Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray CT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

X-Ray Computed Tomography Monitors Damage in Composites

The NASA Lewis Research Center recently codeveloped a state-of-the-art x-ray CT facility (designated SMS SMARTSCAN model 100-112 CITA by Scientific Measurement Systems, Inc., Austin, Texas). This multipurpose, modularized, digital x-ray facility includes an imaging system for digital radiography, CT, and computed laminography. The system consists of a 160-kV microfocus x-ray source, a solid-state charge-coupled device (CCD) area detector, a five-axis object-positioning subassembly, and a Sun SPARCstation-based computer system that controls data acquisition and image processing. The x-ray source provides a beam spot size down to 3 microns. The area detector system consists of a 50- by 50- by 3-mm-thick terbium-doped glass fiber-optic scintillation screen, a right-angle mirror, and a scientific-grade, digital CCD camera with a resolution of 1000 by 1018 pixels and 10-bit digitization at ambient cooling. The digital output is recorded with a high-speed, 16-bit frame grabber that allows data to be binned. The detector can be configured to provide a small field-of-view, approximately 45 by 45 mm in cross section, or a larger field-of-view, approximately 60 by 60 mm in cross section. Whenever the highest spatial resolution is desired, the small field-of-view is used, and for larger samples with some reduction in spatial resolution, the larger field-of-view is used.

Baaklini, George Y.↗

Computed tomography for non-destructive evaluation of composites: Applications and correlations

The state-of-the-art fabrication techniques for composite materials are such that stringent species-specific acceptance criteria must be generated to insure product reliability. Non-destructive evaluation techniques including computed tomography (CT), X-ray radiography (RT), and ultrasonic scanning (UT) are investigated and compared to determine their applicability and limitations to graphite epoxy, carbon-carbon, and carbon-phenolic materials. While the techniques appear complementary, CT is shown to provide significant, heretofore unattainable data. Finally, a correlation of NDE techniques to destructive analysis is presented.

Goldberg, B.↗

Strong Thermoset Regolith UV-Curable Composite Technology (STRUCT) Overview

Future lunar surface missions require construction materials that can be manufactured in situ using lo-cal resources while operating under extreme environmental conditions. Many Lunar material demands can be solved solely with regolith by compacting or sintering. And yet past Lunar missions rely on polymeric materials, and sustained Lunar missions must reduce Earth-supplied polymers dependence. Dual-cure (Ultraviolet (UV) and thermal) polymer-regolith composites offer a promising pathway by leveraging solar UV radiation, moderate thermal in-put, and regolith. Mission mass limits, power availability and energy constraints on the lunar surface further motivate low-energy processing and curing strategies for surface construction materials. The Strong Thermoset Regolith UV-Curable Composite Technology (STRUCT) project has successfully synthesized and demonstrated dual-cure photopolymer resins derivable from in-situ resources [3]. Morphological, thermal, and mechanical characterization show that the newly formulated UV curable resin systems integrates well with lunar regolith simulants. Processing and chemistry changes, and computational analysis advanced the composite design. X-ray CT scanned and computational analysis demonstrate that resin, regolith and additives are well incorporated. The large fraction of regolith, 95% by mass, large char yield (82% mass), low thermal conductivity (0.26 W/m/K), confirm this material as a promising high-performance thermal and structural material.

thermal conductivity↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

User Directed Tools for Exploiting Expert Knowledge in an Immersive Segmentation and Visualization Environment

