Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wave setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Wave Setup at the Minamitorishima Tide Gauge

A tide gauge situated on the western shore of Minamitorishima, a small atoll in the western Pacific, has measured sea levels significantly impacted by wave setup. Evidence for this rests with (a) strong correlations between sea level anomalies and high swell and (b) sea-level differences with satellite altimetry that display near-linear dependence on offshore swell heights (regression coefficient 30 cm per meter of swell). Setup is primarily induced by swell from the northwest. We develop models of wave setup which lead to corrected sea levels better reflecting the surrounding ocean, and thus more readily useful to studies of regional sea level and practical applications such as altimetry calibration. The wave setup is also evidently affecting measurements of the tide, with suppressed tide amplitudes in winter when swell is generally largest. In February 2020 the tide gauge was relocated to the southern shore of the island, and the wave setup is now markedly reduced.

Wave setup↗

Benchmarking the Integration of WAVEWATCH III Results into HAZUS-MH: Preliminary Results

The report summarizes the results from the preliminary benchmarking activities associated with the use of WAVEWATCH III (WW3) results in the HAZUS-MH MR1 flood module. Project partner Applied Research Associates (ARA) is integrating the WW3 model into HAZUS. The current version of HAZUS-MH predicts loss estimates from hurricane-related coastal flooding by using values of surge only. Using WW3, wave setup can be included with surge. Loss estimates resulting from the use of surge-only and surge-plus-wave-setup were compared. This benchmarking study is preliminary because the HAZUS-MH MR1 flood module was under development at the time of the study. In addition, WW3 is not scheduled to be fully integrated with HAZUS-MH and available for public release until 2008.

Berglund, Judith↗

Evaluation Marcelling in Composites using Ultrasonic Guided Wave

Thermoplastic composite (TPC) material seldom manifests in-plane fiber waviness during manufacturing. In-plane fiber waviness is called marcelling. Marcelling com-promises the composite strength and performance. When present in a structure, marcelling is not only a surface defect but can extend partially along the thickness of the composite. There is no established nondestructive evaluation (NDE) method to detect and quantify marcelling in composite. Ultrasonic guided waves can saturate the complete thickness of a composite structure. Thus, physics of guided wave creates an opportunity to detect and quantify the marcelling in composites. Before guided waves could be used to detect marcelling, it is necessary to quantify the marcelling in the structure and identify the marcelling affected zones (MAZE). In this research first, high frequency scanning acoustic microscopy (SAM) was performed to quantify the marcelling and statistical distribution of the defects at different MAZE was obtained. Next the MAZE with known statistical distribution of quantified marcelling (marcelling wavelength and marcelling amplitude) was inspected using ultrasonic guided wave setup. The method quantified the guided wave feature as a function of quantitative degree of marcelling. The overarching objective of this research is to implement post process NDE inspection of TPC large structures where in plane fiber waviness or marcelling can be detected and MAZEs could be identified. Primary fining is that the reduction of wave velocity and amplitude of ultrasonic guided wave could be good indicators of MAZE. However, more rigorous calibration is necessary where inspection direction is carefully devised with respect to the marcelling.

HiCAM↗

Forcing Factors Affecting Sea Level Changes at the Coast

We review the characteristics of sea level variability at the coast focussing on how it differs from the variability in the nearby deep ocean. Sea level variability occurs on all timescales, with processes at higher frequencies tending to have a larger magnitude at the coast due to resonance and other dynamics. In the case of some processes, such as the tides, the presence of the coast and the shallow waters of the shelves results in the processes being considerably more complex than offshore. However, ‘coastal variability’ should not always be considered as ‘short spatial scale variability’ but can be the result of signals transmitted along the coast from 1000s km away. Fortunately, thanks to tide gauges being necessarily located at the coast, many aspects of coastal sea level variability can be claimed to be better understood than those in the deep ocean. Nevertheless, certain aspects of coastal variability remain under-researched, including how changes in some processes (e.g., wave setup, river runoff) may have contributed to the historical mean sea level records obtained from tide gauges which are now used routinely in large-scale climate research.

