Three-dimensional nanoscale reduced-angle ptycho-tomographic imaging with deep learning (RAPID)

X-ray ptychographic tomography is a nondestructive method for three dimensional (3D) imaging with nanometer-sized resolvable features. The size of the volume that can be imaged is almost arbitrary, limited only by the penetration depth and the available scanning time. Here we present a method that rapidly accelerates the imaging operation over a given volume through acquiring a limited set of data via large angular reduction and compensating for the resulting ill-posedness through deeply learned priors. The proposed 3D reconstruction method “RAPID” relies initially on a subset of the object measured with the nominal number of required illumination angles and treats the reconstructions from the conventional two-step approach as ground truth. It is then trained to reproduce equal fidelity from much fewer angles. After training, it performs with similar fidelity on the hitherto unexamined portions of the object, previously not shown during training, with a limited set of acquisitions. In our experimental demonstration, the nominal number of angles was 349 and the reduced number of angles was 21, resulting in a x140 aggregate speedup over a volume of 4.48 x 93.18 x 3.92 μm 3 and with (14nm) 3 feature size, i.e. ~ 10 8 voxels. RAPID’s key distinguishing feature over earlier attempts is the incorporation of atrous spatial pyramid pooling modules into the deep neural network framework in an anisotropic way. We found that adjusting the atrous rate improves reconstruction fidelity because it expands the convolutional kernels’ range to match the physics of multi-slice ptychography without significantly increasing the number of parameters.

47 OTHER INSTRUMENTATION↗

Hints of Growth Mechanism Left in Supercrystals

Supercrystals of DNA-functionalized nanoparticles arevisualizedin three dimensions using X-ray ptychographic tomography, and theirreciprocal spaces are mapped with small-angle X-ray scattering inorder to better understand their internal defect structures. X-rayptychographic tomography reveals various types of defects in an assemblythat otherwise exhibits a single crystalline diffraction pattern.On average, supercrystals composed of smaller nanoparticles are smallerin size than supercrystals composed of larger particles. Additionally,supercrystals composed of small nanoparticles are typically aggregatedinto larger "necklace-like" structures. Within theselarger structures, some but not all pairs of connected domains arecoherent in their relative orientations. In contrast, supercrystalscomposed of larger nanoparticles with longer DNA ligands typicallyform faceted crystals. The combination of these two complementaryX-ray techniques reveals that the crystalline assemblies grow by aggregationof smaller assemblies followed by rearrangement of nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic sparse x-ray nanotomography reveals ionomer hydration mechanism in polymer electrolyte fuel-cell catalyst

Tomographic imaging of time-evolving samples is a challenging yet important task for various research fields. At the nanoscale, current approaches face limitations of measurement speed or resolution due to lengthy acquisitions. We developed a dynamic nanotomography technique based on sparse dynamic imaging and 4D tomography modeling. We demonstrated the technique, using ptychographic x-ray computed tomography as its imaging modality, on resolving the in situ hydration process of polymer electrolyte fuel cell (PEFC) catalyst. The technique provides a 40-time increase in temporal resolution compared to conventional approaches, yielding 28 nm half-period spatial and 12 min temporal resolution. The results allow a quantitative characterization of the water intake process inside PEFC catalysts with nanoscale resolution, which is crucial for understanding their electrochemical mechanisms and optimizing their performance. Our technique enables high-speed operando nanotomography studies and paves the way for wider application of dynamic tomography at the nanoscale.

Science & Technology - Other Topics↗

Determining the nanostructure of polymer foams using 3D ptycho-tomography for inertial fusion energy applications

Polymer foams play a critical role in contemporary inertial fusion energy (IFE) target designs by enhancing energy yield and optimizing implosion dynamics. However, the lack of high-resolution characterization of the nanostructure of these foams restricts progress in fusion science. In this work, we demonstrate the first high-resolution three-dimensional (3D) reconstruction of a low-density, Si-doped polymer foam fabricated via two-photon polymerization, using ptychographic x-ray computed tomography (PXCT) at an x-ray free electron laser (XFEL). This imaging method reconstructs two-dimensional (2D) attenuation and phase information at multiple sample angles that are combined into a 3D density map used to extract local mass density and determine structural dimensions. We achieve a 2D spatial resolution of 19 ± 3 nm on a high-contrast Ronchi pattern target and 78.7 ± 3 nm for low-contrast polymer foams, marking a significant advancement for XFEL-based ptychography of low-density materials. Furthermore, our experimental results reveal an average foam strut thickness of 1.17 ± 0.4 μm, consistent with fabrication expectations, and a reconstructed average mass density of 0.35 g/cc, aligning closely with the predicted density of 0.29 g/cc. These findings provide important insights for improving foam design and refining radiation hydrodynamics modeling in future IFE experiments. Our study establishes PXCT at an XFEL as a powerful tool for high-resolution characterization of fusion-relevant materials, paving the way for enhanced target performance in IFE research.

