Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray astronomy CCDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Charge coupled devices (CCDs) in X-ray astronomy

The application of CCDs to X-ray imaging and spectroscopy in astronomy is discussed with special attention given to the special requirements of CCDs for X-ray astronomy (as opposed to those for traditional optical applications). The development status of CCDs for X-ray astronomy applications is described, and results of recent research in the area of optimizing the CCD X-ray response are presented. It is shown that very high quantum efficiencies and Fano noise-limited energy resolutions can be obtained using CCDs.

Lumb, D. H.↗

Modeling Contamination Migration on the Chandra X-Ray Observatory - III

During its first 16 years of operation, the cold (about -60 C) optical blocking filter of the Advanced CCD Imaging Spectrometer (ACIS), aboard the Chandra X-ray Observatory, has accumulated a growing layer of molecular contamination that attenuates low-energy x rays. Over the past few years, the accumulation rate, spatial distribution, and composition have changed. This evolution has motivated further analysis of contamination migration within and near the ACIS cavity, in part to evaluate potential bake-out scenarios intended to reduce the level of contamination. Keywords: X-ray astronomy, CCDs, contamination, modeling and simulation, spacecraft operations

astrophysics↗

Modeling Contamination Migration on the Chandra X-Ray Observatory - IV

During its first 18 years of operation, the cold (about -60degC) optical blocking filters of the Advanced CCD Imaging Spectrometer (ACIS), aboard the Chandra X-ray Observatory, has accumulated a growing layer of molecular contamination, which attenuates low-energy x rays. Over the past several years, the accumulation rate, spatial distribution, and composition have changed. This evolution has motivated further analysis of contamination migration within and near the ACIS cavity, in part to evaluate potential bake-out scenarios intended to reduce the level of contamination. This paper, the fourth on this topic, reports the results of recent contamination-migration simulations and their relevance to a decision whether to bake-out the ACIS instrument.

X-ray astronomy CCDs↗

A Three-Year Program of Micro- and Nano-System Technology Development for X-Ray Astronomy

For many years the work at MIT aimed at the development of new concepts and technologies for space experiments in high-energy astrophysics, but not explicitly supported by flight programs, has been supported. This work has yielded new devices and techniques for X-ray astronomy, primarily low-noise, deep-depletion charge-coupled devices (CCDS) for spectrally-resolved X-ray imaging, and high-performance transmission gratings for high-resolution X-ray spectroscopy. Among the most significant recent achievements have been the development by G. Ricker and associates of the X-ray CCD camera flying on ASCA, and currently in development for AXAF and Astro-E, and the development by C. Canizares and associates of thick, 200 nm-period transmission gratings employing the phenomenon of phase shifting for high-resolution X-ray spectroscopy up to energies of 8- 1 0 keV that is essential for the operation of the AXAF High Energy Transmission Grating Spectrometer (HETGS). Through the current SR&T grant, the latter technology is now being extended successfully to the fabrication of 100 nm-period transmission gratings, which have twice the dispersion of the AXAF gratings. We note that, among other outcomes, the modest investments of past SR&T Grants at MIT resulted in the development of the key technologies for fully one-half of the scientific instrumentation on AXAF. In addition, NASA flight programs that have benefited from previous SR&T support at MIT include the SAS 3 X-ray Observatory, which carried the first rotation modulation collimator, the Focal Plane Crystal Spectrometer (FPCS) on the Einstein Observatory, the CCD cameras on ASCA and planned for Astro-E, the High Energy Transient Experiment (HETE), the Solar EUV Monitor on the Solar and Heliospheric Observatory (SOHO), the Medium Energy Neutral Atom imager (MENA) on the Image for Magnetopause-to-aurora Global Exploration (IMAGE) mission, and the recently-approved Two Wide-Angle Imaging Neutral-atom Spectrometers (TWINS) Mission of Opportunity.

Canizares, Claude R.↗

The development and applications of charge-coupled devices for space astronomy

The developments in charge-coupled device technology over the past decade are reviewed, with emphasis on the relevance of these developments to astronomical applications. The characteristics and limitations of current commercial devices are described, and the future requirements on CCDs for space astronomy are summarized for the X-ray and near UV, optical, and infrared wavelength ranges. Emphasis is placed on the commonality of technological development which is called for, including the issues of quantum detection efficiency (photon entrance and depletion depth), charge transfer efficiency, modulation transfer function, output noise level, and array size. The system requirements on focal plane instrumentation for space astronomy are summarized, and shown to have much in common for the different wavelength bands. These requirements are discussed in terms of CCD mosaicing, cryogenic cooling, and electronics. The overlap in CCD developments in the defense, astronomical and commercial arenas is summarized.