Philip L Woodworth↗

Forcing Factors Affecting Sea Level Changes at the Coast

We review the characteristics of sea level variability at the coast focussing on how it differs from the variability in the nearby deep ocean. Sea level variability occurs on all timescales, with processes at higher frequencies tending to have a larger magnitude at the coast due to resonance and other dynamics. In the case of some processes, such as the tides, the presence of the coast and the shallow waters of the shelves results in the processes being considerably more complex than offshore. However, ‘coastal variability’ should not always be considered as ‘short spatial scale variability’ but can be the result of signals transmitted along the coast from 1000s km away. Fortunately, thanks to tide gauges being necessar-ily located at the coast, many aspects of coastal sea level variability can be claimed to be better understood than those in the deep ocean. Nevertheless, certain aspects of coastal variability remain under-researched, including how changes in some processes (e.g., wave setup, river runoff) may have contributed to the historical mean sea level records obtained from tide gauges which are now used routinely in large-scale climate research.

Philip L. Woodworth↗

The Mean Seasonal Cycle in Relative Sea Level From Satellite Altimetry and Gravimetry

Satellite altimetry and gravimetry are used to determine the mean seasonal cycle in relative sea level, a quantity relevant to coastal flooding and related applications. The main harmonics (annual, semiannual, terannual) are estimated from 25 years of gridded altimetry, while several conventional altimeter “corrections” (gravitational tide, pole tide, and inverted barometer) are restored. To transform from absolute to relative sea levels, a model of vertical land motion is developed from a high-resolution seasonal mass inversion estimated from satellite gravimetry. An adjustment for annual geocenter motion accounts for use of a center-of-mass reference frame in satellite orbit determination. A set of 544 test tide gauges, from which seasonal harmonics have been estimated from hourly measurements, is used to assess how accurately each adjustment to the altimeter data helps converge the results to true relative sea levels. At these gauges, the median annual and semiannual amplitudes are 7.1 cm and 2.2 cm, respectively. The root-mean-square differences with altimetry are 3.24 and 1.17 cm, respectively, which are reduced to 1.93 and 0.86 cm after restoration of corrections and adjustment for land motion. Example outliers highlight some limitations of present-day coastal altimetry owing to inadequate spatial resolution: upwelling and currents off Oregon and wave setup at Minamitori Island.

Richard D Ray↗

Ultrasonic Nondestructive Characterization of Adhesive Bonds

Qualitative measurements of adhesion or binding forces can be accomplished, for example, by using the reflection coefficient of an ultrasound or by using thermal waves (Light and Kwun, 1989, Achenbach and Parikh, 1991, and Bostrom and wickham, 1991). However, a quantitative determination of binding forces is rather difficult. It has been observed that higher harmonics of the fundamental frequency are generated when an ultrasound passes through a nonlinear material. It seems that such non-linearity can be effectively used to characterize the bond strength. Several theories have been developed to model this nonlinear effect (Adler and Nagy, 1991; Achenbach and Parikh, 1991; Parikh and Achenbach, 1992; and Hirose and Kitahara, 1992; Anastasi and Roberts, 1992). Based on a microscopic description of the nonlinear interface binding force, a quantitative method was presented by Pangraz and Arnold (1994). Recently, Tang, Cheng and Achenbach (1997) made a comparison between the experimental and simulated results based on this theoretical model. A water immersion mode-converted shear wave through-transmission setup was used by Berndt and Green (1997) to analyze the nonlinear acoustic behavior of the adhesive bond. In this project, the nonlinear responses of an adhesive joint was investigated through transmission tests of ultrasonic wave and analyzed by the finite element simulations. The higher order harmonics were obtained in the tests. It is found that the amplitude of higher harmonics increases as the aging increases, especially the 3dorder harmonics. Results from the numerical simulation show that the material nonlinearity does indeed generate higher order harmonics. In particular, the elastic-perfect plastic behavior generates significant 3rd and 5th order harmonics.