Volumetric data sets have become common in medicine and many sciences through technologies such as computed x-ray tomography (CT), magnetic resonance (MR), positron emission tomography (PET), confocal microscopy and 3D ultrasound. When presented with 2D images humans immediately and unconsciously begin a visual analysis of the scene. The viewer surveys the scene identifying significant landmarks and building an internal mental model of presented information. The identification of features is strongly influenced by the viewers expectations based upon their expert knowledge of what the image should contain. While not a conscious activity, the viewer makes a series of choices about how to interpret the scene. These choices occur in parallel with viewing the scene and effectively change the way the viewer sees the image. It is this interaction of viewing and choice which is the basis of many familiar visual illusions. This is especially important in the interpretation of medical images where it is the expert knowledge of the radiologist which interprets the image. For 3D data sets this interaction of view and choice is frustrated because choices must precede the visualization of the data set. It is not possible to visualize the data set with out making some initial choices which determine how the volume of data is presented to the eye. These choices include, view point orientation, region identification, color and opacity assignments. Further compounding the problem is the fact that these visualization choices are defined in terms of computer graphics as opposed to language of the experts knowledge. The long term goal of this project is to develop an environment where the user can interact with volumetric data sets using tools which promote the utilization of expert knowledge by incorporating visualization and choice into a tight computational loop. The tools will support activities involving the segmentation of structures, construction of surface meshes and local filtering of the data set. To conform to this environment tools should have several key attributes. First, they should be only rely on computations over a local neighborhood of the probe position. Second, they should operate iteratively over time converging towards a limit behavior. Third, they should adapt to user input modifying they operational parameters with time.

Senger, Steven O.↗

NDE of advanced turbine engine components and materials by computed tomography

Computed tomography (CT) is an X-ray technique that provides quantitative 3D density information of materials and components and can accurately detail spatial distributions of cracks, voids, and density variations. CT scans of ceramic materials, composites, and engine components were taken and the resulting images will be discussed. Scans were taken with two CT systems with different spatial resolution capabilities. The scans showed internal damage, density variations, and geometrical arrangement of various features in the materials and components. It was concluded that CT can play an important role in the characterization of advanced turbine engine materials and components. Future applications of this technology will be outlined.

Yancey, R. N.↗

Low temperature phase transformations in the metallic phases of iron and stony-iron meteorites

The nickel content and the structure of kamacite and decomposed taenite (clear taenite 1, CT-1; the cloudy zone, CZ; and clear taenite 2, CT-2) in the metallic phases of meteorites were determined using X-ray microanalysis techniques in the AEM. The kamacite near the CT-1 interface was found to contain about 4 wt pct Ni. The CT-1 structure contains 51.4-45.6 wt pct Ni; it is ordered FeNi with the L1(0) superstructure. The CZ structure consists of two phases: a globular phase (ordered FeNi containing 50.9 wt pct Ni) and a surrounding honeycomb martensitic phase containing 11.7 wt pct Ni. The CT-2 was found in all of the iron meteorite groups studied and in the pallasites, but not in the mesosiderites. Based on the preliminary evidence, this region is believed to be ordered Fe3Ni. Possible mechanisms for the decomposition of taenite are discussed.

Reuter, K. B.↗

Improved instrumental magnitude prediction expected from version 2 of the NASA SKY2000 master star catalog

The SKY2000 Master Star Catalog (MC), Version 2 and its predecessors have been designed to provide the basic astronomical input data needed for satellite acquisition and attitude determination on NASA spacecraft. Stellar positions and proper motions are the primary MC data required for operations support followed closely by the stellar brightness observed in various standard astronomical passbands. The instrumental red-magnitude prediction subsystem (REDMAG) in the MMSCAT software package computes the expected instrumental color index (CI) [sensor color correction] from an observed astronomical stellar magnitude in the MC and the characteristics of the stellar spectrum, astronomical passband, and sensor sensitivity curve. The computation is more error prone the greater the mismatch of the sensor sensitivity curve characteristics and those of the observed astronomical passbands. This paper presents the preliminary performance analysis of a typical red-sensitive CCDST during acquisition of sensor data from the two Ball CT-601 ST's onboard the Rossi X-Ray Timing Explorer (RXTE). A comparison is made of relative star positions measured in the ST FOV coordinate system with the expected results computed from the recently released Tycho Catalogue. The comparison is repeated for a group of observed stars with nearby, bright neighbors in order to determine the tracker behavior in the presence of an interfering, near neighbor (NN). The results of this analysis will be used to help define a new photoelectric photometric instrumental sensor magnitude system (S) that is based on several thousand bright star magnitudes observed with the PXTE ST's. This new system will be implemented in Version 2 of the SKY2000 MC to provide improved predicted magnitudes in the mission run catalogs.

