Search NASASearch

SEARCH · Search NASA

Results for “Wildfire management, UAS, drones”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Multi-Tier Autonomous Aerial Architecture for Wildfire Detection, Characterization, and Communication in Infrastructure-Denied Environments

Wildfire response depends on how fast an ignition can be confirmed and located, especially in remote regions where ground-based communication and monitoring may be limited. Geostationary sensors provide frequent observations but at kilometer-scale resolution, which is too coarse to resolve small fires in remote terrain. Ground camera networks require sightlines and infrastructure that back-country areas lack. To address these limitations, this work proposes a Multi-Tier Autonomous Wildfire Intelligence System that combines wide-area monitoring with targeted, high-resolution sensing. A solar-powered high-altitude long endurance (HALE) platform operating at approximately 60,000 ft provides persistent wide-area thermal and optical surveillance, running onboard edge inference to screen candidate ignitions and reduce false positives and downlink bandwidth. When a candidate ignition is detected, low-altitude uncrewed aircraft systems (UAS) can be deployed to conduct localized observations, including high-resolution imaging and atmospheric measurements such as wind and plume observation. By combining persistent detection with local sensing, the proposed architecture is designed to provide first responders with timely, high-resolution information about fire location and behavior to aid in emergency decision making.

Wildfire management, UAS, drones

Proactive Wildfire Management: A Remote Sensing and Multimodal CNN-MLP Architecture for Ignition Risk Forecasting

As the frequency and intensity of wildfires increase, with fire seasons now starting earlier and ending later than they have over the past decades, current monitoring systems, such as lookout towers and satellites, are hindered by cloud cover, low-resolution imagery, and static data gaps that fail to track vegetation moisture levels fast enough to catch rapid pre-ignition changes. This report proposes a Machine Learning-enabled Wildfire Ignition Prediction framework that combines satellite monitoring with dynamic and high-resolution remote sensing from Unmanned Aerial Vehicle (UAV) swarms. The method would use multispectral and thermal data from the Landsat program to create a baseline for vegetation health, calculating a two-band Enhanced Vegetation Index (EVI2) and the moisture content of the vegetation. These inputs will later be fused with microscale UAV weather data, including thermal hotspots found through thick canopies, hyperspectral chemical signatures of pre-visual combustion, and local weather streams. The multispectral satellite, multispectral Light Detection and Ranging (LiDAR), and thermal data would then be processed through a Convolutional Neural Network (CNN), alongside a Multilayer Perceptron (MLP) for the micro-weather telemetry. The outputs of these networks would be fused into a single feature representation and passed through a final prediction network to generate real-time ignition risk scores and hotspot alerts. Model performance would be assessed using standard classification metrics, including a Receiver Operating Characteristic - Area Under the Curve (ROC AUC) and F1 score. This system would allow first responders to identify high-risk zones and intervene before ignition occurs, improving emergency response time compared to current approaches.

machine learning

Advancing Wildfire Monitoring with TEMPO and ML tools: Hourly Smoke and Fire‑Front Mapping and Near‑Surface NO₂ Predictions

Wildfires impose substantial impacts on communities and regions downwind of wildfire smoke. We present a TEMPO‑enabled workflow that generates value‑added Level‑3 smoke‑plume masks and fire‑front maps for large wildfires, such as 2024 Park Fire, using the self‑supervised deep learning system SIT‑FUSE, along with near‑surface NO₂ predictions produced by a foundation model (Microsoft Aurora). We conclude by outlining a roadmap for expanding these capabilities to additional Western U.S. wildfire events and for delivering actionable tools to stakeholders. This open-source, reproducible workflow provides a scalable framework for cross-agency wildfire monitoring to overcome traditional limitations in smoke-cloud discrimination and air-quality forecasting by incorporating TEMPO data and beyond.

Xiaohua Pan

Case study of UAS ignition of prescribed fire in a mixedwood on the William B. Bankhead National Forest, Alabama

Abstract Background For at least four decades, practitioners have recognized advantages of aerial versus ground ignition for maximizing the effectiveness of prescribed fires. For example, larger areas can be ignited in less time, or ignition energy may be variously targeted over an area in accordance with the uneven distribution of fuels. The maturation of wireless communication, geopositioning systems, and unmanned aerial systems (UAS) has enhanced those advantages, and UAS approaches also provide further advantages relative to helicopter ignitions, such as reduced risk to human safety, lower operating costs, and higher operational flexibility. In a long running study at the Bankhead National Forest in northcentral Alabama, prescribed fire has been used for nearly 20 years. Most of the burns have been hand-ignited via drip torches, while some have been aerially ignited via helicopter. In March 2022, for the first time, a UAS was used to ignite prescribed fires across a landscape that included a long-term research stand. This field note relates comparisons of both fire behavior and fuel consumption metrics for the UAS-ignited burn versus previous burns on the same stand, and versus burns of other research stands in the same year. Results The UAS-ignited prescribed fire experienced burn effects similar to those from ground-ignited prescribed fires on the same stand in previous years, as well as those from ground-ignited prescribed fires on other stands in the same year. Conclusion This post hoc analysis suggests that UAS ignition approaches may be sufficient for achieving prescribed burn goals, thereby enabling practitioners to realize the advantages offered by that ignition mode.

