Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray & gamma ray plasma measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Energy Flow in Thin Shell Implosions and Explosions

Energy flow and balance in convergent systems beyond petapascal energy densities controls the fate of late-stage stars and the potential for controlling thermonuclear inertial fusion ignition. Time-resolved x-ray self-emission imaging combined with a Bayesian inference analysis is used to describe the energy flow and the potential information stored in the rebounding spherical shock at 0.22 PPa (2.2 Gbar or billions of atmospheres pressure). This analysis, together with a simple mechanical model, describes the trajectory of the shell and the time history of the pressure at the fuel-shell interface, ablation pressure, and energy partitioning including kinetic energy of the shell and internal energy of the fuel. Here, the techniques used here provide a fully self-consistent uncertainty analysis of integrated implosion data, a thermodynamic-path independent measurement of pressure in the petapascal range, and can be used to deduce the energy ow in a wide variety of implosion systems to petapascal energy densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of turbulent velocity and bounds for thermal diffusivity in laser shock compressed foams by x-ray photon correlation spectroscopy

Experimental benchmarking of transport coefficients under extreme conditions is required for validation of differing theoretical models. To date, measurement of transport properties of dynamically compressed samples remains a challenge with only a limited number of studies able to quantify transport in high pressure and temperature matter. x-ray photon correlation spectroscopy utilizes coherent x-ray sources to measure time correlations of density fluctuations, thus providing measurements of length and timescale-dependent transport properties. Here, we present a first-of-a-kind experiment to conduct x-ray photon correlation spectroscopy in laser shock compression experiments. We report measurement of the turbulent velocity in the wake of a laser driven supersonic shock and place an upper bound on thermal diffusivity in a solid density plasma on nanosecond timescales.

High-energy-density plasmas↗

Direct Experimental Proof of the Principal Role of Reduced High-Mode Hydrodynamic Mix in Recent Ignition Success on NIF

This Letter details the role of reduced hydrodynamic mix in achieving the first fusion plasma to satisfy the Lawson criterion for ignition. Using novel 3D measurements of the temperature and density of the burning deuterium-tritium plasma across a series of experiments, we demonstrate that hydrodynamic mixing from small-scale capsule defects was a key degradation mechanism inhibiting ignition. A series of five layered deuterium-tritium experiments using 1.9 MJ of laser energy demonstrates a 2 × reduction of the thermonuclear yield when a lower quality capsule, typical of preignition experiments, is used. Radiation hydrodynamic calculations consistent with the observed mix profile show that the mixed fuel’s reduced compression and increased radiative loss explain the yield reduction. Furthermore, a hydroscaling argument suggests that a ∼ 3 MJ laser would be needed to reach ignition with such a capsule, well beyond the current capabilities of high energy laser systems. As such, this Letter gives critical insight into the physics of mix in self-heated fusion plasmas and establishes a foundation to evaluate capsule quality needs of future inertial fusion designs that aim at ignition and high gain.

High-energy-density plasmas↗

Predicted performance of a tangential viewing hard x-ray camera for the DIII-D high field side lower hybrid current drive experiment

High field side launch of lower hybrid current drive (LHCD) has improved accessibility and penetration over low field side launch on DIII-D. Simulations predict single pass absorption under a wide range of plasma conditions. Hard x-ray (HXR) measurement of LHCD generated fast electron bremsstrahlung (50–250 keV) will validate wave propagation and absorption. Emissivity profiles are recovered from one-dimensional inversion of HXR brightness to determine LH damping location, fast electron slowing down time, and some indication of the fast electron energy. The camera will be implemented by populating 32 tangential sightlines of the existing Gamma Ray Imager with Kromek SPEARTM Cadmium Zinc Telluride (CZT) detectors sensitive to 10–1000 keV photons with 10 keV energy resolution. Expected count rates allow for <0.5 ms time resolution. Pulses are processed using 50 ns shaping time Cremat CR-200 Gaussian shaping modules and are digitized by 25 MHz D-TACQ ACQ216 digitizers. The performance of the HXR camera is evaluated by comparing predicted fast electron density profiles and inverted synthetic brightnesses obtained from the ray-tracing/Fokker–Planck codes GENRAY/CQL3D. Inversions closely matched predicted fast electron profiles for a range of experimental parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-pulse time resolved gamma ray spectroscopy of the advanced radiographic capability using gas Cherenkov diagnostics

