Search NASA⌕ Search

SEARCH · Search NASA

Results for “ZINO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

The spin polarized linear response from density functional theory: Theory and application to atoms

Within the context of spin polarized conceptual density functional theory, the spin polarized linear response functions are introduced both in the [N, N{sub s}] and [N{sub α}, N{sub β}] representations. The mathematical relations between the spin polarized linear response functions in both representations are examined and an analytical expression for the spin polarized linear response functions in the [N{sub α}, N{sub β}] representation is derived. The spin polarized linear response functions were calculated for all atoms up to and including argon. To simplify the plotting of our results, we integrated χ(r, r′) to a quantity χ(r, r{sup ′}), circumventing the θ and ϕ dependence. This allows us to plot and to investigate the periodicity throughout the first three rows in the periodic table within the two different representations. For the first time, χ{sub αβ}(r, r{sup ′}), χ{sub βα}(r, r{sup ′}), and χ{sub SS}(r, r{sup ′}) plots have been calculated and discussed. By integration of the spin polarized linear response functions, different components to the polarisability, α{sub αα}, α{sub αβ}, α{sub βα}, and α{sub ββ} have been calculated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multiwavelength monolithic integrated fiber-optic terminal

The paper presents the Multiwavelength Monolithic Integrated Fiber Optic Terminal (MMIFOT) developed under NASA sponsorship. The program aims to utilize the advantage of optical fiber and integrated optical device technology to achieve parallel transmission of many data channels over the same optical fiber link, and to develop an eight channel wavelength multiplexed fiber optic link that transmits eight bit words in a parallel format at a nominal rate of 20 Mw/s; in the second phase of the program a transmitter/multiplexer chip will be developed. The MMIFOT configuration, the receiver/demultiplexer development, and the waveguide detector development are discussed, concluding that the first phase of the MMIFOT program will culminate in the demonstration of an eight channel receiver/demultiplexer chip with a four channel breadboard multiplexer with the data rate of 20 Mbps per channel with a dynamic range of minimum 20 dB.

Rice, R. R.↗

Multiwavelength monolithic integrated fiber optics terminal - An update

This paper serves as an update for the Multiwavelength Monolithic Integrated Fiber Optic Terminal (MMIFOT) being developed by MDAC-St. Louis for NASA's Johnson Space Center. The program objective is to utilize guided wave optical technology to develop a passive optical wavelength multiplexing subsystem with a single mode optical fiber serving as the transmission medium.

Spear-Zino, J. D.↗

Where do particle names come from?

One of the most difficult things in learning particle physics for the first time is to understand all of the various names. There are dozens and dozens and sometimes many names can apply to one particle or a single name can apply to many particles. It’s all very confusing. Luckily, Fermilab’s Dr. Don Lincoln made this video to help you sort it all out.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Best-estimate plus uncertainty thermal-hydraulic stability analysis of BWRs using TRACG code

Over the last decade, Boiling Water Reactor (BWR) power up-rates have increased plant rated power output significantly. Subsequent projects have expanded flow domains (e.g. MELLLA+) for operation at these higher power levels. This has resulted in an increase in the power to flow ratio in regions susceptible to reactor thermal-hydraulic instabilities. Since BWRs are susceptible to coupled thermal-hydraulic/nuclear oscillations when operating at these conditions, such oscillations must be prevented or reliably detected and suppressed. The Detect and Suppress Solution - Confirmation Density (DSS-CD) is the most sophisticated GEH BWR instability protection system ever employed. DSS-CD implements algorithms that monitor closely-spaced groups of Local Power Range Monitor (LPRM) detectors to detect periodic behavior typical of reactor instability events. This system is able to detect small, localized power variations in the core, distinguish between true instabilities and plant noise, and trip/scram the reactor while maintaining adequate safety margins. The combination of hardware, software, and system setpoints provides protection against violation of the Safety Limit Minimum Critical Power Ratio (SLMCPR) for anticipated oscillations. To support DSS-CD implementation, the TRACG system code is used to simulate events to confirm the capability of the DSS-CD solution for early oscillation detection and suppression. TRACG is a GEH proprietary version of the Transient Reactor Analysis Code (TRAC). TRACG includes a multi-dimensional, two-fluid model for the reactor thermal-hydraulics and a three-dimensional reactor kinetics model. The models are qualified to simulate a large variety of tests and reactor configurations, including thermal-hydraulic stability events. These features allow for detailed, best-estimate simulation of a wide range of BWR phenomena. A set of integrated TRACG event simulations for reasonably limiting anticipated events can be used to calculate the effect on the Minimum Critical Power Ratio (MCPR) performance. The purpose of the DSS-CD TRACG analysis is to confirm the inherent MCPR margin afforded by the solution design. This paper presents the Best Estimate Plus Uncertainty (BEPU) DSS-CD TRACG methodology and its application to BWR Thermal-Hydraulic (T-H) stability analyses. The statistical Code Scaling, Applicability and Uncertainty (CSAU) methodology (defined in NUREG/CR-5249) is used to calculate the MCPR uncertainty. The TRACG simulation includes a full core individual bundle model in which each fuel bundle is modeled as an individual T-H channel. The complete CSAU analysis of full core individual bundle model is an innovative solution represents the state-of-the-art stability analysis of BWRs and is the first ever full statistical analysis for stability safety analyses. The adoption of BEPU methodologies for stability analyses advances the understanding of the associated physical phenomena and maintains the safety of reactor plant operation in expanded operation domain with up-rated power. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Analysis of BWR OPRM plant data and detection algorithms with DSSPP

All U.S. BWRs are required to have licensed stability solutions that satisfy General Design Criteria (GDC) 10 and 12 of 10 CFR 50 Appendix A. Implemented solutions are either detect and suppress or preventive in nature. Detection and suppression of power oscillations is accomplished by specialized hardware and software such as the Oscillation Power Range Monitor (OPRM) utilized in Option III and Detect and Suppress Solution - Confirmation Density (DSS-CD) stability Long-Term Solutions (LTSs). The detection algorithms are designed to recognize a Thermal-Hydraulic Instability (THI) event and initiate control rod insertion before the power oscillations increase much higher above the noise level that may threaten the fuel integrity. Option III is the most widely used long-term stability solution in the US and has more than 200 reactor years of operational history. DSS-CD represents an evolutionary step from the stability LTS Option III and its licensed domain envelopes the Maximum Extended Load Line Limit Analysis Plus (MELLLA +) domain. In order to enhance the capability to investigate the sensitivity of key parameters of stability detection algorithms, GEH has developed a new engineering analysis code, namely DSSPP (Detect and Suppress Solution Post Processor), which is introduced in this paper. The DSSPP analysis tool represents a major advancement in the method for diagnosing the design of stability detection algorithms that enables designers to perform parametric studies of the key parameters relevant for THI events and to fine tune these system parameters such that a potential spurious scram might be avoided. Demonstrations of DSSPPs application are also presented in this paper utilizing actual plant THI data. A BWR/6 plant had a plant transient that included unplanned recirculation pump transfer from fast to slow speed resulting in about 100% to {approx}40% rated power decrease and about 99% to {approx}30% rated core flow decrease. As the feedwater temperature is reduced to equilibrium conditions, the power increased from about {approx}40% to about {approx}60% with little change inflow. A THI event developed and subsequently, an OPRM initiated scram occurred with Option III. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