Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray Integral Field Unit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Optimization of X-ray Absorbers for High-Resolution TES Detectors in NewATHENA X-IFU

NewATHENA’s X-ray Integral Field Unit (X-IFU) uses a large-format array of Transition Edge Sensor (TES) microcalorimeters coupled with absorbers made of gold and bismuth providing 4 eV FWHM resolution up to 7 keV in the 0.2- 12 keV band. X-ray absorbers must be thick enough for photon absorption, maintain low heat capacity for energy resolution, and have good thermalization properties. The X-IFU requires total Quantum Efficiency (QE) of 96%, 87%, and 63% at 1, 7, and 9.5 keV, respectively. Optimal thicknesses are 1.05 µm gold and 5.5 µm bismuth to achieve 0.731 pJ/K at 90 mK and 87% QE at 7 keV. While typical TES absorbers are 3-4 µm thick, producing the required 5.5 µm Bi absorbers via standard electroplating creates enlarged grains and surface roughness. The increased roughness and grain size variability produced with our standard recipe have resulted in instances of 1) low energy spectral tails 2) spectral broadening of the energy resolution and 3) thermal shorts between pixels when a large grain bridges the gap between absorbers. In this study, we have introduced a new fabrication process and altered the morphology of the thick Bi through changes in the electroplating process. The process changes are intended to address all three issues as well as reduce particulate contamination observed on the finished detector arrays.

Absorber↗

Multinuclear Solid-State NMR and NMR Crystallography of Solid Forms of Creatine and Creatinine

Creatine is a performance-enhancing supplement with two widely available commercial solid forms, namely, creatine monohydrate (creatine·H 2 O) and creatine HCl, the latter of which does not have a reported crystal structure. Moreover, commercial formulations of creatine may contain creatinine, an undesired impurity phase resulting from the self-cyclization of creatine during manufacturing. Therefore, reliable methods for characterizing the different solid forms of creatine and detecting the presence of creatinine are essential. Herein, we address these challenges using 13 C, 15 N, and 35 Cl solid-state NMR (SSNMR) spectroscopy to obtain distinct spectral fingerprints for creatine·H 2 O and creatine HCl, along with creatinine and creatinine HCl. The acquisition of these SSNMR spectra offers a robust approach for both the rapid characterization of each solid form and the detection of the impurity phases. Additionally, quadrupolar NMR crystallography-guided crystal structure prediction (QNMRX-CSP) was applied for the de novo crystal structure determination of creatine HCl, which was validated by the subsequently determined single-crystal X-ray diffraction (SCXRD) structure. Finally, to investigate the relationship between NMR parameters and structural features, 13 C and 15 N chemical shifts and 35 Cl electric field gradient (EFG) tensors were computed from geometry-optimized structures of the four solid forms by using dispersion-corrected DFT-D2* methods. Finally, this integrative approach offers a powerful framework for advancing the structural understanding and quality control of creatine-based supplements and next-generation formulations, as well as a wide range of other solid pharmaceuticals and nutraceuticals.

NMR↗

Unveiling nano-scale crystal deformation using coherent X-ray dynamical diffraction

Visualization of internal deformation fields in crystalline materials helps bridge the gap between theoretical models and practical applications. Applying Bragg coherent diffraction imaging under X-ray dynamical diffraction conditions provides a promising approach to the longstanding challenge of investigating the deformation fields in micron-sized crystals. Here, we present an automatic differentiation-based reconstruction method that integrates dynamical scattering theory to accurately reconstruct deformation fields in large crystals. Using this forward model, our simulated and experimental results demonstrate that three-dimensional local strain information inside a large crystal can be accurately reconstructed under coherent X-ray dynamical diffraction conditions with Bragg coherent X-ray diffraction imaging. These findings open an avenue for extending the investigation of local deformation fields to microscale crystals while maintaining nanoscale resolution, leveraging the enhanced coherence and brightness of advanced X-ray sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based X-ray microscope

With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

3D virtual histology↗

Plasma-Enhanced Atomic Layer Deposition Synthesis of Nanolayered Molybdenum Diselenide (MoSe 2 ) Thin Films for Nanoelectronics