The advanced radiographic capability located at the National Ignition Facility (NIF) uses high intensity, short pulse lasers to create bright photon sources for diagnosing high energy density experiments. There are radiographic needs for a multi-frame time-resolved MeV gamma diagnostic for experiments on the NIF with sub-nanosecond resolution. A series of experiments demonstrated measurements of MeV x-ray spectra resolved with a time separation of a few nanoseconds through the use of gas Cherenkov detectors. In this work, a two-pulse radiographic experiment found a 30% reduction in > 2.8 MeV photon flux compared to the first frame exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Characterization of sub-picosecond laser-produced fast electrons by modeling angularly resolved bremsstrahlung measurements with 3D hybrid particle-in-cell code

Hard x-rays produced by intense laser-produced fast electrons interacting with solids are a vital source for producing radiographs of high-density objects and implosion cores for inertial confinement fusion. Accurate calculation of hard x-ray sources requires a three-dimensional (3D) simulation geometry that fully models the electron transport dynamics, including electron recirculation and the generation of absolute photon yields. To date, 3D simulations of laser-produced bremsstrahlung photons over tens of picoseconds and code benchmarking have not been performed definitively. In this study, we characterize sub-picosecond laser-produced fast electrons by modeling angularly resolved bremsstrahlung measurements for refluxing and non-refluxing targets using the 3D hybrid particle-in-cell (PIC), Large Scale Plasma code. Bremsstrahlung radiation and escaped electron data were obtained by focusing a 50-TW Leopard laser (15 J, 0.35 ps, 2 × 10 19 W/cm 2 ) on a 100-μm-thick Cu foil and a Cu with a large plastic backing (Cu–CH target). Data for both the Cu and Cu–CH targets were reproduced for simulations with a given set of electron parameters. Comparison of the simulations revealed that the hard x-ray emission from the Cu target was significantly longer in duration than that from the Cu–CH target. Here, the benchmarked hybrid PIC code could prove to be a powerful tool in the design and optimization of time- and angular-dependent bremsstrahlung sources for flash x-ray and gamma-ray radiography.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Three-dimensional diagnostics and measurements of inertial confinement fusion plasmas

Recent inertial confinement fusion measurements have highlighted the importance of 3D asymmetry effects on implosion performance. One prominent example is the bulk drift velocity of the deuterium–tritium plasma undergoing fusion (“hotspot”), v HS . Upgrades to the National Ignition Facility neutron time-of-flight diagnostics now provide v HS to better than 1 part in 10 4 and enable cross correlations with other measurements. Here we present the impact of v HS on the neutron yield, downscatter ratio, apparent ion temperature, electron temperature, and 2D x-ray emission. The necessary improvements to diagnostic suites to take these measurements are also detailed. The benefits of using cross-diagnostic analysis to test hotspot models and theory are discussed, and cross-shot trends are shown.

47 OTHER INSTRUMENTATION↗

Foam-lined hohlraum, inertial confinement fusion experiments on the National Ignition Facility

Experiments on the National Ignition Facility (NIF) to study hohlraums lined with a 20-mg/cc 400-μm-thick Ta 2 O 5 aerogel at full scale (hohlraum diameter = 6.72 mm) are reported. Driven with a 1.6-MJ, 450-TW laser pulse, the performance of the foam liner is diagnosed using implosion hot-spot symmetry measurements of the high-density carbon (HDC) capsule and measurement of inner beam propagation through a thin-wall 8-μm Au window in the hohlraum. Results show an improved capsule performance due to laser energy deposition further inside the hohlraum, leading to a modest increase in x-ray drive and reduced preheat due to changes in the x-ray spectrum when the foam liner is included. In addition, the outer cone bubble uniformity is improved, but the predicted improvement in inner beam propagation to improve symmetry control is not realized for this foam thickness and density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Properties of the Prompt Optical Counterpart Arising from the Cooling of Electrons in Gamma-Ray Bursts

