Search NASA⌕ Search

SEARCH · Search NASA

Results for “WAVEGUIDE RADIATOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Larmor power limit for cyclotron radiation of relativistic particles in a waveguide

Cyclotron radiation emission spectroscopy (CRES) is a modern technique for high-precision energy spectroscopy, in which the energy of a charged particle in a magnetic field is measured via the frequency of the emitted cyclotron radiation. The He6-CRES collaboration aims to use CRES to probe beyond the standard model physics at the TeV scale by performing high-resolution and low-background beta-decay spectroscopy of 6 He and 19 Ne. Having demonstrated the first observation of individual, high-energy (0.1–2.5 MeV) positrons and electrons via their cyclotron radiation, the experiment provides a novel window into the radiation of relativistic charged particles in a waveguide via the time-derivative (slope) of the cyclotron radiation frequency, df c /dt. We show that analytic predictions for the total cyclotron radiation power emitted by a charged particle in circular and rectangular waveguides are approximately consistent with the Larmor formula, each scaling with the Lorentz factor of the underlying e ± as γ 4 . This hypothesis is corroborated with experimental CRES slope data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Waveguides for neurostimulation in the cochlea

Introduction Optical stimulation has been suggested for neural stimulation to improve cochlear implants. Light allows for more spatially selective activation of neuron populations than electrical current, offering more independent frequency bands along the spiral ganglion. These bands are available to encode acoustic information with anticipated better frequency resolution, improving cochlear implant user performance in noisy listening environments, tonal languages, and music perception. Methods Optical cochlear implants (oCIs) can deliver light either directly via small emitters within the cochlea or via waveguides from external optical sources. We investigated three waveguide designs made from OrmoComp ® , a polymer that cures through ultraviolet (UV) radiation. Waveguides were fabricated via injection molding and coated using dip-coating or thermal reflow, or through aspiration of OrmoComp ® into polyimide tubing that served as the cladding of the waveguide. The choice of fabrication technique directly determined the waveguides' total diameter: thermal reflow yielded ≈940 μm, dip-coating produced ≈306 μm, and aspiration resulted in ≈132 μm core diameter waveguides. Given the human cochlea's small size, we focused on analyzing the 306-μm and 132-μm waveguides, evaluating their optical performance (propagation and bending losses) and mechanical properties (bending stiffness and insertion forces). Furthermore, we evaluated some of these designs in in-vivo guinea pigs experiments. Results For the 100-μm core diameter waveguides, the propagation losses were 12.34 ± 1.26, 1.18 ± 0.88, 1.49 ± 0.58, and 3.43 ± 0.68 dB/cm at 534, 1,375, 1,460, and 1,550 nm, respectively. The respective bending losses at a 2 mm radius of curvature were 5.50 ± 1.32, 0.56 ± 0.26, 0.79 ± 0.18, and 0.64 ± 0.23 dB, and at 1 mm 8.54 ± 1.30, 2.05 ± 0.84, 2.11 ± 0.50, and 1.44 ± 0.37 dB. The bending stiffness of a 1 mm segment of the 100-μm-diameter waveguides was 18.9 ± 2.2 N/m. Insertion forces for the 100-μm-diameter waveguides into an acrylic human-size scala tympani model were < 25 mN. For the waveguides with 306 and 940 μm total diameter, the propagation losses ranged between 0.43 and 2.40 dB/cm at 534, 680, 1,375, and 1,550 nm, between 2.19 and 3.78 dB/cm at 450 and 1,460 nm. Bending losses for 360 degrees at 1,375 nm were 5.0, 2.4, and 0.46 for a bending radius of 2.5-, 3-, and 4-mm. Discussion Our study demonstrated that the polymer OrmoComp ® is suitable for fabricating waveguides to transmit near-infrared radiation. In-vivo experiments showed optically evoked auditory responses originating from optical stimulation in the guinea pigs' first cochlear turn while radiation was delivered. Incoming experiments will focus on evaluating long-term performance of these waveguides in guinea pigs and cats. This study will be designed to provide insights into the waveguides' performance and biocompatibility over extended periods, essential for their potential clinical application in future oCIs.

