Search NASA⌕ Search

SEARCH · Search NASA

Results for “Water vapor mixing ratio”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

New Examination of the Traditional Raman Lidar Technique II: Temperature Dependence Aerosol Scattering Ratio and Water Vapor Mixing Ratio Equations

In a companion paper, the temperature dependence of Raman scattering and its influence on the Raman water vapor signal and the lidar equations was examined. New forms of the lidar equation were developed to account for this temperature sensitivity. Here we use those results to derive the temperature dependent forms of the equations for the aerosol scattering ratio, aerosol backscatter coefficient, extinction to backscatter ratio and water vapor mixing ratio. Pertinent analysis examples are presented to illustrate each calculation.

Whiteman, David N.↗

Tower Water-Vapor Mixing Ratio Value-Added Product Report

The purpose of the Tower Water-Vapor Mixing Ratio (TWRMR) value-added product (VAP) is to calculate water-vapor mixing ratios at the 25-meter and 60-meter levels of the meteorological tower and also report best-estimate temperature, relative humidity, and pressure measurements at the 2-meter, 25-meter, and 60-meter levels at the Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) Central Facility. Because there are no barometric pressure sensors at the 25-meter and 60-meter levels on the tower, the hypsometric equation is used along with surface pressure values from the surface meteorological instrumentation (MET), the surface meteorological observation system (SMOS), or the temperature, humidity, wind, and pressure system (THWAPS) to derive barometric pressures at those altitudes (Ritsche 2008, 2011a, 2011b). After this is done, water-vapor mixing ratio can be calculated directly.

54 ENVIRONMENTAL SCIENCES↗

Mobile lidar system for measurement of water vapor mixing ratio and ozone number density

The Water Vapor Lidar was modified and extended to make differential absorption measurements of ozone. Water vapor measurements make use of a weak molecular scattering process known as Raman scattering. It is characterized by a shift in wavelength of the scattered beam of light relative to the incident one. Some of the energy of the incident photon is converted to vibrational or rotational energy within the molecule leaving the scattered photon shifted to a slightly longer wavelength. When performing water vapor measurements, profiles are acquired of water vapor mixing ratio from near the ground to beyond 7 km every 2 minutes. By forming a color composite image of the individual profiles, the spatial and temporal evolution of water vapor is visible with vertical resolution of 75 to 150m and temporal resolution of 2 minutes. The ozone lidar is intended for use as a cross calibration facility for other stationary ozone lidar systems. The ozone measurement employs the technique known as differential absorption. The backscattered laser radiation from two different wavelengths is measured. Successful measurements of 308 nm returns were made from 80 km with an averaging period of 6 hours. Using these data and a standard atmosphere density curve, an ozone number density profile was made which agrees very well with the standard ozone curve between 20 and 40 km.

Whiteman, D.↗

Tower Water-Vapor Mixing Ratio Value-Added Product Report

The purpose of the Tower Water-Vapor Mixing Ratio (TWRMR) value-added product (VAP) is to calculate water-vapor mixing ratio at the 25-meter and 60-meter levels of the meteorological tower at the Southern Great Plains (SGP) Central Facility.

54 ENVIRONMENTAL SCIENCES↗

Retrieval of water vapor mixing ratios from a laser-based sensor

Langley Research Center has developed a novel external path sensor which monitors water vapor along an optical path between an airplane window and reflective material on the plane's engine. An infrared tunable diode laser is wavelength modulated across a water vapor absorption line at a frequency f. The 2f and DC signals are measured by a detector mounted adjacent to the laser. The 2f/DC ratio depends on the amount of wavelength modulation, the water vapor absorption line being observed, and the temperature, pressure, and water vapor content of the atmosphere. The present work concerns efforts to quantify the contributions of these factors and to derive a method for extracting the water vapor mixing ratio from the measurements. A 3 m cell was fabricated in order to perform laboratory tests of the sensor. Measurements of 2f/DC were made for a series of pressures and modulation amplitudes. During my 1994 faculty fellowship, a computer program was created which allowed 2f/DC to be calculated for any combination of the variables which effect it. This code was used to generate 2f/DC values for the conditions measured in the laboratory. The experimental and theoretical values agreed to within a few percent. As a result, the laser modulation amplitude can now be set in the field by comparing the response of the instrument to the calculated response as a function of modulation amplitude. Once the validity of the computer code was established, it was used to investigate possible candidate absorption lines. 2f/DC values were calculated for pressures, temperatures, and water vapor mixing ratios expected to be encountered in future missions. The results have been incorporated into a database which will be used to select the best line for a particular mission. The database will also be used to select a retrieval technique. For examples under some circumstances there is little temperature dependence in 2f/DC so temperature can be neglected. In other cases, there is a dependence with temperature for a particular pressure, requiring a more complicated retrieval algorithm. Future experimental work is necessary to test agreement with the theoretical values over a range of temperatures and mixing ratios. Additionally, retrieval algorithms for forthcoming missions must be incorporated into the software package which controls the instrument.

