Absolute Calibration and Use of a Soft X-ray Source of Characteristic Carbon Radiation
Measurement of absolute photon yield of carbon K radiation produced by electron bombardment for calibration of grazing incidence grating spectrometer
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Measurement of absolute photon yield of carbon K radiation produced by electron bombardment for calibration of grazing incidence grating spectrometer
Cosmic X-ray sources in Scorpius and Sagittarius detected by rocket flights
Bremsstrahlung nature of X-ray emission from discrete sources
Scorpio X-ray source as supernova remnant at 30 light years with steep electron spectrum compared to one in remnants at radio frequencies
Hydrazine and 1,1-dimethylhydrazine were radiolyzed at room temperature by using about 1 gram of liquid or 1/2 to 2 liters of vapor at room-temperature vapor pressure. A tungsten-target X-ray source operating at 300 kilovolts and 6 to 8 milliamperes (0.1 to 1.0 A) was used at intensities of 1 times 10 (sup 2) to 1 times 10 (sup 3) roentgens per minute to give total doses of 4.1 rads to 2.3 times 10 (sup 6) rads. The amounts of decomposition were dependent on total dose and independent of dose rate. In the case of hydrazine vapor, the decomposition was also directly related to surface area. There was a lesser surface effect with liquid hydrazine, but this variable was not studied for 1,1-dimethylhydrazine. The order of decreasing sensitivity to X-radiation is as follows: hydrazine vapor, 1,1-dimethylhydrazine vapor, 1,1-dimethylhydrazine liquid, and hydrazine liquid. The decomposition products of hydrazine were nitrogen, hydrogen, ammonia, and unidentified products. The same products plus methylamine, dimethylamine, and hydrazine were found from the decomposition of 1,1-dimethylhydrazine. In addition, the 1,1-dimethylhydrazine underwent post-irradiation changes. Values for G (number of molecules of sample decomposed per 100 electronvolts of absorbed energy) of the order of 10 (sup 6) suggest that the vapor-phase decompositions are chain reactions.
Soft X-ray emission from the X-ray source Per X-1 was observed in the 0.4-2 keV energy interval from a rocket-borne X-ray detector. Spectral analysis of the data indicates that in the 0.4-2 keV band the X-ray emission from Per X-1 can be fitted either with a power law or a steep thermal bremsstrahlung spectrum. This steep spectrum is inconsistent with the spectrum measured above 2 keV. The measured flux in 0.4-2 keV band corresponds to X-ray luminosity of 3 times 10 to the 45th ergs per second for Per X-1.
X-ray emission by radio wave sources of outer space
Technical data, and experiment and spacecraft alternatives are presented in support of the HEAO-C, whose primary objective is a detailed study of the more interesting high energy sources, using grazing incidence X-ray telescopes and a spacecraft pointing accuracy of + or - 1 arc minute. The analyses presented cover the mission analysis and launch vehicle; thermal control trade studies and supporting analyses; attitude sensing and control analyses; electrical systems; and reliability analysis. The alternate experiments which were considered are listed, and the advantages and disadvantages of several alternate observatory configurations are assessed.
The SuperHERO hard X-ray telescope will observe extended sources at unprecedented imaging resolution, revealing the origins of non-thermal emission in extreme astrophysical environments. Employing NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon platform, SuperHERO consists of seven identical, co-aligned telescopes with a combined effective area of 45 cm² at 30 keV. SuperHERO was selected in the APRA 2023 call as a five-year mission, with an inaugural two-day flight scheduled from Fort Sumner, New Mexico, in the fall of 2028. For its initial target, SuperHERO will observe the Crab pulsar wind nebula, localizing hard X-ray emission. Mission development is currently underway, with updates and status to be provided in this presentation.
X-ray polarimetry is a new tool capable of probing the geometry of accretion onto weakly magnetized neutron stars. Here we present the first X-ray spectro-polarimetric results from coordinated observations of the atoll source 4U 1735−44, conducted with the Imaging X-ray Polarimetry Explorer (IXPE), NICER, and NuSTAR . Over the 2–8 keV energy range, we obtained a marginal detection of polarization with the polarization degree of 1.4% ± 0.7% and polarization angle of −29◦ ± 14◦, corresponding to a 3σ upper limit on the polarization degree of 3.5%. The best-fit model to describe the spectrum comprises a thermal component associated with the accretion disk, a Comptonized black body component, and a relativistic reflection component. From the reflection model, we infer a disk inclination of ∼40◦. The spectroscopic and polarimetric properties of 4U 1735−44 are consistent with those observed in other atoll sources studied by IXPE, with its low polarization likely due to its low inclination
IXPE has provided for the first time detailed energy- and time-resolved X-ray polarimetry of Z-type neutron star low-mass X-ray binaries (NS-LMXBs) as they move along their color-color diagrams (CCDs). These sources can reach the highest polarization observed for NS-LXMBs in the 2–8 keV range when they move along the horizontal branch. In a previous paper, we characterized the spectral state of a sample of Z-sources using the CCD and estimated the polarization with model-independent analysis. Here, we present detailed spectropolarimetric analysis for each source on each branch using data from IXPE, NICER, and NuSTAR. The continuum X-ray emission of all the sources is well described with a combination of thermal accretion disk emission plus a harder Comptonized component. In addition, reflection features, in particular the relativistically broadened Fe Kα line, are observed for our sources, except GX 5–1. For most of the sources and branches, the main contribution to the X-ray emission and polarization is due to Comptonization: moving from the horizontal branch (HB) to the normal branch (NB), the polarization degree (PD) in the 2–8 keV band varies from about 6% to 3–4%, while the PD is loosely constrained in the flaring branch (FB), due to the shorter exposures. These PD values are significantly higher than theoretical expectations for typical spreading or boundary layer configurations. The polarization of the disk is generally lower (below 3%) but still higher than predictions for an electron scattering-dominated, plane-parallel atmosphere above the disk observed at the corresponding inclination. Moreover, the polarization angle (PA) of the disk seems to be significantly misaligned and not perpendicular to that of Comptonization. We find no correlation between the polarization signal and the inclination, nor with the contribution of reflected photons throughout the Z-track.
Calculation of spectral line intensity produced by concave grating with given monochromatic radiant power source
Directional air samplers, used for resolving suspended particulate matter on the basis of time and wind direction were used to assess the feasibility of characterizing and identifying emission source types in urban multisource environments. Filters were evaluated for 16 elements and X-ray fluorescence methods yielded elemental concentrations for direction, day, and the interaction of direction and day. Large numbers of samples are necessary to compensate for large day-to-day variations caused by wind perturbations and/or source changes.
Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.
Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.
High-energy X-ray observations have transformed our understanding of astrophysical systems where non-thermal processes dominate, from shock-accelerated particles in supernova remnants to relativistic jets and hot coronae in active galactic nuclei. NuSTAR’s pioneering focusing images of the hard X-ray sky have demonstrated the immense scientific potential of this band, while also highlighting how limited angular resolution constrains our ability to fully characterize complex physical processes in faint extended sources and resolving faint sources in crowded sky regions. In this presentation, I will discuss a pathway to overcome these challenges through NASA Marshall Space Flight Center’s replicated NiCo full-shell X-ray mirror technology. Specifically, I will discuss the SuperHERO hard X-ray telescope to achieve better than 10-arcsecond half-power diameter (HPD) angular resolution on a balloon flight observing the Crab Nebula, and the High EneRgy Observatory for Imaging X-rays (HEROIX) Medium-Class Mission concept to achieve an integrated effective area of 570 cm2 at 30 keV with 5 arcsec HPD angular resolution.