Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray Projection Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The HESP (High Energy Solar Physics) project

A project for space observations of solar flares for the coming solar maximum phase is briefly described. The main objective is to make a comprehensive study of high energy phenomena of flares through simultaneous imagings in both hard and soft X-rays. The project will be performed with collaboration from US scientists. The HESP (High Energy Solar Physics) WG of ISAS (Institute of Space and Astronautical Sciences) has extensively discussed future aspects of space observations of high energy phenomena of solar flares based on successful results of the Hinotori mission, and proposed a comprehensive research program for the next solar maximum, called the HESP (SOLAR-A) project. The objective of the HESP project is to make a comprehensive study of both high energy phenomena of flares and quiet structures including pre-flare states, which have been left uncovered by SMM and Hinotori. For such a study simultaneous imagings with better resolutions in space and time in a wide range of energy will be extremely important.

Kai, K.↗

Radio and X-ray observations of the radio halo source in A1367

Radio and X-ray observations of the 'radio halo' in A1367 are presented. The radio spectral index distribution is derived combining data at 610 and 1415 MHz taken with the Westerbork Synthesis Radio Telescope (WSRT). A high-resolution Very Large Array (VLA) map allows us to discriminate between the extended cluster emission and a triple radio source associated with a background stellar object (most probably a QSO) which appears projected onto it. X-ray observations taken with the high-resolution imager on board the Einstein satellite reveal an X-ray source associated with this background object. A second weak X-ray enhancement is found projected onto the extended radio component. Inverse Compton scattering of the synchrotron-emitting particles provides a possible interpretation of such a source. The presence of large-scale magnetic fields and particle acceleration due to the turbulent motion of galaxies through the intergalactic medium is discussed in relationship to the observed peculiarities of the galaxies found in this region.

Gavazzi, G.↗

Skylab simulator visual displays and training for joint observing programs

The complexity of the Skylab Apollo Telescope Mount (ATM) experiment operations necessitated the use of high fidelity simulations of the onboard visual displays and pointing system for crew training. The displays which were simulated included the H-alpha displays, XUV monitor display, XUV/slit/white light display, X-ray image display, and the white light coronagraph display. The pointing simulation was achieved by projecting film sequences which were subsequently viewed by TV cameras. An optical system in front of the vidicons simulated the pointing, roll, and zoom capabilities of the ATM and sensing systems. The simulation enabled the Skylab crewmen to obtain valuable integrated training combining such tasks as target recognition and status assessment, complex and the time dependent pointing operations, malfunction analyses, and rapid responses to flare and other transient events.

Holt, A. C.↗

A new CT collimator for producing two simultaneous overlapping slices from one scan

A new CT collimator is developed which is capable of producing two simultaneous successive overlapping images from a single scan. The collimator represents a modification of the standard EMI 5005 collimator achieved by alternately masking one end or portions of both ends of the X-ray detectors at a 13-mm beamwidth so that a set of 540 filtered projections is obtained for each scan which can be separated into two sets of interleaved projections corresponding to views 3 mm apart. Tests have demonstrated that the quality of the images produced from these two projections almost equals the quality of those produced by the standard collimator from two separate scans. The new collimator may thus be used to achieve a speed improvement in the generation of overlapping sections as well as a reduction in X-ray dosage.

Kwoh, Y. S.↗

NGC 2110 - A Seyfert and X-ray elliptical galaxy with displaced kinematic and light centers

Kinematic and imaging observations of NGC 2110 are reported and it is found that the interstellar gas is orbiting with projected rotation axis parallel to the minor axis of the stellar light. The rotation curve is steep close to the center and flat farther out. However, the nucleus is displaced by about 220 pc from the apparent mass center of the galaxy. This last result is discussed in terms of models invoking differential obscuration of stars and gas, non-Keplerian motion of the gas, or a large mass of unseen material which dominates the rotation curve.

Wilson, A. S.↗

Computer measurement and representation of the heart in two and three dimensions

Methods for the measurement and display by minicomputer of cardiac images obtained from fluoroscopy to permit an accurate assessment of functional changes are discussed. Heart contours and discrete points can be digitized automatically or manually, with the recorded image in a video, cine, or print format. As each frame is digitized it is assigned a code name identifying the data source, experiment, run, view, and frame, and the images are filed for future reference in any sequence. Two views taken at the same point in the heart cycle are used to compute the spatial position of the ventricle apex and the midpoint of the aortic valve. The remainder of the points on the chamber border are corrected for the linear distortion of the X-rays by projection to a plane containing the chord between the apex and the aortic valve center and oriented so that lines perpendicular to the chord are parallel to the image intensifier face. The image of the chamber surface is obtained by generating circular cross sections with diameters perpendicular to the major chord. The transformed two- and three-dimensional imagery can be displayed in either static or animated form using a graphics terminal.