Tucker, George F.↗

Temperature and water vapor mixing ratio profiles retrieved from the MWR

The purpose of this study was to look at the thermodynamic and microphysical evolution the atmosphere during fog events at Summit. These cases were selected due to the presence of fog during a period when additional aerosol sensors where deployed on the colocated tower.

54 ENVIRONMENTAL SCIENCES↗

TPSAS-NF1676L-11308-DND

The Lidar Atmospheric Sensing Experiment (LASE) system has operated on the NASA ER-2, P-3, and DC-8 aircraft during the past 16 years and participated in 13 field experiments. This system provides vertical profiles of water vapor mixing ratio and aerosol and cloud backscattering. A brief overview is presented on the upgrade of LASE that included refurbishment of laser diode seeding, control and data system, and zenith receiver system. These developments have enhanced the operational reliability of the system and improved its performance. The LASE system was deployed on the NASA DC-8 aircraft recently for the NASA GRIP (Genesis and Rapid Intensification Processes) field experiment, which was conducted during August and September 2010 from operational bases in Fort Lauderdale, FL and St. Croix, VI. Initial measurements from this field experiment are presented including distributions of water vapor, aerosol, and clouds. Temperature profiles from DC-8 dropsondes and nearby radiosondes are used to derive relative humidity profiles from the LASE water vapor mixing ratio profiles. Comparisons of LASE water vapor mixing ratio profiles with those measured by the new AVAPS-II dropsondes from the NASA DC-8 are also presented.

