Effect of high altitude on maximal working capacity.
High altitude effect on work capacity, discussing bicycle ergometer test results on physiological response of human subjects
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
High altitude effect on work capacity, discussing bicycle ergometer test results on physiological response of human subjects
Work capacity and psychoemotional condition of cosmonauts during space flights reflected by electroencephalograms, galvanocutaneous reactions, and electrooculographs
Effect of prolonged high altitude exposure on maximal work capacity in humans
Effects of hyperthermia and hypothermia on aerobic and anaerobic work capacities of men
Human compensatory responses to effects on EEG AND work capacity caused by back-chest accelerations
Maximum oxygen consumption as index of work output
The losses of aerobic power and orthostatic tolerance are significant effects of manned C) spaceflight that can negatively impact crew health and safety. Daily acceleration and aerobic training may ameliorate these effects. To determine the influence of passive intermittent +Gz acceleration (PA) training and active acceleration + interval exercise (AE) training on work 0 0 capacity and the acute (1 min) response to 70 deg head-up tilt, 6 men (X-Bar SD: age, 33 +/- 6 y; height, 178.3 +/- 4.6 cm; mass, 86.3 +/- 6.6 kg) participated in two 3-wk training protocols. It was hypothesized that PA and AE training would improve orthostatic tolerance and that the addition of aerobic conditioning, would not alter this effect.
The response of skeletal muscle to unweighting was studied in six healthy males who were subjected to four weeks of lowerlimb suspension. They performed three bouts of 30 consecutive maximal concentric knee extensions, before unloading and the day after (POST 1), 4 days after (POST 2) and 7 weeks after (REC) resumed weight-bearing. Peak torque of each contraction was recorded and work was calculated as the mean of the average peak torque for the three bouts and fatigability was measured as the decline in average peak torque over bouts. Needle biopsies were obtained from m. vastus lateralis of each limb before and at POST 1. Muscle fibre type composition and area, capillarity and the enzyme activities of citrate synthase (CS) and phosphofructokinase (PFK) were subsequently analysed. Mean average peak torque for the three bouts at POST1, POST2 and REC was reduced (P < 0.05) by 17, 13 and 7%, respectively. Fatigability was greater (P < 0.05) at POST2 than before unloading. Type I, IIA and IIB percentage, Type I and II area and capillaries per fibre of Type I and II did not change (P > 0.05) in response to unloading. The activity of CS, but not PFK, decreased (P < 0.05) after unloading. The weight-bearing limb showed no changes in the variables measured. The results of this study suggest that this human lowerlimb suspension model produces substantial impairments of work and oxidative capacity of skeletal muscle. The performance decrements are most likely induced by lack of weight-bearing.
Muscle hardness measurements in a squeezing dynamometer test are interpreted for expressions of adjustment effects of the central nervous system in rapid response to a starting signal. It is shown that preliminary muscle tension leads to the transmission of inhibiting proprioceptive impulses to the nervous system centers and that the degree of pre-working changes depends on the individual's typological personality characteristics. Concentration of attention during the pre-working adjustment is considered the primary emotional factor that controls sensorimotor performance.
Results are presented from a study to determine whether or not short-term variable intensity isotonic and intermittent high-intensity isokinetic short-duration leg exercise is effective for the maintenance of peak O2 (VO2) uptake and muscular strength and endurance, respectively, during 30 days of -6 deg head-down bed rest deconditioning. The results show no significant changes in leg peak torque, leg mean total work, arm total peak torque, or arm mean total work for members of the isotonic, isokinetic, and controls groups. Changes are observed, however, in peak VO2 levels. The results suggest that near-peak variabile intensity, isotonic leg excercise maintains peak VO2 during 30 days of bed rest, while peak intermittent, isokinetic leg excercise protocol does not.
The maximal duration of swimming by rats with a load of 3% of their body weight increased after 5 weeks of training. This time did not increase in animals receiving dexamethasone in the process of training. The blood corticosterone level of these rats with the maximal load increased less than that of animals trained without administration of dexamethasone.
