SEARCH · Search NASA
Results for “X RAY IRRADIATION”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Examining astrophysical gas cloud collapse using an optical depth-scaled, x-ray-irradiated, carbon-foam sphere
When stellar radiation interacts with a molecular cloud, the cloud's fate depends on the strength of the incident radiation and the radiation's mean-free-path within the cloud [F. Bertoldi, Astrophys. J. 346, 735–755 (1989)]. Under the right conditions, the radiation compresses the cloud and a star formation may occur. Where and when the stellar formation occurs in the cloud's collapse are open questions. Direct observation of the complete star–cloud lifecycle is nearly impossible due to the immense timescales and distances over which the interaction occurs. Laboratory astrophysics offers a way to investigate such a system by scaling the important astrophysical parameters to the laboratory. This work describes laboratory experiments to study the radiation-driven implosion of clouds, using x rays from a laser-irradiated, thin, gold foil as a surrogate star and a carbon-foam sphere as a surrogate cloud. An optically thick system, theoretically corresponding to a star-forming regime, was selected by choice of the foam density. Gold foil and sphere motions were imaged by x-ray radiography. Radiographic images show the formation of an interface between rarefied gold and carbon plasmas, a shock moving into the sphere, and a blunting of the initial sphere's shape. Measurements show that the shock moved linearly around 64 μm/ns into the sphere, and the gold–carbon interface formed by 2 ns at the sphere edge remained stationary. The deformation of the sphere was driven by the incident radiation and not by mechanical pressures applied by gold plasma. The blunting of the sphere was likely due to the geometric reduction of flux near the sphere's poles. Higher x-ray flux near the sphere's equator caused high compression and a faster shock, which flattened the sphere. We will discuss the results and implications of our observations.
Comparison and calibration of dose delivered by 137 Cs and x-ray irradiators in mice
Objective. The Office of Radiological Security, U.S. Department of Energy's National Nuclear Security Administration, is implementing a radiological risk reduction program which seeks to minimize or eliminate the use of high activity radiological sources, including 137 Cs, by replacing them with non-radioisotopic technologies, such as x-ray irradiators. The main goal of this paper is to evaluate the equivalence of the dose delivered by gamma- and x-ray irradiators in mice using experimental measurements and Monte Carlo simulations. We also propose a novel biophantom as an in situ dose calibration method. Approach. We irradiated mouse carcasses and 3D-printed mouse biophantoms in a 137 Cs irradiator (Mark I-68) and an x-ray irradiator (X-Rad320) at three voltages (160 kVp, 225 kVp and 320 kVp) and measured the delivered radiation dose. A Geant4-based Monte Carlo model was developed and validated to provide a comprehensive picture of gamma- and x-ray irradiation in mice. Main Results. Our Monte Carlo model predicts a uniform dose delivered in soft-tissue for all the explored irradiation programs and in agreement with the absolute dose measurements. Our Monte Carlo model shows an energy-dependent difference between dose in bone and in soft tissue that decreases as photon energy increases. Dose rate depends on irradiator and photon energy. We observed a deviation of the measured dose from the target value of up to –9% for the Mark I-68, and up to 35% for the X-Rad320. The dose measured in the 3D-printed phantoms are equivalent to that in the carcasses within 6% uncertainty. Significance. Our results suggest that 320 kVp irradiation is a good candidate to substitute 137 Cs irradiation barring a few caveats. There is a significant difference between measured and targeted doses for x-ray irradiation that suggests a strong need for in situ calibration, which can be achieved with 3D-printed mouse biophantoms. A dose correction is necessary for bone doses, which can be provided by a Monte Carlo calculation. Lastly, the biological implications of the differences in dose rates and dose per photon for the different irradiation methods should be carefully assessed for each small-animal irradiation experiment.
