Search NASA⌕ Search

SEARCH · Search NASA

Results for “WATER TREATMENT PLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Case history advanced coatings for water treatment plant components

Components of water treatment plants (WTPs) are susceptible to corrosion from constant immersion in water. A case history of corrosion and proximity to chlorine problems and their treatment at an Army WTP is presented. Solutions included using high micro-silica restoration mortar and advanced coal tar epoxy coatings.

01 COAL, LIGNITE, AND PEAT↗

Colour and toxic characteristics of metakaolinite–hematite pigment for integrally coloured concrete, prepared from iron oxide recovered from a water treatment plant of an abandoned coal mine

A metakaolinite-hematite (KH) red pigment was prepared using an ocherous iron oxide sludge recovered from a water treatment plant of an abandoned coal mine. The KH pigment was prepared by heating the kaolinite and the iron oxide sludge at kaolinite's dehydroxylation temperature. Both the raw sludge and the KH specimen were characterised for their colour properties and toxic characteristics. The KH specimen could serve as a pigment for integrally coloured concrete and offers a potential use for the large volumes of the iron oxide sludge collected from mine water treatment plants. - Graphical abstract: A kaolinite based red pigment was prepared using an ocherous iron oxide sludge recovered from an abandoned coal mine water treatment plant. Display Omitted - Highlights: • A red pigment was prepared by heating a kaolinite and an iron oxide sludge. • The iron oxide and the pigment were characterised for their colour properties. • The red pigment can be a potential element for integrally coloured concrete.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanofiltration Treatment Options for Thermoelectric Power Plant Water Treatment Demands

Nanofiltration (NF) can effectively treat both cooling-tower water and coal-bed methane (CBM) produced waters. NF is an attractive option over conventional reverse osmosis because it requires less power and is less likely to scale. Nanofiltration could help in minimizing water consumption and maximize water usage efficiency of thermoelectric power plants. The power plants could increase the cycles of water recirculation through cooling towers and/or used treated impaired waters. The NF system effectively removed scaling components from cooling-tower recirculating water with an efficiency of > 99% for divalent ions, 78% - 95.8% for monovalent ions and almost 90% for silica and from CBM produced water with efficiency greater than 95% for most constituents including silica. In most cases the NF system worked better than predicted by the ROSA™, a manufacturer’s desalination software used to design systems and predict how well they will work. Theoretical calculations determined that the total volume of water discharged from cooling towers can be reduced by as much as 75% using the continuous NF process compared to traditional recirculating cooling-tower operation. The total volume of water needed for make up could be reduced by as much as 25%. The cost for NF of cooling-tower water is estimated to be $\$$0.50 – $\$$0.90 per per 1,000 gallons. Before the successful use of a NF system in a cooling tower with similar chemistry of this pilot study, the system and pretreatment system must be designed carefully to control scaling in NF unit. In addition, NF treatment of CBM produced water will likely require a pretreatment system to control parafilms, filming agents, iron flocs, coal fines, and biological growth.

Altman, Susan Jeanne↗

Investigating the fate of saxitoxins in biologically active water treatment plant filters

The saxitoxins are potent neurotoxins, which can be produced by freshwater cyanobacteria. This study assessed the fate of five saxitoxins variants through biologically active laboratory filters containing media sourced from the filters beds of two water treatment plants (WTPs). Decreases in the concentration of the less toxic variants coincided with increases in the concentrations of the more toxic variants through the filters containing anthracite sourced from two different WTPs. No changes in toxin concentrations were evident through parallel filters containing sand. The results strongly suggest that organisms within the biofilm of the anthracite filters possessed the ability to biotransform the saxitoxins variants, which has important implications for drinking water treatment, particularly since this has the potential to increase the toxicity of the filtered water.