Spatial perceptions as factor in human capacity for work
With the worldwide demand for refrigeration and cooling expected to triple, it is increasingly important to search for alternative energy resources to drive the refrigeration cycles with reduced electricity consumption. Recently, adsorption cooling has gained increased attention since energy reallocation in such systems is based on gas adsorption/desorption, which can be driven by waste/natural heat sources. Eco-friendly sorption-based cooling relies on the cyclic transfer of refrigerant gas from a high to low energy state by the pseudo-compression effect resulting from adsorption and desorption. The driving force for energy transfer relies on heat rather than electricity. The performance of a sorption chiller is primarily influenced by this cyclic sorption behavior, which is characterized as the working capacity of the porous sorbent. Thus increases in this working capacity directly translate to a more compact and efficient cooling system. How-ever, a lack of highly effective sorbent/refrigerant pairs lowers cooling performance, and therefore has limited applicability. To this end, synthetic metal-organic frameworks (MOFs) and covalent organic polymers (COPs) possess higher porosity and greater tunability leading to more substantial potential benefits for adsorption, compared to traditional sorbent materials. Similarly, hydrofluorocarbon refrigerants have more favorable applicability given ease of operation above atmospheric pressures due to suitable saturated vapor pressures and boiling points. For these reasons, our work focuses on an ongoing strategy to promote sorption cooling via improvements in the sorbent/refrigerant pair. Specifically, we target the interaction of hydrofluorocarbon refrigerants with MOF/COP materials at a molecular level by interpreting the host-guest chemistry and the role of framework pore topology. These molecular level differences translate to cooling performance, which is described herein. These strategies include engineering framework porosity (i.e., pore size, pore volume) by using elongated organic linkers and stereochemistry control during synthesis; manipulating the sorb-ate/sorbent interaction by introducing functional moieties or unsaturated metal centers to enhance working capacities in narrow pressure ranges; varying pore topology/morphology to impact adsorption isotherm behavior; and leveraging defective sites within the frameworks to further enhance adsorption capability. Here this atomic level understanding of sorb-ate-sorbent interactions is conducted using various in situ experimental techniques such as synchrotron-based X-ray diffraction, X-ray absorption spectroscopy, in situ Fourier transform infrared spectroscopy, and direct sorption energies determinization with calorimetry. Moreover, the experimentally studied interactions and the corresponding adsorption mechanism are corroborated by computational studies using density functional theory (DFT) and grand canonical Monte Carlo (GCMC) simulations. Using this approach, we envision the capability to engineer designed frameworks with precise molecular control to target refrigerant molecules and thereby enhance the performance of desired working pairs for sorption-based cooling.
Maintenance of rest and exercise performance are prime requirements for all astronauts during flight, not only for maintaining day-to-day productivity, but also for coping with unlikely emergencies. Indirect estimates of submaximal work capacity (oxygen uptake) made from changes in the heart rates of 27 Apollo astronauts (less than 15-day flights) indicated a reduction in work capacity (maximal oxygen uptake) of 17 to 21 percent. This percentage decrease was similar to that measured in middle-aged men after 21 to 30 days of -6 deg head-down bed-rest deconditioning without exercise training. Heart-rate changes during submaximal exercise in the nine Skylab astronauts suggested that they were better able to maintain their work capacity because of longer and more intensive in-flight exercise training. The strength of the flexor and extensor muscle groups decreased by 2 to 9 percent in the elbow and by 6 to 20 percent in the knee in the Skylab astronauts, also similar to the decreases in men undergoing 30 days of bed-rest deconditioning. Exercise protocols have been devised that result in maintenance of work capacity and muscular strength during 30 to 49 days of bed-rest deconditioning.
The purpose of this study was to determine whether performance of a single maximal bout of exercise during weightlessness within hours of return to earth would enhance recovery of aerobic fitness and physical work capacities under a 1G environment. Ten healthy men were subjected to a 10-d bedrest period in the 6-deg headdown position. A graded maximal supine cycle ergometer test was performed before and at the end of bedrest to simulate exercise during weightlessness. Following 3 h of resumption of the upright posture, a second maximal exercise test was performed on a treadmill to measure work capacity under conditions of 1G. Compared to before bedrest, peak oxygen consumption, V(O2), decreased by 8.7 percent and peak heart rate (HR) increased by 5.6 percent in the supine cycle test at the end of bedrest. However, there were no significant changes in peak V(O2) and peak HR in the upright treadmill test following bedrest. These data suggest that one bout of maximal leg exercise prior to return from 10 d of weightlessness may be adequate to restore preflight aerobic fitness and physical work capacity.
The problem of normal values of blood pressure after exercise taking into account the blood pressure at the end of the exercise test is discussed. Hypertensives showed a lower working capacity than normotensives. In normotensives, however, systolic blood pressure at the end of an exercise correlated well with the working capacity. After the endurance cure submaximal blood pressure was markedly lower in hypertensives with a striking dependence on the level of initial values. Systolic blood pressure at the end of an exercise test was not changed significantly. Most probably it is not possible to overcome this malregulation in hypertensives by endurance training alone.
Pedalling a bicycle at least ten minutes a day at 85% of maximum pulse rate, three days a week for ten weeks will produce moderate increases in overall strength and physical work capacity in college-age females. The longer the training session, up to thirty minutes per session, the greater are the increases in physical work capacity that result when college-age females are trained three days a week for ten weeks at 85% of their maximum heart rate.
Despite the long history of porous materials as adsorbates, fundamental limitations remain regarding the efficient capture and release of the gas molecules, with the working capacity of the material often overlooked. In microporous materials, the uptake is dominated by low-pressure adsorption, with much of this being at pressures below the minimum working threshold for many gas utilization processes. Thus, research has focused on several advances in porous materials, including photoresponsive organic units for light-induced switchable adsorption. This process utilizes light to trigger structural or electronic changes, alter the gas uptake, and change the working capacity. Additionally, while a relatively recent development, there is a significant body of research regarding the use of light to control gas storage performance.