Sande, C. B.↗

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

RTV↗

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

silicone intumescence↗

Assessment of Localized Deformations in Sand Using X-Ray Computed Tomography

The internal fabric and localized deformation patterns of triaxial sand specimens were investigated using Computed Tomography (CT). Three displacement-controlled, conventional, drained axisymmetric (triaxial) experiments were conducted on dry Ottawa sand specimens at very low effective confining stresses (0.05, 0.52, and 1.30 kPa) in a microgravity environment aboard the Space Shuttle during the NASA STS-79 mission. CT scanning was p'erformed on these flight specimens, as well as on an uncompressed specimen and a specimen tested in a terrestrial laboratory at 1.30 kPa effective confining stress. CT demonstrated high accuracy in detecting specimen inhomogeneity and localization patterns. Formation of deformation patterns is dependent on the effective confining stress and gravity. Multiple symmetrical radial shear bands were observed in the specimens tested in a microgravity environment. In the axial direction, two major conical surfaces were developed. Nonsymmetrical spatial deformation was observed in the 1-G specimen. Analysis tools were developed to quantify the spatial density change. Void ratio variation within and outside the shear bands was calculated and discussed.

Alshibli, Khalid A↗

Diagenetic Microcrystalline Opal Varieties from the Monterey Formation, CA: HRTEM Study of Structures and Phase Transformation Mechanisms

Microcrystalline opal varieties form as intermediary precipitates during the diagenetic transformation of biogenically precipitated non-crystalline opal (opal-A) to microquartz. With regard to the Monterey Formation of California, X-ray powder diffraction studies have shown that a decrease in the primary d-spacing of opal-CT toward that of cristobalite occurs with increasing diagenesis. The initial timing of opal-CT/quartz formation and the value of the primary opal-CT d-spacing, are influenced by the sediment. lithology. Transmission electron microscopy methods (CTEM/HRTEM) were used to investigate the structure of the diagenetic phases and establish transformation mechanisms between the varieties of microcrystalline opals in charts and porcelanites from the Monterey Formation. HRTEM images revealed that the most common fibrous varieties of microcrystalline opals contain varying amounts of structural disorder. Finite lamellar units of cristobalite-and tridymite-type. layer sequences were found to be randomly stacked in a direction perpendicular to the fiber axis. Disordered and ordered fibers were found to have coprecipitated within the same radial fiber bundles that formed within the matrix of the Most siliceous samples. HRTEM images, which reveal that the fibers within radial and lepispheric fiber bundles branch non-crystallographically, support an earlier proposal that microspheres in chert grow via a spherulitic growth mechanism. A less common variety of opal-CT was found to be characterized by non-parallel (low-angle) stacking sequences that often contain twinned lamellae. Tabular-shaped crystals of orthorhombic tridymite (PO-2) were also identified in the porcelanite samples. A shift in the primary d-spacing of opal-CT has been interpreted as an indication of solid-state ordering g toward a predominantly cristobalite structure, (opal-C). Domains of opal-C were identified as topotactically-oriented overgrowths on discrete Sections of opal-CT fibers and as lamellar domains within relict opal-CT fibers. These findings indicate that the type of transformation mechanism depends upon the primary structural characteristics of the authigenic opaline. varieties that are in turn influenced by the sediment lithology.

