio thermodynamics is used to determine how free energies of magnesium carbonates and hydrates in a CO2–rich environment change with water concentration across a range of temperature and pressure relevant to geochemistry and carbon sequestration (275 K to 375 K and pCO2 of 1 to 210 bar). The methodology is based on first principles density-functional theory (DFT) calculations of the total energies and vibrational entropy of periclase, magnesite, brucite, nesquehonite, and hydromagnesite coupled to the experimental chemical potentials of CO2 and H2O. The impact of water in supercritical CO2 (scCO2), even though less than 1% at saturation, is found to have a significant impact on the stability of hydrated carbonate minerals. Hydromagnesite and nesquehonite are found to be more thermodynamically stable than periclase and brucite in water-saturated scCO2 and hence may be expected to result kinetically from carbonation of these minerals during CO2 sequestration. Under dehydrating conditions nesquehonite destabilizes rapidly, whereas hydromagnesite is much more likely to persist in a CO2-rich environment, consistent with the observations that hydromagnesite is widespread in nature and nesquehonite is relatively rare.

Chaka, Anne M.↗

Determination of water saturation using gas phase partitioning tracers and time-lapse electrical conductivity measurements

Water saturation is an important indicator of contaminant distribution and plays a governing role in contaminant transport within the vadose zone. Understanding the water saturation distribution is critical for both remediation and contaminant flux monitoring in unsaturated environments. In this work we propose and demonstrate a method of remotely determining water saturation levels using gas phase partitioning tracers and time-lapse bulk electrical conductivity measurements. The theoretical development includes the partitioning chemistry for the tracers we demonstrate (ammonia and carbon dioxide), as well as a review of the petrophysical relationship governing how these tracers influence bulk conductivity. We also investigate methods of utilizing secondary information provided by electrical conductivity breakthrough magnitudes induced by the tracers. We test the method on clean, well characterized, intermediate-scale sand columns under controlled conditions. Results demonstrate the capability to predict partitioning coefficients and accurately monitor gas breakthrough curves along the length of the column according to the corresponding electrical conductivity response, leading to accurate water saturation estimates. This work is motivated by the need to develop effective characterization and monitoring techniques for contaminated deep vadose zone environments, and provides a proof-of-concept toward uniquely characterizing and monitoring water saturation levels at the field scale and in three-dimensions using electrical resistivity tomography.

30 DIRECT ENERGY CONVERSION↗

Predicting the Occurrence of Mixed Mode Failure Associated With Hydraulic Fracturing, Part 2 Water Saturated Tests

Seven water-saturated triaxial extension experiments were conducted on four sedimentary rocks. This experimental condition was hypothesized more representative of that existing for downhole hydrofracture and thus it may improve our understanding of the phenomena. In all tests the pore pressure was 10 MPa and confirming pressure was adjusted to achieve tensile and transitional failure mode conditions. Using previous work in this LDRD for comparison, the law of effective stress is demonstrated in extension using this sample geometry. In three of the four lithologies, no apparent chemo-mechanical effect of water is apparent, and in the fourth lithology test results indicate some chemo-mechanical effect of water.

