Search NASA⌕ Search

SEARCH · Search NASA

Results for “ZINC 82”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A=82☆

The evaluators present in this publication spectroscopic data and level schemes from radioactive decay and nuclear reactions studies for all isobars, Z=28(Ni) to Z=42(Mo), with mass number A=82. For {sup 82}Ni not much is known other than its identification. Most of the new data, i.e., after the last NDS (2003Tu03), are based on compilations included in XUNDL. Contributions of the various compilers in XUNDL are gratefully acknowledged.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Spectral and Chemical Measurement of Pollutants on Snow Near South Pole, Antarctica

Remote sensing of light-absorbing particles (LAPs), or dark colored impurities, such as black carbon (BC) and dust on snow, is a key remaining challenge in cryospheric surface characterization and application to snow, ice, and climate models. We present a quantitative data set of in situ snow reflectance, measured and modeled albedo, and BC and trace element concentrations from clean to heavily fossil fuel emission contaminated snow near South Pole, Antarctica. Over 380 snow reflectance spectra (350-2500 nm) and 28 surface snow samples were collected at seven distinct sites in the austral summer season of 2014-2015. Snow samples were analyzed for BC concentration via a single particle soot photometer and for trace element concentration via an inductively coupled plasma mass spectrometer. Snow impurity concentrations ranged from 0.14 to 7000 part per billion (ppb) BC, 9.5 to 1200 ppb sulfur, 0.19 to 660 ppb iron, 0.013 to 1.9 ppb chromium, 0.13 to 120 ppb copper, 0.63 to 6.3 ppb zinc, 0.45 to 82 parts per trillion (ppt) arsenic, 0.0028 to 6.1 ppb cadmium, 0.062 to 22 ppb barium, and 0.0044 to 6.2 ppb lead. Broadband visible to shortwave infrared albedo ranged from 0.85 in pristine snow to 0.62 in contaminated snow. LAP radiative forcing, the enhanced surface absorption due to BC and trace elements, spanned from less than 1 W m(exp. -2) for clean snow to approximately 70 W m(exp. -2) for snow with high BC and trace element content. Measured snow reflectance differed from modeled snow albedo due to specific impurity-dependent absorption features, which we recommend be further studied and improved in snow albedo models.

pollution↗

A Comparison of Groundwater Sampling Technologies, Including Passive Diffusion Sampling, for Radionuclide Contamination - 20205