01 COAL, LIGNITE, AND PEAT↗

Re-use of drinking water treatment plant (DWTP) sludge: Characterization and technological behaviour of cement mortars with atomized sludge additions

This paper aims to characterize spray-dried DWTP sludge and evaluate its possible use as an addition for the cement industry. It describes the physical, chemical and micro-structural characterization of the sludge as well as the effect of its addition to Portland cements on the hydration, water demand, setting and mechanical strength of standardized mortars. Spray drying DWTP sludge generates a readily handled powdery material whose particle size is similar to those of Portland cement. The atomized sludge contains 12-14% organic matter (mainly fatty acids), while its main mineral constituents are muscovite, quartz, calcite, dolomite and seraphinite (or clinoclor). Its amorphous material content is 35%. The mortars were made with type CEM I Portland cement mixed with 10 to 30% atomized sludge exhibited lower mechanical strength than the control cement and a decline in slump. Setting was also altered in the blended cements with respect to the control.

36 MATERIALS SCIENCE↗

γ-Fe{sub 2}O{sub 3} nanoparticles: An easily recoverable effective photo-catalyst for the degradation of rose bengal and methylene blue dyes in the waste-water treatment plant

Graphical abstract: - Highlights: • γ-Fe{sub 2}O{sub 3} NPs from a single-source precursor and characterized by XRD, TEM, UV–vis spectra. • The NPs were tested as effective photocatalyst toward degradation of RB and MB dyes. • The possible pathway of the photocatalytic decomposition process has been discussed. • The active species, OH·, was detected by TA photoluminescence probing techniques. - Abstract: γ-Fe{sub 2}O{sub 3} nanoparticles (NPs) were synthesized from a single-source precursor complex [Fe{sub 3}O(C{sub 6}H{sub 5}COO){sub 6}(H{sub 2}O){sub 3}]NO{sub 3} by a simple thermal decomposition process and have been characterized by X-ray diffraction analysis (XRD), transmission electron microscopy (TEM) and UV–vis spectroscopic techniques. The NPs were highly pure and well crystallized having hexagonal morphology with an average particle size of 35 nm. The prepared γ-Fe{sub 2}O{sub 3} (maghemite) NPs show effective photo-catalytic activity toward the degradation of rose bengal (RB) and methylene blue (MB) dyes under visible light irradiation and can easily be recoverable in the presence of magnetic field for successive re-uses. The possible photo-catalytic decomposition mechanism is discussed through the detection of hydroxyl radical (OH·) by terephthalic acid photo-luminescence probing technique.

36 MATERIALS SCIENCE↗

Environmental Risk Implications of Metals in Sludges from Waste Water Treatment Plants: The Discovery of Vast Stores of Metal-Containing Nanoparticles

Nanoparticle (NP) assessment in sludge materials, although of growing importance in eco- and biotoxicity studies, is commonly overlooked and, at best, understudied. In the present study, sewage sludge samples from across the mega-city of Shanghai, China were investigated for the first time using a sequential extraction method coupled with single particle inductively coupled plasma mass spectrometry (SP-ICP-MS) to quantify the abundance of metal-containing NPs in the extraction fractions and transmission electron microscopy to specifically identify the nanophases present. In general, most sludges observed showed high concentrations of Cr, Cu, Cd, Ni, Zn, and Pb, exceeding the maximum permitted values in the national application standard of acid soil in China. NPs in these sludges contribute little to the volume and mass but account for about half of the total particle number. Based on electron microscopy techniques, various NPs were further identified, including Ti-, Fe-, Zn-, Sn-, and Pb-containing NPs. All NPs, ignored by traditional metal risk evaluation methods, were observed at a concentration of 107 -1011 particles/g within the bioavailable fraction of metals. These results indicate the underestimate or misestimation in evaluating the environmental risks of metals based on traditional sequential extraction methods. A new approach for the environmental risk assessment of metals, including NPs, is urgently needed.

Oxides, Metals, Nanoparticles, Sludges↗

Utilizing waste heat in wastewater treatment plants for water desalination: Modeling and Multi-Objective optimization of a Multi-Effect desalination system using Decision Tree Regression and Pelican optimization algorithm

