Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray concentrator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Glancing incidence telescopes for space astronomy

Design optimization is reported for glancing telescopes of increased collecting areas. Considered are nested geometries for X-ray and extreme ultraviolet telescopes, each of which generates only one singular principal surface. In the case of the X-ray telescope, the field curvature of the outer telescope serves as a standard and the focus of each of the inner telescopes is made coplanar by a slight descrease in the collecting area of each of the inner telescopes. In the case of the EUV telescope, a slight change in the maximum slope angle of the inner telescope makes the field curvatures coincide. Five concentric X-ray telescopes form a collecting area of approximately 900 sq cm, and a nested EUV telescope consisting of two concentric telescopes produces a collecting area of about 45 sq cm.

Mangus, J. D.↗

Diffuse X-rays from the galactic disk

An anisotropic feature of the diffuse hard X-ray background that tracks the concentration of interstellar hydrogen in the plane of the galaxy is reported. This feature supports a model of galactic X-ray emission by subrelativistic cosmic rays via a bremsstrahlung process. The measurement was carried out on August 9, 1971, using two multianode multilayer gas proportional counters onboard Aerobee 170 flight 13.08. A schematic diagram of the detectors is shown. This type of construction and the appropriate utilization of the signals from the many anodes result in a low detector background, a perequisite before undertaking a measurement of possible small variations in the brightness of the X-ray sky.

Serlemitsos, P. J.↗

Pattern recognition methods and air pollution source identification

Directional air samplers, used for resolving suspended particulate matter on the basis of time and wind direction were used to assess the feasibility of characterizing and identifying emission source types in urban multisource environments. Filters were evaluated for 16 elements and X-ray fluorescence methods yielded elemental concentrations for direction, day, and the interaction of direction and day. Large numbers of samples are necessary to compensate for large day-to-day variations caused by wind perturbations and/or source changes.

Leibecki, H. F.↗

Electron microprobe analysis program for biological specimens: BIOMAP

BIOMAP is a Univac 1108 compatible program which facilitates the electron probe microanalysis of biological specimens. Input data are X-ray intensity data from biological samples, the X-ray intensity and composition data from a standard sample and the electron probe operating parameters. Outputs are estimates of the weight percentages of the analyzed elements, the distribution of these estimates for sets of red blood cells and the probabilities for correlation between elemental concentrations. An optional feature statistically estimates the X-ray intensity and residual background of a principal standard relative to a series of standards.

Edwards, B. F.↗

Dynamic Nuclear Polarization in Samarium Doped Lanthanum Magnesium Nitrate

The dynamic nuclear polarization of hydrogen nuclei by the solid effect in single crystals of samarium doped lanthanum magnesium nitrate (Sm:LMN) was studied theoretically and experimentally. The equations of evolution governing the dynamic nuclear polarization by the solid effect were derived in detail using the spin temperature theory and the complete expression for the steady state enhancement of the nuclear polarization was calculated. Experimental enhancements of the proton polarization were obtained for eight crystals at 9.2 GHz and liquid helium temperatures. The samarium concentration ranged from 0.1 percent to 1.1 percent as determined by X-ray fluorescence. A peak enhancement of 181 was measured for a 1.1 percent Sm:LMN crystal at 3.0 K. The maximum enhancements extrapolated with the theory using the experimental data for peak enhancement versus microwave power and correcting for leakage, agree with the ideal enhancement (240 in this experiment) within experimental error for three of the crystals.

Byvik, C. E.↗

Apollo 16 geochemical X-ray fluorescence experiment - Preliminary report.

Mapping of the lunar surface with respect to magnesium, aluminum, and silicon as aluminum/silicon and magnesium/silicon intensity ratios along the projected ground tracks swept out by the orbiting Apollo 16 spacecraft. The results confirm the observations made during the Apollo 15 flight and provide new data for a number of features not covered before. The data are consistent with the idea that the moon has a widespread differentiated crust (the highlands). The aluminum/silicon and magnesium/silicon concentration ratios correspond to those for anorthositic gabbros through gabbroic anorthosites or feldspathic basalts. The X-ray results suggest the occurrence of this premare crust or material similar to it at the Descartes landing site.

