Search NASASearch

SEARCH · Search NASA

Results for “X-Y PLOTTER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Oscilloscope used as X-Y plotter or two-dimensional analyzer

Oscilloscope used as an X-Y plotter or two-dimensional analyzer tags each point with a yes or no, depending on a third parameter. The usual square-wave pulse is replaced on the scope by a single information-bearing dot which lengthens to a dash in response to a simultaneous event.

Hansen, D.

X-Y plotter adapter developed for SDS-930 computer

Graphical Display Adapter provides a real time display for digital computerized experiments. This display uses a memory oscilloscope which records a single trace until erased. It is a small hardware unit which interfaces with the J-box feature of the SDS-930 computer to either an X-Y plotter or a memory oscilloscope.

Robertson, J. B.

Single parameter testing

Frequency response testing of ac and dc amplifiers, and single parameter testing of X-Y PLOTTER

FREQUENCY RESPONSE

System remotely inspects, measures, and records internal irregularities in piping

Video electromechanical probe visually inspects and measures internal offset and peaking of welds in relatively large piping. Irregularity dimensions are recorded on peripheral equipment consisting of video tape and X-Y plotter. The probe is used for inspection of vacuum-jacketed liquid lines that cannot be inspected externally.

Burry, F. H.

Automated plotting of equipotentials

By substitution of resistance paper for normal plotting paper, an x-y plotter can be used to draw automatically the equipotential lines between components represented in planar form on the paper. This technique is used for high voltage electronic components of complex configuration for the prediction of stress in the intervening insulation.

Bunker, E. R., Jr.

Direct determination of lead-210 by liquid-scintillation counting

Soft betas, the internal conversion electrons, and unconverted gamma rays from lead-210 are efficiently detected in a liquid scintillation counting system with efficiency of 97 percent. The counter is interfaced with a multichannel pulse height analyzer. The spectra obtained is stored on paper tape and plotted on an x-y plotter.

Fairman, W. D.

HYDES: A generalized hybrid computer program for studying turbojet or turbofan engine dynamics

This report describes HYDES, a hybrid computer program capable of simulating one-spool turbojet, two-spool turbojet, or two-spool turbofan engine dynamics. HYDES is also capable of simulating two- or three-stream turbofans with or without mixing of the exhaust streams. The program is intended to reduce the time required for implementing dynamic engine simulations. HYDES was developed for running on the Lewis Research Center's Electronic Associates (EAI) 690 Hybrid Computing System and satisfies the 16384-word core-size and hybrid-interface limits of that machine. The program could be modified for running on other computing systems. The use of HYDES to simulate a single-spool turbojet and a two-spool, two-stream turbofan engine is demonstrated. The form of the required input data is shown and samples of output listings (teletype) and transient plots (x-y plotter) are provided. HYDES is shown to be capable of performing both steady-state design and off-design analyses and transient analyses.

Szuch, J. R.

Engineering simulation development and evaluation of the two-segment noise abatement approach conducted in the B-727-222 flight simulator

Profile modification as a means of reducing ground level noise from jet aircraft in the landing approach is evaluated. A flight simulator was modified to incorporate the cockpit hardware which would be in the prototype airplane installation. The two-segment system operational and aircraft interface logic was accurately emulated in software. Programs were developed to permit data to be recorded in real time on the line printer, a 14-channel oscillograph, and an x-y plotter. The two-segment profile and procedures which were developed are described with emphasis on operational concepts and constraints. The two-segment system operational logic and the flight simulator capabilities are described. The findings influenced the ultimate system design and aircraft interface.

Nylen, W. E.

Graphic-to-digital conversion system

Computer-controlled system allows operator to record only those data points selected. It consists of commercially available X-Y plotter, computer, and A/D and D/A converters. New component is strain gage controller and amplifier which can be adapted to existing systems.

Rosenthal, F. L.

Particle parameter analyzing system

An X-Y plotter circuit apparatus is described which displays an input pulse representing particle parameter information, that would ordinarily appear on the screen of an oscilloscope as a rectangular pulse, as a single dot positioned on the screen where the upper right hand corner of the input pulse would have appeared. If another event occurs, and it is desired to display this event, the apparatus is provided to replace the dot with a short horizontal line.

Hansen, D. O.

Design specification for a general purpose Data Integration and Display System (DIDS)

The capability for any program written in FORTRAN or XSYMBOL to display its output is provided. Displays are presented on the Biomed Console CRT, the COMPLOT X-Y plotter or both. The display of data stored on magnetic tape is accomplished without the necessity of coding a program. The keyboard on the Biomed Console or the teletype was designed to be the user's interface with DIDS to call displays stored on magnetic tape.

Source record

New Apparatus Tests Pressure-Suit Joints

New apparatus measures applied torque and angle-of-flexure in pressurized flexible joints, such as those found in diving suits and flight suits. Torque and flexure are permanently recorded on x-y plotter. Family of curves can be taken as function of suit pressure or other variables. Apparatus could also measure torque-versus-angle in mechanical linkages.

Vykukal, H. C.

A microcomputer-based system for noise characteristics analysis

A description is given of the design and use of a microcomputer-based system for the analysis and prediction of interior noise levels in general aviation aircraft constructed from novel materials. The system consists of a test chamber divided into two parts by a panel which has been fabricated from the material or combination of materials to be tested. A noise generator applies noise to one side of the specimen, while the microcomputer system measures and records the noise spectra on both sides of the specimen, so that its attenuation properties may be calculated and displayed by both a color CRT and X-Y plotter hard copy.

Mosser, M. A.

Method for compression testing of composite materials at high strain rates

A method is presented for testing composite materials in compression at strain rates up to approximately 500 per s. The method uses a thin ring specimen (4 in. in diameter, 1 in. wide, six-eight plies thick) loaded dynamically by an external pressure pulse applied explosively through a liquid. Strains in the specimen and in a steel calibration ring are recoorded with a digital processing oscilloscope. Results are plotted by an x-y plotter in the form of a dynamic stress-strain curve. Data analysis is based on a numerical solution of the equation of motion. A computer program is used which involves smoothing and approximation of the strain magnitude, strain rate, and strain acceleration. Dynamic stress-strain curves obtained for 0-deg and 90-deg specimens of two graphite/epoxy composites are presented.

Daniel, I. M.

Pulse-Width-to-Analog-Voltage Converter

Peak output voltage varies linearly with input-pulse duration. Circuit converts pulses of varying widths (as from sound-velocity instrumentation or tachometers) into analog voltages. Peak voltage increases in proportion to pulse width. Voltage used to drive an x-y plotter or storage oscilloscope. Pulse-width-to-voltage converter has peak output voltage that varies with duration of input pulses.

Sosack, G. S.