Susan A Kooi↗

Combined Mesonet and Tracker

Title: Combined Mesonet and Trackers (UNL Mobile Mesonets) Authors University of Nebraska PI: Adam Houston, UNL Professor (ahouston2@unl.edu) Mailing Address: 126 Bessey Hall P.O. Box 880340 Lincoln, NE 68588-0340 CoMeT Overview The University of Nebraska-Lincoln operates three Combined Mesonet and Tracker (CoMeTs). CoMeTs are Ford Explorers (model years 2015, 2017, and 2019) with forward-mounted suites of meteorological sensors and dual moonroofs, combining the capability of a mobile mesonet to collect near-surface observations with the capability of an unmanned aircraft systems (UAS) tracker vehicle, which enables an observer in the second row of seats to see the aircraft and maintain compliance with Federal Aviation Administration policies on UAS operation. The CoMeTs collect observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155A, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, and vehicle heading using a KVH Industries C-100 fluxgate compass (Barbieri et al. 2019). The HMP155A and 109SS-L thermistor are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). This list of sensors is also included in the CoMeT data file metadata. Manufacturer specifications for these instruments are given in Table 1 of Hanft and Houston (2018). The reported measured quantities are summarized below.CoMeT-3 was funded through an equipment allocation included in the NSF TORUS award (AGS-1824649). Instrument Description The specific sensors included on each CoMeT are summarized in the table at the end of this section. In general each CoMeT collects observations of slow temperature and humidity at ~2 m above ground level (AGL) using a Vaisala HMP155, fast temperature at ~2 m AGL using a Campbell Scientific 109SS-L thermistor, pressure at ~2.5 m AGL using a Vaisala PTB210 barometer with a Gill pressure port, wind speed and direction at ~3.25 m AGL using an R.M. Young 05103 propeller anemometer, position using a Garmin 19x HVS receiver, and vehicle heading using a KVH Industries C-100 fluxgate compass. The HMP155 and 109SS are shielded and aspirated within a U-tube (Waugh and Frederickson 2010; Houston et al. 2016). Fast temperature and corrected RH measurements (using sensors housed within the U-tube) have a time constant of 10-12 s based on data collected across a temperature and RH shock during the CLOUD-MAP 2017 calibration/validation tests on June 26, 2017. Vehicle speed was < 10 kts for this test. CoMeT-1 CoMeT-2 CoMeT-3 Slow Temperature Slow RH Vaisala HMP155A-L20-PT Part #: 22280-7 Vaisala HMP155E Part #: E1AA11A0B1A1A0A Vaisala HMP155E Part #: E1AA11A0B1A1A0A Fast temperature Campbell Scientific 109SS-L20-PT Part #: 21448-3 Campbell Scientific 109SS-L12-PW Part #: 21448-109 Campbell Scientific 109SS-L12-PW Part #: 21448-150 Pressure Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Vaisala PTB-210 Part #: A1A1B Gill Pressure Port Part #: 61002 Wind RM Young 05103-L20-PT Part #: 18435-310 RM Young 05103-L20-PW Part #: 18435-244 RM Young 05103-L20-PW Part #: 18435-244 GPS Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Garmin GPS 19x HVS (NMEA 0183) Part #: 010-01010-00 Compass KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 KVH C-100 Part #: 01-0177-15 Logger Campbell Scientific CR6-NA-XT-SW Part #: 28385-9 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Campbell Scientific CR6-WIFI-XT-SW Part #: 28385-6 Data Collection and Real-Time Processing The reported measured quantities are summarized in the table below. Quantity Units Source Epoch time Seconds GPS Latitude and longitude Degrees GPS Altitude m GPS Pressure hPa PTB210 Temperature (fast) deg C 109SS-L Temperature (slow) deg C HMP155 RH (slow) % HMP155 Vehicle speed m/s GPS Vehicle heading deg C-100 and GPS In addition to the measured variables, several derived variables are calculated. Corrected/fast relative humidity (%) Relative humidity is adjusted to the fast temperature following Richardson et al. (1998) and Houston et al. (2016). Water vapor mixing ratio (g/kg) Dew point temperature (&deg;C) Potential temperature (Kelvin) Virtual potential temperature (Kelvin) Equivalent potential temperature (Kelvin) Regular intercomparisons between all three CoMeTs were performed during TORUS 2019. Comparisons were also conducted between CoMeT-1 and CoMeT-2 during LAPSE-RATE (2018) on 14 July. In these intercomparisons, the vehicles were parked adjacent to each other aligned perpendicular to (and facing into) the wind. To minimize engine heating effects, intercomparisons were only conducted when the wind speed was >10 kts. Data Format Original data files for each deployment are saved as text files and then converted to NetCDF. NetCDF versions have units that are CF compliant and may not match the original units in the txt files. The naming convention for the NetCDF files is as follows: UNL.CoMeT3.