Adler, I.↗

A preliminary design study for a cosmic X-ray spectrometer

The results are described of theoretical and experimental investigations aimed at the development of a curved crystal cosmic X-ray spectrometer to be used at the focal plane of the large orbiting X-ray telescope on the third High Energy Astronomical Observatory. The effort was concentrated on the development of spectrometer concepts and their evaluation by theoretical analysis, computer simulation, and laboratory testing with breadboard arrangements of crystals and detectors. In addition, a computer-controlled facility for precision testing and evaluation of crystals in air and vacuum was constructed. A summary of research objectives and results is included.

Source record↗

Disproportionation of Fe2SiO4 to 2FeO plus SiO2 at pressures up to 250kbar and temperatures up to 3000 C

A sample of Fe2SiO4 (spinel) at approximately 250 kbar in a diamond anvil press was heated to approximately 3000 C for a duration of some ms using a focused light beam from a pulsed ruby laser. After quenching and unloading, X-ray diffraction patterns indicated that the portion of the sample that had been heated contained wustite and stishovite. A sample of Fe2SiO4 (fayalite) at approximately 200 kbar in a diamond anvil press has been heated to 800 C for 20 min in a furnace. After quenching and unloading, the sample was found to have concentric zones with the fayalite phase at the lowest pressure, the spinel phase at the intermediate pressure, and a dark region at the center where the pressure was highest. An X-ray diffraction pattern of the dark central region indicated the presence of wustite. A microprobe analysis of a sample produced by a similar procedure indicated that SiO2 is apparently evolved along with wustite but is not sufficiently crystalline to be detected by X-ray diffraction.

Bassett, W. A.↗

Studies of positive-ion composition in the equatorial D-region ionosphere.

Evaluation of two daytime D-region positive-ion composition measurements performed at Thumba, India, for solar zenith angles of 53.2 and 27.8 deg. Comparison of upleg ram with downleg wake data shows a large increase in the concentration of heavy ions 48(+), NO(+) . H2O; 55(+), H3O(+) . (H2O)2; and M(+) greater than 65(+) for the downleg reduced shock condition. Peak concentrations of 48(+) and 55(+) occur at unit optical depth for Lyman alpha radiation. The ion 37(+), H3O(+) . H2O, is dominant for chi = 27.8 deg, but not for chi = 53.2 deg, consistent above 80 km with an origin from the X-ray production of O2(+). Laboratory measurements have shown that the ion, NO(+), can be transferred to heavy hydrates 48(+), 55(+), and M(+) greater than 65(+) by a reaction chain starting with NO(+) + X + M = NO(+) . X + M, where X can be O2, N2, CO2 or a combination of all three, depending on the rate of reaction. This chain, together with a similar reaction scheme starting with O2(+) and ending in 19(+), 37(+), and heavier clusters, is used to provide a consistent explanation for the hydrated ions observed in the D region.

Goldberg, R. A.↗

A focusing collector for long wavelength X-ray astronomy.

Rocket studies of the low-energy X-ray sky conducted so far suffer from serious experimental problems. Therefore, an apparatus was design ed to overcome the outstanding experimental problems. The instrument developed was successfully flown in an Aerobee-170 rocket. The new device utilizes a grazing incidence paraboloid as an energy concentrator and low-pass filter. The effective bandpass of the instrument from 100 to 280 eV is determined by the combination of the counter window transmission and the mirror reflectivity.

Yentis, D. J.↗

Investigation of superconducting interactions and amorphous semiconductors

Research papers on superconducting interactions and properties and on amorphous materials are presented. The search for new superconductors with improved properties was largely concentrated on the study of properties of thin films. An experimental investigation of interaction mechanisms revealed no new superconductivity mechanism. The properties of high transition temperature, type 2 materials prepared in thin film form were studied. A pulsed field solenoid capable of providing fields in excess of 300 k0e was developed. Preliminary X-ray measurements were made of V3Si to determine the behavior of cell constant deformation versus pressure up to 98 kilobars. The electrical properties of amorphous semiconducting materials and bulk and thin film devices, and of amorphous magnetic materials were investigated for developing radiation hard, inexpensive switches and memory elements.

