Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wolter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A generalized sine condition and performance comparison of Wolter type II and Wolter-Schwarzschild extreme ultraviolet telescopes

An equation similar to the Abbe sine condition is derived for a Wolter type II telescope. This equation and the sine condition are then combined to produce a so called generalized sine condition. Using the law of reflection, Fermat's principle, the generalized sine condition, and simple geometry the surface equations for a Wolter type II telescope and an equivalent Wolter-Schwarzschild telescope are calculated. The performances of the telescopes are compared in terms of rms blur circle radius at the Gaussian focal plane and at best focus.

Saha, T. T.↗

A Monte Carlo Based Ray Tracing Tool for Evaluating Wolter-Type Prescriptions

Evaluating Wolter-like X-ray mirror prescriptions via ray tracing is useful for selecting and optimizing the right mirror prescriptions for a specified application. Moreover, incorporating real metrology data into a ray trace and simulating point spread functions (PSF) allows for performance predictions representative of real manufacturing errors and tolerances. In fulfillment of an internship project, an X-ray ray trace routine using a Monte-Carlo method has been developed to examine different Wolter-like prescriptions and characterize their theoretical performances over a specified field of view. This routine includes the ability to use real metrology data to evaluate the impact of figure error on imaging performance. As a test case, the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) Wolter-I mirror prescription and an equivalent Wolter-Schwarzschild prescription were traced and imaging performance of a specified field of view were mapped. Here we present the approach used in this routine, showcase example results, and discuss future goals for expanding the routine to address azimuthally varying figure errors and surface roughness.

X-ray optics↗

Formula for the rms blur circle radius of Wolter telescope based on aberration theory

A formula for the rms blur circle for Wolter telescopes has been derived using the transverse ray aberration expressions of Saha (1985), Saha (1984), and Saha (1986). The resulting formula for the rms blur circle radius over an image plane and a formula for the surface of best focus based on third-, fifth-, and seventh-order aberration theory predict results in good agreement with exact ray tracing. It has also been shown that one of the two terms in the empirical formula of VanSpeybroeck and Chase (1972), for the rms blur circle radius of a Wolter I telescope can be justified by the aberration theory results. Numerical results are given comparing the rms blur radius and the surface of best focus vs the half-field angle computed by skew ray tracing and from analytical formulas for grazing incidence Wolter I-II telescopes and a normal incidence Cassegrain telescope.

Shealy, David L.↗

Wolter Optics for Neutron Focusing

Focusing optics based on Wolter optical geometries developed for x-ray grazing incidence beams can be designed for neutron beams. Wolter optics are formed by grazing incidence reflections from two concentric conic sections (for example, a paraboloid and a hyperboloid). This has transformed observational X-ray astronomy by increasing the sensitivity by many orders of magnitude for research in astrophysics and cosmology. To increase the collection area, many reflecting mirrors of different diameters are nested with a common focal plane. These mirrors are fabricated using nickel-electroformed replication techniques. We apply these ideas to neutron focusing using nickel mirrors. We show an initial test of a conical mirror using a beam of cold neutrons. key words: electroformed nickel replication, focusing optics, grazing angle incidence, mirror reflection, neutron focusing, Wolter optics

Mildner, D. F. R.↗

Design of a neutron microscope based on Wolter mirrors

The predominant geometry for a neutron imaging experiment is that of a pinhole camera. Here, this is primarily due to the difficulty in focusing neutrons due to the weak refractive index, which is also strongly chromatic. Proof of concept experiments demonstrated that neutron image forming lenses based on reflective Wolter mirrors can produce quantitative, high spatial resolution neutron images while also increasing the time resolution compared to the conventional pinhole camera geometry. Motivated by these results, we report the design of a neutron microscope where two Wolter mirrors replace condensing and objective lenses, in direct analogy with typical visible light microscopes. Ray tracing results indicate that this system will yield 3 µm spatial resolution images with an acquisition time of order <1 s (10 4 faster than currently possible at this spatial resolution) with a field of view of about 5 mm in diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image Properties of an X-Ray Telescope of the Wolter-1 Type with Emphasis on Contrast Reduction by Diffuse Reflection

Theoretical and experimental results are presented on the geometrical-optic imaging properties of a Wolter-1 type paraboloid-hyperboloid X-ray telescope. Particular consideration is given to the effect of microroughness of the mirror on the imaging properties. Experiments were conducted in which scattering properties were determined as a function of wavelength, incidence angle, and roughness of the plane mirrors. Results indicate the need for optimization of mirror material and polishing technology as well as the development of improved mirror manufacturing techniques. The use of transmission gratings along with the Wolter-1 type telescope in spectroscopy applications is discussed.