58 GEOSCIENCES↗

Effect of Initial Water Saturation on The Performance of Fracturing Fluids With and Without Polyallylamine under Simulated EGS Conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO2-reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO2, can be used as a less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO2 fracturing fluids outperformed other fluids such as water, CO2, and CO2/water in generating large fractures with less fluid consumed. The objective of this work is to study the effect of initial water saturation of rock on the performance of StimuFrac fluid in ½ foot cubic rock samples and under representative EGS pressure/temperature conditions using cyclic and constant flow rate injection strategies. The fracturing results are compared with results using different fracturing fluids in terms of controlling fracture propagation rates, fracture hydraulic conductivity, breakdown pressures and volumes of fluids required. Methods/Procedures/Process: In all tests, water was initially injected into the rock to increase the water saturation before the fracturing processes to simulate actual geothermal reservoir conditions. For the cyclic injection, one complete cycle consisted of (1) a PAA slug (or water slug) injection followed by (2) CO2 injection to initiate the fracture. In the second step of the first cycle, the pressure of CO2 is increased until a maximum pressure is reached (fracture is initiated at this moment), and then the injection of CO2 is allowed for another 30 seconds to propagate the fracture. Then, the two-step cycle of PAA followed by CO2 injection (up to 2-4 mL/min) was continued. For the constant flow rate injection strategies, the initial water saturation was increased by injecting water at 1000 psi and 200°C for three days. After that, an initial slug of water, CO2, or PAA was injected and then fracturing was initiated and propagated by injecting CO2 at a constant flow rate. Applications/Significance/Novelty: The results of this study suggest that water saturation, especially near the wellbore region, will significantly affect the fracturing fluid transmission into the rock porous media by changing the relative permeability of CO2 or water, thus affecting the fracture initiation and propagation. In this study, fracturing with cyclic injection or constant flow rate injection methods were performed using three different kinds of fluids systems. These fluids are water, CO2, or CO2 with PAA. Splitting the rock samples in half after fracturing reveals that the fracture propagation is significantly limited under these high water saturated conditions compared to dry initial conditions: The fractures propagate less than 1/3 length of the distance from the wellbore to rock surface, and in some cases no fracture is generated. This may be caused by the fact that leak-off is dominating the fracturing process and the injected fluid flow rate is not high enough to overcome the leak-off even under high flow rate injection conditions. Additionally, CO2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate pressure gradients away from the near-wellbore region.

Jian, Guoqing↗

Effect of initial water saturation on the performance of fracturing fluids with and without polyallylamine under simulated EGS conditions

Objectives/Scope: StimuFrac (US Patents 9,873,828 B2 and 9,447,315 B2), a CO 2 - reactive polymer aqueous solution [polyallylamine (PAA) 1wt% in water] combined with CO 2 , can be used as a potentially less water-intensive fracturing fluid for enhanced geothermal systems (EGS). Our previous results show that in hot dry rock (HDR), PAA/CO 2 fracturing fluids outperformed other fluids such as water, CO 2 , and CO 2 /water in generating large fractures with less fluid consumed. The objective of this work is to investigate the effect of initial water saturation on the performance of StimuFrac by conducting hydraulic fracturing tests with ½ foot cubic rock samples held under representative EGS stress/temperature conditions and by using cyclic injection strategies (under constant injection rate). The resulting fracture hydraulic conductivities, breakdown pressures, and volumes of fluids required are compared. Methods/Procedures/Process: To simulate geothermal reservoir conditions, in all tests, the rock sample was held under triaxial confinement and at 200 °C, and different volumes of water were initially injected into the rock sample before any fracturing processes were initiated. For the single-cycle PAA (or water) alternating CO 2 (PAG or WAG) injection fracturing experiments, one complete cycle consisted of two steps: (1) injecting a PAA slug (or water slug) followed by (2) injecting CO 2 to initiate and propagate the fracture. For experiments involving multiple injection cycles, the CO 2 injection pressure is increased until it peaks and begins to decline (indicating fracture initiation at this moment), and then continued being injected for another 30 seconds to propagate the fracture. Then, these two-step cycles [injection of PAA (or water) followed by CO 2 injection (up to 2-4 mL/min)] are repeated. Applications/Significance/Novelty: The results of this study suggest that water saturation significantly affects the fracturing fluid transmission into the rock pore space, thus affecting the fracture initiation and propagation. In this study, fracturing tests via a single injection cycle or multiple injection cycles were performed. Splitting the rock samples in half after testing reveals that fracture propagation is significantly limited under high water saturation conditions (three-day initial water injection) compared to stimulation experiments performed in hot dry rock. The fractures propagate less than 1/3 of the distance from the wellbore to the outer rock surface, and in some cases, no fracture is generated. This may be caused by leak-off dominating the fracturing process and the fluid injection rate is insufficient to overcome leak-off, even under high injection rate conditions. Additionally, CO 2 could be leaking off into the wellbore annulus and this may be making it more difficult to generate sufficiently high-pressure gradients away from the near-wellbore region. Under low water saturation conditions (dry rock or after 1-day initial water injection), PAA/CO 2 consistently generated significantly larger fractures compared with the other fluids. CO 2 generated large fractures only in the hot dry rock and only when using high injection rates, though data variability is high.