Janocko, M. A.↗

Lunar elemental analysis obtained from the Apollo gamma-ray and X-ray remote sensing experiment

Gamma-ray and X-ray spectrometers carried in the service modules of the Apollo 15 and Apollo 16 spacecraft were employed for compositional mapping of the lunar surface. The measurements involved the observation of the intensity and characteristic energy distribution of gamma rays and X-rays emitted from the lunar surface. A large-scale compositional map of over 10 percent of the lunar surface was obtained from an analysis of the observed spectra. The objective of the X-ray experiment was to measure the K spectral lines from Mg, Al, and Si. Spectra were obtained and the data were reduced to Al/Si and Mg/Si intensity ratios and ultimately to chemical ratios. Analyses of the results have indicated (1) that the Al/Si ratios are highest in the lunar highlands and considerably lower in the maria, and (2) that the Mg/Si concentrations generally show the opposite relationship. The objective of the gamma-ray experiment was to measure the natural and cosmic-ray-induced activity emission spectrum. At this time, the elemental abundances for Th, U, K, Fe, Ti, Si, and O have been determined over a number of major lunar regions. Regions of relatively high natural radioactivity were found in the Mare Imbrium and Oceanus Procellarum regions.

Trombka, J. I.↗

Thermal Inspection for the Assessment of Adhesively Bonded Metal Adherends

Certification of adhesively bonded structures is currently a challenge for aircraft manufacturers. The ability to certify bonds in primary structure can reduce dependence on fasteners and this will enable more efficient manufacturing. For example, drilling holes and installing fasteners in bonded joints can be a potentially significant bottleneck in airframe manufacturing. In addition, fasteners increase the airframe weight and can add stress concentration areas. Reducing fastener count can accelerate manufacturing and improve aircraft performance. NASA is currently investigating nondestructive evaluation (NDE) techniques to assess bond integrity. For example, bond thickness influences bond strength and therefore NDE techniques are being investigated to determine bond thickness. For bonded metal structures, there is a large difference in the thermal diffusivity between the 7075 aluminum alloy metal adherends and aircraft grade adhesive. Multi-layered thermal models show a large variation in the thermal response for bondline adhesive thicknesses that vary from 100 to 300 microns for adherend thicknesses of 0.163 cm. Experimental through-transmission thermal measurements reveal promise to quantitatively characterize the bondline thickness. Results were validated with X-ray computed tomography and optical microscopy measurements, and influence of porosity on the thermal model and measurements are investigated.

X-ray computed tomography↗

Thermal Inspection for the Assessment of Adhesively Bonded Metal Adherents

Certification of adhesively bonded structures is currently a challenge for aircraft manufacturers. The ability to certify bonds in primary structure can reduce dependence on fasteners and this will enable more efficient manufacturing. For example, drilling holes and installing fasteners in bonded joints can be a potentially significant bottleneck in airframe manufacturing. In addition, fasteners increase the airframe weight and can add stress concentration areas. Reducing fastener count can accelerate manufacturing and improve aircraft performance. NASA is currently investigating nondestructive evaluation (NDE) techniques to assess bond integrity. For example, bond thickness influences bond strength and therefore NDE techniques are being investigated to determine bond thickness. For bonded metal structures, there is a large difference in the thermal diffusivity between the 7075 aluminum alloy metal adherends and aircraft grade adhesive. Multi-layered thermal models show a large variation in the thermal response for bondline adhesive thicknesses that vary from 100 to 300 microns for adherend thicknesses of 0.163 cm. Experimental through-transmission thermal measurements reveal promise to quantitatively characterize the bondline thickness. Results were validated with X-ray computed tomography and optical microscopy measurements, and influence of porosity on the thermal model and measurements are investigated.

bondline thickness↗