Lenzen, R.↗

A Wolter type I LAMAR

Observational objectives for the LAMAR and their influence on the instrument design are discussed. It is concluded that the most important design parameter is the angular resolution of the LAMAR modules since it so strongly influences sensitivity, optical identifications, source confusion, spectral resolution for objective gratings and the ability to resolve small extended sources. A high resolution Wolter Type I LAMAR module is described, its hardware status discussed, and the performance of a LAMAR observatory presented. A promising technique for enhancing the reflectivity of Wolter Type I X-ray optics in a selected bandpass at high energy has been investigated and the performance of the LAMAR module, utilizing this method, has been calculated.

Catura, R. C.↗

Effects of a despaced secondary of a Wolter type II telescope on image quality

The focal shift of the Wolter type II telescope, a glancing incidence analog of the normal incidence Cassegrain telescope, due to the despacing of the secondary with respect to the primary, is analyzed. The location of the rms best focus on the optical axis can be derived from a resulting expression. The results are verified by ray tracing of an actual Wolter type II telescope.

Saha, T. T.↗

Transverse ray aberrations of Wolter type 1 telescopes

Transverse ray aberration expansions are derived for Wolter type 1 telescopes. The analysis gives third order aberration terms, most of the fifth order terms and two seventh order terms as functions of system parameters and entrance aperture coordinates. The third order distortion is negligible and, therefore, this term is omitted in the expansions. The spot diagrams derived from exact ray tracing and aberration expansions agree well. The importance of fifth and seventh order terms is discussed. The derived aberration expansions are also valid for Wolter type 2 telescopes.

Saha, Timo T.↗

Replicated Wolter-I X-ray Optics for Lightweight, High Angular Resolution, Large Collecting Area X-Ray Telescopes

The next generation of orbiting x-ray observatories will require high angular resolution telescopes that have an order of magnitude greater collecting area in the 0.1-10 keV spectral region than those currently under construction, but with a much lower weight and cost per unit area. Replicated Wolter-I x-ray optics have the potential to meet this requirement. The currently demonstrated capabilities of replicated Wolter-I optics will be described, and a development plan for creating lightweight, high angular resolution, large effective area x-ray telescopes will be presented.

Joy, M.↗

Methods for Reducing Singly Reflected Rays on the Wolter-I Focusing Figures of the FOXSI Rocket Experiment

In high energy solar astrophysics, imaging hard X-rays by direct focusing offers higher dynamic range and greater sensitivity compared to past techniques that used indirect imaging. The Focusing Optics X-ray Solar Imager (FOXSI) is a sounding rocket payload which uses seven sets of nested Wolter-I figured mirrors that, together with seven high-sensitivity semiconductor detectors, observes the Sun in hard X-rays by direct focusing. The FOXSI rocket has successfully flown twice and is funded to fly a third time in Summer 2018. The Wolter-I geometry consists of two consecutive mirrors, one paraboloid, and one hyperboloid, that reflect photons at grazing angles. Correctly focused X-rays reflect twice, once per mirror segment. For extended sources, like the Sun, off-axis photons at certain incident angles can reflect on only one mirror and still reach the focal plane, generating a pattern of single-bounce photons that can limit the sensitivity of the observation of faint focused X-rays. Understanding and cutting down the singly reflected rays on the FOXSI optics will maximize the instrument's sensitivity of the faintest solar sources for future flights. We present an analysis of the FOXSI singly reflected rays based on ray-tracing simulations, as well as the effectiveness of different physical strategies to reduce them.

FOXSI Rocket Experiment↗

Toward the fabrication of a 5 μm resolution Wolter microscope for the National Ignition Facility

Advancements in computer-controlled polishing, metrology, and replication have led to a x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. The mirror is a nickel-cobalt replicated full-shell mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed and fabricated for a 8 m source-to-detector distance microscope, with 10× magnification. A computer controlled polishing process corrected the low-frequency mandrel figure to < 2.0 nm RMS error. The mandrel design was optimized to reduce shell distortions that occur mainly < 20 mm from the shell ends. This design, in combination with improved replication tooling design and refined bath parameters informed by a detailed COMSOL model, have led to reductions in replication errors in the mirror shell. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated < 10 μm FWHM source plane imaging resolution. Here we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving 5 μm FWHM resolution.

Grazing Incidence, Wolter Microscope, X-ray Optics↗

Toward the fabrication of a 5- μm -resolution Wolter microscope for the National Ignition Facility (invited)

Advancements in computer-controlled polishing, metrology, and replication have led to an x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. Here, we present the fabrication and test of a nickel–cobalt replicated full-shell x-ray mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed for an 8-m source-to-detector-distance microscope, with 10× magnification, and was optimized to reduce shell distortions that occur within 20 mm of the shell ends. This, in combination with an improved replication tooling design and refined bath parameters informed by a detailed COMSOL Multiphysics® model, has led to reductions in replication errors in the mirrors. Mandrel surface fabrication was improved by implementing a computer-controlled polishing process that corrected the low-frequency mandrel figure error and achieved <2.0 nm RMS convergence error. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated <10 μm full-width at half-maximum (FWHM) spatial resolution. Here, we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving a program goal of 5 μm FWHM resolution.