Cady, Sherry L.↗

A new CT collimator for producing two simultaneous overlapping slices from one scan

A new CT collimator is developed which is capable of producing two simultaneous successive overlapping images from a single scan. The collimator represents a modification of the standard EMI 5005 collimator achieved by alternately masking one end or portions of both ends of the X-ray detectors at a 13-mm beamwidth so that a set of 540 filtered projections is obtained for each scan which can be separated into two sets of interleaved projections corresponding to views 3 mm apart. Tests have demonstrated that the quality of the images produced from these two projections almost equals the quality of those produced by the standard collimator from two separate scans. The new collimator may thus be used to achieve a speed improvement in the generation of overlapping sections as well as a reduction in X-ray dosage.

Kwoh, Y. S.↗

Quantitative computed tomography for spinal mineral assessment: current status

Quantitative CT (QCT) is an established method for the noninvasive assessment of bone mineral content in the vertebral spongiosum and other anatomic locations. The potential strengths of QCT relative to dual photon absorptiometry (DPA) are its capability for precise three-dimensional anatomic localization providing a direct density measurement and its capability for spatial separation of highly responsive cancellous bone from less responsive cortical bone. The extraction of this quantitative information from the CT image, however, requires sophisticated calibration and positioning techniques and careful technical monitoring.

Lumbar Vertebrae/radiography↗

Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

Review↗

Assessment of metabolic bone diseases by quantitative computed tomography

Advances in the radiologic sciences have permitted the development of numerous noninvasive techniques for measuring the mineral content of bone, with varying degrees of precision, accuracy, and sensitivity. The techniques of standard radiography, radiogrammetry, photodensitometry, Compton scattering, neutron activation analysis, single and dual photon absorptiometry, and quantitative computed tomography (QCT) are described and reviewed in depth. Results from previous cross-sectional and longitudinal QCT investigations are given. They then describe a current investigation in which they studied 269 subjects, including 173 normal women, 34 patients with hyperparathyroidism, 24 patients with steroid-induced osteoporosis, and 38 men with idiopathic osteoporosis. Spinal quantitative computed tomography, radiogrammetry, and single photon absorptiometry were performed, and a spinal fracture index was calculated on all patients. The authors found a disproportionate loss of spinal trabecular mineral compared to appendicular mineral in the men with idiopathic osteoporosis and the patients with steroid-induced osteoporosis. They observed roughly equivalent mineral loss in both the appendicular and axial regions in the hyperparathyroid patients. The appendicular cortical measurements correlated moderately well with each other but less well with spinal trabecular QCT. The spinal fracture index correlated well with QCT and less well with the appendicular measurements. Knowledge of appendicular cortical mineral status is important in its own right but is not a valid predictor of axial trabecular mineral status, which may be disproportionately decreased in certain diseases. Quantitative CT provides a reliable means of assessing the latter region of the skeleton, correlates well with the spinal fracture index (a semiquantitative measurement of end-organ failure), and offers the clinician a sensitive means of following the effects of therapy.

Minerals/analysis↗

A new frame-based registration algorithm

This paper presents a new algorithm for frame registration. Our algorithm requires only that the frame be comprised of straight rods, as opposed to the N structures or an accurate frame model required by existing algorithms. The algorithm utilizes the full 3D information in the frame as well as a least squares weighting scheme to achieve highly accurate registration. We use simulated CT data to assess the accuracy of our algorithm. We compare the performance of the proposed algorithm to two commonly used algorithms. Simulation results show that the proposed algorithm is comparable to the best existing techniques with knowledge of the exact mathematical frame model. For CT data corrupted with an unknown in-plane rotation or translation, the proposed technique is also comparable to the best existing techniques. However, in situations where there is a discrepancy of more than 2 mm (0.7% of the frame dimension) between the frame and the mathematical model, the proposed technique is significantly better (p < or = 0.05) than the existing techniques. The proposed algorithm can be applied to any existing frame without modification. It provides better registration accuracy and is robust against model mis-match. It allows greater flexibility on the frame structure. Lastly, it reduces the frame construction cost as adherence to a concise model is not required.

NASA Center ARC↗