Hancock, Levi [Colorado State Univ., Fort Collins,↗

Self-Assembled Magnetic Nanoparticle Layers: Structural Control for Reconfigurable Magnetism and Functional Applications

We advance soft X-ray vector ptychographic tomography to map the 3D magnetization field in self-assembled superparamagnetic nanoparticles at a liquid–liquid interface, revealing how layered structures influence magnetic ordering. We observe that monolayers with low coordination numbers exhibit weak magnetic order, with magnetic vortices disrupting spin alignment. In contrast, bilayers and trilayers with higher coordination numbers display long-range magnetic order with strong spin correlations across larger distances and a suppression of magnetic vortices. We further quantify the average distance for vortex–antivortex pairs as 26.0 ± 2.0 nm, while vortex–vortex and antivortex–antivortex pairs exhibit larger separations, averaging 44.9 ± 5.2 and 54.1 ± 7.4 nm, respectively. These experimental results are supported by micromagnetic Monte Carlo simulations. Our findings illustrate how layered structures enhance magnetic order and spin correlation in superparamagnetic nanoparticle assemblies, providing a promising approach for tuning magnetic properties in applications such as data storage, microrobotics, and biomedicine.

Lu, Xingyuan↗

Evaluating multi-slice ptychography tomography for X-ray imaging

X-ray ptychography typically relies on single-slice reconstruction approaches that assume minimal beam propagation through the specimen. However, this approximation breaks down for thick samples or when using high numerical aperture optics, leading to reconstruction artifacts due to multiple scattering. Multi-slice ptychographic tomography (MSPT) addresses this limitation by explicitly modeling beam propagation through the specimen while reducing angular sampling requirements for tomography, but its performance depends critically on reconstruction parameters and experimental conditions. Here, we systematically evaluate MSPT using numerical simulations and experimental X-ray datasets to understand how factors such as object thickness, optical parameters, and initialization strategies affect reconstruction accuracy. We demonstrate that informed object initialization significantly improves depth resolution and enables accurate projection extension, reducing the angular sampling requirements for tomographic reconstruction. Experimental demonstration confirms that MSPT produces reconstructions with reduced artifacts, establishing it as a robust approach for nanoscale imaging at modern synchrotron facilities.

Luktuke, Amey [Argonne National Laboratory (ANL), ↗

Attentional Ptycho-Tomography (APT) for three-dimensional nanoscale X-ray imaging with minimal data acquisition and computation time

Abstract Noninvasive X-ray imaging of nanoscale three-dimensional objects, such as integrated circuits (ICs), generally requires two types of scanning: ptychographic, which is translational and returns estimates of the complex electromagnetic field through the IC; combined with a tomographic scan, which collects these complex field projections from multiple angles. Here, we present Attentional Ptycho-Tomography (APT), an approach to drastically reduce the amount of angular scanning, and thus the total acquisition time. APT is machine learning-based, utilizing axial self-Attention for Ptycho-Tomographic reconstruction. APT is trained to obtain accurate reconstructions of the ICs, despite the incompleteness of the measurements. The training process includes regularizing priors in the form of typical patterns found in IC interiors, and the physics of X-ray propagation through the IC. We show that APT with ×12 reduced angles achieves fidelity comparable to the gold standard Simultaneous Algebraic Reconstruction Technique (SART) with the original set of angles. When using the same set of reduced angles, then APT also outperforms Filtered Back Projection (FBP), Simultaneous Iterative Reconstruction Technique (SIRT) and SART. The time needed to compute the reconstruction is also reduced, because the trained neural network is a forward operation, unlike the iterative nature of these alternatives. Our experiments show that, without loss in quality, for a 4.48 × 93.2 × 3.92 µm 3 IC (≃6 × 10 8 voxels), APT reduces the total data acquisition and computation time from 67.96 h to 38 min. We expect our physics-assisted and attention-utilizing machine learning framework to be applicable to other branches of nanoscale imaging, including materials science and biological imaging.

47 OTHER INSTRUMENTATION↗

3D and Multimodal X‐Ray Microscopy Reveals the Impact of Voids in CIGS Solar Cells

Small voids in the absorber layer of thin-film solar cells are generally suspected to impair photovoltaic performance. They have been studied on Cu(In,Ga)Se 2 cells with conventional laboratory techniques, albeit limited to surface characterization and often affected by sample-preparation artifacts. Here, synchrotron imaging is performed on a fully operational as-deposited solar cell containing a few tens of voids. By measuring operando current and X-ray excited optical luminescence, the local electrical and optical performance in the proximity of the voids are estimated, and via ptychographic tomography, the depth in the absorber of the voids is quantified. Besides, the complex network of material-deficit structures between the absorber and the top electrode is highlighted. Despite certain local impairments, the massive presence of voids in the absorber suggests they only have a limited detrimental impact on performance.

14 SOLAR ENERGY↗