{deployment date YYYYMMDD}.{start time of observation collection in UTC HHMM}.L2.{post-processing codes}.cdf example: UNL.CoMeT3.20190627.1931.L2.g1.f1.cdf Post-processing codes are included to track modifications to the raw data. These codes are closely connected to error flags associated with each record. Each letter corresponds to a particular instrument: g: GPS p: Barometer tf: Fast temperature ts: Slow temperature rh: Relative humidity f: Compass w: Wind monitor a: All instruments Each number corresponds to a particular post-processing action described more below. Measured and derived variables are included in the following table. Variable Heading Standard Name Units time Time seconds since 00:00:00, 01-01-1970 Alt Altitude meters lat Latitude degrees north lon Longitude degrees east fast_temp Air Temperature kelvin slow_temp Air Temperature kelvin pressure Air Pressure pascals logger_RH Relative Humidity percent calc_corr_RH Relative Humidity percent wind_speed Wind Speed meters per second wind_dir Wind From Direction degrees vehicle_dir Vehicle Direction degrees dewpoint Dew Point Temperature kelvin mixing_ratio Humidity Mixing Ratio g/g theta Air Potential Temperature kelvin theta_v Virtual Potential Temperature kelvin theta_e Equivalent Potential Temperature Kelvin error_flag The error_flag variable is a string that matches the post-processing codes listed above. All instruments will have an associated code, but will have a &ldquo;0&rdquo; if the datum is unchanged from the initial processed value. Error Codes The following table summarizes the error codes for data collected before 2020: Error Code Relevant CoMeT Description g1 1,2,3 Exact correction. GPS position and time reprocessed from raw data g2 1 As far as we can tell this is an exact correction to an error in the GPS time. During the correct time periods the time suddenly went backwards ~250s and stayed at this offset for 750s when it corrected itself. The offset was applied to the &ldquo;time warp&rdquo; period. p1 2 Approximate correction. Hole in the pressure tube connecting the pressure port to the barometer. Resulted in erroneously low air pressure measurements when the vehicle was in motion. Derived variables recalculated (dew point temperature [e depends on qv and p], water vapor mixing ratio, potential temperature, virtual potential temperature, equivalent potential temperature) a1 3 Exact correction. Missing data reprocessed from raw data a2 1 Bug fix to bias correction for ts1, ts2, and rh1: water vapor mixing ratio was off by a factor of 10 and virtual potential temperature was wrong because of this. f1 3 No correction, missing data. Fluxgate compass inoperable. Wind speed and direction calculated using GPS-derived vehicle heading instead. rh1 1 Approximate correction. Constant bias of +1.7% removed from relative humidity. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts1 1 Approximate correction. Constant bias of +0.6 K removed from slow temperature. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) ts2 1 Approximate correction. Constant bias of +1.0 K removed. Derived variables recalculated (corrected/fast relative humidity, dew point temperature, water vapor mixing ratio, virtual potential temperature, equivalent potential temperature) References Bolton, D., 1980: The Computation of Equivalent Potential Temperature. Mon. Wea. Rev., 108, 1046&ndash;1053, https://doi.org/10.1175/1520-0493(1980)108<1046:TCOEPT>2.0.CO;2. Hanft, W., and A. L. Houston, 2018: An Observational and Modeling Study of Mesoscale Air Masses with High Theta-E. Mon. Wea. Rev., 146, 2503&ndash;2524, https://doi.org/10.1175/MWR-D-17-0389.1.Wexler Houston, A. L., R. J. Laurence III, T. W. Nichols, S. Waugh, B. Argrow, and C. L. Ziegler, 2016: Intercomparison of unmanned aircraft-borne and mobile mesonet atmospheric sensors. Journal of Atmospheric and Oceanic Technology. 33, 1569-1582, doi: 10.1175/JTECH-D-15-0178.1. Lowe, P. R., 1977: An Approximating Polynomial for the Computation of Saturation Vapor Pressure. J. Applied Meteorology, 16, 100&ndash;103. Richardson, S. J., S. E. Frederickson, F. V. Brock, and J. A. Brotzge, 1998: Combination temperature and relative humidity probes: Avoiding large air temperature errors and associated relative humidity errors. Preprints, 10th Symp. On Meteorological Observations and Instrumentation, Phoenix, AZ, Amer. Meteor. Soc., 278&ndash;283. Waugh, S., and S. E. Frederickson, 2010: An improved aspirated temperature system for mobile meteorological observations, especially in severe weather. 25th Conf. on Severe Local Storms, Denver, CO, Amer. Meteor. Soc., P5.2. [Available online at https://ams.confex.com/ams/25SLS/techprogram/paper_176205.htm.]