A Compact Superconducting RF Accelerator for Electron Beam and X-ray Irradiation
As commercial and industrial applications of electron beam and x-ray irradiation have developed, new applications have emerged that require very high beam power to create the required radiation field. These new applications require dependable, efficient, high-energy, high-power electron accelerators. Recent developments in Superconducting Radio-Frequency (SRF) technology can now enable accelerators with lower costs and improved performance. Cryogenic heat loads are dramatically reduced through use of new materials and improved component designs. New cooling methods allow the replacement of complex systems requiring cryogenic fluids with simple robust systems with no fluids. New RF sources can greatly reduce the cost of RF power. Each of these developments has been individually proven and an effort is underway at the Illinois Accelerator Research Center at Fermilab to integrate them into the first prototype of an entirely new class of industrial SRF-based accelerators. These accelerators will enable robust, turn-key operation with very high electrical efficiency. The accelerator prototype under design will be capable of 10 MeV beam, CW operation, and 250 kW of electron beam power. These modular systems are small enough to be palletized and transported to the point of use. Their high electrical efficiency mean that portable power generation systems can be enable their use in mobile applications. The goal is a compact, cost-effective, high-power accelerator suitable for many of the applications covered by this conference. Fermilab is actively working to build the prototype. The end-product will be a commercially available, robust, turn-key system for applications requiring reliable electron beam or X-ray irradiation. Keywords: accelerator, applications, conduction-cooling, cryogen-free, industrial, super-conducting RF.
Gamma and x-ray irradiation effects on different Ge and Ge/F doped optical fibers
We performed electron paramagnetic resonance (EPR) measurements on γ and X ray irradiated Ge doped and Ge/F co-doped optical fibers. We considered three different drawing conditions (speed and tension), and for each type of drawing, we studied Ge and Ge/F doped samples having Ge doping level above 4% by weight. The EPR data recorded for the γ ray irradiated fibers confirm that all the samples exhibit a very close radiation response regardless of the drawing conditions corresponding to values used for the production of specialty fibers. Furthermore, as for the X irradiated materials, in the γ ray irradiated F co-doped fibers, we observed that the Ge(1) and the Ge(2) defects generation is unchanged, whereas it was enhanced for the E'Ge. In the various fibers, the comparison of the γ and X-ray induced concentrations of these kinds of Ge related defects indicates that the two irradiations induce similar effects regardless of the different employed dose rates and sources. Confocal microscopy luminescence results show that the starting content of the Germanium Lone Pair Center (GLPC) is neither strongly affected by the Ge content nor by the drawing conditions, and we consider the similarity of the GLPC content as key factor in determining many of the above reported similarities.
Origin of a Raman scattering peak generated in single-walled carbon nanotubes by X-ray irradiation and subsequent thermal annealing
We have found that a Raman scattering (RS) peak around 1870 cm{sup −1} was produced by the annealing of the X-ray irradiated film of single-walled carbon nanotubes (SWNTs) at 450 {sup o}C. The intensity of 1870-cm{sup −1} peak showed a maximum at the probe energy of 2.3 eV for the RS spectroscopy with various probe lasers. Both the peak position and the probe-energy dependence were almost identical to those of the one-dimensional carbon chains previously reported in multi-walled carbon nanotubes. Consequently, we concluded that the 1870-cm{sup −1} peak found in the present study is attributed to carbon chains. The formation of carbon chains by the annealing at temperature lower than 500 {sup o}C is firstly reported by the present study. The carbon chains would be formed by aggregation of the interstitial carbons, which are formed as a counterpart of carbon vacancies by X-ray irradiation diffused on SWNT walls. The result indicates that the combination of X-ray irradiation and subsequent thermal annealing is a feasible tool for generating new nanostructures in SWNT.