Qu, Jianmin↗

Microwave Treatment for Cardiac Arrhythmias

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

Transcatheter Antenna For Microwave Treatment

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiation having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may he used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

In Vivo Simulator for Microwave Treatment

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about 6 GHz. A computer simulation provides initial screening capabilities for an antenna such as antenna. frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 GHz and 12 GHz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

VLF wave stimulation by pulsed electron beams injected from the Space Shuttle

Among the investigations conducted on the Space Shuttle flight STS-3 of March 1982 was an experiment in which a 1-keV, 100-mA electron gun was pulsed at 3.25 and 4.87 kHz. The resultant waves were measured with a broadband plasma wave receiver. At the time of flight the experimental setup was unique in that the electron beam was square wave modulated and that the Shuttle offered relatively long times for in situ measurements of the ionospheric plasma response to the VLF pulsing sequences. In addition to electromagnetic response at the pulsing frequencies the wave exhibited various spectral harmonics as well as the unexpected occurrence of 'satellite lines' around those harmonics. Both phenomena occurred with a variety of different characteristics for different pulsing sequences.

Reeves, G. D.↗

Background-Oriented Schlieren for Large-Scale and High-Speed Aerodynamic Phenomena

Visualization of the flow field around a generic re-entry capsule in subsonic flow and shock wave visualization with cylindrical explosives have been conducted to demonstrate sensitivity and applicability of background-oriented schlieren (BOS) for field experiments. The wind tunnel experiment suggests that BOS with a fine-pixel imaging device has a density change detection sensitivity on the order of 10(sup -5) in subsonic flow. In a laboratory setup, the structure of the shock waves generated by explosives have been successfully reconstructed by a computed tomography method combined with BOS.

Mizukaki, Toshiharu↗

Looking for Speed!! Go Optical Ultra-Fast Photonic Logic Gates for the Future Optical Communication and Computing

Recently, we developed two ultra-fast all-optical switches in the nanosecond and picosecond regimes. The picosecond switch is made of a polydiacetylene thin film coated on the interior wall of a hollow capillary of approximately 50 micron diameter by a photo-polymerization process. In the setup a picosecond Nd:YAG laser at 10 Hz and at 532 nm with a pulse duration of approximately 40 ps was sent collinearly along a cw He-Ne laser beam and both were waveguided through the hollow capillary. The setup functioned as an Exclusive OR gate. On the other hand, the material used in the nanosecond switch is a phthalocyanine thin film, deposited on a glass substrate by a vapor deposition technique. In the setup a nanosecond, 10 Hz, Nd:YAG laser of 8 ns pulse duration was sent collinearly along a cw He-Ne laser beam and both were wave-guided through the phthalocyanine thin film. The setup in this case functioned as an all-optical AND logic gate. The characteristic table of the ExOR gate in polydiacetylene film was attributed to an excited state absorption process, while that of the AND gate was attributed to a saturation process of the first excited state. Both mechanisms were thoroughly investigated theoretically and found to agree remarkably well with the experimental results. An all-optical inverter gate has been designed but has not yet been demonstrated. The combination of all these three gates form the foundation for building all the necessary gates needed to build a prototype of an all-optical system.

Abdeldayem, Hossin↗

The propagation of spark-produced N waves through turbulence

A model experiment was designed and built to simulate the propagation of sonic booms through atmospheric turbulence. The setup of the model experiment is described briefly. Measurements of the N waves after they propagated across the turbulent velocity field reveal the same waveform distortion and change in rise time as for sonic booms. The data from the model experiment is used to test sonic boom models. Some models yield predictions for the waveform distortion, while others give estimates of the rise time of the sonic booms. A new theoretical model for the propagation of plane N waves through a turbulent medium is described.