This work extends a contemporaneous effort to study the properties of the lower-energy counterpart synchrotron emission produced by the cooling of relativistic gamma-ray burst (GRB) electrons through radiation (synchrotron and self-Compton) emission and adiabatic losses. We derive the major characteristics (pulse duration, lag time after burst, and brightness relative to the burst) of the prompt optical counterpart (POC) occurring during or after the GRB. Depending on the magnetic field lifetime, duration of electron injection, and electron transit time Δt o from hard X-ray (GRB) to optical-emitting energies, a POC may appear during the GRB pulse (of duration δt γ ) or after (delayed OC). The signature of counterparts arising from the cooling of GRB electrons is that POC pulses (Δto < δtγ) last as long as the corresponding GRB pulse (δt o ≃ δt γ ), while delayed OC pulses (Δt o > δt γ ) last as long as the transit time (δt o ≃ Δt o ). If OC variability can be measured, then another signature for this OC mechanism is that the GRB variability is passed on to POCs but not to delayed OCs. Within the GRB electron cooling model for counterparts, POCs should be on average dimmer than delayed ones (consistent with the data), and harder GRB low-energy slopes β LE should be associated more often with the dimmer POCs. The latter sets an observational bias against detecting POCs from (the cooling of electrons in) GRBs with a hard slope β LE , making it more likely that the detected POCs of such bursts arise from another mechanism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional reconstruction of neutron, gamma-ray, and x-ray sources using a cylindrical-harmonics expansion

Inertial confinement fusion capsule implosions produce neutron, gamma-ray, and x-ray emission, which are recorded by a variety of detectors, both time integrated and time resolved, to determine the performance of the implosion. Further, two-dimensional emission images from multiple directions can now be combined to infer three-dimensional structures in the implosion, such as the distribution of thermonuclear fuel density, carbon ablator, and impurities. Because of the cost and complexity of the imaging systems, however, only a few measurements can be made, so reconstructions of the source must be made from a limited number of views. Here, a cylindrical-harmonics decomposition technique to reconstruct the three-dimensional object from two views in the same symmetry plane is presented. In the limit of zero order, this method recovers the Abel inversion method. The detailed algorithms used for this characterization and the resulting reconstructed neutron source from an experiment collected at the National Ignition Facility are presented.

47 OTHER INSTRUMENTATION↗

Spectral Hardness of X- and Gamma-Ray Emissions From Lightning Stepped and Dart Leaders

During the 2022 New Mexico monsoon season, we deployed two X-ray scintillation detectors, coupled with a 180 MHz data acquisition system to detect X-rays from natural lightning at the Langmuir Lab mountain-top facility, located at 3.3 km above mean sea level. Data acquisition was triggered by an electric field antenna calibrated to pick up lightning within a few km of the X-ray detectors. We report the energies of over 240 individual photons, ranging between 13 keV and 3.8 MeV, as registered by the LaBr3(Ce) scintillation detector. These detections were associated with four lightning flashes. Particularly, four-stepped leaders and seven dart leaders produced energetic radiation. Importantly, the reported photon energies allowed us to confirm that the X-ray energy distribution of natural stepped and dart leaders follows a power-law distribution with an exponent ranging between 1.09 and 1.96, with stepped leaders having a harder spectrum. Characterization of the associated leaders and return strokes was done with four different electric field sensing antennas, which can measure a wide range of time scales, from the static storm field to the fast change associated with dart leaders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The 2024 July 16 solar event: a challenge to the coronal mass ejection origin of long-duration gamma-ray flares