Irreversible metal-insulator transition in thin film VO 2 induced by soft X-ray irradiation
In this study, we show the ability of soft x-ray irradiation to induce room temperature metal-insulator transitions (MITs) in VO 2 thin films grown on R-plane sapphire. The ability of soft x-rays to induce MIT in VO 2 thin films is confirmed by photoemission spectroscopy and soft x-ray spectroscopy measurements. When irradiation was discontinued, the systems do not return to the insulating phase. Analysis of valence band photoemission spectra revealed that the density of states (DOSs) of the V 3d band increased with irradiation time, while the DOS of the O 2p band decreased. We use these results to propose a model in which the MIT is driven by oxygen desorption from thin films during irradiation. As a strongly correlated transition metal oxide, VO 2 is an interesting and valuable material both for expanding our understanding of fundamental physics and for potential applications due to its particular metal-insulator transition (MIT). At 340 K, the resistance of bulk VO 2 exhibits a large jump (up to 5 orders of magnitude), accompanied by first order crystal phase transition from a room temperature monoclinic phase to a high temperature tetragonal phase.1,2 The origin of the MIT has been widely discussed since electron–phonon interaction (Peierls type) or electron–electron interaction (Mott–Hubbard type) could play a key role in inducing the occurrence of the MIT.3–7 Furthermore, these characteristics of the VO 2 .
The Dependence of the Mutagenic Effect on the Dose of X-Ray Irradiation in an In Vivo Experiment on Female (CBA×C57Bl/6)F1 Mice
We studied the mutagenic effect of X-ray irradiation in doses of 0.5, 1, and 1.5 Gy on female (CBA×C57Bl/6)F1 mice. The mutagenic effect (assessed by the parameter “frequency of bone marrow polychromatophilic erythrocytes with micronuclei”) linearly depended on the dose of X-ray irradiation in the range of up to 1 Gy and reached the plateau at 1.5 Gy. The fraction of polychromatophilic erythrocytes was 45, 45, and 46% under control conditions (without exposure) and exposure to the irradiation in the doses of 0.5 and 1 Gy, respectively. Irradiation in a dose of 1.5 Gy induced a slight inhibition of erythropoiesis. These data confirm the hypothesis on possible death of highly aberrant erythrocyte precursors after irradiation in high doses.
SOFT X-RAY IRRADIATION OF SILICATES: IMPLICATIONS FOR DUST EVOLUTION IN PROTOPLANETARY DISKS
The processing of energetic photons on bare silicate grains was simulated experimentally on silicate films submitted to soft X-rays of energies up to 1.25 keV. The silicate material was prepared by means of a microwave assisted sol–gel technique. Its chemical composition reflects the Mg{sub 2}SiO{sub 4} stoichiometry with residual impurities due to the synthesis method. The experiments were performed using the spherical grating monochromator beamline at the National Synchrotron Radiation Research Center in Taiwan. We found that soft X-ray irradiation induces structural changes that can be interpreted as an amorphization of the processed silicate material. The present results may have relevant implications in the evolution of silicate materials in X-ray-irradiated protoplanetary disks.
The Future of X-ray Irradiation: Addressing Supply Chain Risks and Opportunities (UUR Edition)
This study supports the Office of Radiological Security’s (ORS) mission of eliminating cesium irradiators by analyzing the supply chain for self-shielded X-ray irradiators (SSXIs), identifying potential risks, and proposing mitigation measures. The research focuses on the primary components of SSXIs, including X-ray tubes, controllers, generators, and coolers or chillers, and evaluates their vulnerabilities using a comprehensive risk matrix framework. The methodology includes subject matter expert (SME) interviews with relevant manufacturers and major stakeholders, a deep literature review, and a meta-analysis of maintenance reports provided by SSXI end users. Results show that while the SSXI market is small, it’s growing, and the highly global nature of the supply chain may create vulnerabilities for critical SSXI components (X-ray tubes are the most vulnerable, followed by generators and controllers). This research communicates necessary information to address concerns of current and future end users, especially those interested in transitioning away from radioactive sources, and informs future policy aimed at supporting the irradiation industry.