Lipkens, Bart↗

Ultrasonic Nondestructive Characterization of Adhesive Bonds

Adhesives and adhesive joints are widely used in various industrial applications to reduce weight and costs, and to increase reliability. For example, advances in aerospace technology have been made possible, in part, through the use of lightweight materials and weight-saving structural designs. Joints, in particular, have been and continue to be areas in which weight can be trimmed from an airframe through the use of novel attachment techniques. In order to save weight over traditional riveted designs, to avoid the introduction of stress concentrations associated with rivet holes, and to take full advantage of advanced composite materials, engineers and designers have been specifying an ever-increasing number of adhesively bonded joints for use on airframes. Nondestructive characterization for quality control and remaining life prediction has been a key enabling technology for the effective use of adhesive joints. Conventional linear ultrasonic techniques generally can only detect flaws (delamination, cracks, voids, etc) in the joint assembly. However, more important to structural reliability is the bond strength. Although strength, in principle, cannot be measured nondestructively, a slight change in material nonlinearity may indicate the onset of failure. Furthermore, microstructural variations due to aging or under-curing may also cause changes in the third order elastic constants, which are related to the ultrasonic nonlinear parameter of the polymer adhesive. It is therefore reasonable to anticipate a correlation between changes in the ultrasonic nonlinear acoustic parameter and the remaining bond strength. It has been observed that higher harmonics of the fundamental frequency are generated when an ultrasonic wave passes through a nonlinear material. It seems that such nonlinearity can be effectively used to characterize bond strength. Several theories have been developed to model this nonlinear effect. Based on a microscopic description of the nonlinear interface binding force, a quantitative method was presented. Recently, a comparison between the experimental and simulated results based on a similar theoretical model was presented. A through-transmission setup for water immersion mode-converted shear waves was used to analyze the ultrasonic nonlinear parameter of an adhesive bond. In addition, ultrasonic guided waves have been used to analyze adhesive or diffusion bonded joints. In this paper, the ultrasonic nonlinear parameter is used to characterize the curing state of a polymer/aluminum adhesive joint. Ultrasonic through-transmission tests were conducted on samples cured under various conditions. The magnitude of the second order harmonic was measured and the corresponding ultrasonic nonlinear parameter was evaluated. A fairly good correlation between the curing condition and the nonlinear parameter is observed. The results show that the nonlinear parameter might be used as a good indicator of the cure state for adhesive joints.

Qu, Jianmin↗

Combined single-pulse holography and time-resolved laser schlieren for flow visualization

A pulsed ruby laser and continuous-wave argon ion laser were used in a combined setup at the Langley Expansion Tube for single pulse holography and time resolved laser schlieren with a common optical axis. The systems can be operated simultaneously for a single run. For a single frame, the pulsed holographic setup offers the options of shadowgraph, Schlieren, and interferometry from the reconstructed hologram as well as the advantage of post-run sensitivity adjustments. For flow establishment studies the time resolved laser Schlieren provides visualization of the flow field every 12.5 microns for up to 80 frames with an exposure time per frame of 5.4 microns.

Burner, A. W.↗

Progress in Interferometric Rayleigh Scattering to Measure Fluctuations Spectra of Velocity and Temperature in High Speed Flows

A new, spectrally-resolved, Rayleigh scattering setup at NASA Ames is further developed to measure fluctuations in velocity and temperature. Using a combination of a continuous-wave laser, a stabilized Fabry-Perot interferometer (FPI), an EMCCD camera, and a photo-multiplier tube, the setup was demonstrated to provide fairly accurate measurements of time-averaged velocity, temperature, density and spectrum of density fluctuations in a high-speed free jet (Panda & White, 2018). This paper describes further progress in fast measurement of the Rayleigh-Brillouin spectrum via a 16-anode linear-array of photo-multiplier tube and a multi-channel, photo-electron counter. Rayleigh scattered light from a 0.4mm long probe volume was directly imaged through the FPI and was imaged on the linear array. Synchronous photo-electron counting over a series of short, contiguous gates provided time-evolution of the fringes at a 10 kHz sampling rate. Sample spectra collected from a Mach 0.98 jet show spectral content floating on high noise-floor. Efforts to collect longer time series of data and different schemes of extracting velocity and temperature information are now in progress.

Panda, J.↗

Research in millimeter wave techniques

The following technical developments are described: (1) a reliable 183 GHz subharmonic mixer, (2) a precision noise figure test setup, (3) the successful deposition of SiO2 on a noncontacting backshort, and (4) sturdier whisker points used for diode contacting.

Forsythe, R. E.↗