Search NASA⌕ Search

SEARCH · Search NASA

Results for “XENON LIGHT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Xenon lighting adjusted to plant requirements

Xenon lamps are available as low and high power lamps with relatively high efficiency and a relatively long lifetime up to several thousand hours. Different construction types of short-arc and long-arc lamps permit a good adaptation to various applications in projection and illumination techniques without substantial changes of the spectral quality. Hence, the xenon lamp was the best choice for professional technical purposes where high power at simultaneously good spectral quality of the light was required. However, technical development does not stand still. Between the luminous efficacy of xenon lamps of 25-50 lm/W and the theoretical limit for 'white light' of 250 lm/W is still much room for improvement. The present development mainly favors other lamp types, like metal halide lamps and fluorescent lamps for commercial lighting purposes. The enclosed sections deal with some of the properties of xenon lamps relevant to plant illumination; particularly the spectral aspects, the temporal characteristics of the emission, and finally the economy of xenon lamps will be addressed. Due to radiation exceeding the natural global radiation in both the ultraviolet (UV) and the infrared (IR) regions, filter techniques have to be included into the discussion referring to the requirements of plant illumination. Most of the presented results were obtained by investigations in the GSF phytotron or in the closed Phytocell chambers of the University of Erlangen. As our experiences are restricted to area plant illumination rather than spot lights our discussion will concentrate on low pressure long-arc xenon lamps which are commonly used for such plant illuminations. As the spectral properties of short-arc lamps do not differ much from those of long-arc lamps most of our conclusions will be valid for high pressure xenon lamps too. These lamps often serve as light sources for small sun simulators and for monochromators which are used for action spectroscopy of plant responses.

Koefferlein, M.↗

UA'(1): The search for low-mass dark matter in liquid xenon / Infrared Light for Liquid Xenon TPCs

Liquid xenon-based time projection chambers are used in a variety of applications spanning from the search for dark matter or signals from coherent neutrino-nucleus scattering, to detectors used in medicine and for nuclear non-proliferation. Extending the useful energy range of these detectors down to lower energies will prove extremely useful for such applications. However, various sources of single- and few-electron backgrounds limit the utility of experiments such as LZ and XENONnT to searches of lighter dark matter articles in the MeV mass range. These same backgrounds also limit their utility to measure signals from coherent neutrino-nucleus scattering of solar boron-8 neutrinos and Galactic supernovae. This research worked on multiple mitigation strategies to reduce these backgrounds, through improved xenon purity, infrared irradiation, and an improved theoretical understanding. Multiple dedicated liquid xenon setups were built to execute those tests, and data was successfully taken. Liquid xenon purity was shown to have an important impact, but infrared irradiation did not reduce these backgrounds.

47 OTHER INSTRUMENTATION↗

High Intensity Lights

Xenon arc lamps developed during the Apollo program by Streamlight, Inc. are the basis for commercial flashlights and emergency handlights. These are some of the brightest portable lights made. They throw a light some 50 times brighter than automobile high beams and are primarily used by police and military. The light penetrates fog and smoke and returns less back-scatter light. They are operated on portable power packs as boat and auto batteries. An infrared model produces totally invisible light for covert surveillance.

Source record↗

Understanding the enhancement of scintillation light in xenon-doped liquid argon

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where ~10–1000 ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fully appreciated. This absorption significantly reduces the light yield in commercially available argon (extracted from air) which contains trace amounts (~0.1 ppm) of xenon. The addition of a small xenon dopant of ~10 ppm recovers this lost light resulting in an increased light yield over un-doped argon of about a factor of two. Here, in this paper, we introduce a model for the light production in xenon doped argon, including absorption and re-emission, and compare it to the measured time dependence of light emission in xenon-doped argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Xenon in carbonaceous chondrites.

A table showing the relative amounts of xenon isotopes in carbonaceous chondrites is presented. It is found that the enrichment of heavy xenon isotopes released from carbonaceous chondrites in the approximate temperature range from 600 to 1000 C is accompanied by an enrichment of the light xenon isotopes. The high degree of correlation between these two isotopic anomalies suggests that both result from a common source. There is no known nuclear or physical process which could produce both anomalies in situ. It is, therefore, suggested that the anomalies are the result of the release of isotopically anomalous xenon which was trapped in the meteorites.