54 ENVIRONMENTAL SCIENCES↗

Advances in Raman Lidar Measurements of Water Vapor, Cirrus Clouds and Carbon Dioxide

Narrow-band interference filters with improved transmission in the ultraviolet have been developed under NASA-funded research and used in the Raman Airborne Spectroscopic Lidar (RASL) in ground- based, upward-looking tests. RASL is an airborne Raman Lidar system designed to measure water vapor mixing ratio, and aerosol backscatter/extinction/depolarization. It also possesses the capability to make experimental measurements of cloud liquid water and carbon dioxide. It is being prepared for first flight tests during the summer of 2006. With the newly developed filters installed in RASL, measurements were made of atmospheric water vapor, cirrus cloud optical properties and carbon dioxide that improve upon any previously demonstrated using Raman lidar. Daytime boundary layer profiling of water vapor mixing ratio is performed with less than 5% random error using temporal and spatial resolution of 2-minutes and 60 - 210, respectively. Daytime cirrus cloud optical depth and extinction- to-backscatter ratio measurements are made using 1-minute average. Sufficient signal strength is demonstrated to permit the simultaneous profiling of carbon dioxide and water vapor mixing ratio into the free troposphere during the nighttime. Downward-looking from an airborne RASL should possess the same measurement statistics with approximately a factor of 5 - 10 decrease in averaging time. A description of the technology improvements are provided followed by examples of the improved Raman lidar measurements.

Whiteman, David N.↗

LASE validation experiment: preliminary processing of relative humidity from LASE derived water vapor in the middle to upper troposphere

Lidar Atmospheric Sensing Experiment (LASE) is the first fully engineered, autonomous airborne DIAL (Differentials Absorption Lidar) system to measure water vapor, aerosols, and clouds throughout the troposphere. This system uses a double-pulsed Ti:sapphire laser, which is pumped by a frequency-doubled flashlamp-pumped Nd: YAG laser, to transmit light in the 815 mn absorption band of water vapor. LASE operates by locking to a strong water vapor line and electronically tuning to any spectral position on the absorption line to choose the suitable absorption cross-section for optimum measurements over a range of concentrations in the atmosphere. During the LASE Validation Experiment, which was conducted over Wallops Island during September, 1995, LASE operated on either the strong water line for measurements in middle to upper troposphere, or on the weak water line for measurements made in the middle to lower troposphere including the boundary layer. Comparisons with water vapor measurements made by airborne dew point and frost point hygrometers, NASA/GSFC (Goddard Space Flight Center) Raman Lidar, and radiosondes showed the LASE water vapor mixing ratio measurements to have an accuracy of better than 6% or 0.01 g/kg, whichever is larger, throughout the troposphere. In addition to measuring water vapor mixing ratio profiles, LASE simultaneously measures aerosol backscattering profiles at the off-line wavelength near 815 nm from which atmospheric scattering ratio (ASR) profiles are calculated. ASR is defined as the ratio of total (aerosol + molecular) atmospheric scattering to molecular scattering. Assuming a region with very low aerosol loading can be identified, such as that typically found just below the tropopause, then the ASR can be determined. The ASR profiles are calculated by normalizing the scattering in the region containing enhanced aerosols to the expected scattering by the "clean" atmosphere at that altitude. Images of the total ASR clearly depict cloud regions, including multiple cloud layers, thin upper level cirrus, etc., throughout the troposphere. New data products that are being derived from the LASE aerosol and water measurements include: 1) aerosol extinction coefficient, 2) aerosol optical thickness, 3) precipitable water vapor, and 4) relative humidity (RH). These products can be compared with airborne in-situ, and ground and satellite remote sensing measurements,. This paper presents a preliminary examination of RH profiles in the middle to upper troposphere that are generated from LASE measured water vapor mixing ratio profiles coupled with rawinsonde profiles of temperature and pressure.

Brackett, Vincent G.↗

NIR-Driven Moist Upper Atmospheres of Synchronously Rotating Temperate Terrestrial Exoplanets

H2O is a key molecule in characterizing atmospheres of temperate terrestrial planets, and observations of transmission spectra are expected to play a primary role in detecting its signatures in the near future. The detectability of H2O absorption features in transmission spectra depends on the abundance of water vapor in the upper part of the atmosphere. We study the three-dimensional distribution of atmospheric H2O for synchronously rotating Earth-sized aquaplanets using the general circulation model (GCM) ROCKE-3D, and examine the effects of total incident flux and stellar spectral type. We observe a more gentle increase of the water vapor mixing ratio in response to increased incident flux than one-dimensional models suggest, in qualitative agreement with the climate-stabilizing effect of clouds around the substellar point previously observed in GCMs applied to synchronously rotating planets. However, the water vapor mixing ratio in the upper atmosphere starts to increase while the surface temperature is still moderate. This is explained by the circulation in the upper atmosphere being driven by the radiative heating due to absorption by water vapor and cloud particles, causing efficient vertical transport of water vapor. Consistently, the water vapor mixing ratio is found to be well-correlated with the near-infrared portion of the incident flux. We also simulate transmission spectra based on the GCM outputs, and show that for the more highly irradiated planets, the H2O signatures may be strengthened by a factor of a few, loosening the observational demands for a H2O detection.

