EVALUATION OF PRESSURE DROP CORRELATIONS FOR THE WIRE-WRAPPED ROD BUNDLES

The accurate prediction of pressure drop in the fuel rod bundle is of importance for the design and thermal-hydraulic analysis of nuclear reactor system. Due to very complex geometry of wire-wrapped fuel rod bundle geometry for the Sodium Fast Reactor (SFR), a simple method using hydraulic (equivalent) diameter is not sufficient to predict the pressure drop of rod bundle accurately. For several decades, many experimental works have been performed to develop an accurate correlation for wire-wrapped fuel bundle friction factor. In these works, the friction factor correlation of wire-wrapped fuel bundle has been developed as a function of Reynolds number of the flow and the design parameters such as fuel pin diameter, wire diameter, rod pitch, and wire lead length. The Cheng and Todreas correlations are well-known and used in many subchannel analysis code, such as CADET, TRIO-U, MATRA-LMW, SE2-ANL, etc. Novendstern model, Rehme model, Baxi and Dalle Donne model are also well-known and widely referred. Computational Fluid Dynamics is another typical approach to predict the pressure drop of wire-wrapped fuel rod bundle, but it requires the model validation because the accuracy of pressure drop prediction by the CFD simulation depends on what turbulence model is employed. The present work aims at evaluating the existing pressure drop correlations for the wire-wrapped fuel rod bundle and evaluating the pressure drop of 217-pin rod bundle by the CFD analysis.

99 GENERAL AND MISCELLANEOUS↗

CFD Benchmark of Pressure Drop in a 61-Pin Wire-Wrapped Assembly with Blocked Channels Using NekRS

Thermal hydraulic behaviors of wire-wrapped rod bundles continue to be a subject of intense research. One of the leading next-generation designs, the sodium fast reactor, relies on a hexagonal assembly of wire-wrapped fuel pins. The issue of potential channel blockage has been raised as a safety concern due to the tightly packed arrangement of the fuel pins. This has led to several recent experimental and computational studies working to quantify the potential impact on the fluid flow and heat transfer behaviors of such blockages. The objective of the present study is to benchmark the high-fidelity NekRS CFD solver in predicting pressure drop for large blockages against available experimental data. A 61-pin wire-wrapped fuel assembly with two flow blockage configurations has been simulated and investigated at various low to moderate Reynolds numbers. The NekRS solver has been shown to yield exponentially decreasing spatial discretization errors with increasing polynomial order. All simulated results agreed well with measured data, which indicates that the overall methodology is adequate and consistent. The results of this benchmark study demonstrate the accuracy of NekRS for sodium fast reactor hydrodynamic simulations, increasing the confidence in its use for design, licensing, and analysis activities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Fidelity CFD Assessments of Flow Resistance in a 61-Pin Wire-Wrapped Assembly with Partially Blocked Channels

The examination of thermal-hydraulic behaviors in wire-wrapped rod bundles continues to be an active area of research. The sodium fast reactor, a prominent candidate in next-generation nuclear designs, utilizes a hexagonal configuration of wire-wrapped fuel pins. Here, the potential for channel blockage within this compact arrangement poses a significant safety challenge, spurring a number of recent experimental and computational investigations to evaluate its impact on flow and heat transfer. The present work aims to benchmark the high-fidelity NekRS computational fluid dynamics (CFD) solver in predicting the pressure drops associated with substantial blockages, using available experimental data as a reference. A 61-pin wire-wrapped fuel assembly with two flow blockage configurations has been simulated and investigated at a range of low to moderate Reynolds numbers (487 ≤ Re ≤ 14 600). The NekRS solver demonstrates an exponential reduction of spatial discretization error with increasing polynomial order. The high level of agreement between the numerical results and measured data confirms the accuracy and consistency of the present numerical approach. This benchmark study establishes the capability of NekRS to perform reliable hydrodynamic simulations for sodium fast reactor applications and supports its use in design, licensing, and safety analyses.