Manuel, O. K.↗

Early Air Force Flight Test Center (AFFTC) experience with Peripheral Vision Horizon Displays (PVHD)

Three separate Air Force Flight Test Center (AFFTC) tests were conducted in 1980 and 1981 on two models of the peripheral vision horizon displays (PVHD) (Malcolm Horizon). A fixed base simulator test was conducted with twenty test pilot subjects using the Flight Simulator Demonstration Model which incorporated a Helium Neon laser as the light bar medium. Two separate flight tests were conducted by the Test Pilot School classes 80A and 80B in a Twin Otter commuter aircraft using the Stage A Model PVHD. The Xenon lighted A Model was tested in its original configuration by class 80A. Class 80B used a modified configuration which incorporated an AFFTC designed and manufactured hood. With the hood, the PVHD projected a thinner, distinct light bar. Only a few general remarks concerning the tests and unrestricted, overall conclusions reached by the author are presented. The conclusions of all three AFFTC evaluations of the PVHD concept were that it has not yet been adequately evaluated. There seems to be a significant learning curve associated with the PVHD and the project pilots for Test Pilot School Class 80B only got a good start on the learning curve. A lengthy learning curve for the PVHD should be anticipated in view of the training period required for the attitude display indicator (ADI). This does seem to point out that the PVHD, in its present form, is simply not as compelling as the natural horizon. It can also be concluded that any attempt at a valid evaluation of the PVHD concept can be done only under instrument meteorological conditions (IMC) or validly simulated IMC conditions. The knee in the learning curve, however, may be reached without full IMC, although it may take much longer to reach.

Schofield, B. L.↗

The color of polarization in cuprate superconductors

A technique for the identification of individual anisotropic grains in a heterogeneous and opaque material involves the observation of grain color in reflected light through crossed polarizers (color of polarization). Such colors are generally characteristic of particular phases. When grains of many members of the class of hole carrier cuprate superconductors are so viewed, using a xenon light source (600 K color temperature), a characteristic color of polarization is observed. This color was studied in many of these cuprate superconductors and a strong correlation was found between color and the existence of superconductivity. One of the members of the electron carrier cuprate superconductors (Nd(1.85)Ce(.15)CuO(4-x) was examined and found that it possesses the same color of polarization as all the electron hole carrier cuprate superconductors so far examined. The commonality of the characteristic color in the cuprate superconductors indicated that the presence of this color is independent of the nature of charge carriers. The correlation of this color with existence of superconductivity suggests that the origin of the color relates to the origin of superconductivity in the cuprate superconductors. Photometric techniques are also discussed.

Hoff, H. A.↗

Optical Durability of Contemporary PV Encapsulants Through Artificial UV Weathering

Modern c-Si photovoltaic (PV) cells provide high performance but can be vulnerable to ultraviolet light induced degradation (UV-ID). Encapsulants, if chosen correctly, can mitigate UV-ID of the PV cell. Here, we explore performance and durability of 14 commercial encapsulant materials before, during, and after irradiation with UV-containing light. Materials include contemporary, polymer-based encapsulants with a base polymer of poly (ethylene co-vinyl acetate) (EVA), polyethylene-..alpha..-olefin (POE), or their composite (EPE). Polymers contain additives that induce UV-blocking, UV-transmitting, or UV-downshifting properties. We use test coupons to study degradation in a chamber held at 65 degrees C under a xenon light source for up to 4000 h of exposure, corresponding to a cumulative dose of 11.5 MJ/m2 at 340 nm. We examine optical properties including spectral transmittance, yellowness index and spectral fluorescence, considering changes to both the encapsulant and glass as a function of weathering time. Degradation modes identified include discoloration, changes to UV cutoff wavelength, changes to solar-weighted transmittance, and most notably a change to the UV-managing properties of some additives. We propose the use of solar-weighted transmittance in the 300- to 400-nm range to better track performance changes in the UV region associated with the UV-related additive. This is especially relevant for the emerging class of UV-downshifting additives, as metrics like UV-cutoff can understate the degree of degradation or change in these materials. While most encapsulants show very little change after weathering, some show significant changes that directly impact how much UV light would reach an underlying cell.

