Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Atmospheric, Non-Combusting Droplet Sizing and Spray Imaging Results From a Non-Proprietary Aero Gas Turbine Engine Pressure Swirl Atomizer using Shadowgraphy and Planar Laser Scatter

Members from industry and federal agencies of the United States have developed a collaborating group focused on improving the understanding of the atomization processes common to gas turbine engines. The group is aimed on providing high quality data using x-ray diagnostics in the internal geometry and the near-field dense spray as well as optical diagnostics in the visible spectrum, downstream of the nozzle. This paper reports results from one of the two non-proprietary injectors designs from the group: the primary-secondary injector. In particular, we characterize the spray from only the primary, pressure-swirl atomizing circuit using water through the nozzle. We observed Sauter mean diameter decreased with increased water pressure drop across the nozzle. SMD was also collected at three axial distances and showed decreased size with distance from the nozzle. Planar laser sheet droplet scattering provided qualitative assessment of the spray. Higher water pressure drops provided better atomization than lower pressure drops. The addition of swirling air flow through the injector alleviates and improves the atomization quality, particularly at the lower water pressure drops.

optical diagnostics↗

A physical parameter method for the design of broad-band X-ray imaging systems to do coronal plasma diagnostics

The technique commonly used for the analysis of data from broad-band X-ray imaging systems for plasma diagnostics is the filter ratio method. This requires the use of two or more broad-band filters to derive temperatures and line-of-sight emission integrals or emission measure distributions as a function of temperature. Here an alternative analytical approach is proposed in which the temperature response of the imaging system is matched to the physical parameter being investigated. The temperature response of a system designed to measure the total radiated power along the line of sight of any coronal structure is calculated. Other examples are discussed.

Kahler, S.↗

Cylindrical Crystal Imaging Spectrometer (CCIS) for cosmic X-ray spectroscopy

A "stigmatic" focusing, Bragg crystal spectrometer was developed and used for high spectral resolution X-ray emission line diagnostics on hot laboratory plasmas. The concept be applied at the focal plane of an orbiting X-ray telescope where it offers several advantages over conventional spectrometers, i.e., mechanical simplicity, high resolving power and sensitivity, simultaneous measurement of an extended segment of spectrum, and good imaging properties. The instrument features a simple, unambiguous, non-scanning spectrum readout that is not adversely affected by either spacecraft pointing error or source extent. The performance of the instrument is estimated in the context of the Advanced X-Ray Astrophysical Facility mission.

Schnopper, H. W.↗

The Crimean Solar Maximum Year Workshop, selected reports

Problems associated with the transport of energy and acceleration of charged particles in solar flares are considered. Existing theories are compared with observation with a view to either discriminating between rival theories (such as whether hard X-rays are emitted by thermal or nonthermal bremsstrahlung), constraining existing theories (such as deduction of the number of nonthermal electrons present from spectroscopic diagnostics in the soft X-ray part of the spectrum), or suggesting theories (such as attempting to explain the observed spatial structure of microwave emission relative to alpha).

Emslie, A. G.↗

Observations of the hard X-ray spectrum of the impulsive phase of solar flares

The impulsive solar hard X-ray spectrum provides a direct diagnostic on the impulsive energy release of the flare. The data from the hard X-ray (14-342 keV) spectrometer on OSO 7 have been examined for events covering a wide energy range to determine the photon spectrum more precisely. This resulted in a sample of 38 events. The data have been fitted with either single- or double-power laws, and with an exponential spectrum, as from thermal bremsstrahlung. The chi-squared statistic between two-parameter fits strongly favors the exponential fit, particularly at peak intensity when the widest energy range is sampled. This result supports a single-temperature thermal source of the impulsive solar hard X-rays with temperatures in the range 4.7-31 keV and emission measures in the range from 8.4 x 10 to the 43rd to 6.0 x 10 to the 46th per cu cm. The temperature reaches a single maximum and then rapidly decays, but the emission measure usually increases throughout, even after temperature maximum, for data with 10-s resolution.

Elcan, M. J.↗

Soft X-ray flare spectra

Large solar flares produce intense soft X-ray emission, indicating the existence of high temperature plasmas that coexist in time with the plasmas responsible for the normally observed brightenings in H-alpha. The time behavior of the X-ray flux, as revealed, for example, by ion chamber detectors on the series of Solrad monitoring satellites, appears to roughly mimic the intensity-time behavior of the H-alpha flare, insofar as start times, times of maximum flux, and approximate decay times are concerned. In recent years, soft X-ray spectra of both active regions and solar flares have been obtained by instruments flown on spacecraft such as the Orbiting Solar Observatory (OSO) series. The disbursing elements used were Bragg crystals, and in the 8 Angstrom region the resolution is typically approximately 1200. This paper discusses the observed characteristics of X-ray flare spectra and spectroscopic diagnostics for determining electron temperatures, electron densities, and departures from ionization equilibrium within the soft X-ray emitting plasma.