Intense Reactivity in Sulfur–Hydrogen Mixtures at High Pressure under X-ray Irradiation
Superconductivity near room temperature in the sulfur–hydrogen system arises from a sequence of reactions at high pressures, with X-ray diffraction experiments playing a central role in understanding these chemical–structural transformations and the corresponding S:H stoichiometry. Here we document X-ray irradiation acting as both a probe and as a driver of chemical reaction in this dense hydride system. We observe a reaction between molecular hydrogen (H 2 ) and elemental sulfur (S 8 ) under high pressure, induced directly by X-ray illumination, at photon energies of 12 keV using a free electron laser. The rapid synthesis of hydrogen sulfide (H 2 S) at 0.3 GPa was confirmed by optical observations, spectroscopic measurements, and microstructural changes detected by X-ray diffraction. These results document X-ray induced chemical synthesis of superconductor-forming dense hydrides, revealing an alternative production strategy and confirming the disruptive nature of X-ray exposure in studies on high-pressure hydrogen chalcogenides, from water to high-temperature superconductors.
Thermomechanical response of thickly tamped targets and diamond anvil cells under pulsed hard x-ray irradiation
In the laboratory study of extreme conditions of temperature and density, the exposure of matter to high intensity radiation sources has been of central importance. Here, we interrogate the performance of multi-layered targets in experiments involving high intensity, hard x-ray irradiation, motivated by the advent of extremely high brightness hard x-ray sources, such as free electron lasers and 4th-generation synchrotron facilities. Intense hard x-ray beams can deliver significant energy in targets having thick x-ray transparent layers (tampers) around samples of interest for the study of novel states of matter and materials’ dynamics. Heated-state lifetimes in such targets can approach the microsecond level, regardless of radiation pulse duration, enabling the exploration of conditions of local thermal and thermodynamic equilibrium at extreme temperature in solid density matter. The thermal and mechanical responses of such thick layered targets following x-ray heating, including hydrodynamic relaxation and heat flow on picosecond to millisecond timescales, are modeled using radiation hydrocode simulation, finite element analysis, and thermodynamic calculations. Assessing the potential for target survival over one or more exposures and resistance to damage arising from heating and resulting mechanical stresses, this study doubles as an investigation into the performance of diamond anvil high pressure cells under high x-ray fluences. Long used in conjunction with synchrotron x-ray radiation and high power optical lasers, the strong confinement afforded by such cells suggests novel applications at emerging high intensity x-ray facilities and new routes to studying thermodynamic equilibrium states of warm, very dense matter.
Effect of X-ray Irradiation and Carnauba Wax Coating on Quality of Lime (Citrus latifolia Tan.) Fruit
The quality of Persian (Tahiti) lime (Citrus latifoliaTan.) fruit was determined following coating with carnauba wax and X-ray irradiation at doses suitable for disinfestation of quarantine pests. Fruit with or without carnauba wax coating were treated with irradiation doses of 0, 150, 300, or 450 Gy, and stored for 14 days at 13 °C and 6 days at 20 °C to simulate commercial transportation and marketing conditions from Hawaii to the continental United States. The fruit color, weight loss, total soluble solids (TSS) content, and titratable acidity (TA) were analyzed at 7, 14, and 14 + 6 days post irradiation. Wax coating significantly delayed fruit peel discoloration, and reduced fruit weight loss by more than 7% compared with the unwaxed controls. Irradiation did not affectΔEof the peel for coated fruit at day 14 + 6. Irradiation with or without coating did not affectΔEof flesh color, weight loss, TSS content, or TA. Wax coating combined with irradiation treatment of limes at doses ≤450 Gy ensured marketable visual quality and chemical composition while providing quarantine security.