This paper examines the feasibility of using waste heat from wastewater treatment plants (WWTPs) for water desalination. A model was developed to utilize waste heat from the gensets at As Samra WWTP in Jordan, using real data and TRNSYS® software to calculate available waste heat. The desalination process was then modeled with ASPEN PLUS® software, focusing on multi-effect desalination (MED). Both series and parallel configurations for the MED system were compared. The study investigated the effects of system feeding flow rate, feeding pressure, and heat input on productivity, performance ratio, and recovery ratio. The study also introduces a novel optimization technique combining machine learning and modern optimization algorithms to maximize system productivity and performance. Initially, a decision tree regression (DTR) model is developed to establish relationships between key independent variables (flow rate, feed pressure, and heat input) and dependent variables (productivity, performance ratio, and recovery ratio). The Pelican Optimization Algorithm (POA) is then used to identify the optimal values of the independent variables for maximum productivity and performance. The results show that using a series configuration yields a system productivity of 3984.2 kg/hr, a performance ratio of 3.78, and a recovery ratio of 0.991 at a feed flow rate of 4000 kg/hr, feed pressure of 3 bars, and heat input of 719 kW. Optimal productivity (4421 kg/hr), performance ratio (3.81), and recovery ratio (0.851) are achieved at a feed flow rate of 5166 kg/hr, feed pressure of 3.2 bars, and heat input of 794 kW. In conclusion, the techno-economic assessment indicates a levelized cost of water of 1.63 USD/m 3 for parallel configurations and 1.65 USD/m 3 for series configurations, with a payback period of less than two years.

42 ENGINEERING↗

Basement Fill Model Evaluation of Maximum Radionuclide Concentrations for Initial Suite of Radionuclides. Zion Station Restoration Project

ZionSolutions is in the process of decommissioning the Zion Nuclear Power Plant in order to establish a new water treatment plant. There is some residual radioactive particles from the plant which need to be brought down to levels so an individual who receives water from the new treatment plant does not receive a radioactive dose in excess of 25 mrem/y⁻¹ as specified in 10 CFR 20 Subpart E. The objectives of this report are: (a) To present a simplified conceptual model for release from the buildings with residual subsurface structures that can be used to provide an upper bound on radionuclide concentrations in the fill material and the water in the interstitial spaces of the fill. (b) Provide maximum water concentrations and the corresponding amount of mass sorbed to the solid fill material that could occur in each building for use by ZSRP in selecting ROCs for detailed dose assessment calculations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of Maximum Radionuclide Groundwater Concentrations for Basement Fill Model. Zion Station Restoration Project

ZionSolutions is in the process of decommissioning the Zion Nuclear Power Plant in order to establish a new water treatment plant. There is some residual radioactive particles from the plant which need to be brought down to levels so an individual who receives water from the new treatment plant does not receive a radioactive dose in excess of 25 mrem/y⁻¹. The objectives of this report are: (a) To present a simplified conceptual model for release from the buildings with residual subsurface structures that can be used to provide an upper bound on contaminant concentrations in the fill material; (b) Provide maximum water concentrations and the corresponding amount of mass sorbed to the solid fill material that could occur in each building for use in dose assessment calculations; (c) Estimate the maximum concentration in a well located outside of the fill material; and (d) Perform a sensitivity analysis of key parameters.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Floating Solar at Lima's Twin Lakes Reservoir

The City of Lima, Ohio is developing a floating photovoltaic (FPV) facility on the surface of Twin Lake Reservoir, adjacent to the City’s water treatment plant. The FPV array is designed with a capacity of 2 megawatts (MW) and will consist of approximately 3,500 solar panels spanning more than four acres of water surface. Based on regional solar conditions, the system will generate 2,000 megawatt-hours (MWh) of electricity annually. While the FPV system will interconnect to the electrical infrastructure serving the water treatment plant, power produced by the system will be net-metered through the utility grid, with energy credits applied to offset the plant’s overall electrical demand rather than directly supplying all plant loads in real time.

14 SOLAR ENERGY↗

COHO - Utilizing Waste Heat and Carbon Dioxide at Power Plants for Water Treatment

The COHO is a breakthrough water purification system that can concentrate challenging feed waters using carbon dioxide and low-grade heat. For this project, we studied feeds in a lab-scale system to simulate COHO’s potential to operate at coal- powered power plants. COHO proved successful at concentrating the highly scaling and challenging wastewaters derived from a power plant’s cooling towers and flue gas desulfurization units. We also found that COHO was successful at scrubbing carbon dioxide from flue gas mixtures. Thermal regeneration of the switchable polarity solvent forward osmosis draw solution ended up requiring higher temperatures than initially anticipated, but we also found that the draw solution could be polished via reverse osmosis. A techno-economic analysis indicates that installation of a COHO at a power plant for wastewater treatment would result in significant savings.