Doschek, G. A.↗

High resolution X-ray optics for astronomical and laboratory sources

In recent years X-ray telescopes have been used successfully for high resolution observations of astronomical objects, in particular the solar corona. At the present time X-ray microscopes are being developed for diagnostics of laser and electron beam induced fusion plasmas. This paper describes both types of imaging systems using as examples the AS&E X-ray telescope on Skylab and a 10X microscope being built for Los Alamos Scientific Laboratories. The designs, manufacturing tolerances, fabrication, testing, and performance are discussed. Steps for further development in both imaging areas are identified.

Silk, J. K.↗

Magnetohydrodynamic models of coronal transients in the meridional plane. II - Simulation of the coronal transient of 1973 August 21

A two-dimensional planar MHD model of solar atmospheric transient events is used to simulate the flare-associated events of August 21, 1973. This event, observed in H-alpha, He II 304 A, soft X-ray, and coronal white light, provided sufficient information (especially in the latter diagnostic) for an assessment to be made of the model's ability to simulate major features of an actual solar event. It was found that a thermodynamic input pulse based on data provided by the NASA Marshall Space Flight Center-Aerospace Corporation X-ray telescope (S-056) on Skylab was sufficient to produce the global geometry, shock and contact-surface velocities, excess mass contours, and energy budget which were, for the most part, observed by the High Altitude Observatory white-light coronagraph (S-052) on Skylab in the form of a forerunner and coronal transient.

Dryer, M.↗

Lyman-alpha emission from nonthermal proton beams

Nonthermal fast protons penetrating an atmosphere containing neutral hydrogen will produce some nonthermal fast neutrals which will radiate Doppler-shifted photons. The hydrogen line profiles observed from such an atmosphere will thus have nonthermal, partially polarized wings that contain information on the flux, energy spectrum, and direction of the incident proton beam. This paper develops the theory of this effect and applies it to proton beams from impulsive solar flares impacting on the sun's atmosphere. Calculations of the L-alpha profile from the region of impact have been made for the Vernazza-Avrett-Loeser solar atmosphere assuming proton energy fluxes and power-law spectra similar to those inferred for the electron beams believed responsible for hard X-ray bursts. The resulting profiles show that the effect should be detectable and that it could serve as a diagnostic for flare protons near their place of origin on the sun.

Orrall, F. Q.↗

The Apollo 15 and 16 X-ray fluorescence experiment

An X-ray fluorescence spectrometer was flown aboard the Apollo 15 and 16 spacecrafts orbiting the moon. The X-ray instrument was used to produce a chemical map of that portion of the moon covered by the projected ground tracks and illuminated by the sun during the period of flight. The instrument includes three thin windowed proportional counters, two of which have selected X-ray filters. The field of view of the surface is determined by a collimator, while a detector on the opposite side of the spacecraft provides a continuous monitoring of the solar X-ray output. While the number of chemical elements determined was limited to Mg, Al, and Si, these proved to be very important diagnostic elements.

Adler, I.↗

Auroral mechanisms and morphology

The present review is concerned with observations, analysis of observations and theoretical work as related to the understanding of the aurora. The ground-based observations reviewed include (1) auroral imagery, both by television and all-sky camera; (2) gross magnetic variations indicative of ionospheric currents; (3) VLF hiss observations; and (4) effects of high-energy electron impact measured through cosmic radio noise absorption and by observations of bremsstrahlung X-ray from balloons. Spectroscopic observations, observation of micropulsation activity and auroral radar observations are not included, since they seem to provide less direct diagnostic information on the basic auroral mechanism. Incoherent scatter radar observations are utilized to the extent they provide information on ionospheric currents and electric fields. Satellite observations are included to the extent they provide information on the aurora or useful clues to auroral mechanisms. Barium injection experiments in the auroral zone are also considered.

Swift, D. W.↗

Three-dimensional reconstruction and display of the heart, lungs and circulation by multiplanar X-ray scanning videodensitometry

A device was developed which makes possible the dynamic reconstruction of the heart and lungs within the intact thorax of a living dog or human and which can record approximately 30 multiplanar X-ray images of the thorax practically instantaneously, and at frequent enough intervals of time and with sufficient density and spatial resolution to capture and resolve the most rapid changes in cardiac structural detail throughout each cardiac cycle. It can be installed in a clinical diagnostic setting as well as in a research environment and its construction and application for determination and display in real-time modes of cross sections of the functioning thorax and its contents of living animals and man is technologically feasible.

Robb, R. A.↗

Polar 5 - An electron accelerator experiment within an aurora. I - Instrumentation and geophysical conditions

A mother-daughter rocket was launched over two auroral structures, which included a 10 keV electron accelerator and a series of diagnostic instruments for monitoring optical and wave effects generated through beam-atmospheric interactions and production of secondary electrons. The instrumentation, the ground and rocket background measurements obtained, and some of the beam effects on various geophysical parameters are presented. Attention is given to the rocket geometry, capacitance probe, particle counters, photometers, and the bremsstrahlung X-ray detector. Observations on the plasma environment, auroral particle precipitation, d.c. electric field, optical emissions, and auroral background HF and VLF emissions are also discussed.

