Search NASASearch

SEARCH · Search NASA

Results for “Water Impact Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Representation and Impact of Water Head on Power System Planning and Operation

Representing water head information in power system model files, can provide a more realistic model of the system and thereby inform operation and planning personnel in the decision-making process. This article describes a procedure for modifying the power system model files (steady-state and dynamic) to represent water head information. Additionally, the impact of representing the water head on power system reliability studies including contingency analysis, cascading failure analysis and dynamic frequency response analysis has been investigated, using the modified power system models. This paper considers the detailed Western Electricity Coordination Council model during summer and winter conditions as the test system for the impact analysis. Results show that under reduced water head: 1) the number of critical voltage and branch flow violations increases; 2) chances of cascading failure and island formation increases; and 3) frequency nadir decreases as compared to those of the base cases where the water head information is not represented.

13 - HYDRO ENERGY

Connecting ambient toxicity testing with community-level responses of benthic macroinvertebrates in an impacted stream in East Tennessee, USA

Single-species laboratory toxicity tests are a standard tool for evaluating potential impairment of freshwater systems; however, it remains uncertain how well they reflect community-level impacts in natural environments. This study presents a multi-decadal dataset (2005-2025) pairing ambient toxicity testing with macroinvertebrate surveys along Bear Creek on the Oak Ridge Reservation (Tennessee, USA) downstream of an industrial complex to assess the ability of laboratory tests using stream water to track community-level effects. Biannual three-brood Ceriodaphnia dubia tests from 2005 to 2025 often showed reduced reproduction at select sites. Integrating water quality data showed strong positive correlations between sublethal toxicity and specific conductance. Macroinvertebrate diversity metrics, family-level occurrence, and densities were also associated with conductance and contemporaneous C. dubia responses. Laboratory-measured sublethal toxicity was a stronger indicator of macroinvertebrate change than conductance alone, although responses varied among sites and seasons. At the site with the highest diversity, densities and richness of Ephemeroptera, Plecoptera, Trichoptera (EPT) and non-EPT taxa were significantly related to C. dubia reproduction, with greater toxicity corresponding to lower diversity. At the family level, some pollution-tolerant taxa were more prevalent and at higher densities during periods of sublethal toxicity, while some sensitive families were absent or reduced. These patterns may reflect site-specific mixtures of acute and chronic stressors, with laboratory toxicity tests more effectively capturing short-term impacts. Overall, these multi-decadal observations suggest that laboratory toxicity tests can help track water-quality changes linked to shifts in aquatic community diversity, despite variable responses reflecting the complexity of dynamic stressors in this impacted freshwater system.

Stevenson, Louise [ORNL] (ORCID:0000000349679897)

Cellulose Nanofibers as Rheological Modifiers to Improve Biomass Slurry Processing and Fermentation

This study investigates the enhancement of biomass slurry processability through the addition of rheological modifiers, focusing on carboxymethyl cellulose (CMC) and TEMPO-mediated oxidized cellulose nanofibrils (TCNF). Three sets of experiments were conducted to assess the effects of these additives on slurry processing and fermentation. Initial experiments evaluated the slurry extrudability, concluding that TCNF aids extrusion similarly to CMC. Subsequent experiments explored slurry viscosity reduction mechanisms, revealing that while CMC significantly reduced the viscosity, TCNF’s impact is negligible. Additionally, TCNF performed comparably to CMC in water retention tests across different conditions, which suggests that TCNF have potential as an effective additive for maintaining slurry fluidity at high solid concentrations through enhanced water retention. Lastly, both additives were investigated to ensure that they did not impact hydrolyzed biomass fermentation. The findings suggest that TCNF’s mechanisms differ from those of traditional water-soluble polymers like CMC, offering insights into novel approaches to improve the biomass processing efficiency and subsequent fermentation.