14 SOLAR ENERGY↗

Shock tube measurements of the optical absorption of triatomic carbon, C3

The spectral absorption of C3 has been measured in a shock tube using a test gas mixture of acetylene diluted with argon. The absorption of a pulsed xenon light source was measured by means of eight photomultiplier channels to a spectrograph and an accompanying drum camera. The postshock test gas temperature and pressure were varied over the range 3300-4300 K and 0.36 to 2.13 atmospheres, respectively. The results showed appreciable absorption from C3 for the wavelength range 300 to 540 nanometers. The computed electronic oscillator strength varied from 0.12 to 0.06 as a function of temperature.

Jones, J. J.↗

The optical absorption of triatomic carbon C3 for the wavelength range 260 to 560 nm

The spectral absorption properties of C3 have been measured in a shock tube containing a test gas mixture of acetylene diluted with argon. The absorption of a pulsed xenon light source was measured by means of eight photomultiplier channels to a spectrograph and an accompanying drum camera. The postshock test gas temperature and pressure were varied over the range 3240 to 4300 K and 37 to 229 kPa, respectively. The results showed appreciable absorption by C3 for the wavelength range 300 to 540 nm. The various reported measurements of the heat of formation of C3 which are available in the open literature were reviewed, and a value of 198 kcal/mol is recommended. This value, along with best available values for other species, was used to calculate the number density of C3 for the conditions of the present experiments in order to compute absorption cross section or electronic oscillator strength. The computed electronic oscillator strength varied from a high of 0.062 at 3300 K to a low of 0.036 at 3900 K.

Jones, J. J.↗

HydroX, a light dark matter search with hydrogen-doped liquid xenon time projection chambers

Experimental efforts searching for dark matter particles over the last few decades have ruled out many candidates led by the new generation of tonne-scale liquid xenon. For light dark matter, hydrogen could be a better target than xenon as it would offer a better kinematic match to the low mass particles. This article describes the HydroX concept, an idea to expand the dark matter sensitivity reach of large liquid xenon detectors by adding hydrogen to the liquid xenon. We discuss the nature of signal generation in liquid xenon to argue that the signal produced at the interaction site by a dark matter–hydrogen interaction could be significantly enhanced over the same interaction on xenon, increasing the sensitivity to the lightest particles. We discuss the technical implications of adding hydrogen to a xenon detector, as well as some background considerations. Finally, we make projections as to the potential sensitivity of a HydroX implementation and discuss next steps.

Experimental particle physics↗

HydroX, a light dark matter search with hydrogen-doped liquid xenon time projection chambers

Experimental efforts searching for dark matter particles over the last few decades have ruled out many candidates led by the new generation of tonne-scale liquid xenon. For light dark matter, hydrogen could be a better target than xenon as it would offer a better kinematic match to the low mass particles. This article describes the HydroX concept, an idea to expand the dark matter sensitivity reach of large liquid xenon detectors by adding hydrogen to the liquid xenon. We discuss the nature of signal generation in liquid xenon to argue that the signal produced at the interaction site by a dark matter–hydrogen interaction could be significantly enhanced over the same interaction on xenon, increasing the sensitivity to the lightest particles. We discuss the technical implications of adding hydrogen to a xenon detector, as well as some background considerations. Finally, we make projections as to the potential sensitivity of a HydroX implementation and discuss next steps.

Lippincott, W. H. [UC, Santa Barbara] (ORCID:00000↗

A study of the scintillation light induced in liquid xenon by electrons and alpha particles

The time dependence and the intensity of the primary scintillation light in liquid Xe excited by Am-241 alpha particles and Bi-207 internal-conversion electrons were measured at different electric-field strengths. High-purity liquid Xe was used to fill a parallel-plate ionization chamber equipped with a CaF2 window coupled to a UV-sensitive photomultiplier tube. The effect of the specific ionization density on the scintillation light and the time correlation between the light signal and the charge signal is reported. It is demonstrated that the fast scintillation signal produced in liquid Xe by an ionizing particle provides an ideal trigger in a detector aiming at a complete three-dimensional event reconstruction with an excellent background rejection capability.