Griffiths, R. E.↗

Evaluation of a virtual phase charged-coupled device as an imaging X-ray spectrometer

The X-ray response of an 800 x 800 Texas Instruments virtual phase charge-coupled device (CCD) has been measured in the range 1-8 keV. In the single-photon counting mode, excellent energy resolution (approximately 250 eV FWHM is found for single-pixel Fe-55 X-ray events at a spatial resolution of 15 microns. The detector quantum efficiency for all events is 65% at 2.3 keV (S K line) and approximately 34% at 5.9 keV (Mn K line from Fe-55). The CCD response is linear in energy to a few percent over the 1-8 keV energy range. These results demonstrate that virtual phase CCDs are superior imaging X-ray spectrometers with applications for X-ray astronomy and laboratory plasma research.

Stern, R. A.↗

Potential of CCDs for UV and X-ray plasma diagnostics

A program is under way to develop charge-coupled device (CCD) sensors for space-based X-ray astronomy imaging spectrometers. To date, laboratory line-emission spectra have been acquired throughout the range of 277 to 8000 eV (carbon through copper K-alpha emission) and CCD sensitivity has been demonstrated throughout the range of 1.1 through 8000 eV. Image resolution is excellent, limited almost entirely by the 15 micron pixel size. These results are presented and specialized techniques are described which permit such low energy response, high spectral resolution, and efficient charge collection. Finally, analysis is presented of one particular CCD characteristic which currently limits UV and X-ray performance: charge diffusion.

Janesick, J. R.↗

Research in X-ray Astronomy

This research grant supported an active sounding rocket program at Penn State University over a period of over 10 years. During this period, the grant supported at least 8 graduate students in Astronomy & Astrophysics for at least a portion of their research. During the same period, our group was involved in seven sounding rocket flights, launched from White Sands, New Mexico, and from Woomera, Australia. Most of these rocket flights, and most of the work supported by this grant, involved the use of X-ray CCD cameras. The first X-ray CCD camera ever flown in space was our sounding rocket observation of SN1987A (flight 36.030 in 1987). Subsequent flights utilized improved CCD detectors, culminating in the'state-of-the-art EEV detector developed for our CUBIC mission, which was flown on 36.093 last May. Data from the last three flights, which observed the diffuse X-ray background with CCDS, include detection of the OVII He(alpha) line in the high latitude diffuse background and detection of the Mg XI He(alpha) line in the North Polar Spur. These results have been reported at meetings of the American Astronomical Society and the SPIE. The analysis of flights 36.092 and 36.106 is part of Jeff Mendenhall's PhD thesis and will be published in the Astrophysical Journal next year. The 36.093 data are currently being analyzed by PhD student Laura Cawley. From 1990 to 1996 this grant supported our development and launch of the CUBIC instrument on the SAC-B satellite, which was designed to measure the spectrum of the soft X-ray diffuse background with moderate energy resolution and high S/N ratio. Unfortunately, this mission terminated shortly after launch due to a failure of the Pegasus XL launch vehicle. This work resulted in publication of 4 papers in the SPIE Proceedings and four others in refereed journals, in addition to several other conference proceedings and contributed papers. In addition to the CCD flights described above, this grant has supported preliminary development of a new sounding rocket payload utilizing a replicated Ni mirror that is being developed at PSU in collaboration with MSFC. Initial testing of the coating technology has produced promising results.

Source record↗

Calibrating the broad band X-ray telescope

This paper describes the calibration of the two solid-state Si(Li) X-ray detectors and the X-ray telescopes that flew as part of Goddard Space Flight Center's Broad Band X-Ray Telescope (BBXRT) experiment on board the space shuttle Columbia in 1990 December. During the 9 day shuttle mission, BBXRT performed approximately 150 observations of 82 celestial sources. The content of the archive is summarized here. Although BBXRT had a relatively short life, it stands as a milestone in X-ray astronomy as being the first instrument to offer moderate spectral resolution over a wide bandpass (0.3-12.0 keV). Among other things, this paper discusses the effective area calibration of the instrument, the flux calibration and flux corrections for off-axis observations, the detector background, and optimal background subtraction techniques. The on-axis effective area calibration for the central detector elements was performed using data from the Crab Nebula, while other carefully selected targets were used for calibration of the outer detector elements. The remaining systematic uncertainties in the effective area calibration for point sources observed both on and off axis are generally less than 5%-10%. The energy scale is known to better than 0.5% at 6.0 keV for both detectors. The results presented here have an impact on the calibration of other medium resolution X-ray experiments such as the CCDs on board ASCA (Astro-D) as well as the Advanced X-Ray Astrophysics Facility detectors.

Weaver, K. A.↗