Environmental Sciences & Ecology

Observing low-altitude features in ozone concentrations in a shoreline environment via uncrewed aerial systems

Abstract. Ozone is a pollutant formed in the atmosphere by photochemical processes involving nitrogen oxides (NOx) and volatile organic compounds (VOCs) when exposed to sunlight. Tropospheric boundary layer ozone is regularly measured at ground stations and sampled infrequently through balloon, lidar, and crewed aircraft platforms, which have demonstrated characteristic patterns with altitude. Here, to better resolve vertical profiles of ozone within the atmospheric boundary layer, we developed and evaluated an uncrewed aircraft system (UAS) platform for measuring ozone and meteorological parameters of temperature, pressure, and humidity. To evaluate this approach, a UAS was flown with a portable ozone monitor and a meteorological temperature and humidity sensor to compare to tall tower measurements in northern Wisconsin. In June 2020, as a part of the WiscoDISCO20 campaign, a DJI M600 hexacopter UAS was flown with the same sensors to measure Lake Michigan shoreline ozone concentrations. This latter UAS experiment revealed a low-altitude structure in ozone concentrations in a shoreline environment showing the highest ozone at altitudes from 20–100 m a.g.l. These first such measurements of low-altitude ozone via a UAS in the Great Lakes region revealed a very shallow layer of ozone-rich air lying above the surface.

Meteorology & Atmospheric Sciences

Revealing Hidden Quinones Through Diagnostic MS² Fragmentation of Peptide–Quinone Adducts

Quinones are redox-active components of natural organic matter that mediate electron transfer and influence biogeochemical processes, but many quinones in pyrogenic organic matter (PyOM) remain unresolved because they ionize poorly by mass spectrometry. Here, we present a peptide-tagging approach to improve detection of cysteine-reactive electrophiles in PyOM, with quinones expected to be a dominant subset based on reaction chemistry and selectivity experiments. A cysteine-containing peptide was used to form Michael-addition adducts, enhancing electrospray ionization and enabling untargeted screening by high-performance liquid chromatography-high-resolution tandem mass spectrometry. The method was benchmarked with five quinone standards and applied to extracts from charred plant material as a discovery-level screen for cysteine-reactive targets. We identified 98 quinone-candidate adducts (mean neutral mass ~603 Da), of which more than 70% were not detectable in native MS1 data. Among formula-assigned features, hidden quinone candidates had median (O+N)/C of 0.391 and normalized oxidation state of carbon of -0.281, consistent with relatively low polarity and low oxidation state. These results reveal a previously inaccessible pool of hidden redox-active compounds in PyOM and provide a framework for prioritizing quinone-like electrophiles for confirmation and incorporation into models of fire-driven biogeochemical cycling.

LC-MS/MS

Jumpstart Opportunities to Unleash Leadership in Energy Storage (JOULES)

Current-generation Li-ion batteries with cobalt- and nickel-containing cathodes and graphite anodes are approaching performance and cost limits. In this program, 24M Technologies, Inc. (24M) is teaming with the Massachusetts Institute of Technology (MIT) and University of Michigan (UM) to develop low cost and fast charging sodium metal batteries with good low-temperature performance and high energy density, building upon previous work performed under ARPA-E programs. Key achievements include optimization of solid electrolyte and anode current collector, optimized cathode active materials, development of high-performance electrolyte formulations, and integration of these components into full cells. The cell design incorporates (1) an ultra-thick cathode (>9 mAh/cm 2 ) comprising advanced cobalt-free, sodium cathode active material, (2) advanced fast-charging electrolyte (up to 12 mS/cm) developed using machine learning and automated high-throughput screening technology by UM, and (3) ceramic modified separator that enable smooth Na transport and deposition, developed at MIT, enabling a high-energy density anode-free configuration and maximizing the energy density of sodium batteries. The team has successfully combined these approaches to sodium chemistry and paved the way to meeting the fast-charging, high-energy density, and low-cost requirements of next-generation drone, electric vertical take-off and -landing, and electric vehicle batteries. Performance for anode-free sodium cells developed under this program is more powerful than the commercial Li-ion batteries. The final deliverable cell design has achieved over 300 Wh/kg and volumetric energy density above 800 Wh/L (Table 1). Additionally, the team has achieved over (1) a lifetime of 340 cycles, (2) 80% capacity retention at -20 °C (compared 25 °C), and (3) the ability to fast charge to 80% SOC in 20 minutes.

25 ENERGY STORAGE

Microprocessor controlled advanced battery management systems

The advanced battery management system described uses the capabilities of an on-board microprocessor to: (1) monitor the state of the battery on a cell by cell basis; (2) compute the state of charge of each cell; (3) protect each cell from reversal; (4) prevent overcharge on each individual cell; and (5) control dual rate reconditioning to zero volts per cell.

