Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray optics full shell”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Characterization of multilayer coated replicated Wolter optics for imaging x-ray emission from pulsed power

Here, we have developed a process for indirectly coating small diameter electroformed nickel replicated optics with multilayers to increase their response at high energy (i.e. >10 keV). The ability to fabricate small diameter multilayer-coated full-shell Wolter X-ray optics with narrow bandpass opens the door to several applications within astronomy and also provides a path for cross-fertilization to other fields. We report on the characterization and evaluation of the first two prototype X-ray Wolter optics to be delivered to the Z Pulsed Power Facility at Sandia National Laboratories. The intent is to develop and field several optics as part of an imaging system with targeted spectral ranges.

36 MATERIALS SCIENCE↗

The role of the dopant in the electronic structure of erbium-doped TiO 2 for quantum emitters

Erbium-doped TiO 2 materials are promising candidates for advancing quantum technologies, necessitating a thorough understanding of their electronic and crystal structures to tailor their properties and enhance coherence times. This study explored epitaxial erbium-doped rutile TiO 2 films deposited on r-sapphire substrates using molecular beam epitaxy. Photoluminescence excitation spectroscopy demonstrated decreasing photoluminescence lifetimes with erbium doping, indicating limited optical coherence times. Lattice distortions associated with Er 3+ were probed by x-ray absorption spectroscopy, indicating that erbium primarily occupies Ti 4+ sites and influences oxygen vacancies. Significant lattice distortions in the higher-order shells and apparent full coordination around erbium suggest that additional defects are likely prevalent in these regions. These findings indicate that defects contribute to limited coherence times by introducing alternative decay pathways, leading to shorter photoluminescence lifetimes.

Crystallographic defects↗

Spectroscopic study of temperature and density spatial profiles and mix in implosion cores

New techniques of x-ray spectroscopy have been developed to extract the temperature and density spatial structure of implosion cores. Results from an emissivity analysis, which neglects optical depth effects, compare well with the independent results of an intensity analysis used in the low optical depth limit. The intensity analysis has also been applied in its full form, in which case density spatial profiles demonstrate significant opacity effects. The emissivity and intensity analyses were combined to infer the spatial profile of mixing between shell and fuel material. This experimentally-derived information on mix is compared with predictions from two standard theoretical mix models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct deconvolution of two-state pump-probe x-ray absorption spectra and the structural changes in a 100 ps transient of Ni(II)-tetramesitylporphyrin.

Full multiple scattering (FMS) Minuit XANES (MXAN) has been combined with laser pump-probe K-edge X-ray absorption spectroscopy (XAS) to determine the structure of photoexcited Ni(II)tetramesitylporphyrin, Ni(II)TMP, in dilute toluene solution. It is shown that an excellent simulation of the XANES spectrum is obtained, excluding the lowest-energy bound-state transitions. In ground-state Ni(II)TMP, the first-shell and second-shell distances are, respectively, d(Ni-N) = (1.93 {+-} 0.02) {angstrom} and d(Ni-C) = (2.94 {+-} 0.03) {angstrom}, in agreement with a previous EXAFS result. The time-resolved XANES difference spectrum was obtained from the spectra of Ni(II)TMP in its photoexcited T{sub 1} state and its ground state, S{sub 0}. The XANES difference spectrum has been analyzed to obtain both the structure and the fraction of the T{sub 1} state. If the T{sub 1} fraction is kept fixed at the value (0.37 {+-} 0.10) determined by optical transient spectroscopy, a 0.07 {angstrom} elongation of the Ni-N and Ni-C distances [d(Ni-N) and d(Ni-C)] is found, in agreement with the EXAFS result. However, an evaluation of both the distance elongation and the T{sub 1} fraction can also be obtained using XANES data only. According to experimental evidence, and MXAN simulations, the T{sub 1} fraction is (0.60 {+-} 0.15) with d(Ni-N) = (1.98 {+-} 0.03) {angstrom} (0.05 {angstrom} elongation). The overall uncertainty of these results depends on the statistical correlation between the distances and T{sub 1} fraction, and the chemical shift of the ionization energy because of subtle changes of metal charge between the T{sub 1} and S{sub 0} states. The T{sub 1} excited-state structure results, independently obtained without the excited-state fraction from optical transient spectroscopy, are still in agreement with previous EXAFS investigations. Thus, full multiple scattering theory applied through the MXAN formalism can be used to provide structural information, not only on the ground-state molecules but also on very short-lived excited states through differential analysis applied to transient photoexcited species from time-resolved experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Toward the fabrication of a 5- μm -resolution Wolter microscope for the National Ignition Facility (invited)