Nanolayered molybdenum diselenide (MoSe 2 ) thin films were synthesized by plasma-enhanced atomic layer deposition (PE-ALD) using molybdenum pentachloride (MoCl 5 ) and diethyldiselenide (C 4 H 10 Se 2 ) precursors. Scanning and transmission electron microscopy revealed horizontally stacked nanolayers near the substrate and vertically oriented nanosheets at the surface of the film. X-ray diffraction confirmed the (002), (100), and (110) reflections of crystalline MoSe 2 , while X-ray photoelectron spectroscopy showed relative atomic concentrations of 33.5% Mo and 66.5% Se, consistent with stoichiometric MoSe 2 . Raman spectra exhibited characteristic E 1g , A 1g , and E$^1_{2g}$ vibrational modes. Field-effect transistors incorporating PE-ALD-grown MoSe 2 as the channel material displayed p-type behavior, demonstrating the potential of nanolayered MoSe 2 for nanoelectronic applications. This work demonstrates the feasibility of low-temperature, stoichiometric growth of nanolayered MoSe 2 by PE-ALD and its direct integration into transistor architectures.

36 MATERIALS SCIENCE↗

Decoding THz‐Driven Dynamic Fingerprints of Ferroelectric Nanotwin Networks

Ultrafast polarization dynamics in ferroelectrics are of considerable interest for high-speed tunable dielectrics and electro-optics. Extended domain wall networks formed in ferroelectric twin nanodomains can support collective dynamics in the terahertz regime but require techniques that track polarization and strain evolution driven by ultrafast stimulus. Here, we use multi-modal probing of THz-pulse-driven excitations in PbTiO 3 /SrTiO 3 superlattices by combining X-ray free electron laser measurements that directly tracks lattice changes, with optical second harmonic generation that tracks the electronic potential coupled with the lattice potential. Dynamical phase-field modeling enables fingerprinting of these collective modes as superpositions of domain “breathing” through wall oscillations and polarization “rotations” with still walls. Ultrafast domain wall motion at 0.1–0.5 THz is observed at practical fields of 100 kV/cm with wall velocities of >4000 m/s, approaching typical speed of sound in PbTiO 3 . A unique “charging” mode is discovered that can electrically charge and discharge domain walls on ∼4 ps time scale thus dynamically tuning wall conductivity. Integrated experimental and theoretical fingerprinting of the dynamical landscape presented here enables ultrafast control of ferroics for high-speed microelectronics and optical applications.

THz dynamics↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

Pattern-enhanced Resonant Soft X-ray Scattering for Operando monitoring of electrochemical solid-liquid interfaces

Unveiling interfaces at sub-nanometer scales is essential for advancing the understanding of complex chemical transformations. However, characterizing solid-liquid interfaces with high dimensional sensitivity and temporal resolution remains challenging, due to their dynamic nature and inaccessibility by conventional probes. Here we present an approach, Pattern-enhanced Resonant Soft X-ray Scattering, to overcome the challenges. Rooted in a “sample-as-optics” philosophy, this technique utilizes precisely engineered line-grating nanopatterns to modulate near-field X-ray illumination, coherently enhancing scattering signals from the line-gratings. We implement the method using Ni line-grating nanopatterns in electrochemical water oxidation. The periodic nanostructures serve as diffractive optical elements to reveal the Ni oxidation gradients and structural dynamics at the electrode-electrolyte interfaces. Finite-element simulations corroborate the observed trends by modeling variations in compositions and structures during electrocatalysis. Through integrating advanced sample design with coherent wave nature of soft X-rays, our approach opens accessible pathways to operando exploring chemical evolution and sub-nanometer dimensional variations simultaneously in electrochemical systems. This non-destructive method is efficient and element-specific, making it valuable for probing chemical and dimensional dynamics with appropriate modeling.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metalloproteins in an Era of Modern Crystallography and Why the Beamline Matters

The Structural Molecular Biology (SMB) macromolecular crystallography (MC) group at the Stanford Synchrotron Radiation Lightsource (SSRL) have developed state-of-the-art capabilities tailored for metalloenzyme structural analysis. Metalloproteins sit at the center of biology’s most audacious chemistry. From multi-electron redox catalysis to radical rearrangements and light-driven transformations, metal sites give proteins access to reaction landscapes that would otherwise be inaccessible under ambient conditions. Yet their study presents a fundamental paradox for MC studies: the very X-rays we use to reveal atomic structure can alter the electronic states we seek to understand. As the field moves beyond static snapshots toward mechanistic insight, success increasingly depends on our ability to maintain metal centers in their native state throughout the experiment. The SSRL SMB-MC beamlines integrate a suite of capabilities specifically designed to address these challenges. By combining in situ spectroscopic verification, intelligent dose management, controlled reaction initiation, optimized anomalous diffraction, and real-time crystallographic diffraction analysis, these tools enable researchers to interrogate metalloproteins with unprecedented rigor. This article explores how these complementary approaches are reshaping our ability to capture metalloprotein chemistry, and what this means for mechanistic studies at synchrotron beamlines.