20 FOSSIL-FUELED POWER PLANTS↗

Recovering Rare Earth Elements from Coal Mine Drainage Using Industrial Byproducts: Environmental and Economic Consequences

Coal mine drainage (CMD) impairs tens of thousands of kilometers of U.S. waterways each year, in part with the leaching of low concentrations of rare earth elements (REEs). REEs are essential for modern technologies, yet economically viable natural deposits are geospatially limited, thus engendering geopolitical concerns, and their mining is energy intense and environmentally destructive. This work summarizes laboratory-scale experimentalresults of a trap-extract-precipitate (TEP) process and uses the mass and energy balances to estimate the economic costs and environmental impacts of the TEP. The TEP process uses the alkalinity and filtering capacity of stabilized flue gas desulfurization (sFGD) material or water treatment plant (WTP) sludge to remediate CMD waters and extract REEs. Passive treatment systems that use WTP sludge are cheaper than those that use sFGD material ($\$$89,300/year or $\$$86/gT-REE vs. $\$$89,800/year or $\$$278/gT-REE) and have improved environmental performance across all indicators from two different impact assessment methods. These differences are largely attributable to the larger neutralizing capacity of WTP sludge in the treatment application.

01 COAL, LIGNITE, AND PEAT↗

Wastewater treatment plant online monitoring and control

A method of operating a waste water treatment plant (WWTP) having at least one of an aerobic digester (AD) and a membrane bioreactor (MBR) is described. The method of operating AD is comprised of monitoring and controlling AD in real-time using an online extended Kalman filter (EKF) having a online dynamic model of AD. The EKF uses real-time AD measured data, and online dynamic model of AD to update adapted model parameters and estimate model based inferred variables for AD, which are used for AD control by AD control system having supervisory and low-level control layers. The method of operating MBR is similar to that of AD. The supervisory control ensures the WWTP satisfying the effluent quality requirement while minimize the operation cost. A WWTP having at least one of AD or MBR is disclosed. The method of operating a WWTP can be implemented using a computer.

Kumar, Aditya↗

State Insights On The Water-Energy Nexus And Policy Ideas To Achieve Greater Savings

Governors, state policymakers, utilities and other stakeholders across the country are increasingly aware of the connection between energy and water production and use, and the need to conserve both resources to meet economic and environmental goals. It requires substantial amounts of water to produce energy and considerable amounts of energy to treat and deliver water. The critical interdependence between energy and water was clearly illustrated during the recent winter storm in Texas and other parts of the South in February 2021. Initial power outages contributed to a longer-term water crisis. Power outages led to water pump failures while water demand increased from frozen water pipes that burst. This caused low water pressure that can lead to harmful bacteria growth in the water. The power outages also prevented water treatment plants from properly treating the water for several days, thereby leaving many residents without clean drinking water and worsening the storm’s impacts. The National Governors Association has been working with states on this connection between water and energy and strategies for conserving those resources for several years. NGA held a Water-Energy Nexus Learning Lab in September 2020. This event invited two leading states in the water-energy nexus space, Arizona and Wisconsin, to showcase some of their model policies and programs to other states, Maryland, Nevada, North Carolina, North Dakota, and Washington, looking for greater savings opportunities. This paper provides an overview of challenges that states are facing in developing integrated water and energy conservation policies; provides background on Arizona and Wisconsin’s innovative water-energy policies and programs; and summarizes action items the participating state teams identified for their respective states. The main categories of policy solutions identified by states at NGA’s Water-Energy Nexus Learning Lab were: Funding & Financing – providing financial incentives for water efficiency modeled after established energy efficiency programs, and an emphasis on financial support for small water and energy utilities. Education & Technical Assistance – providing more education and training opportunities about ways to achieve cost-effective energy and water savings, and the needs of resource-constrained small and medium utilities for training and other assistance. Structural Changes to Encourage Conservation – developing ways to incentivize agricultural conservation such as through water allocation strategies; adopting water reuse or water loss standards; and requiring electric utilities to consider water impacts as part of their integrated resource planning process. Communications & Data – conducting energy audits, reviewing water data provided to state agencies, and developing data benchmarking tools to measure and better manage energy and water use. Climate Strategy – establishing a multi-agency working group or other collaborative approach to determine ways to integrate energy and water savings in state policies and help meet the state climate objectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Port Hope Area Initiative - Community Based Concepts Become Reality - 16538