W. T. Payne

Nickel-Cadmium Battery Operation Management Optimization Using Robust Design

In recent years following several spacecraft battery anomalies, it was determined that managing the operational factors of NASA flight NiCd rechargeable battery was very important in order to maintain space flight battery nominal performance. The optimization of existing flight battery operational performance was viewed as something new for a Taguchi Methods application.

NiCd rechargeable battery Taguchi Methods applicat

Design and Analysis of Battery Thermal Management Systems

Thermal management of battery cell packs is a critically needed technology. The purpose of this work is to design new and improved Battery Thermal Management Systems (BTMS) for use in electric airplanes. The BTMS should be 3D printable and hold twelve to sixteen 18650 batteries. To minimize aircraft’s weight, an actively air-cooled battery pack was chosen to avoid the excess weight of water-cooled and phase change material (PCM) cooled packs. As a result, significant changes were made to remove all metal in the pack and replace it with lower density polymer matrix composites (PMCs) which can be additively manufactured. Two air cooled battery pack configurations (traditional propeller fans & bladeless fans) were designed, modeled, and compared. These packs were first modeled in SolidWorks 2021 3D CAD, then imported into COMSOL MultiPhysics to be studied using the “Heat Transfer in Solids and Fluids” module. The design with the bladeless fans eliminated the need to use high conductivity heavy metal to remove unwanted thermal energy. These bladeless fans were designed entirely out of PMCs. This thermal pack design weighs 0.04 kg less than that of the traditional propeller fans design and has increased the battery pack energy density by 8.25 Wh/kg.

Thermal Management System for Battery Packs

Ejecta Management in a Safe Lithium Ion Battery Design

As lithium-ion battery energy densities continue to rise, managing the heat and pressure generated during failure events has become increasingly critical. Safety systems must effectively relieve pressure without releasing sparks, flames, or particulate matter, requiring robust filtration solutions. The challenge is compounded by the reduced free volume available for gas expansion in high-density designs, which increases the demands on these filters. While significant progress has been made through experimental studies and modeling efforts to understand the behavior of ejecta during battery failures, there remains a pressing need for practical, rule-of-thumb sizing parameters. These parameters would help correlate high-energy waste streams with appropriate filter design, ensuring reliable containment and safety. This talk will explore recent experimental findings in this area and discuss the potential pathways for developing these essential sizing guidelines.

Ejecta Management

Management and Performance of APPLE Battery in High Temperature Environment

India's first experimental communication satellite, APPLE, carried a 12 AH Ni-Cd battery for supplying power during eclipse. Failure to deploy one of the two solar panels resulted in the battery operating in a high temperature environment, around 40 C. This also resulted in the battery being used in diurnal cycles rather than just half yearly eclipse seasons. The management and performance of the battery during its life of two years are described. An attempt to identify the probable degradation mechanisms is also made.

Suresh, M. S.

Development of a Digital Twin for Electrified Aircraft Powertrain Health Management

The augmentation of aircraft powertrains with electrical power systems is a promising path to reducing aircraft fuel consumption, emissions, and noise. Like conventional propulsion systems, electrified aircraft propulsion (EAP) systems will be subject to wear and tear throughout their lifecycles. System health management for EAP will enable efficient flight and maintenance scheduling, realizing economic, safety, and reliability benefits. A digital twin is, broadly, a dynamically updated virtual representation of an individual physical asset. This paper presents a Kalman filter-based approach for the development of a digital twin for an electrified powertrain and applies the approach to an EAP controls testbed. Measurements from nominal testbed operations are used to update a nonlinear model of the testbed. A Kalman filter is then created and used to identify and isolate anomalous testbed behavior based on measurements from off- nominal operations. Results show that the Kalman filter-based digital twin can monitor individual powertrain components’ health for degradation or other changes in performance. The applicability of the presented digital twin approach to any hybrid- or fully-electrified powertrain is emphasized.

Electrified Aircraft Propulsion

Revolutionizing thermal Management in Next-Generation AI data centers: Challenges and breakthrough innovations

Data centers (DCs) serve as critical infrastructure for powering the growth and evolution of AI. Next-generation AI DCs present unique challenges in thermal management driven by unprecedented computational demands. This paper provides a comprehensive summary of key stakeholder perspectives on technology gaps, infrastructure requirements, test bed needs, emerging opportunities, and preliminary solutions related to thermal management for AI DCs. It establishes six strategic pillars of thermal management for next generation AI DC: reliability, deployability, efficiency, resilience, measurability, and valorization. The discussion spans a range of critical topics, including advanced cooling technologies, thermal strategies for emerging modular and edge DCs, system-level optimization and control frameworks, infrastructure planning and grid integration designs, benchmarking approaches, and pathways for waste heat recovery and reuse. The proposed research, development, and demonstration efforts are aimed at accelerating the deployment of AI DCs while ensuring energy efficiency, reliability, safety, and regulatory compliance.

Wang, Pengtao [ORNL] (ORCID:0000000214713429)