Maggiolo, Ailiena O. [SLAC National Accelerator La↗

Development of a coupled experimental–computational approach for engineering optimization of spout-fluidized bed particle coating systems

The design of spout-fluidized bed (SFB) coating systems for nuclear particle fuels typically relies on trial-and-error processes, comprising iterative and time-consuming coating deposition experiments and post-deposition characterization. At an engineering scale, this approach to guided SFB system design is inefficient, highlighting the need for streamlined experimental methodologies which can correlate fluidization conditions to downstream coating outcomes. In this study, we combine time-resolved particle image velocimetry (PIV) with CFD–DEM simulations to benchmark hydrodynamic behavior in a 3D spout-fluidized bed. By exploiting easily accessible optical measurements of particle motion at the bed wall and within the spouting region, we obtain quantitative velocity fields that can be directly compared with model predictions of the occluded bed region, without resorting to complex imaging and characterization techniques such as X-ray or magnetic resonance tomography. Experimental benchmarking reveals strong agreement between CFD–DEM and PIV in the spout and annulus regions, while discrepancies near the wall highlight areas for future model development. Here, the proposed integrated experimental–numerical framework will enable a direct connection between measured variables and numerically predicted fluidization performance of dense, surrogate nuclear particle fuel feedstock such that experimental SFB component design can be rapidly evaluated, informing design decisions for nozzle geometry and operating conditions. Future work will extend this framework by correlating quantified fluidization metrics across nozzle geometries and operating conditions with the resulting coating morphology, microstructure, and uniformity. Establishing these correlations will enable predictive links between hydrodynamic performance and coating quality, providing a rational, scalable basis for optimizing SFB design prior to coating deposition.

CFD/DEM↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

Search for active and inactive ion insertion sites in organic crystalline materials

The position of mobile active and inactive ions, specifically ion insertion sites, within organic crystals, significantly affects the properties of organic materials used for energy storage and ionic transport. Identifying the positions of these atomic (and ionic) sites in an organic crystal is challenging, especially when the element has low X-ray scattering power, such as lithium (Li) and hydrogen, which are difficult to detect by powder X-ray diffraction. First-principles calculations, exemplified by density functional theory (DFT), are very practical for confirming the relative stability of ion positions in materials. However, the lack of effective strategies to identify ion sites in these organic crystalline frameworks renders this task extremely challenging. This work presents two algorithms: the (i) efficient location of ion insertion sites from extrema in electrostatic local potential and charge density (ELIISE), and the (ii) ElectRostatic InsertioN (ERIN), which leverage charge density and electrostatic potential fields accessed from first-principles calculations, combined with the Simultaneous Ion Insertion and Evaluation (SIIE) workflow. SIIE inserts all ions simultaneously—to determine ion positions in organic crystals. We demonstrate that these methods accurately reproduce known ion positions in 16 organic materials and identify previously overlooked low-energy sites in tetralithium 2,6-naphthalenedicarboxylate (Li4NDC), an organic electrode material, highlighting the importance of inserting all ions simultaneously, as in the SIIE workflow. These algorithms are also integrated with off-the-shelf machine learning potentials, yielding promising results comparable to first-principles findings.

Gopidi, Harshan Reddy [Argonne National Laboratory↗

Micromechanical and fatigue in situ synchrotron characterization of an additively manufactured superalloy with porosity

Additive manufacturing (AM) has the potential to transform component production, but its widespread adoption is constrained by defects, such as pores, that compromise structural integrity. Here, this study investigates the influence of porosity on the micromechanical and fatigue response of AM Inconel 718 (IN718), a widely used aerospace superalloy. One baseline specimen with minimal stochastic porosity and another intentionally seeded with lack of fusion (LOF) pores were examined using high-energy X-ray diffraction microscopy (HEDM) and micro-computed tomography during cyclic loading. Fatigue cracks in the LOF specimen initiated more frequently and at lower cycle counts than in the baseline specimen. The number fraction of fatigue cracks that grew was comparatively higher in the LOF specimen. Grain-level metrics, including stress and diffraction spot widths, were quantified using far-field HEDM. Across the thousands of grains detected in both specimens, the pores in the LOF specimen increased the variability of stress and spot width evolution in the azimuthal direction, the latter serving as a surrogate measure of plastic deformation. However, no correlations emerged between these metrics and grain proximity to fatigue crack initiation sites or pores, underscoring the limitations of grain-averaged metrics for predicting fatigue. Nonetheless, the rich dataset reported here provides a foundation for future modeling efforts.