Rasmussen, D.↗

Conical foil X-ray mirrors - Performance and projections

The design, fabrication, and performance of conical grazing incidence mirrors designed to increase the sensitivity and resolution of observations in the iron K spectral band around 7 KeV are discussed. The present mirrors consist of two adjacent, coaxial and confocal arrays of tightly packed fixed-length cones. Heat treatment is used to minimize distortions in forming the cones. Reflector assembly is simplified by changing from rectangular reflector support slots to tapered ones. An image-blur of only 1.3 arcmin half-power radius has been achieved, in addition to X-ray reflectivity in the 1.5-10 keV range at about the 90 percent level of theoretical values.

Serlemitsos, Peter J.↗

Biomedical technology transfer. Applications of NASA science and technology

Ongoing projects described address: (1) intracranial pressure monitoring; (2) versatile portable speech prosthesis; (3) cardiovascular magnetic measurements; (4) improved EMG biotelemetry for pediatrics; (5) ultrasonic kidney stone disintegration; (6) pediatric roentgen densitometry; (7) X-ray spatial frequency multiplexing; (8) mechanical impedance determination of bone strength; (9) visual-to-tactile mobility aid for the blind; (10) Purkinje image eyetracker and stabilized photocoalqulator; (11) neurological applications of NASA-SRI eyetracker; (12) ICU synthesized speech alarm; (13) NANOPHOR: microelectrophoresis instrument; (14) WRISTCOM: tactile communication system for the deaf-blind; (15) medical applications of NASA liquid-circulating garments; and (16) hip prosthesis with biotelemetry. Potential transfer projects include a person-portable versatile speech prosthesis, a critical care transport sytem, a clinical information system for cardiology, a programmable biofeedback orthosis for scoliosis a pediatric long-bone reconstruction, and spinal immobilization apparatus.

Harrison, D. C.↗

An atlas of X-ray-selected quasi-stellar objects

Coordinates, finding charts, photometry, and spectroscopy are presented for 55 X-ray selected QSOs. The selection technique, optical identification of X-ray sources observed serendipitously by the Einstein Observatory was used to find QSOs projected near bright galaxies, pairs of QSOs with similar redshifts; and low-redshift QSOs (z less than 0.5) which are well suited for imaging. Very luminous QSOs of more than 10 to the 46th ergs/s, and a very-high redshift X-ray-selected object were also found. It is suggested that most efforts to identify optically faint QSO counterparts to X-ray sources may yield intrinsically less luminous objects at redshifts less than 1 due to the weak influence of the limiting magnitude on the mean redshift of the sample. A complete list of the QSOs is given.

Margon, B.↗

Experimental evaluation of the ring focus test for X-ray telescopes using AXAF's technology mirror assembly, MSFC CDDF Project No. H20

A test method particularly suited for X-ray telescopes was evaluated experimentally. The method makes use of a focused ring formed by an annular aperture when using a point source at a finite distance. This would supplement measurements of the best focus image which is blurred when the test source is at a finite distance. The telescope used was the Technology Mirror Assembly of the Advanced X-ray Astrophysis Facility (AXAF) program. Observed ring image defects could be related to the azimuthal location of their sources in the telescope even though in this case the predicted sharp ring was obscured by scattering, finite source size, and residual figure errors.

Zissa, D. E.↗

Apparatus for use in examining the lattice of a semiconductor wafer by X-ray diffraction

An improved apparatus for examining the crystal lattice of a semiconductor wafer utilizing X-ray diffraction techniques was presented. The apparatus is employed in a method which includes the step of recording the image of a wafer supported in a bent configuration conforming to a compound curve, produced through the use of a vacuum chuck provided for an X-ray camera. The entire surface thereof is illuminated simultaneously by a beam of incident X-rays which are projected from a distant point-source and satisfy conditions of the Bragg Law for all points on the surface of the water.

Parker, D. L.↗

An X-ray investigation of the unusual supernova remnant CTB 80

The X-ray properties of SNR CTB 80 (G68.8 + 2.8) are discussed based on both low- and high-resolution images from the Einstein satellite. The X-ray maps show a point source coinciding with the region of maximum radio emission. Diffuse X-ray emission is evident mainly along the radio lobe extending about 8 arcmin east of the point source and aligned with the projected magnetic field lines. The observed X-ray luminosity is 3.2 x 10 to the 34th ergs/s with 1.0 x 10 to the 3th ergs/s from the point source (assuming a distance of 3 kpc). There is also faint, diffuse, X-ray emission south of the point source, where radio emission is absent. The unusual radio and X-ray morphologies are interpreted as a result of relativistic jets energized by the central object, and the possible association of CTB 80 with SN 1408 as recorded by Chinese observers is discussed.