Effect of Auger recombination on transient optical properties in XUV and soft X-ray irradiated silicon nitride
Spatially encoded measurements of transient optical transmissivity became a standard tool for temporal diagnostics of free-electron-laser (FEL) pulses, as well as for the arrival time measurements in X-ray pump and optical probe experiments. The modern experimental techniques can measure changes in optical coefficients with a temporal resolution better than 10 fs. This, in an ideal case, would imply a similar resolution for the temporal pulse properties and the arrival time jitter between the FEL and optical laser pulses. However, carrier transport within the material and out of its surface, as well as carrier recombination may, in addition, significantly decrease the number of carriers. This would strongly affect the transient optical properties, making the diagnostic measurement inaccurate. Below we analyze in detail the effects of those processes on the optical properties of XUV and soft X-ray irradiated Si 3 N 4 , on sub-picosecond timescales. Si 3 N 4 is a wide-gap insulating material widely used for FEL pulse diagnostics. Theoretical predictions are compared with the published results of two experiments at FERMI and LCLS facilities, and with our own recent measurement. The comparison indicates that three body Auger recombination strongly affects the optical response of Si 3 N 4 after its collisional ionization stops. By deconvolving the contribution of Auger recombination, in future applications one could regain a high temporal resolution for the reconstruction of the FEL pulse properties measured with a Si 3 N 4 -based diagnostics tool.
Survival fraction and phenotype alterations of Xenopus laevis embryos at 3 Gy, 150 kV X-ray irradiation
To determine the radiosensitivity of Xenopus laevis embryos, aquatic organism model, for toxicity studies utilizing X-rays at acute high dose levels, by analysing its survival fraction and phenotype alterations under one-exposure integral dose. We used the standard Frog Embryo Teratogenesis Assay Xenopus test during the early stages of X. laevis development. The embryos were harvested until st. 46 when they were irradiated. The radiation effects were checked daily for a week and the survival, malformations and growth inhibition were assessed. Sibling tadpoles as control organisms were used. Statistical analysis was performed to assess the extent of any damage. Irradiation was performed with an X-ray tube operated at 150 kV. The tube containing the tadpoles was exposed to an air kerma of 3 Gy as measured in air with an in-beam ionization chamber. After one week, survival fraction of irradiated embryos was 58%, while for control embryos it was 81%. Hence, irradiation with 150 kV, 3 Gy X-rays produced a 23% decrease of survival in regard to unirradiated embryos. The 70% of the irradiated embryos showed an altered distribution of the skin pigmentation, in particular on the dorsal area and in the olfactory pits, where the pigment concentration increased by a factor 2. In conclusion exposure of X. laevis to 3 Gy, 150 kV X-rays induced a reduction of embryos survival and a significant modification of pigmentation. The authors think that X. laevis embryos, at st 46, is a suitable biological model for large scale investigations on the effects of ionizing radiation.
Sterile Insect X-ray Irradiator, Phase I Final Report
Explore the source record for details and available documents.
Compatibility of ethylene vinyl acetate (EVA)/ethylene vinyl alcohol (EVOH)/EVA films with gamma, electron-beam, and X-ray irradiation
Many polymer-based medical devices are sterilized by gamma irradiation. To reduce the use of cobalt-60 gamma-ray sources, transition from gamma ray to alternative irradiation technologies was proposed, namely electron beam (e-beam) and X-ray. A major impediment for such a transition is the knowledge gap in material compatibility with the different radiation sources. In this study, multi-layer films consisting of ethylene vinyl acetate (EVA) and ethylene vinyl alcohol (EVOH) components were irradiated to target doses of 30, 45, and 60 kGy by gamma-ray, e-beam, and X-ray sources. Effects of irradiation were evaluated on 12 material properties, and statistical comparisons between gamma irradiation and alternative technologies were conducted using the two one-sided t-test (or “equivalence test”) and classic t-test. Melting temperature and UV absorbance below 300 nm showed dose dependencies, while other investigated properties such as discoloration and mechanical durability did not change with dose up to 60 kGy. Based on these results, there is no material compatibility issue associated with the transition from gamma to e-beam or to X-ray as source of sterilization radiation of the studied multi-layer film.
Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers
There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.