High-energy X-ray diffraction microscopy↗

Prediction and Experimental Verification of Electrolyte Solvation Structure from an OMol25-Trained Interatomic Potential

A molecular-level understanding of electrolyte solvation structure and ion–ion correlations is critical to developing next-generation battery chemistries. Atomistic simulation capabilities with sufficient accuracy, speed, and transferability to deliver reliable structural insights while avoiding arduous system-specific reparameterization are thus highly desirable. Machine learning interatomic potentials (MLIPs) trained on large, chemically diverse data sets are revolutionizing computational chemistry, enabling molecular dynamics simulations of battery electrolytes with near-DFT accuracy over 10,000× faster than DFT. While previous MLIP training data sets with suitable elemental coverage for electrolytes have been based on inorganic materials, the Open Molecules 2025 (OMol25) data set provides large-scale molecular DFT MLIP training data with broad elemental coverage and specifically samples tens of millions of electrolyte configurations. Here, we integrate computational modeling with experimental validation to systematically assess the ability of large-scale MLIPs pretrained on materials data or on OMol25 to accurately resolve nanoscale structural organization and ion-solvation characteristics in Na-ion battery electrolytes across diverse physicochemical conditions and compositional regimes. We find that the OMol25-trained Universal Model of Atoms (UMA-OMol) predicts experimentally measured densities and X-ray structure factors in substantially better agreement compared to state-of-the-art models trained only on inorganic materials data. Using UMA-OMol, we further analyze systematic trends in solvation structure as a function of cation identity, anion chemistry, salt concentration, and solvent topology. We observe that increasing system temperature amplifies the heterogeneity within the solvation environment, perturbing cation–solvent interactions and promoting the formation of contact ion pairs (CIPs). Moreover, subtle variations in the solvent topology of glyme-based electrolytes cause pronounced changes in ion correlations and solvation structure. The experimental agreement and microscopic insights shown here position OMol25-trained MLIPs as a practical route to predictive, high-throughput electrolyte simulations beyond the limits of classical force fields and direct DFT molecular dynamics, serving as a powerful tool for accelerating the design of next-generation Na-ion battery electrolytes and beyond.

MLIPs↗

Data-Driven Discovery and Experimental Validation of Solvent Polarity Effects on Conjugated Polymer Solution-to-Film Assembly Pathways

Understanding how solvent properties influence the solution-to-film assembly of conjugated polymers remains a critical challenge due to the complex and intertwined nature of polymer–solvent interactions. In this study, we integrate a data-driven framework with experimental validation to identify key parameters influencing the assembly and performance of poly[2,5-(2-octyldodecyl)-3,6-diketopyrrolopyrrole-alt-5,5-(2,5-di(thien-2-yl)thieno[3,2-b]thiophene)] (DPP-DTT) in organic field-effect transistors (OFETs). A machine learning (ML) approach identified the normalized Reichardt polarity parameter (E T N ) as a significant descriptor correlated with DPP-DTT hole mobility (μ). Systematic DPP-DTT devices fabricated using solvents across a wide E T N range revealed that higher E T N solvents yield enhanced μ. To elucidate the structural origins of high μ, we conducted comprehensive analyses using UV–vis–NIR spectroscopy and grazing incidence wide angle X-ray scattering (GIWAXS) measurements. The results revealed that films processed from high E T N solvents exhibit reduced paracrystallinity. By analyzing the solution-state behavior using optical microscopy and solution WAXS, we revealed polymer solubility differences in the various solvents and associated distinct polymer assembly pathways, elucidating why the high E T N solvent produces long-range ordered films. Notably, the high E T N solvent shows a pronounced preference for liquid-crystal (LC)-mediated assembly, providing a mechanistic explanation for the enhanced structural order. Therefore, these results demonstrate that solvent polarity, as evaluated by E T N , serves as an important parameter that plays a significant role in the DPP-DTT assembly pathway and resultant solid-state morphology. This work provides a strategy for integrating data science with experiments to identify critical parameters associated with complex polymer systems and helps guide rational process design for high-performance organic electronics.

36 MATERIALS SCIENCE↗

Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