CFD Benchmarking↗

High-Fidelity Numerical Investigation on Elucidating Sodium Heat Transfer Characteristics for 37-Pin Wire-Wrapped Fuel Bundle in the PLANDTL Facility

This study involved a Reynolds-averaged Navier-Stokes- (RANS-) based computational fluid dynamics (CFD) analysis of the 37-pin wire-wrapped fuel bundle of the PNC Plant dynamics test loop (PLANDTL) facility. Previously, mainly the hydrodynamic phenomena of the wire-wrapped fuel bundle were analyzed, but the present study additionally included heat transfer analysis through conjugate heat transfer. The main purpose of the study was to benchmark the experimental data of the PLANDTL 37-pin wire-wrapped fuel bundle to investigate the heat transfer phenomena. In addition, the aim was to verify the accuracy of the RANS-based CFD analysis method using the STAR-CCM+ simulation software in comparison with the experimental data. The grid used for verification was an innovative grid system consisting of hexahedra using Fortran-based code. The development of the RANS-based CFD methodology included grid sensitivity analysis, turbulence model sensitivity analysis, and turbulent Prandtl number sensitivity analysis. Information on the temperature, mass flow rate, and area of the CFD results for each subchannel was provided for the top of the heated section and is expected to serve as a reference for future studies aiming to perform the validation and verification of a PLANDTL facility. In addition, the dependence of the peak temperature on the azimuth angle of each pin was analyzed.

97 MATHEMATICS AND COMPUTING↗

Experimental Study on the Effect of Localized Blockages on the Friction Factor of a 61-Pin Wire-Wrapped Bundle

Abstract The thermal-hydraulic behavior of the flow in rod bundles has motivated numerous experimental and computational investigations. Previous studies have identified potential for accumulation of debris within the small subchannels of typical wire-wrapped assemblies with subsequent total or partial blockage of subchannel coolant flow. A test campaign was conducted to study the effects of localized blockages on the bundle averaged friction factor of a tightly packed wire-wrapped rod bundle. Blockages were installed within the bundle, and fluid pressure drop was measured across one wire pitch for a Reynolds number range of 500–17,200. The Darcy–Weisbach friction factor of the perturbed rod bundle geometry was compared with that of the unblocked bundle, as well as with the predictions of a well-established friction factor correlation. Differing effects based on blockage size and location for various flow regimes were studied. A number of conclusions can be made about the effects of the blockages on the friction factor, such as an increasing effect of the blockage on friction factor with an increase in Reynolds number, a change in flow behavior in the turbulent transition flow regime near Reynolds number 3000, differences in effect on friction factor for different types of subchannel blockage, and a nonlinear trend in friction factor variation with flow area impeded for edge subchannels. To this end, all data and quantified uncertainty produced in this study are made available for comparison and validation of advanced computational tools.

Engineering↗

Coupled Monte Carlo Transport and Conjugate Heat Transfer for Wire-Wrapped Bundles Within the MOOSE Framework

Cardinal is an open-source application that couples OpenMC Monte Carlo transport and NekRS computational fluid dynamics (CFD) to the Multiphysics Object-Oriented Simulation Environment (MOOSE), closing neutronics and thermal-fluid gaps in conducting high-resolution multiscale and multiphysics analyses of nuclear systems. We first provide a brief introduction to Cardinal's software design, data mapping, and coupling strategy to highlight our approach to overcoming common challenges in high-fidelity multiphysics simulations. Here we then present two Cardinal simulations for hexagonal pin bundles. The first is a validation of Cardinal's conjugate heat transfer coupling of NekRS's Reynolds-Averaged Navier Stokes model with MOOSE's heat conduction physics for a bare seven-pin Freon-12 bundle flow experiment. Predictions for pin surface temperatures under three different heating modes agree reasonably well with experimental data and similar CFD modeling from the literature. The second simulation is a multiphysics coupling of OpenMC, NekRS, and BISON for a reduced-scale, seven-pin wire-wrapped version of an Advanced Burner Reactor bundle. Wire wraps are approximated using a momentum source model, and coupled predictions are provided for velocity, temperature, and power distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pressure Drop in Seven-Pin Wire-Wrapped Rod Bundle for the Sodium Cartridge Loop in Versatile Test Reactor

This work studies the hydrodynamics of the seven pin wire-wrapped rod bundle in the sodium cartridge loop for the Versatile Test Reactor (VTR) through scaled water experiments and computational fluid dynamics (CFD) simulations. Here, the scaling analysis is first performed to demonstrate the hydrodynamic similarity between water and sodium flows at the same Reynolds number Re. A separate-effects test facility is designed and constructed based on the scaling analysis. Detailed experimental data on the pressure drop covering a wide range of Re values (1165 to 27 689) are obtained, which are used to evaluate existing correlations for friction factor and to benchmark CFD simulations. The experimentally determined friction factors f Exp agree well with the Upgraded Cheng and Todreas Detailed Correlation and Pacio-Chen-Todreas Detailed Model within ±7% but are significantly underpredicted by Rehme's correlation by 25%. Various CFD near-wall treatment methods are tested using ANSYS Fluent and evaluated by experimental data. It is found that when the recommended wall y + values are met, most of the near-wall treatment methods can give accurate friction factor predictions. The resolved near-wall method (y + ~ 1) with the Shear Stress Transport k - ω turbulence model and the scalable wall functions (y + > 12) with the realizable k - ε turbulence model can predict f Exp within ±5% The standard wall functions (y + > 30) and nonequilibrium wall functions (y + > 30) with the realizable k - ε model can predict f Exp within ±10%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mechanical Solution for Existing Conductors