The Port Hope Area Initiative (PHAI) involves the cleanup of historic low-level radioactive waste (LLRW) resulting from radium and uranium processing by the former Crown Corporation, Eldorado Nuclear Limited, and its predecessor companies, during the period between 1932 and 1988. The PHAI, which is based on a legal agreement between the Government of Canada and the adjacent municipalities of Port Hope and Clarington in Ontario, Canada, comprises two separate community-initiated projects for the long-term management of the historic LLRW located in each of these municipalities. The Port Hope Project involves the cleanup of approximately 1.2 million cubic metres of historic LLRW from various sites within the urban area of Port Hope, the construction and operation of an engineered aboveground mound where the waste will be safely contained, and the long-term maintenance and monitoring of the new waste management facility. The waste is currently located in 13 large-scale sites and an estimated 375 small-scale sites within the community. In contrast, the Port Granby Project involves the relocation of approximately 450,000 cubic metres of historic LLRW from the existing waste site on the north shore of Lake Ontario in rural Clarington, to a new engineered aboveground mound to be built 700 metres north of the shoreline. The work also involves the restoration of the existing site and long-term maintenance and monitoring the new facility. The PHAI entered Phase 2 (construction) of a three-phase program in early 2012, when $1.28 billion (Canadian) in federal funding was announced by the Minister of Natural Resources Canada. The funding, together with regulatory approval from the Canadian Nuclear Safety Commission (CNSC), which granted 10-year waste management licences to both projects, have permitted the PHAI to move forward with construction and remediation. Waste water treatment plants based on best-available technologies have been constructed for each project to remove a wide range of contaminants from groundwater, surface water and leachate collected during construction and operation of the aboveground mounds. Each treatment process has been designed to ensure the quality of treated water being discharged into Lake Ontario meets or exceeds stringent regulatory requirements, resulting in the enhanced protection of the Great Lakes Basin ecosystem. In 2015, the contract to build the Port Granby long-term waste management facility and remediate the existing waste site was awarded, and the long-awaited facility development will soon begin. The use of a dedicated internal waste transportation route along, which the LLRW will be trucked from the existing site to the new facility, is a key component of the design to minimize the impact on the local, rural community. In Port Hope, the removal of contaminated soil within the site for the new long-term management facility commenced in the fall of 2015. Over the next several years, multiple contracts will be awarded for construction and operation of the new waste management facility and remediation of the large and small-scale sites. In short, the Port Hope and Port Granby community-based concepts have matured into tangible projects with appropriate regulatory approvals and federal funding in place. Ongoing communications with the two communities have resulted in a well-informed public that understands the work to be done and is eager to see their projects take shape and become reality. As Canada's largest environmental remediation and restoration undertaking, the PHAI has never been closer to fulfilling its vision - working with the local communities to fulfil Canada's commitment for the cleanup of historic waste in Port Hope and Port Granby to leave an honourable legacy for future generations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study of radon concentration in wetland Mediterranean water using continuous monitoring - 25416

Radon is a radioactive gas that comes from the uranium and radium decay. It is considered the second cause of lung cancer in nonsmokers by the World Health Organization (WHO). Most studies focus on radon levels in air, which comes mainly from soil. Unfortunately, just some of them focus on radon in water which exposure is mainly due to radon inhalation when it is exhaled from water. In order to develop a methodology for radon measurement in water, this work compares two different techniques. The measurements have been done at Peniscola marsh, a location in the Valencian Community where significant radon concentrations have been measured in previous works. Furthermore, measurements in the Waste-Water-Treatment Plant (WWTP) near the marsh, where high radon concentrations have been found in air, are analyzed to confirm if they can be related to radon presence in water. (authors)

54 ENVIRONMENTAL SCIENCES↗