Jamieson, Zachary

Neural Networks for Prediction of Complex Chemistry in Water Treatment Process Optimization

Water chemistry plays a critical role in the design and operation of water treatment processes. Detailed chemistry modeling tools use a combination of advanced thermodynamic models and extensive databases to predict phase equilibria and reaction phenomena. The complexity and formulation of these models preclude their direct integration in equation-oriented modeling platforms, making it difficult to use their capabilities for rigorous water treatment process optimization. Neural networks (NN) can provide a pathway for integrating the predictive capability of chemistry software into equation-oriented models and enable optimization of complex water treatment processes across a broad range of conditions and process designs. Herein, we assess how NN architecture and training data impact their accuracy and use in equation-oriented water treatment models. We generate training data using PhreeqC software and determine how data generation and sample size impact the accuracy of trained NNs. The effect of NN architecture on optimization is evaluated by optimizing hypothetical black-box desalination processes using a range of feed compositions from USGS brackish water data set, tracking the number of successful optimizations, and testing the impact of initial guess on the final solution. Our results clearly demonstrate that data generation and architecture impact NN accuracy and viability for use in equation-oriented optimization problems.

Dudchenko, Alexander V

Photoelectrode Durability in Two- versus Three-Electrode Configurations: Understanding the Impact of Circuit Configuration on Water-Splitting Stability

Device durability remains a significant challenge in photoelectrochemical (PEC) water splitting under ambient conditions. Yet, a lack of understanding of the test configuration and applied bias effects continue to hinder progress. In this study, we differentiate two-electrode (2E) and three-electrode (3E) configurations for evaluating PEC material durability, focusing particularly on their impacts on photoabsorber solid-state operating conditions. Our results underscore the fallacy of inferring 2E device stability from durability measurements performed solely in 3E configurations. Unmeasured and often misunderstood total circuit bias in 3E tests moderates material degradation, leading to the overestimation of photoelectrode stability compared to short-circuit operation. We demonstrate how the photoabsorber's operating voltage critically governs charge separation, surface stability, and degradation mechanisms during PEC operation. With these findings, we propose a standardized framework for conducting more reliable 3E durability experiments that simulate unassisted performance to help accelerate the development of robust, stable materials for solar-driven water splitting.

08 HYDROGEN

Charpy Impact Characterization of Surveillance Specimens Harvested from Palisades High Fluence A-60 Capsule

Located on the shores of Lake Michigan, the Palisades Nuclear Generating Station (PNGS) was a nuclear power plant that operated in Covert Township, Michigan. The plant had a single pressurized water reactor that produced electricity for the region. The PNGS was shut down in 2022 after more than four decades of service. The PNGS included in its surveillance program a surveillance capsule, designated A-60, containing specimens of a weld metal with nickel content of about 1.36 wt% and copper content of about 0.25 wt%. The capsule was removed from its surveillance position in early 1995 and has been resident in the spent fuel pool since that time. This capsule was irradiated to a fluence of 1.96×10 20 n/cm 2 (E>1MeV) that is equivalent for more than 150 effective full power years (EFPYs) for the US reactor pressure vessel (RPV) fleet. The material is also of special interest because of its very high nickel content and potential for development of NiMnSi (nickel-manganese-silicon) precipitates. Combination of very high fluence and very high Ni and Cu content makes the material in this capsule of great interest as benchmark for currently developing embrittlement trend curves (ETC) aiming to predict embrittlement at high fluences. Multi-year efforts by the Light Water Reactor Sustainability (LWRS) Program personnel from the Materials Research Pathway (MRP) to harvest this capsule finally succeeded in 2023. As a result, the Westinghouse Electric Company (WEC) through contract with Oak Ridge National Laboratory (ORNL) came to PNGS site, retrieved the A-60 capsule, brought it to WEC Churchill hot cell facility, opened the capsule and sent all surveillance specimens in the capsule to ORNL for future characterization by July 2023. Total of 9 tensile and 48 Charpy specimens were inventoried in the ORNL hot cells. Testing plan has been developed based on available specimens. It includes hardness, tensile, Charpy impact, Mini-CT fracture toughness testing, in-situ thermal annealing, and microstructural characterization, including Atom Probe Tomography (APT). Charpy impact testing has been completed and results are presented in this report. Moreover, negotiations with Pressurized Water Reactors Owners Group (PWROG) and Westinghouse resulted in Westinghouse donating to ORNL a piece of archive weld and base metal such that unirradiated characterization of these materials can be performed as part of this project. Comparison of measured hardening and embrittlement has been performed and data are compared to available large database.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Synthesis of Yttrium Oxide Particles for Interfacial Water Radiolysis Studies