Kim, Matthew↗

Behavior of the Fused Quartz Suspended Core Acoustic Waveguide Sensor in Gamma Radiation

Previously, a fused-quartz acoustic waveguide named the suspended core waveguide with tight-field confinement in a small diameter was developed and its sensing potential in harsh environment was demonstrated with the fabricated periodic acoustic fiber Bragg grating. In this paper, the acoustic sensor was exposed to around 70 Gy/h gamma radiation at room temperature for 3550 h at Oak Ridge National Laboratory. For comparisons, a thermocouple and two optical fiber Bragg gratings were tested under the same conditions. The central frequency reading of the acoustic sensor was found to encounter a relatively fast decrease of 0.5 kHz in the first 800 hours. The reading then became stable, centering at 478.5 kHz with a fluctuation of ±0.2 kHz, and responded to small environmental temperature variations less than 1.2 °C. The major effect to the fluctuation was concluded to be radiation-induced material compaction and expansion. For optical fiber Bragg gratings, the same one-directional fast change of readings in the first 500 hours were observed as well. Although the optical gratings were able to track temperature changes, they also showed continuous drifts. The survivability and consistency of the acoustic sensor under long-term gamma radiation could lead to new sensing methods in nuclear applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Electromagnetic waveguide based thermal energy extraction with emissive materials and modifications

The method presented uses thermally emissive materials for the extraction of heat through the use of electromagnetic waveguides, wherein the emissive material comprises materials which emit electromagnetic radiation due to thermal excitation, wherein the electromagnetic radiation is coupled to electromagnetic waveguides; a receiver adapted to receive the electromagnetic radiation for utilization, wherein the extracted electromagnetic radiation may propagate arbitrary distances inside the waveguides before the need for processing, for example, to maximize the temperature differential between the emissive material and that of the receiver; and the exchange of the chemical composition of some portion of the environment the apparatus is housed in. The thermal energy extraction apparatus described herein has the purpose of removing heat from a source for conversion to other forms of energy such as electricity and for thermal management applications. Wherein for heat management, the benefit of waveguides would constitute reduced interference with electronics through electromagnetic coupling.

Poole, Zsolt↗

Wideband radial line slot array antenna

An antenna includes a waveguide defined by a gap between a backplane with radial support ribs and a facesheet, a teardrop-shaped feed pin at a center of the backplane, and a foam spacer between the backplane and facesheet. An outward facing side of the facesheet includes thermal paint. The facesheet includes pairs of through-hole slots for releasing portions of a wave of radiation in the waveguide to generate a transmit-beam or to receive the receive-beam to generate the wave of radiation. The pairs may be disposed as a spiral array about a center of the facesheet. Each of the pairs may include first and second slots. A length of the second slot is oriented approximately perpendicular to a length of the first slot. Dispositions of the slots are set by a computer process. The dispositions optimize a trade-off between transmit and receive gains.

Bray, Matthew G.↗

Towards higher frequencies in a compact prebunched waveguide THz-FEL

Free-electron-lasers fill a critical gap in the space of THz-sources as they can reach high average and peak powers with spectral tunability. Using a waveguide in a THz FEL significantly increases the coupling between the relativistic electrons and electromagnetic field enabling large amounts of radiation to be generated in a single passage of electrons through the undulator. In addition to transversely confining the radiation, the dispersive properties of the waveguide critically affect the velocity and slippage of the radiation pulse which determine the central frequency and bandwidth of the generated radiation. In this paper, we characterize the spectral properties of a compact waveguide THz FEL including simultaneous lasing at two different frequencies and demonstrating tuning of the radiation wavelength in the high frequency branch by varying the beam energy and ensuring that the electrons injected into the undulator are prebunched on the scale of the resonant radiation wavelength.

Experimental particle physics↗

Leaky wave in high-power AlGaAs/InGaAs/GaAs semiconductor lasers

Lasers based on AlGaAs/InGaAs/GaAs heterostructures operating in the spectral range of 1.0 − 1.1 μm are investigated in order to optimise cladding layers. The effect of the thickness and composition of the cladding layers on the leakage of radiation from the laser waveguide is analysed. It is shown that for cladding thicknesses of 0.86 − 1.24 μm, it almost does not affect the output optical power. The effect of the crystal length and reflectivity of the laser mirrors on the leaky wave is demonstrated. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of First-Order Gratings in Silicon Photonic Waveguides

A simple thin film effective index analysis for first order gratings in Si photonic waveguides is shown to provide highly accurate results for reflected and transmitted power spectrums as long as the waveguide remains single mode and non-radiating. A cover layer can be added to the grating region of a Si photonic waveguide to increase the strength of the grating, modify transition losses from the input waveguide to the grating waveguide region, and/or modify the width of the reflectivity spectrum. For a given grating period, the peak reflection and spectral width of the reflectivity decrease as the duty cycle is decreased or increased from ~50%. For both radiating and multimode structures, the coupling between all modes, power radiated towards the superstrate (upwards), power radiated downwards (substrate) and transmitted power analyzed by Floquet-Bloch, Eigenmode Expansion and Finite Difference Time Domain methods show excellent agreement. Coupling coefficients calculated using analytic formulas are shown to be accurate only for shallow grating depths.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electro-optic sampling based characterization of broad-band high efficiency THz-FEL

Extremely high beam-to-radiation energy conversion efficiencies can be obtained in a THz FEL using a strongly tapered helical undulator at the zero-slippage resonant condition, where a circular waveguide is used to match the radiation group velocity to the electron beam longitudinal velocity. In this paper we report on the first electro-optic sampling (EOS) based measurements of the broadband THz FEL radiation pulses emitted in this regime. The THz field waveforms are reconstructed in the spatial and temporal domains using multi-shot and single-shot EOS schemes respectively. The measurements are performed varying the input electron beam energy in the undulator providing insights on the complex dynamics in a waveguide FEL.