Advancements in computer-controlled polishing, metrology, and replication have led to an x-ray mirror fabrication process that is capable of producing high-resolution Wolter microscopes. Here, we present the fabrication and test of a nickel–cobalt replicated full-shell x-ray mirror that was electroformed from a finely figured and polished mandrel. This mandrel was designed for an 8-m source-to-detector-distance microscope, with 10× magnification, and was optimized to reduce shell distortions that occur within 20 mm of the shell ends. This, in combination with an improved replication tooling design and refined bath parameters informed by a detailed COMSOL Multiphysics® model, has led to reductions in replication errors in the mirrors. Mandrel surface fabrication was improved by implementing a computer-controlled polishing process that corrected the low-frequency mandrel figure error and achieved <2.0 nm RMS convergence error. X-ray tests performed on a pair of mirror shells replicated from the mandrel have demonstrated <10 μm full-width at half-maximum (FWHM) spatial resolution. Here, we discuss the development process, highlight results from metrology and x-ray testing, and define a path for achieving a program goal of 5 μm FWHM resolution.

47 OTHER INSTRUMENTATION↗

Single-shot structural analysis by high-energy X-ray diffraction using an ultrashort all-optical source

High-energy X-rays (HEX-rays) with photon energies on order of 100 keV have attractive characteristics, such as comparably low absorption, high spatial resolution and the ability to access inner-shell states of heavy atoms. These properties are advantageous for many applications ranging from studies of bulk materials to the investigation of materials in extreme conditions. Ultrafast X-ray diffraction allows the direct imaging of atomic dynamics simultaneously on its natural time and length scale. However, using HEX-rays for ultrafast studies has been limited due to the lack of sources that can generate pulses of sufficiently short (femtosecond) duration in this wavelength range. Here we show single-crystal diffraction using ultrashort ~90 keV HEX-ray pulses generated by an all-optical source based on inverse Compton scattering. We also demonstrate a method for measuring the crystal lattice spacing in a single shot that contains only ~10 5 photons in a spectral bandwidth of ~50% full width at half maximum (FWHM). Our approach allows us to obtain structural information from the full X-ray spectrum. As target we use a cylindrically bent Ge crystal in Laue transmission geometry. As a result, this experiment constitutes a first step towards measurements of ultrafast atomic dynamics using femtosecond HEX-ray pulses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sub-keV design for the National Ignition Facility’s soft x-ray Opacity Spectrometer (OpSpec) and expansion plans for time-resolved measurements

When compared with the National Ignition Facility’s (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520–1100 eV. When coupled with the primary elliptical geometry, which spans 1000–2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ~1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. Here, the new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

47 OTHER INSTRUMENTATION↗

The effects of convergence ratio on the implosion behavior of DT layered inertial confinement fusion capsules

The wetted foam capsule design for inertial confinement fusion capsules, which includes a foam layer wetted with deuterium-tritium liquid, enables layered capsule implosions with a wide range of hot-spot convergence ratios (CR) on the National Ignition Facility. In this paper, we present a full-scale wetted foam capsule design that demonstrates high gain in one-dimensional simulations. In these simulations, increasing the convergence ratio leads to an improved capsule yield due to higher hot-spot temperatures and increased fuel areal density. High-resolution two-dimensional simulations of this design are presented with detailed and well resolved models for the capsule fill tube, support tent, surface roughness, and predicted asymmetries in the x-ray drive. Our modeling of these asymmetries is validated by comparisons with available experimental data. In 2D simulations of the full-scale wetted foam capsule design, jetting caused by the fill tube is prevented by the expansion of the tungsten-doped shell layer due to preheat. While the impacts of surface roughness and predicted asymmetries in the x-ray drive are enhanced by convergence effects, likely underpredicted in 2D at high CR, simulations predict that the capsule is robust to these features. Nevertheless, the design is highly susceptible to the effects of the capsule support tent, which negates all of the one-dimensional benefits of increasing the convergence ratio. Indeed, when the support tent is included in simulations, the yield decreases as the convergence ratio is increased for CR > 20. Finally and nevertheless, the results suggest that the full-scale wetted foam design has the potential to outperform ice layer capsules given currently achievable levels of asymmetries when fielded at low convergence ratios (CR < 20).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence of Extreme Ultraviolet Superfluorescence in Xenon

We present a comprehensive experimental and theoretical study on superfluorescence in the extreme ultraviolet wavelength regime. Focusing a free-electron laser pulse in a cell filled with Xe gas, the medium is quasi-instantaneously population inverted by 4d-shell ionization on the giant resonance followed by Auger decay. On the timescale of ~10 ps to ~100 ps (depending on parameters) a macroscopic polarization builds up in the medium, resulting in superfluorescent emission of several Xe lines in the forward direction. As the number of emitters in the system is increased by either raising the pressure or the pump-pulse energy, the emission yield grows exponentially over four orders of magnitude and reaches saturation. With increasing yield, we observe line broadening, a manifestation of superfluorescence in the spectral domain. Here, our novel theoretical approach, based on a full quantum treatment of the atomic system and the irradiated field, shows quantitative agreement with the experiment and supports our interpretation.

74 ATOMIC AND MOLECULAR PHYSICS↗