Aprile, Elena↗

Reflectivity and PDE of VUV4 Hamamatsu SiPMs in liquid xenon

Considering reflective properties of materials and photodetection efficiency (PDE) of photodetectors is important for optimizing energy resolution and sensitivity of the next generation neutrinoless double beta decay, direct detection dark matter, and neutrino oscillation experiments that will use noble liquid gases, such as nEXO, DARWIN, DarkSide-20k, and DUNE . Little information is currently available about reflectivity and PDE in liquid noble gases, because such measurements are difficult to conduct in a cryogenic environment and at short enough wavelengths. Here we report a measurement of specular reflectivity and relative PDE of Hamamatsu VUV4 silicon photomultipliers (SiPMs) with 50 μ m micro-cells conducted with xenon scintillation light ( ~ 175 nm) in liquid xenon. The specular reflectivity at 15 o incidence of three samples of VUV4 SiPMs is found to be 30.4 ± 1.4%, 28.6 ± 1.3%, and 28.0 ± 1.3%, respectively. The PDE at normal incidence differs by ± 8% (standard deviation) among the three devices. The angular dependence of the reflectivity and PDE was further measured for one of the SiPMs. Both the reflectivity and PDE decrease as the angle of incidence increases. This is the first measurement of an angular dependence of PDE and reflectivity of a SiPM in liquid xenon.

47 OTHER INSTRUMENTATION↗

Handheld Searchlight

Streamlite Inc. reengineered the NASA searchlight for commercial use. The brightest hand-held light yet produced is result of Xenon-arc lights developed as solar simulators at Johnson Space Center. Intense battery powered searchlight is rated a million candlepower - 50 times brighter than high beam headlights of a car, and weighs only 7 pounds. Lifetime of xenon lamp is at least 200 hours at maximum intensity. Retail cost is under $400.00. Company has introduced smaller unit in shape of a flashlight, produces 20,000 candlepower and costs approximately $60.00.

Source record↗

Impact of xenon doping in the scintillation light in a large liquid-argon TPC

The use of xenon-doped liquid argon (Xe-doped LAr) is a promising alternative for large-scale liquid argon Time Projection Chambers (LAr-TPC), since it mitigates the light suppression due to impurities and it also improves the photon-detection efficiency and uniformity with the distance. This study analyses the impact of using Xe-doped LAr in ProtoDUNE Dual-Phase, a 750 ton Dual-Phase LAr-TPC placed at CERN. ProtoDUNE Dual-Phase completed a Xe-doping data-taking campaign in summer 2020 by re-filling the detector with 230 tons of Xe-doped LAr contaminated with nitrogen, and performing dedicated nitrogen injections. The effects of the presence of Xe at 5.8 ppm in the scintillation light production and propagation are analysed in this paper, showing an increase of the collected photons, but a suppression of the light signal amplitude. A 60% increase of the light attenuation length is measured. The impact on the scintillation time profile is also studied. A model to fit the time profile is proposed and the time constants of the physics processes are obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sunlight-Pumped Laser

Organic iodide gas is stimulated by portion of Sun's spectrum to emit laser light. Chopper forms pulses from beam of Xenon-Arc light. Chopper is only necessary to avoid buildup of laser-quenching species in sealed tube of present experiment. Perfluoropropyliodide lasing medium functions at temperatures of about 670 K, a fact that reduces cooling requirements in space.

Weaver, W. R. J.↗

The influence of ambient light spectrum (LED, INC, CFL, Xenon…) on the efficiency of perovskite indoor photovoltaic solar cells for Internet of Things (IoT) applications

This record provides a numerical investigation of a MAGeI₃-based perovskite solar cell with the structure FTO/TiO₂/MAGeI₃/Spiro-OMeTAD, evaluated for both outdoor and indoor light-harvesting applications using the SCAPS-1D simulator. Device performance is analyzed under AM 1.5G sunlight and several artificial light sources, including LED, incandescent, compact fluorescent lamp (CFL), flashlight, and xenon illumination. The study reports initial and optimized power conversion efficiencies and examines the influence of absorber layer thickness and bandgap on device performance under different lighting conditions. The results highlight the potential of MAGeI₃-based perovskite solar cells for indoor energy harvesting and low-power Internet of Things (IoT) applications.

14 SOLAR ENERGY↗