Radiolysis of water produces hydrogen gas (H2), posing safety issues for nuclear reactors. Metal oxides can impact H2 formation when water is present on metal oxide surfaces. This presentation focuses on the development of a controllable synthesis of spherical yttrium oxide (Y2O3), that later will be tested for H2 production in water radiolysis. Y2O3 was synthesized via hydrothermal hydrolysis precipitation to form yttrium hydroxide (Y(OH)3), followed by high temperature decomposition to form Y2O3. Various synthesis conditions were tested to determine their impact on particle morphology including reaction time, cooling rate, reactant concentration, and inert atmospheres. Through short reaction times and rapid cooling rate, spherical, relatively uniform particles of 350 nm were obtained. Despite inert atmospheres, carbonate formation occurred in all particles. A calcination temperature of 800°C is necessary to remove impurities. Future work will aim to reduce carbonate formation and improve particle uniformity. The synthetic procedure will be translated to other metal ions to study their impact on interfacial radiolysis.

08 - HYDROGEN

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Mechanism-Informed Breakdown: Understanding Degradation by Controlling Voltage-Hold Patterns in Proton Exchange Membrane Water Electrolyzers

Low catalyst loadings pose challenges to performance stability in proton exchange membrane (PEM) water electrolysis over extended operation. To study the impact of degradation mechanisms and voltage loss rates, different stress tests are applied to membrane electrode assemblies. Potential cycling conditions were observed to induce higher degrees of iridium (Ir) oxide crystallization, ionomer degradation, and catalyst layer (CL) thinning, which likely contributed to higher kinetic loss rates. On the other hand, while Ir migrating into the PEM (Ir band) generally impairs performance, the interconnected and more uniform Ir band formed under a constant 2 V hold may allow for Ir at the catalyst/membrane interface to remain electronically connected and kinetically accessible, as well as indicate greater Ir site access during the applied stressor. The 2 V hold also demonstrates improved kinetic durability through a lower Tafel slope, faster polarization kinetics, and reduced charge transfer resistance. In contrast, potential cycling caused the migration of disconnected Ir agglomerates into the membrane bulk and created a steady increase in charge transfer resistance, a more dramatic decrease in capacitance (46.7% loss), and significant damage to the surrounding ionomer, indicating a decline in both the quality and quantity of active sites in the anode CL. This work underscores the distinct degradation pathways associated with load holds versus cycling, highlighting the role of catalyst-ionomer interactions in kinetic performance and long-term stability. These insights can inform operational strategies for PEM electrolyzers powered by intermittent energy sources, aiming to minimize efficiency losses over extended operation.

36 MATERIALS SCIENCE

When Do Riverine Systems “Feel the Burn”? Simulating How Burn Extent and Severity Modulate Hydrologic Controls on Biogeochemical Export

Wildfires impact terrestrial landscapes and downstream river corridors through shifts in vegetation and soil properties leading to downstream hydrologic and water quality impacts. The magnitude of these impacts depend on a complex and interconnected set of wildfire, landscape, and aquatic processes. Here, we isolate the impact of post-fire hydrologic changes on streamflow, nitrate, and dissolved organic carbon using the Soil and Water Assessment Tool (SWAT) model. We explore how responses differ across burn severity and area burned in two test basins: a humid forested basin and a semi-arid mixed land use basin. We ran 1830 wildfire simulations testing impacts of area burned, burn severity, and post-fire precipitation on streamflow, nitrate, and dissolved organic carbon. Our work suggests that area burned thresholds differ with burn severity and analyte. Additionally, post-fire transport of dissolved organic carbon was sensitive to both area burned and severity, while nitrate was primarily sensitive to area burned. Despite a muted (−9.5 to 5.7 mm yr −1 change) hydrologic response in the semi-arid basin, the model predicted large (7%–288% increase) shifts in dissolved organic carbon, suggesting that post-fire shifts in flow pathways and soil properties are key in its response. The limited shifts in nitrate responses in the simulations highlight that terrestrial post-fire transformations, rather than hydrologic changes, may control the increases in stream nitrate often observed post-fire. As wildfire regimes are shifting, improving understanding of post-fire nutrient export responses is critical to protect freshwater resources and aquatic ecosystems.