58 GEOSCIENCES↗

Modeling the diffusion of Na+ in compacted water-saturated Na-bentonite as a function of pore water ionic strength

Assessments of bentonite barrier performance in waste management scenarios require an accurate description of the diffusion of water and solutes through the barrier. A two-compartment macropore/nanopore model (on which smectite interlayer nanopores are treated as a distinct compartment of the overall pore space) was applied to describe the diffusion of {sup 22}Na{sup +} in compacted, water-saturated Na-bentonites and then compared with the well-known surface diffusion model. The two-compartment model successfully predicted the observed weak ionic strength dependence of the apparent diffusion coefficient (D{sub a}) of Na{sup +}, whereas the surface diffusion model did not, thus confirming previous research indicating the strong influence of interlayer nanopores on the properties of smectite clay barriers. Since bentonite mechanical properties and pore water chemistry have been described successfully with two-compartment models, the results in the present study represent an important contribution toward the construction of a comprehensive two-compartment model of compacted bentonite barriers.

54 ENVIRONMENTAL SCIENCES↗

Determination of Water Saturation in Relatively Dry Porous Media Using Gas-phase Tracer Tests

Soil desiccation (drying), involving water evaporation induced by dry air injection and extraction, is a potentially robust remediation process to slow migration of inorganic or radionuclide contaminants through the vadose zone. The application of gas-phase partitioning tracer tests has been proposed as a means to estimate initial water volumes and to monitor the progress of the desiccation process at pilot-test and field sites. In this paper, tracer tests have been conducted in porous medium columns with various water saturations using sulfur hexafluoride as the conservative tracer and tricholorofluoromethane and difluoromethane as the water-partitioning tracers. For porous media with minimal silt and/or organic matter fractions, tracer tests provided reasonable saturation estimates for saturations close to zero. However, for sediments with significant silt and/or organic matter fractions, tracer tests only provided satisfactory results when the water saturation was at least 0.1 - 0.2. For dryer conditions, the apparent tracer retardation increases due to air – soil sorption, which is not included in traditional retardation coefficients derived from advection-dispersion equations accounting only for air – water partitioning and water – soil sorption. Based on these results, gas-phase partitioning tracer tests may be used to determine initial water volumes in sediments, provided the initial water saturations are sufficiently large. However, tracer tests are not suitable for quantifying moisture content in desiccated sediments.

54 ENVIRONMENTAL SCIENCES↗

Identification of Water-Saturated Zones in a Protective Hydraulic Earthen Structure by Synchronous Electromagnetic and Seismic Sounding

Results of field experiments in synchronized investigation of the protection embankment of the tailing pond of JSC Kovdor Mining and Processing Plant by means of different wave methods of electromagnetic and seismic sounding are presented. A comparative analysis of the data is carried out by means of which boundaries of zones of different degrees of water saturation of the embankment soils may be reliably established. The ranges of velocity of the electromagnetic wave and range of values of the ratio of the velocities of the longitudinal and transverse elastic wave in the transition from dry dense soil of the embankment to moistened soil right up through water-saturated soil are determined.

42 ENGINEERING↗

In Situ Infrared Spectroscopic Study of Brucite Carbonation in Dry to Water-Saturated Supercritical Carbon Dioxide

In geologic carbon sequestration, while part of the injected carbon dioxide will dissolve into host brine, some will remain as neat to water saturated super critical CO2 (scCO2) near the well bore and at the caprock, especially in the short-term life cycle of the sequestration site. Little is known about the reactivity of minerals with scCO2 containing variable concentrations of water. In this study, we used high-pressure infrared spectroscopy to examine the carbonation of brucite (Mg(OH)2) in situ over a 24 hr reaction period with scCO2 containing water concentrations between 0% and 100% saturation, at temperatures of 35, 50, and 70 °C, and at a pressure of 100 bar. Little or no detectable carbonation was observed when brucite was reacted with neat scCO2. Higher water concentrations and higher temperatures led to greater brucite carbonation rates and larger extents of conversion to magnesium carbonate products. The only observed carbonation product at 35 °C was nesquehonite (MgCO3 • 3H2O). Mixtures of nesquehonite and magnesite (MgCO3) were detected at 50 °C, but magnesite was more prevalent with increasing water concentration. Both an amorphous hydrated magnesium carbonate solid and magnesite were detected at 70 °C, but magnesite predominated with increasing water concentration. The identity of the magnesium carbonate products appears strongly linked to magnesium water exchange kinetics through temperature and water availability effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Joint inversion of electromagnetic measurements for the determination of water saturation profiles in concrete structures