The rapid growth in energy demand, driven by advancements in AI technology, renewable energy integration, and increased industrial activity, highlights the need for innovative solutions to improve the resiliency and efficiency of the power grid. This report details the fire testing of GridWrap’s Composite WiRe Wrap, to evaluate the wrap's ability to enhance conductor performance under wildfire-simulated conditions. Conductors were prepared and tested in a controlled environment at 400°C for 18 minutes, during which sag and temperature data were recorded. The results demonstrated that the unwrapped conductor sagged 3/16ths of an inch, while the WiRe Wrapped conductor sagged only 1/16th of an inch under identical conditions, indicating a significant improvement in mechanical performance. This project, conducted as part of a collaborative effort between BEA (Idaho National Laboratory’s managing contractor) and GridWrap, Inc., demonstrates the potential of grid-enhancing technologies like WiRe Wrap to reduce sag, increase grid resiliency, and support the future energy landscape. By validating the performance of such technologies in real-world scenarios, this work provides critical insights for industry adoption, benefiting both grid operators and U.S. taxpayers through improved reliability, reduced emissions, and enhanced energy delivery.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Specification of EBR-II Contact Profilometry Data

All contact profilometry data stored in FIPD was originally measured using the HFEF vertical contact profilometer, which was an electronic gauge to measure the diameter profile of an element or capsule continuously over the region of interest. The element could be rotated as it passed through the probes if the wire wrap was not to be removed and the element could be returned to reactor for further irradiation. If the wire wrap was removed, the element could be drawn vertically through the probes, rotated, and the process repeated. In this way any cladding ovality could be observed. Figure 1 shows the setup used to measure the fuel pin diameter profile. The ambient temperature during the measurement was ~21-23 ºC. The cladding temperature during the measurement is considered to be similar to the ambient temperature by assuming the fuel decay heat did not impact the cladding temperature. Two documents contain most of the important details about contact profilometry measurements. The first one is the operational manual of the contact profilometer (title: Element contact profilometer operation and maintenance, HFEF/N OMM 4326, DOC. NO. W0202-0007-SA-01). This manual provides: (1) description of the contact profilometer including the functions of each component (support stage, sensing head, control system, and calibration standards, etc.); (2) step-by-step guidance on calibrations, operations, and measurements; and (3) maintenance procedures and other details of the contact profilometer. The second document is a publicly accessible report entitled “A Fuel-element Profilometer for the HFEF.” This report describes the development of the contact profilometer, including the design requirements, features, and details of each component, as well as the acceptance tests for the built system. This document is important because it reports the uncertainties of the measurements with detailed deduction procedures. The reported uncertainties should apply to all hard-copy contact profilometry data in FIPD. Some key information about contact profilometry measurements was extracted from these two documents. Combining the information with other sources, a specification for interpretating the contact profilometry data in FIPD was established.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ECAR-6330 Rev 0 Computational Fluid Dynamics Evaluation of Core Pressure Drop for the Primary Coolant Apparatus Test

PCAT is a thermal-hydraulic test loop for MARVEL reactor. The design gap thickness between the heater rods of PCAT core is 1.0 mm. The heater elements were manufactured within a straightness tolerance for the designed gap thickness, but several elements have been distorted out of tolerance during the welding process. The distortion of heater rods could lead to flow maldistribution and excessive hotspot temperature when the gap between two heater rods is too narrow. Wire-wraps are the spacer devices widely used in the sodium cooled fast reactor system to maintain the design fuel pitch. Generally, a wire spacer can enhance the turbulent heat transfer, but it increases the pressure drop, which is not desirable for a natural-circulation system like PCAT. Therefore, three short wire-wrap spacers per heater have been proposed to contain the core pressure drops and keep the heater-to-heater gap in an acceptable range. The objectives of this ECAR is to evaluate the PCAR core pressure drop with short wire spacers to confirm that the additional pressure drop due to the wire spacer will not disturb the natural circulation of the PCAT.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Phase 1 Specifications and preliminary sensitivity analyses of the OECD-NRC liquid metal fast reactor core thermal-hydraulics benchmark