Wang, Z. R.↗

X-ray calibration of a virtual phase 1024 x 1024 CCD

Results are presented on a calibration with X-rays of a front-illuminated virtual phase CCD with a 1024 x 1024 pixel array, performed as a part of the Solar-A preparation, which is a joint Japanese-U.S.-UK space project scheduled for a launch in August 1991. In the experiment, absolute quantum efficiency (QE) of a virtual CCD was measured at 14 wavelengths between 5.4 and 67.7 A, and its flat field responses to the illumination by C-K and Al-K X-rays were investigated together with its imaging properties in visible light. Higher than expected QE measurements were obtained at soft X-ray and EUV wavelengths; these are considered to be caused by fluorescence occurring in the absorbing layers on the CCD-entrance aperture.

Catura, R. C.↗

Gas scintillation drift chambers with wave shifter read-out for hard X-ray astronomy

A major improvement in hard X-ray and gamma ray astrophysics could be provided by high pressure xenon time projection chambers where gas scintillation is used both for the measurement of the time of interaction and for the detection of the extracted electrons. This allows three dimensional imaging of naturally complex events (photoelectric interaction with escape photon, Compton scatter, and pair production). A novel read-out system based on wave shifter fibers, which is well suited to the high pressures and large areas required of a hard X-ray telescope is proposed. Expected performances are computed, potential problems are outlined, and the experimental effort to solve these problems are described.

Sadoulet, Bernard↗

NASA astrophysics - Optical systems to explore the universe

Major and minor NASA astrophysical research efforts in the near-term are outlined, together with projections of direction for future projects. The Space Telescope is being readied for a 1986 launch and will feature an f/24, 2.4 m aperture, an MgF2 mirror with better than 1/60 wavelength accuracy and will be diffraction-limited in the UV. Pointing accuracy is designed to be 0.007 arcsec for 24 hr. Optical, spectrometric, and photometric equipment will be included. Around 1990, Shuttle-based missions will include an IR telescope and a subarcsec solar surface imaging device. A free-flying X-ray observatory (AXAF) is planned and will include a sensitivity that exceeds that of the HEAO-2 spacecraft by two orders of magnitude. Instruments are under development for higher resolution UV, gamma-ray, and IR studies. In-orbit interferometry is being studied and will depend on in-orbit assembly and servicing of stable structures with segmented optics.

Pellerin, C. J., Jr.↗

The X-ray properties of normal galaxies. What do we know and what can we learn with the next generation of X-ray telescopes?

Einstein Observatory results are used to assess the possibilities of spaceborne X-ray astronomy projects such as XMM (ESA) and AXAF (NASA). Einstein observations show that normal galaxies of all morphological types are spatially extended sources of X-ray emission with 0.5 to 3.0 keV X-ray luminosities of 10 to the 39th to 41st power erg/sec. X-ray telescopes can study the end products of stellar evolution in galaxies of different morphological types. Phenomena linked to starburst nuclear activity can best be detected and studied in X-ray. Hot coronae or a hot phase of the interstellar medium can only be studied through their X-ray emission. It is shown that high spatial resolution is essential for studying normal galaxies and identifying different emission regions. Good spectral sensitivity and spectral imaging capability are essential for gaining a deeper understanding of the phenomena at work.

Fabbiano, G.↗

The metrology of spherical shells using synchrotron x ray microtomography

With recent advances in solid state imaging technology and the increasing availability of synchrotron x-ray radiation sources, synchrotron x-ray microtomography is emerging as a nondestructive technique for the evaluation of the structure and composition of small specimens with spatial resolution in the micron range. Synchrotron radiation offers the following advantages over conventional x-ray sources: high brightness, continuous emission which is tunable over a large energy range, faster data collection rates, and a highly collimated beam of large cross section permitting the illumination of large specimens. Synchrotron x-ray microtomography enables the structure of individual spheres to be evaluated in order to reveal the concentricity and sphericity of the internal void and the uniformity of the shell wall in the case of high quality spherical shells for Sandia National Laboratories' Inertial Confinement Fusion project.

Hmelo, Anthony B.↗

A First Look at Airborne Imaging Spectrometer (AIS) Data in an Area of Altered Volcanic Rocks and Carbonate Formations, Hot Creek Range, South Central Nevada

Three flight lines of Airborne Imaging Spectrometer (AIS) data were collected in 128 bands between 1.2 and 2.4 microns in the Hot Creek Range, Nevada on July 25, 1984. The flight lines are underlain by hydrothermally altered and unaltered Paleozoic carbonates and Tertiary rhyolitic to latitic volcanics in the Tybo mining district. The original project objectives were to discriminate carbonate rocks from other rock types, to distinguish limestone from dolomite, and to discriminate carbonate units from each other using AIS imagery. Because of high cloud cover over the prime carbonate flight line and because of the acquisition of another flight line in altered and unaltered volcanics, the study has been extended to the discrimination of alteration products. In an area of altered and unaltered rhyolites and latites in Red Rock Canyon, altered and unaltered rock could be discriminated from each other using spectral features in the 1.16 to 2.34 micron range. The altered spectral signatures resembled montmorillonite and kaolinite. Field samples were gathered and the presence of montmorillonite was confirmed by X-ray analysis.

Feldman, S. C.↗