Highlights: • DC-electrical and dielectric data are combined to estimate concrete saturation degree. • A joint inversion approach of the electromagnetic measurements is proposed. • The sensitivity of the measurements to the saturation model parameters is analysed. • The new joint approach was developed and is applied to synthetic and real data. • The benefits of the joint approach over the inversion of one data type are highlighted. Water saturation profiles in concrete are essential to assess its durability and can be determined using non-destructive techniques, especially the electric and the capacitive methods. In this paper, we propose a new inversion scheme where both resistivity and permittivity measurements are inverted jointly to retrieve the saturation profile. The finite element method is used to model the measurements in 3D, the concrete having a saturation profile with depth, represented by a continuous model taking the form of a Weibull curve with four parameters. A non-linear least-squares optimization based on the Levenberg-Marquardt scheme is developed for the inversion of measurements. Results show that information gathered from both measurements enriches the reconstructed profile, leading to a more reliable estimation of saturation profiles. We believe that the joint inversion method herein developed could lead to the study of more complex phenomena, such as the coupled water-chloride ingress.

36 MATERIALS SCIENCE↗

Water Saturation Relations and Their Diffusion-Limited Equilibration in Gas Shale: Implications for Gas Flow in Unconventional Reservoirs

Large volumes of water are used for hydraulic fracturing of low permeability shale reservoirs to stimulate gas production, with most of the water remaining unrecovered and distributed in a poorly understood manner within stimulated regions. Because water partitioning into shale pores controls gas release, we measured the water saturation dependence on relative humidity (rh) and capillary pressure (P c ) for imbibition (adsorption) as well as drainage (desorption) on samples of Woodford Shale. Experiments and modeling of water vapor adsorption into shale laminae at rh = 0.31 demonstrated that long times are needed to characterize equilibrium in larger (5 mm thick) pieces of shales, and yielded effective diffusion coefficients from 9 × 10 -9 to 3 × 10 -8 m 2 s -1 , similar in magnitude to the literature values for typical low porosity and low permeability rocks. Most of the experiments, conducted at 50°C on crushed shale grains in order to facilitate rapid equilibration, showed significant saturation hysteresis, and that very large P c (~1 MPa) are required to drain the shales. These results quantify the severity of the water blocking problem, and suggest that gas production from unconventional reservoirs is largely associated with stimulated regions that have had little or no exposure to injected water. Finally, gravity drainage of water from fractures residing above horizontal wells reconciles gas production in the presence of largely unrecovered injected water, and is discussed in the broader context of unsaturated flow in fractures.

58 GEOSCIENCES↗

Study on the Impacts of Capillary Number and Initial Water Saturation on the Residual Gas Distribution by NMR