Wampler, Katherine A. [Pacific Northwest National

Redistribution of Ru in Fe 2 O 3 –Ru Nanocatalysts through an Oxidative Pretreatment Improves Reverse Water–Gas Shift Activity

We have synthesized Fe–Ru nanoparticles via a solvothermal method to create catalysts for the reverse water–gas shift reaction and demonstrated the impact of reductive and oxidative pretreatments on both catalytic performance and structure. Catalytic testing showed improved activity after exposure to O 2 at 600 °C. In contrast, the activity became lower if then exposed to H 2 at 600 °C. Environmental scanning transmission electron microscopy and scanning electron microscopy showed that exposure to O 2 at 600 °C changes the morphology and completely oxidizes Fe into Fe 2 O 3 . Exposure to H 2 at elevated temperature caused Ru coalescence at the surface of the nanoparticle, forming clusters which decreased the optimization of Ru. Reoxidation of the particles exposed to H 2 , however, caused a redistribution of Ru that appears beneficial in maximizing Ru exposure and synergy with Fe oxide, with no major changes in the morphology and oxide structure. Furthermore, our diagnostics demonstrate the complex and reversible rearrangements possible in these multicomponent particles and the benefits of oxidative pretreatment to enhance or regenerate Fe–Ru catalysts in other important catalytic reactions such as Fischer–Tropsch synthesis.

Fe−Ru nanoparticles

Effects of SRPPF ARS Effluent Variations on Magnesium Oxysulfate Solidification

A magnesium oxysulfate (MOS) grout formulation has been identified to solidify the liquid effluent from the Savannah River Plutonium Processing Facility (SRPPF) Aqueous Recovery System (ARS). The formulation uses reactive, light burnt MgO (28 wt%), anhydrous MgSO 4 (10 wt%), and dead burnt MgO (62 wt%), resulting in a grout with good mixability, acceptable density, acceptable setting times, and a leachate pH around 9.4, within the assumed Waste Isolation Pilot Plant (WIPP) brine pH range. A series of tests were then designed to observe how this formula reacted to variations in the liquid effluent. Liquid effluent temperature, the caustic pH level, concentration of NaNO 3 , and the presence of neutralization products, trace metals, and/or sodium sulfate (all potential residuals found in the effluent from upstream processing), were evaluated to see how each impacts the grout mixing time, peak temperature, setting time, presence of bleed water, leachate pH, and density. The standard mix has an average mixing time of 18 minutes, peak temperature of 100.5 °C, and set time of 60 minutes. Increasing the temperature of the liquid effluent increased the reaction rate of the mix and reduced mixing and setting times. Between 30 and 40°C the change was relatively small, raising no more than 6 °C compared to the standard mix maximum temperature. Increasing the pH of the liquid effluent had no significant impact on the mix. The addition of neutralization products and trace metals had an overall impact of decreasing the reactivity of the mix. The addition of more ions in the liquid effluent, such as an increase in the concentration of NaNO 3 and the addition of Na 2 SO 4 , generally decreased the reactivity of the mix. None of the variations to the liquid effluent hindered solidification as indicated by the lack of bleed water found on all the samples. The leachate pH values for all mixes tested did not significantly vary from the expected pH of 9.4 and none of the density values fell below 1.8 g/cm 3 . Overall, changes to the liquid effluent were found to have a minimal impact on the formulation suggesting the grout's ability to properly form despite increased temperatures and the presence of residuals typically found in the liquid effluent from the ARS.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Mineral Scaling in 3D Interfacial Solar Evaporators–A Challenge for Brine Treatment and Lithium Recovery