Fujii, Yuka↗

Raman Lidar Profiling of Aerosols Over the Central US; Diurnal Variability and Comparisons with the GOCART Model

We use profiles of aerosol extinction, water vapor mixing ratio, and relative humidity measured by the ARM SGP Raman lidar in northern Oklahoma to show how the vertical distributions of aerosol extinction and water vapor vary throughout the diurnal cycle. While significant (20-30%) variations in aerosol extinction occurred near the surface as well as aloft, smaller (approximately 10%) variations were observed in the diurnal variability of aerosol optical thickness (AOT). The diurnal variations in aerosol extinction profiles are well correlated with corresponding variations in the average relative humidity profiles. The water vapor mixing ratio profiles and integrated water vapor amounts generally show less diurnal variability. The Raman lidar profiles are also used to evaluate the aerosol optical thickness and aerosol extinction profiles simulated by the GOCART global aerosol model. Initial comparisons show that the AOT simulated by GOCART was in closer agreement with the AOT derived from the Raman lidar and Sun photometer measurements during November 2000 than during September 2000. For both months, the vertical variability in average aerosol extinction profiles simulated by GOCART is less than the variability in the corresponding Raman lidar profiles.

Ferrare, R. A.↗

The Observed Relationship Between Water Vapor and Ozone in the Tropical Tropopause Saturation Layer and the Influence of Meridional Transport

We examine balloonsonde observations of water vapor and ozone from three Ticosonde campaigns over San Jose, Costa Rica [10 N, 84 W] during northern summer and a fourth during northern winter. The data from the summer campaigns show that the uppermost portion of the tropical tropopause layer between 360 and 380 K, which we term the tropopause saturation layer or TSL, is characterized by water vapor mixing ratios from proximately 3 to 15 ppmv and ozone from approximately 50 ppbv to 250 ppbv. In contrast, the atmospheric water vapor tape recorder at 380 K and above displays a more restricted 4-7 ppmv range in water vapor mixing ratio. From this perspective, most of the parcels in the TSL fall into two classes - those that need only additional radiative heating to rise into the tape recorder and those requiring some combination of additional dehydration and mixing with drier air. A substantial fraction of the latter class have ozone mixing ratios greater than 150 ppbv, and with water vapor greater than 7 ppmv this air may well have been transported into the tropics from the middle latitudes in conjunction with high-amplitude equatorial waves. We examine this possibility with both trajectory analysis and transport diagnostics based on HIRDLS ozone data. We apply the same approach to study the winter season. Here a very different regime obtains as the ozone-water vapor scatter diagram of the sonde data shows the stratosphere and troposphere to be clearly demarcated with little evidence of mixing in of middle latitude air parcels.

Selkirk, Henry B.↗

Dryline on 22 May 2002 During IHOP: Convective Scale Measurements at the Profiling Site

A unique set of measurements of wind, water vapor mixing ratio and boundary layer height variability was observed during the first MOP dryline mission of 22 May 2002. Water vapor mixing ratio from the Scanning Raman Lidar (SRL), high-resolution profiles of aerosol backscatter from the HARLIE and wind profiles from the GLOW are combined with the vertical velocity derived from the NCAR/ISS/MAPR and the high-resolution FMCW radar to reveal the convective variability of the cumulus cloud-topped boundary layer. A combined analysis of the in-situ and remote sensing data from aircraft, radiosonde, lidars, and radars reveals moisture variability within boundary layer updraft and downdraft regions as well as characterizes the boundary layer height variability in the dry and moist sides of the dryline. The profiler site measurements will be tied to aircraft data to reveal the relative intensity and location of these updrafts to the dry line. This study provides unprecedented high temporal and spatial resolution measurements of wind, moisture and backscatter within a dryline and the associated convective boundary layer.

Demoz, Belay↗