Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray microdiffraction strain/stress”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Superbend X-Ray Microdiffraction Beamline at the Advanced Light Source

Beamline 12.3.2 at the Advanced Light Source is a newly commissioned beamline dedicated to x-ray microdiffraction. It operates in both monochromatic and polychromatic radiation mode. The facility uses a superconducting bending magnet source to deliver an X-ray spectrum ranging from 5 to 22 keV. The beam is focused down to {approx} 1 um size at the sample position using a pair of elliptically bent Kirkpatrick-Baez mirrors enclosed in a vacuum box. The sample placed on high precision stages can be raster-scanned under the microbeam while a diffraction pattern is taken at each step. The arrays of diffraction patterns are then analyzed to derive distribution maps of phases, strain/stress and/or plastic deformation inside the sample.

36 MATERIALS SCIENCE↗

Mechanism of heat affected zone cracking in Ni-based superalloy DZ125L fabricated by laser 3D printing technique

Laser 3D printing is a promising technique to repair damaged Ni-based superalloy components. However, the occurrence of heat affected zone (HAZ) cracking severely limits its applicability. In this paper, we unravel the cracking mechanism by studying the element, phase, defect, and strain distribution around an intergranular crack that initiated from the primary HAZ. Using synchrotron X-ray Laue microdiffraction, we measured high tensile strain/stress transverse to the building direction in both the primary HAZ and the cladding layers, as well as high-density dislocations, which resulted from the thermal contraction and rapid precipitation of γ' phase. The crack initiated because the transverse tensile strain/stress tore up the liquid film formed by the low-melting point preexisting phases in the primary HAZ, such as γ/γ' eutectics and coarse γ' precipitates. The incoherent carbide particles were frequently observed near the crack root as local strain concentrators. In the cladding layers, micro-segregation could not be completely avoided, thus the hot crack continued to propagate over several layers with the assistance of the transverse tensile stress. Finally, our investigations provide a useful guideline for the optimization of the 3D printing process to repair Ni-based superalloys with high susceptibility to hot cracking.

36 MATERIALS SCIENCE↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend) This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 mu m spot of ~;;5x109 photons/ s (0.1percent bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored bytwo pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 um are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution (~;;0.2 mu m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10-5 strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution (~;;150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

47 OTHER INSTRUMENTATION↗

A dedicated superbend x-ray microdiffraction beamline for materials, geo-, and environmental sciences at the advanced light source

A new facility for microdiffraction strain measurements and microfluorescence mapping has been built on beamline 12.3.2 at the advanced light source of the Lawrence Berkeley National Laboratory. This beamline benefits from the hard x-radiation generated by a 6 T superconducting bending magnet (superbend). This provides a hard x-ray spectrum from 5 to 22 keV and a flux within a 1 {mu}m spot of {approx}5x10{sup 9} photons/s (0.1% bandwidth at 8 keV). The radiation is relayed from the superbend source to a focus in the experimental hutch by a toroidal mirror. The focus spot is tailored by two pairs of adjustable slits, which serve as secondary source point. Inside the lead hutch, a pair of Kirkpatrick-Baez (KB) mirrors placed in a vacuum tank refocuses the secondary slit source onto the sample position. A new KB-bending mechanism with active temperature stabilization allows for more reproducible and stable mirror bending and thus mirror focusing. Focus spots around 1 {mu}m are routinely achieved and allow a variety of experiments, which have in common the need of spatial resolution. The effective spatial resolution ({approx}0.2 {mu}m) is limited by a convolution of beam size, scan-stage resolution, and stage stability. A four-bounce monochromator consisting of two channel-cut Si(111) crystals placed between the secondary source and KB-mirrors allows for easy changes between white-beam and monochromatic experiments while maintaining a fixed beam position. High resolution stage scans are performed while recording a fluorescence emission signal or an x-ray diffraction signal coming from either a monochromatic or a white focused beam. The former allows for elemental mapping, whereas the latter is used to produce two-dimensional maps of crystal-phases, -orientation, -texture, and -strain/stress. Typically achieved strain resolution is in the order of 5x10{sup -5} strain units. Accurate sample positioning in the x-ray focus spot is achieved with a commercial laser-triangulation unit. A Si-drift detector serves as a high-energy-resolution ({approx}150 eV full width at half maximum) fluorescence detector. Fluorescence scans can be collected in continuous scan mode with up to 300 pixels/s scan speed. A charge coupled device area detector is utilized as diffraction detector. Diffraction can be performed in reflecting or transmitting geometry. Diffraction data are processed using XMAS, an in-house written software package for Laue and monochromatic microdiffraction analysis.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantitative Scanning Laue Diffraction Microscopy: Application to the Study of 3D Printed Nickel-Based Superalloys