In this work, we analyzed the effects of mineral scaling on the performance of a 3D interfacial solar evaporator, with a focus on the cations relevant to lithium recovery from brackish water. The field has been rapidly moving toward resource recovery applications from brines with higher cation concentrations. However, the potential complications caused by common minerals in these brines other than NaCl have been largely overlooked. Therefore, in this study, we thoroughly examined the effects of two common cations (calcium and magnesium) on the long-term solar evaporation performance of a 3D graphene oxide stalk. The 3D stalk can achieve an evaporation flux as high as 17.8 kg m –2 h –1 under one-sun illumination, and accumulation of NaCl on the stalk surface has no impact. However, the presence of CaCl 2 and MgCl 2 significantly reduces the evaporative flux even in solutions lacking scale-forming anions. A close examination of scale formation during long-term evaporation experiments revealed that CaCl 2 and MgCl 2 tend to precipitate out within the stalk, thus blocking water transport through the stalk and significantly dropping the evaporation rates. These findings imply that research attention is needed to modify and optimize the internal water transport channels for 3D evaporators. Additionally, we emphasize the importance of testing realistic mixtures–including prominent divalent cations– and testing long-term operations in interfacial solar evaporation research and investigating approaches to mitigate the negative impacts of divalent cations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

An investigation on machine learning predictive accuracy improvement and uncertainty reduction using VAE-based data augmentation

The confluence of ultrafast computers with large memory, rapid progress in Machine Learning (ML) algorithms, and the availability of large datasets place multiple engineering fields at the threshold of dramatic progress. However, a unique challenge in nuclear engineering is data scarcity because experimentation on nuclear systems is usually more expensive and time-consuming than most other disciplines. One potential way to resolve the data scarcity issue is deep generative learning, which uses certain ML models to learn the underlying distribution of existing data and generate synthetic samples that resemble the real data. In this way, one can significantly expand the dataset to train more accurate predictive ML models. In this study, our objective is to evaluate the effectiveness of data augmentation using variational autoencoder (VAE)-based deep generative models. We investigated whether the data augmentation leads to improved accuracy in the predictions of a deep neural network (DNN) model trained using the augmented data. Additionally, the DNN prediction uncertainties are quantified using Bayesian Neural Networks (BNN) and conformal prediction (CP) to assess the impact on predictive uncertainty reduction. To test the proposed methodology, we used TRACE simulations of steady-state void fraction data based on the NUPEC Boiling Water Reactor Full-size Fine-mesh Bundle Test (BFBT) benchmark. Here, we found that augmenting the training dataset using VAEs has improved the DNN model’s predictive accuracy, improved the prediction confidence intervals, and reduced the prediction uncertainties.

Bayesian neural network

Data and scripts associated with “When do Riverine Systems 'Feel the Burn'? Simulating How Burn Extent and Severity Modulate Hydrologic Controls on Biogeochemical Export” (v2)

This data package is associated with the publication “When do Riverine Systems 'Feel the Burn'? Simulating How Burn Extent and Severity Modulate Hydrologic Controls on Biogeochemical Export” published in Water Resources Research (Wampler et al. 2025; preprint: https://doi.org/10.22541/essoar.174438106.63564767/v1). This study used the Soil and Water Assessment Tool (SWAT), a processed based model to explore the impacts of area burned and burn severity on streamflow, nitrate, and dissolved organic carbon (DOC) in two test basins: a semi-arid, mixed land use basin and a humid, primarily forested basin. We developed 1800 wildfire scenarios that we ran in each basin: 20 different burn extents (5 to 100% by 5%), 3 different burn severities (low, moderate, and high), and 30 different post-fire precipitation scenarios. We also ran an additional 30 scenarios associated with no wildfire for the 30 post-fire precipitation scenarios. For each scenario we were interested in the change in runoff ratio (streamflow) and average concentration and annual loads (nitrate and DOC) across the wildfire scenarios. This data package contains the data and scripts required to build SWAT models for the two test basins, create and run the wildfire scenarios, and generate the data summaries and figures used in the associated manuscript. This data package was originally published in March 2025. It was updated in January 2026 (v2; new and modified files) to include the final files after the manuscript went through reviews. See the change history section below for more details. For details on how to navigate data packages generated by this project, see https://data.ess-dive.lbl.gov/portals/PNNLRiverCorridorSFA/About.