We present a multi-spacecraft analysis of the 2024 July 16 long-duration gamma-ray flare (LDGRF) detected by the Large Area Telescope on the Fermi satellite. The measured > 100 MeV γ-ray emission persisted for over seven hours after the flare impulsive phase, and was characterized by photon energies exceeding 1 GeV and a remarkably hard parent-proton spectrum. In contrast, the phenomena related to the coronal mass ejection (CME)-driven shock linked to this eruption were modest, suggesting an inefficient proton acceleration unlikely to achieve energies well above the 300 MeV pion-production threshold to account for the observed γ-ray emission. Specifically, the CME was relatively slow (∼600 km/s) and the accompanying interplanetary type-II/III radio bursts were faint and short-lived, unlike those typically detected during large events. In particular, the type-II emission did not extend to kilohertz frequencies and disappeared ∼5.5 hours prior to the LDGRF end time. Furthermore, the associated solar energetic particle (SEP) event was very weak, short-duration, and limited to a few tens of MeV, even at magnetically well-connected spacecraft. These findings demonstrate that a very fast CME resulting in a high-energy SEP event is not a necessary condition for the occurrence of LDGRFs, challenging the idea that the high-energy γ-ray emission is produced by the back-precipitation of shock-accelerated ions into the solar surface. The alternative origin scenario based on local particle trapping and acceleration in large-scale coronal loops is instead favored by the observation of giant arch-like structures of hot plasma over the source region that persisted for the entire duration of this LDGRF.

Sun: UV radiation↗

Optimization of the gamma reaction history diagnostic for double-shell pusher areal density and reaction history measurements on the National Ignition Facility

The double-shell inertial confinement fusion campaign, which consists of an aluminum ablator, a foam cushion, a high-Z pusher (tungsten or molybdenum), and liquid deuterium–tritium (DT) fuel, aims for its first DT filled implosions on the National Ignition Facility (NIF) in 2024. The high-Z, high density pusher does not allow x-rays to escape the double-shell capsule. Therefore, nuclear diagnostics such as the Gamma Reaction History (GRH) diagnostic on the NIF are crucial for understanding high-Z implosion performance. To optimize the GRH measurement of fusion reaction history and the pusher’s areal density, the MCNP6.3-based forward model of the detector was built. When calculating the neutron-induced inelastic gamma ray production, the interaction of neutrons with the compressed fuel was additionally included. By folding the calculated gamma ray spectrum output and the previously calibrated GRH detector responses, the optimum set of GRH energy thresholds for measuring the pusher areal density is determined to be 2.9 and 6.3 MeV for DT double-shell experiments. In addition, the effect of the down-scattering of neutrons on the gamma ray spectrum, the minimum required yield for measurements, and the attenuation of the gamma rays through the pusher are analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of drive pulse shape on graded metal pushered single shell capsule implosions on the National Ignition Facility

Graded metal pushered single shells (PSS) are a viable alternative to low-Z capsules (Z is the atomic number) for indirect drive inertial confinement fusion implosions due to enhanced core tamping and radiation trapping, but they can be compromised by the pusher mixing with the fuel. We compare 2-shock and 3-shock laser pulses for Be/Cr PSS capsules filled with deuterium–tritium gas fuel at 6 mg/cc density. 1D radiation-hydrodynamic simulations predict higher core compression and, hence, ∼2× higher fusion yield for the 3-shock drive than for 2-shock. Nevertheless, we observe similar core ion temperatures and fusion yields for both drives. The implosion burn duration is 25% shorter and the core volume is ∼2.5× smaller for the 3-shock drive than for 2-shock, consistent with a higher compression. 1D LASNEX mix simulations using a buoyancy-drag model matching the measured yields also agree with the observed core sizes and burn durations and suggest ∼40% and ∼70% yield degradations for 2-shock and 3-shock drives due to hydrodynamic instabilities and atomic mix at the pusher–fuel interface. At the same time, 2D HYDRA simulations show that mid-mode (2–250) instability degradations are negligible for the 2-shock implosion (9%) and significant (45%) for 3-shock. Subtracting these from the 1D mix simulations, we infer similar degradations from high-mode instabilities and atomic mix for both drives. Due to its robustness to mid-mode instabilities, future pusher–gas mix studies will use the 2-shock drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiscale and multidimensional modeling of particle acceleration and transport in solar flares