Using traditional high-flow purge methods for long-term water quality monitoring of deep groundwater wells can be expensive, affect contaminant migration, and produce excessive volumes of discharge water that can be difficult to manage. The use of low-flow pumping methods and depth discrete bailers (DDBs) can reduce the cost of sampling deep groundwater wells. In general, using different pumping methods to obtain reproducible and representative groundwater can be challenging. Passive diffusion samplers (PDSs) have successfully been used in long-term monitoring for volatile organic compounds, major ions, and trace-elements, but application has been limited for stable and radioactive isotopes. Beginning in 2018, the United States Geological Survey (USGS) conducted three sampling events to test the ability of PDSs and DDBs to obtain reproducible and representative groundwater samples. The sampled well is completed in a regional, permeable carbonate aquifer and is one in a set of wells that have historically been used for tritium tracer testing. All samples were obtained at 180 m (590 ft) below land surface (bls) in a 13.97 cm (5.5 inch) uncased well that has a total depth of 202 m (662 ft) bls. The first sampling event deployed a regenerated cellulose dialysis membrane (RCDM) PDS for 14 days with deionized water as the blank. The second sampling event deployed a RCDM for 27 days also with deionized water as the blank. The third sampling event deployed a Dual Membrane (DM) PDS for 65 days using a blank of tritium-dead carbonate water. The DM PDS was used to assess the effect of longer term deployment on tritium concentrations and address whether or not the PDSs reached equilibrium with ambient groundwater. The day after each of the three passive samplers were retrieved a DDB was used to obtain discrete non-integrated groundwater samples. For each DDB sampling day, the bailer was lowered into the well 10 consecutive times to determine if the water chemistry changed from the first to the last bailed sample. Quality assurance samples including blanks and duplicates were obtained during all three sampling events. All blank waters had tritium concentrations less than 21±33 pCi/L. Major ion (e.g. calcium, chloride, sodium, and sulfate) results were compared between all samples obtained with RCDM and DDB. Major ion concentrations showed a coefficient of variation of less than 6% between all RCDM and DDB samples; however, the coefficient of variation between the different deployment times and the two different methods for trace-element concentrations was much larger, particularly for manganese (82%), lead (41%), and zinc (33%). Stable isotope values were compared between the RCDM and DDB samples. The DDB sample results all fell within analytical uncertainty and were considered representative of the formation groundwater. The stable isotope values from the RCDM samples indicated that a longer deployment time was necessary to gain equilibrium and to obtain representative groundwater samples. Tritium results from groundwater samples obtained from the RCDM, DM, and DDB indicate that groundwaters obtained with PDSs produced tritium concentrations 2 to 3 times higher (between 1,426 and 3,060±87 pCi/L) than groundwaters obtained with a DDB (479 to 1,219±51 pCi/L). The longer the passive diffusion samplers were deployed, the higher the tritium concentration, suggesting that equilibrium with tritium was not reached within a 27-day deployment. DDB samples showed tritium results declining from the first to the last bailed sample for all three sampling events. This research suggests that tritium results from groundwater samples obtained from PDSs are more reproducible than samples obtained from DDBs. Also, PDSs likely do not accumulate isotopes of water but rather equilibrate with the ambient groundwater. On the other hand, both PDSs and DDBs were able to provide representative groundwater samples for major ions and have the potential to produce representative groundwater samples for stable isotopes of water (δD and δ{sup 18}O). Utilizing the most effective method for sampling groundwater is important for long-term groundwater monitoring. Quantifying the ability of passive diffusion groundwater samplers to obtain representative radioactive chemistry samples will help determine if these methods can be a useful alternative to pumping and purging wells for long-term monitoring. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of baseline tests of the EVA Metro sedan, Citi-car, Jet Industries Electra-van, CDA town car, and Otis P-500 van

Five electric vehicles were tested at vehicle test tracks using the SAE. The tests provide range data at steady speeds and for several driving cycles. Most tests were conducted with lead-acid traction batteries. The Otis Van and the Copper Electric Town Car were also tested with lead-acid and nickel-zinc batteries. The tests showed a range increase of from 82 to 101 percent depending on vehicle, speed, and test cycle.

Stenger, F. J.↗

The computer simulation of automobile use patterns for defining battery requirements for electric cars

The modeling process of a complex system, based on the calculation and optimization of the system parameters, is complicated in that some parameters can be expressed only as probability distributions. In the present paper, a Monte Carlo technique was used to determine the daily range requirements of an electric road vehicle in the United States from probability distributions of trip lengths, frequencies, and average annual mileage data. The analysis shows that a daily range of 82 miles meets to 95% of the car-owner requirements at all times with the exception of long vacation trips. Further, it is shown that the requirement of a daily range of 82 miles can be met by a (intermediate-level) battery technology characterized by an energy density of 30 to 50 Watt-hours per pound. Candidate batteries in this class are nickel-zinc, nickel-iron, and iron-air. These results imply that long-term research goals for battery systems should be focused on lower cost and longer service life, rather than on higher energy densities

Schwartz, H.-J.↗

The computer simulation of automobile use patterns for defining battery requirements for electric cars

A Monte Carlo simulation process was used to develop the U.S. daily range requirements for an electric vehicle from probability distributions of trip lengths and frequencies and average annual mileage data. The analysis shows that a car in the U.S. with a practical daily range of 82 miles (132 km) can meet the needs of the owner on 95% of the days of the year, or at all times other than his long vacation trips. Increasing the range of the vehicle beyond this point will not make it more useful to the owner because it will still not provide intercity transportation. A daily range of 82 miles can be provided by an intermediate battery technology level characterized by an energy density of 30 to 50 watt-hours per pound (66 to 110 W-hr/kg). Candidate batteries in this class are nickel-zinc, nickel-iron, and iron-air. The implication of these results for the research goals of far-term battery systems suggests a shift in emphasis toward lower cost and greater life and away from high energy density.