Maehlum, B. N.↗

Dense plasma focus production in a hypocycloidal pinch

A type of high-power pinch apparatus consisting of disk electrodes was developed, and diagnostic measurements to study its mechanism of dense plasma production were made. The collapse fronts of the current sheets are well organized, and dense plasma focuses are produced on the axis with radial stability in excess of 5 microns. A plasma density greater than 10 to the 18th power/cubic cm was determined with Stark broadening and CO2 laser absorption. A plasma temperature of approximately 1 keV was measured with differential transmission of soft X-rays through thin foils. Essentially complete absorption of a high-energy CO2 laser beam was observed. The advantages of this apparatus over the coaxial plasma focus are in (1) the plasma volume, (2) the stability, (3) the containment time, (4) the easy access to additional heating by laser or electron beams, and (5) the possibility of scaling up to a multiple array for high-power operation.

Lee, J. H.↗

Computerized X-ray reconstruction tomography in stereometric analysis of cardiovascular dynamics

A computerized technique is proposed for obtaining cross-sectional images of the dynamic spatial distribution of X-ray attenuation covering the entire anatomic extent of the thorax and its contents in living dogs with a resolution of 1 mm and at time intervals of 1/60 sec. Use is made of an X-ray imaging chain which is a new high-performance video-fluoroscopic system, unique in its design and construction and called SSDSR for single source dynamic spatial reconstructor. This dynamic spatial reconstruction system is shown to provide the temporally and spatially coherent multiple cross sections required to obtain the full three-dimensional anatomic and simultaneous hemodynamic information necessary for detailed quantitative analyses of regional cardiopulmonary and vascular functions in both basic investigations of animals and clinical diagnostic applications to patients. Numerous photographs supplement the text.

Robb, R. A.↗

High temperature UF6 and plasma research

Research currently under way on technology for uranium plasma core reactors is reviewed. A feeder system to provide a controlled and steady flow of UF6 at rates up to 5 g/sec and temperatures up to 500 K into rf plasma test chambers operating at pressures of up to 20 atm has been developed. Plasma emission and dye laser absorption measurements have been used to estimate the radial distribution of uranium atom number density within the plasma. X-ray absorption equipment and techniques have also been employed to measure the amount of uranium in the plasma, and dc plasma torch experiments have shown variations in plasma VUV emission with temperature. Analysis of residues deposited on various test-chamber components after plasma tests reveals traces of several uranium oxides, including UO2F2, and various exhaust duct configurations with flow augmentation are under investigation as means of preventing uranium deposition. Other areas of research include off- and on-line exhaust gas diagnostics, and a UF6/Ar injection, separation and recirculation system.

Roman, W. C.↗

Production of dense plasmas in a hypocycloidal pinch apparatus

A high-power pinch apparatus consisting of disk electrodes was developed, and diagnostic measurements to study its mechanism of dense plasma production have been made. The collapse fronts of the current sheets are well organized, and dense plasma foci are produced on the axis with radial stability in excess of 5 microsec. A plasma density greater than 10 to the 18th power per cu cm is determined with Stark broadening and CO2 laser absorption. Essentially complete absorption of a high-energy CO2 laser beam has been observed. A plasma temperature of approximately 1 keV is measured with differential transmission of soft X-rays through thin foils. The advantages of this apparatus over the coaxial plasma focus are improvements in (1) plasma volume, (2) stability, (3) containment time, (4) access to additional heating by laser or electron beams, and (5) the possibility of scaling up to a multiple array for high-power operation.

Lee, J. H.↗

A survey of X-ray line emission from the supernova remnant Puppis A

Initial results from the first high-resolution study of the X-ray spectrum of a supernova remnant are reported. The spectrum of Puppis A between 500 and 1100 eV has been surveyed with the Focal Plane Crystal Spectrometer on the Einstein Observatory and the flux in eight lines and three line blends from various transitions of highly ionized nitrogen, oxygen, neon, and iron has been measured. The spectrum resembles that of active regions in the solar corona, but the neon lines seem enhanced relative to the oxygen lines, and both are enhanced relative to iron. The observed line strengths serve as diagnostics of the physical conditions in the emitting material. Without a priori assumptions, the ionization temperatures of O (2.2 million K) and Ne (4 million K) and the dominant ionization stage of Fe (Fe XVII) are deduced. Isothermal equilibrium plasmas or homogeneous nonequilibrium plasmas as descriptions of the source are ruled out. It is concluded that Puppis A must contain plasma over a temperature range 2-million to 5-million K with an intervening absorption column of 4 x 10 to the 21st/sq cm.

Winkler, P. F.↗