47 OTHER INSTRUMENTATION↗

Design and simulation of multilayer coatings for a multi-channel Wolter-like x-ray imager with large field of view and high resolution

X-ray diagnostics are key instruments for understanding the physics behind inertial confinement fusion experiments. We report on the multilayer design optimization for the Toroidal X-ray Imager (TXI), a hard x-rays microscope instrument designed by Commissariat à l’énergie atomique (CEA) and Laboratoire Charles Fabry (LCF) to be installed on the National Ignition Facility. TXI includes six channels designed for three different energy bands centered on 8.7, 13, and 17.5 keV. Each channel is made up of two toroidal mirrors arranged in a Wolter-like configuration. The required field of view is 800 × 400 µm2, and the resolution should be better than 5 µm. In addition, we seek to estimate the spatial distribution of the temperature, which requires no spectral overlap of the different energy bands and a good spectral homogeneity of the image produced. The development of the multilayer coatings was performed in a two-step method. First, the coatings were optimized to obtain proper energy bands. Then, an x-ray tracing code was used to calculate the integrated optical response of each channel and adjust the response of the mirror to fulfill the requirements. To fulfill all the specifications, we propose an original design using a combination of two aperiodic coatings, one with a narrow bandwidth and the other one with a larger bandwidth.

hard x-rays↗

X-ray optical properties of a Wolter telescope

Physical properties and the fabrication sequence of a Wolter telescope are discussed. Such telescopes are intended to examine the dust scattering halos after being placed in orbit by a booster rocket launched from Australia.

Ondrusch, A.↗

Wolter-Schwarzschild optics for the extreme-ultraviolet - The Berkeley stellar spectrometer and the EUV Explorer

The design, fabrication and performance of two Wolter-Schwarzschild grazing incidence optics are described. Both telescopes have been figured by single point diamond turning and have achieved better than 15-arcsec on-axis imaging. The telescope for the stellar spectrometer is an f/10 Type II system with an effective area of 225 sq cm at 250 A and 300 cm2 at 500 A. The primary has a maximum diameter of 38 cm and was fabricated in three elements. The copper-plated aluminum substrate was diamond turned; following nickel plating, the surface was polished and coated with evaporated gold. The performance during a sounding rocket flight is discussed. The prototype telescope for the Extreme Ultraviolet Explorer is an f/1.24 Type I system with an effective field of view of 5.0-deg diameter. The telescope has a maximum diameter of 40 cm and was fabricated as a single element. The aluminum substrate is to be diamond turned; the nickel plated surface will be polished and electroplated with gold. The design choice and defocusing optimization aimed at maximizing the field of view and number of image pixels is examined.

Malina, R. F.↗

Calculated performance of a Wolter type I X-ray telescope coated by multilayers

Deposition of multilayered diffraction coatings on the reflecting surfaces of a Wolter type I X-ray telescope offers the potential of using Bragg reflection to achieve enhanced effective area in selected high energy bandpasses. The structure of a gold-carbon multilayer has been optimized for study of 1.8 A iron-line emission with an X-ray telescope designed for observations from Spacelab. The response of this mirror assembly has been calculated as a function of X-ray energy and the resulting effective area is enhanced by a factor of 10 and peaks at 160 sq cm with a bandpass of 0.4 keV FWHM. This enhanced response is sufficient to allow study of the angular distribution of iron-line emission from the 20 brightest cluster X-ray sources during a 7 day Spacelab mission. The possibility of achieving X-ray imaging in narrow bandpasses at even higher energies has been investigated. It is concluded that it should be possible to achieve effective areas of approximately 5 sq cm in bandpasses approximately 1 keV wide for energies in the 15-25 keV range, a spectral region of much importance during the impulsive phase of solar flares.

Catura, R. C.↗

High resolution large area modular array of reflectors /LAMAR/ Wolter type I X-ray telescope for Spacelab

The Spacelab Wolter type I X-ray telescope, which is intended for both astronomical observations and the functional verification of the future Large Area Modular Array of Reflectors (LAMAR) concept, comprises five mirrors and is designed to have a blur circle radius of 20 arcsec, with effective areas of (1) 400 sq cm at 0.25 keV, (2) 200 sq cm in the 0.5-2.0 keV range, and (3) 50 sq cm between 2 and 5 keV. A rotary interchange mechanism allows either of two imaging proportional counters to be placed at the telescope focus. The telescope's primary objective is the observational study of galactic and extragalactic X-ray sources, extending the work of the Einstein Observatory to fainter sources and higher energies. Secondarily, the costs and performance to be expected from the use of this telescope type in the LAMAR mission will be assessed.

Catura, R. C.↗