Effect of wind turbine generator model and siting on wind power changes out of large WECS arrays

Methods of reducing the WECS generation change through selection of the wind turbine model for each site, selection of an appropriate siting configuration, and wind array controls are discussed. An analysis of wind generation change from an echelon and a farm for passage of a thunderstorm is presented. Reduction of the wind generation change over ten minutes is shown to reduce the increase in spinning reserve, unloadable generation and load following requirements on unit commitment when significant WECS generation is present and the farm penetration constraint is satisfied. Controls on the blade pitch angle of all wind turbines in an array or a battery control are shown to reduce both the wind generation change out of an array and the effective farm penetration in anticipation of a storm so that the farm penetration constraint may be satisfied.

Schleuter, R. A.

Some alternative dynamic design configurations for large horizontal axis WECS

The present U.S. development effort toward large horizontal axis WECS concentrates on the configuration with two rigid blades with collective pitch variation and a yaw gear drive. Alternative configurations without yaw gear drive were considered where the rotor is either selfcentering or where the yaw angle is controlled by blade cyclic pitch inputs. A preliminary evaluation of the dynamic characteristics for these alternative design configurations is presented.

Hohenemser, K. H.

AC motor and generator requirements for isolated WECS

After surveying electrically driven loads used on productive farms, the investigators chose three pumps for testing at voltages and frequencies far outside the normal operating range. These loads extract and circulate water and move heat via air, and all are critical to farm productivity. The object was to determine the envelope of supply voltage and frequency over which these loads would operate stably for time intervals under 1 hour. This information is among that needed to determine the feasibility of supplying critical loads, in case of a utility outage, from a wind driven alternator whose output voltage and frequency will vary dramatically in most continental wind regimes. Other related work is surveyed. The salient features and limitations of the test configurations used and the data reduction are described. The development of simulation models suitable for a small computer are outlined. The results are primarily displayed on the voltage frequency plane with the general conclusion that the particular pump models considered will operate over the range of 50 to 90 Hz and a voltage band which starts below rated, decreases as frequency decreases, and is limited on the high side by excessive motor heating. For example, centrifugal pump operating voltage ranges as extensive .4 to 1.4 appear possible. Particular problems with starting, stalling due to lack of motor torque, high speed cavitation, and likely overheating are addressed in a listing of required properties for wind driven alternators and their controllers needed for use in the isolated or stand alone configuration considered.

Park, G. L.

Winding for the wind

The mechanical properties and construction of epoxy-impregnated fiber-glass blades for wind turbines are discussed, along with descriptions of blades for the Mod 0A and Mod 5A WECS and design goals for a 4 kW WECS. Multicell structure combined with transverse filament tape winding reduces labor and material costs, while placing a high percentage of 0 deg fibers spanwise in the blades yields improved strength and elastic properties. The longitudinal, transverse, and shear modulus are shown to resist stresses exceeding the 50 lb/sq ft requirements, with constant stress resistance expected until fatigue failure is approached. Regression analysis indicates a fatigue life of 400 million operating cycles. The small WECS under prototype development features composite blades, nacelle, and tower. Rated at 5.7 kW in a 15 mph wind, the machine operates over a speed range of 9-53.9 mph and is expected to produce 16,200 kWh annually in a 10 mph average wind measured at 30 ft.

Weingart, O.

NASA’s Orion Crew Module Seakeeping Simulation and Test Comparisons in Ocean Wave Environments

The NASA Orion Crew Module (CM) post-landing seakeeping and uprighting capabilities are being evaluated across a variety of ocean wave conditions. This paper provides an overview of quarter-scale and full-scale test data and how it compares with the CM seakeeping dynamic simulation results evaluated using Wave Energy Convertor Simulator (WEC-Sim).This includes a discussion of the status of the dynamic modeling effort, correlation of model inputs with the wave field from the test, and a comparison of the results against the physical test data with emphasis on the full-scale results. Analysis in the frequency domain showed similar response characteristics between the model and the test and shows energy peaks corresponding to both the natural response and the forced response due to the wave environment. Time domain comparisons showed that the linear WEC-Sim model under predicted the amplitude of the pitch and roll motion of the test article, with improved matching for smaller, longer crested waves. An attempt was made to correlate the pitch/roll response to incident wave slope to account for a possible delay in the BTA’s response. The results did not show a strong relationship in the response characteristics to incident wave slope, but better correlation was seen by comparing responses in the frequency domain. Evaluation of the simulation’s ability to match test results aided in understanding the current fidelity of the CM model in WEC-Sim and identifying areas for model improvement

Abigail Lockard

Evaluating the Global Water and Energy Cycles in Reanalyses Using Ensemble Spread

Reanalyses provide continuous observation based global data over weather and climate time scales through observational assimilation. Ensemble forecasts are a component of modern data assimilation systems, providing information to the analysis process. Storing this spread over the duration of a climate reanalysis will provide insight to the variations of the model that underlies the reanalysis data. Global water and energy cycles (WECs) are a critical aspect of both weather and climate, yet there are some large gaps in the observation of key components as well as their representation in models and reanalyses. NASA’s Water and Energy cycle Studies (NEWS) program is developing a corrected and balanced budget data set that is closed at monthly and regional scales during the 21st century, so far. In this paper, we will evaluate reanalysis WEC components against the initial NEWS collection of observation, but integrate the analysis spread from the reanalysis data assimilation as a new perspective on the evaluation. The initial evaluation will cover a few more recent years using ERA5 10 member spread. As the GMAO’s production of the Modern-Era Retrospective analysis for Research and Applications 21st Century (MERRA-21C) progresses, the effort will include the MERRA-21C 32 member spread. Ultimately, we will explore the potential of the ensemble spread as a measure of uncertainty in the reanalysis.

Michael Bosilovich

The U.S.-NSF/NASA

The five-year research and development plan of the NSF/NASA Wind Energy Conversion Systems (WECS) program is outlined. The program includes mission studies to determine energy use patterns and requirements and define specific applications for wind energy systems, wind energy resource assessment and development, and development of cost-effective components and subsystems. The program is also directed towards the development of energy storage systems to make wind powered systems firm power sources where appropriate. A 100 kW experimental wind generator (Model Zero) is being designed as a flexible test bed for a variety of system components. Designs will be developed for units in the 50 to 200 kW and 500 to 3000 kW size ranges.

Source record

Flow field analysis

The average mean wind speed integrated over a disk is shown to be extremely close to the mean value of wind speed which would be measured at the center of a disk for most geometries in which a WECS (Wind Energy Conversion System) would operate. Field test results are presented which compare instantaneous records of wind speed integrated over a disk with the wind speed measured at the center of the disk. The wind field that a rotating element would experience is presented which was synthesized from the outputs of an array of anemometers.

Cliff, W. C.

The Danish large wind turbine program

A brief description of the Danish wind energy program and its present status is given. Results and experiences from tests on the Gedser windmill (200 kW) are presented. The key results are presented from the preliminary design study and detailed design of two new WECS (630 kW each) is described.

Pederson, B. M.