Schwartz, H. J.↗

A Long Cycle Life, Self-Healing Zinc-Iodine Flow Battery with High Power Density

A Zinc-iodine flow battery (ZIFB) with super long cycle life, high energy, power density and self-healing behavior was presented. The long cycle life was achieved by employing a low-cost porous polyolefin membrane with optimized pore structure and stable electrolytes. The pores in the polyolefin membrane can be filled with a solution containing oxidized I 3 - that can react with zinc dendrite. Therefore, by consuming zinc dendrite, the battery can self-recover from micro-short circuiting resulting from overcharging the battery. By using KI and ZnBr 2 as electrolytes and a high ion conductivity porous membrane, a very high power density can be achieved. As a result, the ZIFB exhibits an energy efficiency (EE) of 82% at 80 mA/cm 2 and 71% at 140 mA/cm 2 , which is 8 times higher than the currently reported for ZIFBs. In addition, a long cycling life of more than 1000 cycles over 3 months with an energy density of more than 80 Wh/L was obtained at 80 mA/cm 2 . Furthermore, a kW-class cell stack with an output of 700 W was assembled and continuously run for more than 300 cycles. We believe this ZIFB with its high power density, long cycle life, and high reliability can lead the way to development of new-generation, high-performance flow batteries.

Xie, Congxin↗

Preparation and Characterization of Sol–Gel Dip Coated Al: ZnO (AZO) Thin Film for Opto-Electronic Application

Aluminum doped zinc oxide (AZO) thin film was prepared by sol–gel dip coating method from methanol and monoethanolamine respectively, used as solvent and stabilizer agent. From the XRD study, it was confirmed that the aluminum was incorporated into the ZnO lattice. The prepared film have polycrystalline in nature and the film exhibit hexagonal wurtzite structure with (002) direction. SEM and AFM studies showed well defined smooth and uniformed wrinkle shaped grains distributed regularly on to the entire glass substrate without any pinholes and cracks. From the optical study, the observed highest transmittance was about 82% in the visible range and the band gap is 3.15 eV. Room temperature PL spectra exhibited a strong UV emission peak located at 390 nm for the deposited film. The electrical properties of the AZO thin film was studied by Hall-Effect measurement and found that it has n-type conductivity with low resistivity (ρ) of about 9.06 × 10{sup –3} Ω cm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-Capacity Aqueous Storage in Vanadate Cathodes Promoted by the Zn-Ion and Proton Intercalation and Conversion–Intercalation of Vanadyl Ions

Aqueous Zn-ion batteries (AZIBs) are promising alternatives to lithium-ion batteries in stationary storage. However, limited storage capacity and cyclic life impede their large-scale implementation. In this study, we report reversible electrochemical insertion of multi-ions into sodium vanadate (NaV 3 O 8 ) cathode materials for AZIBs, achieving a maximum storage capacity of 450 mAh g –1 at 0.05 A g –1 and a capacity retention of 82% after 500 cycles at 0.4 A g –1 . In addition to Zn 2+ and H + insertion, in situ X-ray diffraction (XRD) and X-ray absorption spectroscopy (XAS) collectively provide explicit evidence on vanadyl ions (VO 2+ ) conversion–intercalation at the NaV 3 O 8 cathode, showing the deintercalation of VO 2+ from NaV 3 O 8 and the consequent conversion of VO 2+ into V 2 O 5 on charging, and vice versa on discharging. Our study is the first to report on the cation conversion–intercalation mechanism in AZIBs. This reversible multi-ion storage mechanism provides a design principle for developing high-capacity aqueous electrode materials by engaging both the intercalation and conversion of charge carriers.

25 ENERGY STORAGE↗