Multi-messenger, multi-viewpoint, and time-resolved observations of solar flares are now providing unprecedented constraints on particle acceleration sites, energy conversion, and energy transport. The interpretation of current observations, including microwave imaging spectroscopy from EOVSA, hard x-ray (HXR) imaging from Solar Orbiter/STIX, gamma-ray diagnostics from Fermi, and in situ measurements from Parker Solar Probe and Solar Orbiter, collectively demands modeling frameworks that go beyond traditional spatially unresolved, one-zone models or single-mechanism descriptions. This review surveys multiscale and multidimensional modeling approaches, including kinetic, magnetohydrodynamic (MHD), and macroscopic particle models, that are being developed to meet the need. Kinetic simulations reveal that three-dimensional (3D) effects, including field-line chaos and self-generated turbulence, are essential for sustained power-law particle acceleration. MHD simulations now capture flux-rope eruptions, plasmoid-unstable current sheets, and turbulent flare regions in realistic magnetic topologies. Macroscopic models coupling MHD with energetic-particle models produce spatially resolved electron distributions and synthetic HXR and microwave emissions for direct comparison with observations. Despite these advances, outstanding challenges remain in bridging kinetic and global scales, improving MHD simulations and macroscopic particle models, and achieving quantitative model-observation closure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Predicting hot electron generation in inertial confinement fusion with particle-in-cell simulations

A series of two-dimensional particle-in-cell simulations with speckled laser drivers was carried out to study hot electron generation in direct-drive inertial confinement fusion on OMEGA. Scaling laws were obtained for hot electron fraction and temperature as functions of laser/plasma conditions in the quarter-critical region. Using these scalings and conditions from hydro simulations, the temporal history of hot electron generation can be predicted. The scalings can be further improved to predict hard x-rays for a collection of OMEGA warm target implosions within experimental error bars. Furthermore, these scalings can be readily implemented into inertial confinement fusion design codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Density Measurement of NaCl-MgCl 2 -PuCl 3 and NaCl-UCl 3 -PuCl 3 Molten Salt Systems by Neutron Radiographic Dilatometry

A novel neutron radiographic technique was developed and implemented to measure the change in volume as a function of temperature of select plutonium-containing liquid chloride mixtures from melt to 1250 K. These measurements were performed at Los Alamos National Laboratory by members of the molten salt research group under support from Gateway for Accelerated Innovation in Nuclear (GAIN) voucher NE-21-25117: “Density Measurements of Plutonium Bearing Salts via Neutron Beam Dilatometry”. This technical report contains a description of the experimental method and a summary of the results. Initial characterization of the {NaCl, MgCl 2 , UCl 3 , PuCl 3 } salts used in this experiment includes a combination of x-ray diffraction, differential scanning calorimetry, gamma ray spectroscopy, and inductively coupled plasma mass spectrometry. Four samples of NaCl + MgCl 2 + x mol% PuCl 3 and four samples of NaCl + UCl 3 + x mol% PuCl 3 were prepared at the Plutonium Facility, shipped to the Los Alamos Neutron Science Center (LANSCE), and radiographed with the density via neutron radiography (DvNR) apparatus. Density data in the form of meniscus heights were recorded as a function of temperature. The results show a linear dependence of density with temperature and a third order polynomial dependence of density with composition as a function of PuCl 3 addition in the corresponding halide salt mixture. Additions of PuCl 3 result in a significant increase in density of the salt mixture and a slight reduction in the coefficient of volumetric expansion. These results represent a first measurement of the density of plutonium chloride salt mixtures and, in combination with additional measurements, may lead to a generalized description of the density of such salt systems for arbitrary compositions and temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