The developments in wire-wrapped fuel bundle thermal-hydraulics research have become increasingly diverse and this makes comparisons across studies difficult. This paper describes an ongoing benchmark that will address this issue by directly comparing computational results with experimental data from two unique wire-wrapped thermal-hydraulic facilities. Preliminary subchannel sensitivity / uncertainty analyses show largely expected behavior for the presented cases, where rod diameter and friction factor show the greatest sensitivities to geometrical perturbations. Guidelines for computational fluid dynamics evaluations have been prepared and highlight the need for consolidated modeling strategies. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Helical superconducting undulator for 3rd and 4th generation of synchrotron light source and FELs

A helical superconducting undulator includes a cylindrical magnetic core through which a bore hole allows the passage of charged particles. A single superconducting wire wraps the magnetic core guided by helical flights and cylindrical protrusions, to create interleaved helical windings on the magnetic core. An electrical current may be supplied to the superconducting wire to generate a periodic helical magnetic field in the bore. The helical superconducting undulator also includes a strong-back enclosure that acts as an epoxy mold during epoxy impregnation, a structural support to ensure straightness of the undulator after epoxy impregnation, and assists in cooling and thermal control of the magnetic core and superconducting wire during device operation.

Gluskin, Efim↗

Design and performance of a 35-ton liquid argon time projection chamber as a prototype for future very large detectors

Liquid argon time projection chamber technology is an attractive choice for large neutrino detectors, as it provides a high-resolution active target and it is expected to be scalable to very large masses. Consequently, it has been chosen as the technology for the first module of the DUNE far detector. However, the fiducial mass required for “far detectors” of the next generation of neutrino oscillation experiments far exceeds what has been demonstrated so far. Scaling to this larger mass, as well as the requirement for underground construction places a number of additional constraints on the design. A prototype 35-ton cryostat was built at Fermi National Acccelerator Laboratory to test the functionality of the components foreseen to be used in a very large far detector. The Phase I run, completed in early 2014, demonstrated that liquid argon could be maintained at sufficient purity in a membrane cryostat. A time projection chamber was installed for the Phase II run, which collected data in February and March of 2016. The Phase II run was a test of the modular anode plane assemblies with wrapped wires, cold readout electronics, and integrated photon detection systems. While the details of the design do not match exactly those chosen for the DUNE far detector, the 35-ton TPC prototype is a demonstration of the functionality of the basic components. Measurements are performed using the Phase II data to extract signal and noise characteristics and to align the detector components. A measurement of the electron lifetime is presented, and a novel technique for measuring a track's position based on pulse properties is described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ducted Assembly Steady-State Heat Transfer Software (DASSH): Theory Manual

The Ducted Assembly Steady-State Heat transfer software (DASSH) is being developed at Argonne National Laboratory to obtain a steady-state thermal fluids result for the coolant flow and temperature distribution in a hexagonally gridded reactor core with ducted assemblies. In DASSH, each assembly is assumed to contain a hexagonal bundle of wire-wrapped pins. DASSH divides the coolant in the pin bundle into subchannels on which it applies energy balances to determine coolant and duct temperatures. DASSH offers multiple models for inter assembly heat transfer and features the ability to calculate pin temperatures. This document describes the models and equations implemented in DASSH. It includes a description of the geometric system to which the models are applied and a derivation of the subchannel energy balance formulation is presented. It also reviews the available correlations and provides an overview of the process by which power distributions are generated. Finally, it covers the code execution procedure, discussing the main code objects and their interactions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

H 2 Production Pathways Cost Analysis (2016 - 2021) (Final Report)

This final report documents cost analysis conducted for the Department of Energy over a five year period (2016 to 2021) pertaining to hydrogen production and delivery system components, focusing on the key remaining challenges of the technology pathways within the Hydrogen Production and Delivery sub-program portfolio. A particular focus was placed on electrolysis for the generation of hydrogen. The effort primarily used the H2A discounted cash flow computational model as a tool to project hydrogen cost ($/kgH 2 ) and determine status improvements resulting from technology advancements. The effort also considered cost as a function of production volume, employed error bars to illustrate uncertainties in the cost estimates, and utilized sensitivity analyses to show the potential for cost reductions. The project examined a range of hydrogen production and delivery related systems. These included WireTough wire-wrapped pressure vessels for hydrogen storage, proton exchange membrane (PEM) electrolysis, solid oxide electrolysis (SOE), anion exchange membrane (AEM) electrolysis, photoelectrochemical (PEC) electrolysis, solar thermochemical hydrogen (STCH) production, the cost of energy transmission, and a study on the necessary price of hydrogen to produce competitively-priced electricity via fuel cell conversion.

08 HYDROGEN↗