The determination of microscopic residual gas distribution is beneficial for exploiting reservoirs to their maximum potential. In this work, both forced and spontaneous imbibition (waterflooding) experiments were performed on a high-pressure displacement experimental setup, which was integrated with nuclear magnetic resonance (NMR) to reveal the impacts of capillary number ( Ca ) and initial water saturation ( S wi ) on the residual gas distribution over four magnitudes of injection rates (Q = 0.001, 0.01, 0.1 and 1 mL/min), expressed as Ca (log Ca = –8.68, –7.68, –6.68 and –5.68), and three different S wi ( S wi = 0%, 39.34% and 62.98%). The NMR amplitude is dependent on pore volumes while the NMR transverse relaxation time ( T 2 ) spectrum reflects the characteristics of pore size distribution, which is determined based on a mercury injection (MI) experiment. Using this method, the residual gas distribution was quantified by comparing the T 2 spectrum of the sample measured after imbibition with the sample fully saturated by brine before imbibition. The results showed that capillary trapping efficiency increased with increasing S wi , and above 90% of residual gas existed in pores larger than 1 μm in the spontaneous imbibition experiments. The residual gas was trapped in pores by different capillary trapping mechanisms under different Ca , leading to the difference of residual gas distribution. The flow channels were mainly composed of micropores (pore radius, r < 1 μm) and mesopores ( r = 1–10 μm) at log Ca = –8.68 and –7.68, while of mesopores and macropores (r > 10 μm) at logCa = –5.68. At both S wi = 0% and 39.34%, residual gas distribution in macropores significantly decreased while that in micropores slightly increased with log Ca increasing to –6.68 and –5.68, respectively.

02 PETROLEUM↗

Photoacoustic infrared spectroscopy for conducting gas tracer tests and measuring water saturations in landfills

Highlights: Black-Right-Pointing-Pointer Photoacoustic infrared spectroscopy tested for measuring tracer gas in landfills. Black-Right-Pointing-Pointer Measurement errors for tracer gases were 1-3% in landfill gas. Black-Right-Pointing-Pointer Background signals from landfill gas result in elevated limits of detection. Black-Right-Pointing-Pointer Technique is much less expensive and easier to use than GC. - Abstract: Gas tracer tests can be used to determine gas flow patterns within landfills, quantify volatile contaminant residence time, and measure water within refuse. While gas chromatography (GC) has been traditionally used to analyze gas tracers in refuse, photoacoustic spectroscopy (PAS) might allow real-time measurements with reduced personnel costs and greater mobility and ease of use. Laboratory and field experiments were conducted to evaluate the efficacy of PAS for conducting gas tracer tests in landfills. Two tracer gases, difluoromethane (DFM) and sulfur hexafluoride (SF{sub 6}), were measured with a commercial PAS instrument. Relative measurement errors were invariant with tracer concentration but influenced by background gas: errors were 1-3% in landfill gas but 4-5% in air. Two partitioning gas tracer tests were conducted in an aerobic landfill, and limits of detection (LODs) were 3-4 times larger for DFM with PAS versus GC due to temporal changes in background signals. While higher LODs can be compensated by injecting larger tracer mass, changes in background signals increased the uncertainty in measured water saturations by up to 25% over comparable GC methods. PAS has distinct advantages over GC with respect to personnel costs and ease of use, although for field applications GC analyses of select samples are recommended to quantify instrument interferences.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Clay hydration/dehydration in dry to water-saturated supercritical CO2: Implications for caprock integrity

Injection of supercritical CO2 (scCO2) for the geologic storage of carbon dioxide will displace formation water, and the pore space adjacent to overlying caprocks could eventually be dominated by dry to water-saturated scCO2. Wet scCO2 is highly reactive and capable of carbonating and hydrating certain minerals, whereas anhydrous scCO2 can dehydrate water-containing minerals. Because these geochemical processes affect solid volume and thus porosity and permeability, they have the potential to affect the long-term integrity of the caprock seal. In this study, we investigate the swelling and shrinkage of an expandable clay found in caprock formations, montmorillonite (Ca-STx-1), when exposed to variable water-content scCO2 at 50 °C and 90 bar using a combination of in situ probes, including X-ray diffraction (XRD), in situ magic angle spinning nuclear magnetic resonance spectroscopy (MAS NMR), and in situ attenuated total reflection infrared spectroscopy (ATR-IR). We show that the extent of montmorillonite clay swelling/shrinkage is dependent not only on water hydration/dehydration, but also on CO2 intercalation reactions. Our results also suggest a competition between water and CO2 for interlayer residency where increasing concentrations of intercalated water lead to decreasing concentrations of intercalated CO2. Overall, this paper demonstrates the types of measurements required to develop fundamental knowledge that will enhance modeling efforts and reduce risks associated with subsurface storage of CO2.

Environmental Molecular Sciences Laboratory↗