Progress in computing speed and algorithm efficiency together with advances in area detector and X-ray optics technologies have transformed the technique of synchrotron radiation-based scanning Laue X-ray microdiffraction. It has now evolved into a near real-time quantitative imaging tool for material structure and deformation at the micrometer and nanometer scales. We will review the achievements of this technique at the Advanced Light Source (Berkeley, CA, USA), and demonstrate its application in the thorough microstructural investigations of laser-assisted 3D printed nickel-based superalloys.

36 MATERIALS SCIENCE↗

Statistical study of ductility-dip cracking induced plastic deformation in polycrystalline laser 3D printed Ni-based superalloy

Ductility-dip cracking in Ni-based superalloy, resulting from heat treatment, is known to cause disastrous failure, but its mechanism is still not completely clear. A statistical study of the cracking behavior as a function of crystal orientation in a laser 3D-printed DL125L Ni-based superalloy polycrystal is investigated here using the synchrotron X-ray microdiffraction. The dislocation slip system in each of the forty crystal grains adjacent to the 300 μm long crack has been analyzed through Laue diffraction peak shapes. In all these grains, edge-type geometrically necessary dislocations (GNDs) dominate, and their dislocation line directions are almost parallel to the crack plane. Based on Schmid's law, the equivalent uniaxial tensile force direction is revealed normal to the trace of the crack. A qualitative mechanism is thus proposed. Thermal tensile stress perpendicular to the laser scanning direction is elevated due to a significant temperature gradient, and thus locations in the materials where the thermal stress exceeds the yield stress undergo plastic deformation mediated by GND activations. As the dislocations slip inside the crystal grains and pile up at the grain boundaries, local strain/stress keeps increasing, until the materials in these regions fail to sustain further deformation, leading to voids formation and cracks propagation.

36 MATERIALS SCIENCE↗

New Structural Insight into Interface-Controlled α–σ Phase Transformation in Fe-Cr Alloys

Synchrotron Laue microdiffraction scanning is used for the ex situ study of the body-centered, cubic-to-tetragonal phase transformation that occurs in equiatomic polycrystalline Fe-Cr alloys at temperatures between 550 and 800 °C. Grain orientation and grain strains were scanned with a micron step resolution after annealing at 700 °C for 12 h. Further microstructural details on the early stage of the transformation, and more particularly on the cubic-to-tetragonal phase interface, were achieved. Only the α and ordered σ phases were detected. The crystallographic relationships at the interface between the two phases did not follow the predicted rules; this result is discussed in relation to the measured microstrains.

36 MATERIALS SCIENCE↗

Microstructure and residual elastic strain at graphite nodules in ductile cast iron analyzed by synchrotron X-ray microdiffraction

The microstructure and residual elastic strain at graphite nodules (GNs) in ductile cast iron produced using either a fast or slow cooling rate have been characterized using synchrotron 3D X-ray Laue microdiffraction. The results demonstrate that thermal stress is introduced during cooling and that part of this stress is relaxed by plastic deformation of the polycrystalline ferrite matrix. It is observed that the plastic deformation is accommodated by the formation of dislocations and dislocation boundaries, which are organized in a cell structure. The dislocation density quantified based on the microstructure is most pronounced at the GN/matrix interface around small GNs in the fast cooled sample. Residual elastic strain is also present, which is mainly compressive with a maximum of 6.0–9.9 × 10 -4 near the GNs. Gradients of plastic deformation and elastic strain field around the GNs are observed. The results document for the first time that both the elastic strain field and the plastic strain field averaged over the grains around the GNs is approximately scaling with GN size and not affected by the cooling rate. The experimental data are compared with simulations by a finite element method, and agreement and disagreement are considered in detail.

36 MATERIALS SCIENCE↗