54 ENVIRONMENTAL SCIENCES

Implementing Fuel Cladding Bonding and Assessing its Impact on Axial Gas Communication

Fuel rods irradiated in light-water reactors to burnup values above 45 MWd/kgU are subject to the formation of a chemical and mechanical bond between the fuel and cladding upon gap closure. The formation of the bond subsequently inhibits the ability of fission gases released from the fuel to flow freely to the plenum of the rod. The flowing of gases within fuel rods is referred to as axial gas communication. During transients, such as loss of coolant accidents, the bond may influence cladding deformation prior to breaking. Upon bond breakage, gases are able to more freely communicate to the lower pressure regions of the rod. The impact of bonding on gas communication and the ballooning behavior of the cladding during a loss of coolant accident is of interest to the nuclear industry in support of burnup extension for the existing light-water reactor fleet. In this report, a model to capture the effects of fuel cladding bonding in the BISON fuel performance code is presented. The theory of the model along with implementation testing is provided. A summary of a previously developed axial gas communication is given to set the stage for how the two models may be coupled together. A full-length pressurized-water reactor fuel rod demonstration is highlighted to evaluate the impact of including bonding on axial gas communication calculations using a preliminary coupling methodology. An overview of the next steps regarding the modeling of bonding, axial gas communication, and a more tightly coupled framework is also provided.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Modeling the impact of extreme weather events and future climate on the radiologically contaminated sites of Enewetak Atoll

Enewetak Atoll underwent 43 historical nuclear tests from 1948 to 1958, including the first hydrogen bomb test, resulting in a substantial nuclear material fallout contaminating the Atoll and the lagoon waters. The radionuclide fallout material deposited in lagoon sediments and land soil will remain for decades to come. With intensifying climate and extreme weather events, the possibility of redistribution of deposited radionuclide material has become a great concern. This study uses a numerical modeling approach to estimate the potential elevated radionuclide concentrations that can be distributed during storm events under current and future climates. We simulated three historical storm scenarios that are most likely to impact Atoll’s environment and remobilize the radionuclide-bound sediments. WRF-ARW was used to reconstruct these storm scenarios under current year (2015) and future year (2090) climates. Storm-induced ocean hydrodynamics conditions were generated using FVCOM. FVCOM-ICM was externally coupled to simulate the fate and transport of radionuclides. Given that the 239 Pu is the largest inventory of the lagoon and Atoll islands, the model results show the highest average 239 Pu concentration that an island may be exposed to is 3.25E-4 Bq/m 3 (becquerel per cubic meters), which is an increase of 84 times the average baseline/existing 239 Pu concentration without the storm conditions. The overall increase in 239 Pu average over all the islands of Atoll is about 20 folds relative to the baseline concentration. Despite the high relative increase ratios, the significantly low activity concentrations may not pose an immediate exposure risk. However, due to the limitations of the study and uncertainties/biases in the historical data used, further research supported by field surveys to better characterize the current contamination level may be needed to make more accurate predictions.

54 ENVIRONMENTAL SCIENCES

Semi-Dynamic Leach Testing of Densified Silicon-based Iodine Waste Forms

Iodine waste forms (IWF) require a conceptual corrosion release model (CCRM) to provide iodine (I) release rates for performance modeling nuclear waste disposal repositories. To develop a CCRM, an understanding of the corrosion mechanisms of the IWF are required along with data from consistent test methods to parameterize the model. The present study has advanced both areas by providing and assessing the corrosion resistance of IWF types based on their processing history in minor variations of semi-dynamic leach tests. The test included a series of semi-dynamic leach tests using monolithic IWFs in deionized water (leachant). Several experiments were conducted under alternate test conditions with changes to temperature, leachant replacement, leachant pH, leachant volume, masking, and surface finish to elucidate if varying these conditions impacted IWF corrosion behavior. Tests were conducted on two classes of IWFs: (1) I-bearing silver-mordenite (AgZ) materials processed by hot isostatic pressing (HIP) at different temperatures, pressures, sizes, and times; and (2) I-bearing silver-functionalized silica aerogels (SFA) processed by either HIP or spark plasma sintering (SPS). The corrosion susceptibility of AgZ samples was influenced by HIP temperature and pressure. The SPS SFAs retained I far better than HIP SFAs. Additional findings in this study include: (1) The iodine dissolution rate decreased with decreasing temperature, (2) a common ion effect may occur and slow dissolution of the host phase if the leachant is not regularly replaced, (3) pH controls the dissolution rate, and (4) the iodine dissolution rate slows with extended test time (up to 224 days). Based on this work, these parameters should thus be represented when developing a CCRM.

corrosion