79 ASTRONOMY AND ASTROPHYSICS↗

The influence of waveguide doping on the output characteristics of AlGaAs/GaAs lasers

The influence of doping of waveguide layers on the output characteristics of lasers based on AlGaAs/GaAs double separate-confinement heterostructures is analysed. The heterostructures with narrow and broadened waveguides are studied. Samples of laser diode bars with undoped and doped waveguide layers are experimentally fabricated and compared. It is shown that the latter type of structures with a broadened waveguide allows one to increase the output power of the laser diode bars by 10 % – 15 %, all other conditions being equal. (lasers. control of laser radiation parameters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of nonradiative carrier lifetimes in quantum well laser diodes from subthreshold characteristics

A method for determination of non-radiative carrier lifetimes in the waveguide and active regions of quantum well laser diodes is presented. This method is suitable for characterization of fully packaged devices and requires no special measurement equipment if the device structure is known. Furthermore, the proposed approach is experimentally demonstrated for several 800 nm laser diodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The real-time data processing and acquisition system for Project 8 Phase II

In Phase II of the Project 8 neutrino mass experiment, electrons from the decays of tritium or 83m Kr are detected via their ≈26 GHz cyclotron radiation while contained within a circular waveguide. The signal from a given electron is characterized as a brief chirp, lasting ≲10 ms and changing in frequency by ≲1 MHz/ms. To detect these signals, the Project 8 collaboration developed a Data Acquisition (DAQ) system tailored to the signal properties. The DAQ is responsible for simultaneously selecting up to three 100 MHz-wide frequency windows to study, detect, and trigger on likely signals from different electron kinetic energies, and for writing the relevant data to disk. Finally, we describe the Phase II DAQ system in detail and address how the system was used for data-taking operations.

Data acquisition↗

The real-time data processing and acquisition system for Project 8 Phase II

In Phase II of the Project 8 neutrino mass experiment, electrons from the decays of tritium or 83 m Kr are detected via their ≈ 26GHz cyclotron radiation while contained within a circular waveguide. The signal from a given electron is characterized as a brief chirp, lasting ≲ 10ms and changing in frequency by ≲ 1MHz/ms. To detect these signals, the Project 8 collaboration developed a Data Acquisition (DAQ) system tailored to the signal properties. The DAQ is responsible for simultaneously selecting up to three 100MHz-wide frequency windows to study, detect, and trigger on likely signals from different electron kinetic energies, and for writing the relevant data to disk. We describe the Phase II DAQ system in detail and address how the system was used for data-taking operations.

Ashtari Esfahani, A. [Washington U., Seattle; Shar↗

Non-circular optical fiber and mode shape converter and method

A class of fibers is described that have a non-circular cross section on one or both ends that can by optimized to capture the optical radiation from a laser diode or diode array and deliver the light in the same or different shape on the opposite end of the fiber. A large multimode rectangular waveguide may be provided which can accept the radiation from a high-power diode bar and transform it into a circular cross section on the opposite end, while preserving brightness.

Drachenberg, Derrek R.↗

Self-compression of laser pulses in a discrete medium

Using the discrete nonlinear Schrödinger equation, we study the laser radiation self-action dynamics in a nanostructured waveguide system. It is shown that for a laser pulse energy exceeding the critical value, the nonlinear evolution of the wave field markedly differs from the corresponding process in a continuous medium. While the pulse propagates in a discrete medium, its length decreases to values comparable to the scale of the structure and the velocity decreases to zero. The system parameters are determined at which the wave field after the laser pulse termination begins to propagate in the opposite direction in a compressed form. The process of slowing down and stopping the pulse is accompanied by strong radiation losses, so that about a third of the energy of the initial field distribution remains in the final compressed state. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compensation of residual amplitude modulation fluctuations in an optoelectronic system for laser radiation frequency stabilisation

Fluctuations of residual amplitude modulation in a scheme of laser frequency stabilisation by a Fabry – Perot cavity reduce the frequency stability of the laser systems intended for interrogating clock transitions of atoms and ions. The dependences of the residual amplitude modulation on a temperature of the waveguide-based electro-optical modulator used for modulating the radiation phase and on polarisation of the radiation are measured. The parameters are found, at which the influence of the residual amplitude modulation on the frequency stability is minimal. A system for active compensation is created, which reduces the contribution of fluctuations of residual amplitude modulation to the instability down to 2.1 × 10{sup −16}, which makes it possible to reach the thermal noise limit of a silicon cryogenic cavity. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